• 제목/요약/키워드: Dental core

검색결과 263건 처리시간 0.032초

전부도재수복물을 위한 수종의 코어 세라믹의 반투명도 및 색 안정성 (Translucency and Color Stability of Various Core Ceramics for All-Ceramic Restoration)

  • 오상천;이해형;신미란;박광수
    • 구강회복응용과학지
    • /
    • 제23권2호
    • /
    • pp.157-170
    • /
    • 2007
  • Purpose: This investigation was designed to determine the translucency and color stability of various core ceramics for all-ceramic restoration using the CIE $L^*a^*b^*$ system. Material and Methods: IPS e.max Press ceramic(Ivoclar-Vivadent, Liechtenstein), $LAVA^{TM}$ All Ceramic(3M-Espe, Germany), Cercon Smart Ceramic(Dentsply, Germany), and Z-match Ceramic(DentAim, Korea) were used for this study. For the specimens of zirconia oxide ceramics, the as-sintered cylindrical blanks($11.0{\times}25.0mm$) were machined into the shape of a disk(0.4, 0.8, 1.5 mm in thickness, 10 mm in diameters) with a diamond grind machine. The IPS e.max Press specimens ($0.8{\times}10mm$) were fabricated using the "lost wax" technique. CIE $L^*a^*b^*$ coordinates and light transmission were recorded for each specimen with a spectrophotometer(CM-2600d, Minolta, Japan). Color differences were calculated using the equation, ${\Delta}E^*ab=[({\Delta}L^*)2+({\Delta}a^*)2+({\Delta}b^*)2]1/2$. Results: The results were obtained as follows: 1. The most translucent group was IPS e.max Press ceramic that is a glass-ceramic, and $Lava^{TM}$ and Z-match ceramic were more translucent than Cercon Smart ceramic in zirconia ceramic group. 2. In the all groups, there was no significant translucent change after 6 times heat-treatments required to make a final restoration. 3. Colored zirconia was showed more yellowish and dark than uncolored zirconia. 4. After heat-pressing, IPS e.max Press ceramic was showed high ${\Delta}E^*ab$ value(4.1 of eM1, 6.8 of eM2) that means to be more whiter than before heat-pressing. However, there was no color change after additive heat treatments for final restoration. 5. In the colored zirconia groups, there was no significant color change after some heat-treatments required to make a final restoration.

악하선 내 타석의 미세형상 및 화학적 조성 (Micromorphology and Chemical Composition of a Sialolith in the Submandibular Gland Duct)

  • 임영관;송호준;김병국
    • Journal of Oral Medicine and Pain
    • /
    • 제36권3호
    • /
    • pp.161-167
    • /
    • 2011
  • 타석은 타액선에 발견되는 흔한 병리 상태 중 하나이다. 타석의 형성과 관련된 기전은 아직까지 명확하게 밝혀지지 않았다. 본 연구에서는 악하선의 만성타액선염을 앓고 있는 58세 여성 환자로부터 얻은 타석을 전자현미경 및 에너지분산 X선 분광법을 통해 화학적인 조성과 미세형상을 분석하였다. 전자현미경 평가에서 고도로 광화된 무정형 핵이 층판의 동심원상 구조로 둘러싸인 형태가 관찰되었으나, 이물질, 유기물질 또는 미생물의 소견은 확인되지 않았다. 에너지분산 X선 분광 분석에서 중심부 핵은 Ca, O 및 P로만 구성되어 있었고, C도 중심부 근처에서 높은 함량으로 검출되었다. 이러한 결과는 타석의 무기물 조성은 주로 수산화인회석 결정으로 되어 있고 중심핵 주변으로 무기-유기 구조가 형성되어 있어, 악하선관 내 타석의 핵이 무기결정핵의 성장을 촉진하는 타액선염에 의해 이차적으로 형성되었을 가능성을 제시한다.

The effect of ceramic thickness and number of firings on the color of a zirconium oxide based all ceramic system fabricated using CAD/CAM technology

  • Bachhav, Vinay Chila;Aras, Meena Ajay
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권2호
    • /
    • pp.57-62
    • /
    • 2011
  • MATERIALS AND METHODS. Ceramics have a long history in fixed prosthodontics for achieving optimal esthetics and various materials have been used to improve ceramic core strength. However, there is a lack of information on how color is affected by fabrication procedure. The purpose of this study was to evaluate the effects of various dentin ceramic thicknesses and repeated firings on the color of zirconium oxide all-ceramic system (LavaTM) fabricated using CAD/CAM technology. MATERIALS AND METHODS. Thirty disc-shaped cores, 12 mm in diameter with a 1 mm thickness were fabricated from zirconium oxide based all ceramic systems ($Lava^{TM}$, 3M ESPE, St Paul, MN, USA) and divided into three groups (n = 10) according to veneering with dentin ceramic thicknesses: as 0.5, 1, or 1.5 mm. Repeated firings (3, 5, 7, or 9) were performed, and the color of the specimens was compared with the color after the initial firing. Color differences among ceramic specimens were measured using a spectrophotometer (VITA Easyshade, VITA Zahnfabrik, Bad $S{\ddot{a}}ckingen$, Germany) and data were expressed in CIELAB system coordinates. A repeated measures ANOVA and Bonferroni post hoc test were used to analyze the data (n = 10, ${\alpha}=.05$). RESULTS. $L^{\ast}a^{\ast}b^{\ast}$ values of the ceramic systems were affected by the number of firings (3, 5, 7, or 9 firings) (P<.001) and ceramic thickness (0.5, 1, or 1.5 mm) (P<.001). Significant interactions were present in $L^{\ast}a^{\ast}b^{\ast}$ values between the number of firings and ceramic thickness (P<.001). An increase in number of firings resulted in significant increase in $L^{\ast}$ values for both 0.5 mm and 1.5 mm thicknesses (P<.01, P=.013); however it decreased for 1 mm thickness (P<.01). The $a^{\ast}$ values increased for 1 mm and 1.5 mm thicknesses (P<.01), while it decreased for 0.5 mm specimens. The $b^{\ast}$ values increased significantly for all thicknesses (P<.01, P=.022). As the dentin ceramic thickness increased, significant reductions in $L^{\ast}$ values (P<.01) were recorded. There were significant increases in both $a^{\ast}$ and $b^{\ast}$ values (P<.01) as the dentin ceramic thickness increased. CONCLUSION. The number of firings and dentin ceramic thickness have a definite effect on the final color of all ceramic system tested. The mean ${\Delta}E$ value increased as the dentin ceramic thicknesses increased for zirconium-oxide based all ceramic specimens tested. However, the mean ${\Delta}E$ values were less than 3.7${\Delta}E$ units which is rated as a match in the oral environment.

Oral tissue response to soft tissue expanders prior to bone augmentation: in vitro analysis and histological study in dogs

  • Yoo, Jung Min;Amara, Heithem Ben;Kim, Min Kyoung;Song, Ju Dong;Koo, Ki-Tae
    • Journal of Periodontal and Implant Science
    • /
    • 제48권3호
    • /
    • pp.152-163
    • /
    • 2018
  • Purpose: To determine whether the swelling and mechanical properties of osmotic self-inflating expanders allow or not the induction of intraoral soft tissue expansion in dogs. Methods: Three different volumes (0.15, 0.25, and 0.42 mL; referred to respectively as the S, M, and L groups) of soft tissue expanders (STEs) consisting of a hydrogel core coated with a silicone-perforated membrane were investigated in vitro to assess their swelling behavior (volume swelling ratio) and mechanical properties (tensile strength, tensile strain). For in vivo investigations, the STEs were subperiosteally inserted for 4 weeks in dogs (n=5). Soft tissue expansion was clinically monitored. Histological analyses included the examination of alveolar bone underneath the expanders and thickness measurements of the surrounding fibrous capsule. Results: The volume swelling ratio of all STEs did not exceed 5.2. In tensile mode, the highest mean strain was registered for the L group ($98.03{\pm}0.3g/cm$), whereas the lowest mean value was obtained in the S group ($81.3{\pm}0.1g/cm$), which was a statistically significant difference (P<0.05). In addition, the S and L groups were significantly different in terms of tensile strength ($1.5{\pm}0.1g/cm$ for the S group and $2.2{\pm}0.1g/cm$ for the L group, P<0.05). Clinical monitoring showed successful dilatation of the soft tissues without signs of inflammation up to 28 days. The STEs remained volumetrically stable, with a mean diameter in vivo of 6.98 mm, close to the in vitro post-expansion findings (6.69 mm). Significant histological effects included highly vascularized collagen-rich fibrous encapsulation of the STEs, with a mean thickness of $0.67{\pm}0.12mm$. The bone reaction consisted of resorption underneath the STEs, while apposition was observed at their edges. Conclusions: The swelling and mechanical properties of the STEs enabled clinically successful soft tissue expansion. A tissue reaction consisting of fibrous capsule formation and bone loss were the main histological events.

디지털 이미지 상관법을 이용한 Methacrylate기질과 Silorane기질 복합레진의 치아 수복 시 중합수축거동 (Polymerization Shrinkage Behavior Measured by Digital Image Correlation for Methacrylate-based and Silorane-based Composites During Dental Restoration)

  • 박정훈;최낙삼
    • Composites Research
    • /
    • 제33권3호
    • /
    • pp.125-132
    • /
    • 2020
  • 치과용 복합레진 Filtek P90 (3M ESPE, USA)과 Clearfil AP-X (Kuraray, Japan)를 대상으로 디지털 이미지 상관법을 이용하여 광중합 시 발생하는 수축거동을 관찰하고 등가탄성계수를 적용한 유한요소해석을 통해 시편표면의 응력분포를 산출하여 수축률분포와 비교하였다. 광조사 중과 광조사 후의 촬영 조건을 달리하여 CCD 카메라를 이용한 시편의 변형사진을 획득하고 디지털 이미지 상관분석을 하였다. DIC 분석 결과 상기의 복합레진 모두에서, 비균일한 수축변형률 분포가 관찰되었으며 링시편 내부의 레진 중심부가 자유로운 유동성으로 레진/링의 계면부보다 큰 수축 변형률이 발생하였다. 레진의 중심으로부터 거리가 멀어질수록 반경방향 평균수축률은 감소하였으며, 광조사동안에 발생한 반경방향 평균수축률은 경화시험종료(10 min) 후 발생한 반경방향 평균수축률 값을 기준으로 P90은 33%, AP-X는 57% 수준이었다. P90과 AP-X가 광조사 중의 수축거동이 크게 달랐음을 확인하였다. 레진/링의 계면부에 가까운 레진에서는 광조사 후에 인장변형률이 급격히 커져서 계면부가 인장응력을 받아 취약하게 됨을 확인하였다.

구강스캐너 5종의 협측 악간관계 스캔 정확성 비교 연구 (Accuracy comparison of buccal bite scans by five intra-oral scanners)

  • 박지만;전진;허성주
    • 구강회복응용과학지
    • /
    • 제34권1호
    • /
    • pp.17-31
    • /
    • 2018
  • 목적: 이 연구의 목적은 다양한 구강 스캐너를 사용하여 협측 악간관계 스캔에 따른 상하악 악궁 관계의 정확성을 비교 평가하는 것이다. 연구 재료 및 방법: 정상 교합을 보이는 상하악 전악 모델을 5종(Cerec Omnicam, CS3500, iTero, Trios, TruDef)의 구강 스캐너로 제조사의 지시대로 스캔하였다. 폴리비닐실록산 교합 재료로 고정시킨 금속 지그를 이용하여 우측 구치부를 1, 2, 3, 4 mm 단계적으로 올린 후 좌측 협측 악간관계 스캔을 채득하였다. 두 데이터를 중첩하여 전체적인 삼차원 변이를 평가하였고, 교합 평면에 수직인 단면을 분석하여 교두간 거리의 양과 방향을 평가하였다. 결과: 중첩연구에서 Cerec Omnicam ($165.5{\mu}m$)이 가장 적은 변이를 보였고, CS3500 ($369.0{\mu}m$)이 가장 큰 변이를 보였으며(P < 0.01), 1 mm 보다 3, 4, 2 mm 이개 그룹에서 변이가 유의미하게 컸다(P < 0.01). 단면 연구에서는 Cerec Omnicam이 교두끼리의 거리가 가장 먼 변이를 보였고($-242.8{\mu}m$), CS3500이 가장 가까워지는 변이를 보였으며($312.5{\mu}m$), 다른 거상 높이 보다 3 mm 이개 그룹에서 유의하게 변이가 컸다(P < 0.01). 결론: 구강 스캐너 마다 협측 악간관계 스캔을 이용해 상하악 교합 관계를 재현하는 정확성이 달랐다.

불교식 명상을 통한 질병 회복 경험 (The Experiences of Recovery from Disease in Patients doing Meditation)

  • 손행미;김주현;김종훈
    • 대한간호학회지
    • /
    • 제35권6호
    • /
    • pp.1025-1035
    • /
    • 2005
  • Purpose: The purpose of this study was to explore the experiences of recovery from disease in the patients doing a kind of Buddhist meditation, and to develop a grounded theory about meditation. Method: Data was collected by an in-depth interview using tape-recordings from sixteen participants doing meditation. The data was analyzed using the grounded theory method proposed by Strauss and Corbin(1998). Result: The core category was discovering the true self. The participants began to do meditation because of their disease. They experienced obstacles due to incomplete religious acceptance. However, their faith grew gradually based on religious experiences that were indescribable. Finally, they entirely trusted the inner healer, which is emphasized in meditation. The strategies that they used were self reflection and seeking help for accepting deep meditation. They were stabilized in physical, psychological and social daily living. The processes of discovering the true self were identified as entering religious discipline, embodying religious discipline, self-accomplishing religious faith, and recovering mind-body health. Conclusion: This study provided the understanding of mind-body integration. Empirical research may be needed to prove scientifically the effects of meditation.

고정성 임플란트 보철물을 이용한 완전구강회복 증례 (Functional and esthetical full mouth rehabilitation with implant supported prostheses: A case report)

  • 연제웅;임영준;권호범;김명주
    • 대한치과보철학회지
    • /
    • 제53권1호
    • /
    • pp.81-85
    • /
    • 2015
  • 본 증례의 환자는 상악 전치부 보철물의 파절 및 기존에 사용하던 하악 의치의 불편감 때문에 임플란트를 이용한 고정성 보철을 원한다는 주소로 내원하였다. 상악동 거상술, 하악지 골이식과 함께 상악에 5개, 하악에 6개의 임플란트를 식립하였다. 전치부와 양쪽 구치부의 세 부분으로 나누어 임플란트 지지형 고정성 보철물을 장착하였다. 이상과 같은 과정을 통해 적절한 심미적, 기능적 결과를 얻었기에 이를 보고하고자 한다.

금속 유지장치의 오염이 레진 접착 결합력에 미치는 영향 (The effect of contamination of the etched matal retainer on resin bonding strength)

  • 박하옥;방몽숙
    • 구강회복응용과학지
    • /
    • 제18권3호
    • /
    • pp.217-224
    • /
    • 2002
  • The purpose of this study was to evaluate the influence of saliva contamination on the resin bonding of the etched metal retainers. The test samples were made of Verabond, and divided into 3 groups. Retainers in group1 had normally etched metal surfaces. Retainers in group2 had normally etched metal surfaces which were saliva-contaminated for 30 seconds and cleaned with streaming, luke-warm for 1 minute and dried thoroughly. Retainers in group3 had normally etched metal surfaces which were saliva- contaminated for 30 seconds and dried thoroughly without water-cleansing. Each 3 group specimen was watched on SEM. A resin core, 5mm in diameter and 6mm in length, was made of Panavia using Teflon mold on the each specimen. These 3 groups were tested to evaluate shear bond strength, using universal testing machine. The results were as follows : 1. The shear bond strength showed no significant difference between group1 and group2. 2. The shear bond strength showed significant difference between group1 and group3. 3. The shear bond strength significant difference between group2 and group3. 4. Scanning electron microscope photographs of group1 and group2 showed no signs of contamination but of group3 showed somewhat contaminated.

치근단절제술을 이용한 치근단 병소의 치료에 대한 증례보고 (CASE REPORT FOR TREATMENT OF PERIAPICAL LESION BY USING APICOECTOMY)

  • 이성준;손흥규;김성오;최형준
    • 대한소아치과학회지
    • /
    • 제24권3호
    • /
    • pp.575-580
    • /
    • 1997
  • It has been reported that the operative treatment for the preservation of tooth having periapical lesion has shown over ninety percent of success whereas in the case where calcified canal is severe, canal is perforated, ledge is formed, tooth restored by post and core and cases where symptoms still exist after treatment, endodontic treatment may not all be the solution in attaining a successful treatment. Thus Apicoectomy would generally be used to prevent the loss of tooth having periapical lesion where treatment prognosis is poorly evaluated by endodontic treatment. In case 1 and 2, endodontic treatment was applied due to unilocular radiolucent lesion in periapical area but the symptoms somehow did not show improvement and therefore operated apicoectomy, and as in case 1, favorable results were attained but as in case 2, yet more observation has to be done. The followings are the results we have concluded : 1. In the process of endodontic treatment, absolute canal obturation has great effect on attaining successful treatment. 2. In cases where endodontic treatment is not highly recommended, for example, tooth having dental pulp and periapical lesion, favorable results can be attained by applying apicoectomy.

  • PDF