• Title/Summary/Keyword: Dental chair

Search Result 94, Processing Time 0.029 seconds

A COMPARISON STUDY ON DENTAL TREATMENT TIME OF PATIENTS WITH DIFFERENT TYPES OF DISABILITIES (장애유형별 치과진료시 소요시간에 관한 비교연구)

  • Lee, Wooram;Kim, Young-Jae
    • The Journal of Korea Assosiation for Disability and Oral Health
    • /
    • v.10 no.2
    • /
    • pp.78-83
    • /
    • 2014
  • The objective of this study was to confirm the validity of classification of dental disability by measuring the dental treatment time required for disabled patients and identify the disability type that requires more of chair time. As a result of measuring a total of 123 patients who were admitted to the Seoul dental hospital for the disabled on Oct. 2014, I was able to make the following conclusions: 1. For dental counseling and check-up, the chair time did not show significant differences between the different types of disability. 2. For periodontal treatment, restorative treatment, root canal treatment, and surgical treatment, the difference of the chair time for dentally disabled patients was significantly longer than that of non-dentally disabled patients. 3. The difference in the total chair time for prosthetic treatment was statistically insignificant. However, each of the prosthetic treatment steps did show statistically significant differences.

Case of Improving Design by Using Analysis Model of Hydraulic System for Dental Chair (치과용 유니트체어 유압구동 시스템 해석모델을 활용한 개선설계 사례)

  • Dae Kyung Noh;Dong Won Lee;Taek June Kim;Joo Sup Jang
    • Journal of Drive and Control
    • /
    • v.20 no.2
    • /
    • pp.1-6
    • /
    • 2023
  • This study aims to develop a Korean dental chair hydraulic circuit by improving the existing equipment in order to localize foreign leading companies' products. The suggested Hydraulic circuit can be applicable to varied sectors where height and backrest angle control of chair-type equipment are required. The study followed the steps below. First, three kinds of foreign hydraulic circuits were analyzed and three kinds of Korean dental chair hydraulic circuits were suggested. Second, it was determined whether the three kinds of Korean hydraulic circuits operate normally through SimulationX, a software specialized in multi domain analysis, and the effectiveness of each circuit was examined.

Chair-side surface treatment method for inducing hydrophilicity in titanium dental implant (치과용 티타늄 임플란트의 골융합 증진을 위한 체어사이드 친수성 표면처리방법)

  • Lee, Jung-Hwan;Jun, Soo-Kyung;Lee, Hae-Hyoung
    • The Journal of the Korean dental association
    • /
    • v.54 no.12
    • /
    • pp.985-995
    • /
    • 2016
  • Titanium (Ti) has been widely used for dental implant due to great biocompatibility and bonding ability against natural alveolar bone. A lot of titanium surface modification has been introduced in dentistry and, among them, methods to introduce micro/nano-roughened surface were considered as clinically approved strategy for accelerating osseointegration of Ti dental implant. To have synergetic effect with topography oriented favors in cell attachment, chair-side surface treatment with reproducibility of micro/nano-topography is introduced as next strategy to further enhance cellular functionalities. Extensive research has been investigated to study the potential of micro/nano-topography preserved chair-side surface treatment for Ti dental implant. This review will discuss ultraviolet, low level of laser therapy and non-thermal atmospheric pressure plasma on Ti dental implant with micro/nano-topography as next generation of surface treatment due to its abilities to induce super-hydrophilicity or biofunctionality without change of topographical cues.

  • PDF

Outcome of Palliative and Radical Radiotherapy in Patients with Oral Squamous Cell Carcinoma - a Retrospective Study

  • Rai, Narendra Prakash;Divakar, Darshan Devang;Al Kheraif, Abdulaziz Abdullah;Ramakrishnaiah, Ravikumar;Mustafa, Shabil Mohamed;Durgesh, BH;Basavarajappa, Santhosh;Khan, Aftab Ahmed
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.16
    • /
    • pp.6919-6922
    • /
    • 2015
  • Background: The treatment selection for the oral squamous cell carcinoma remains controversial. Radiation therapy or surgical excision of the lesion can be applied as the sole treatment or it can be used in combination with other treatment modalities. Radiotherapy is considered to be the safest of all the treatment modalities and can be used in several situations for oral and oropharyngeal cancers. The aim of this study was to evaluate the survival outcome differences in patients treated with radical and palliative radiotherapy as the primary treatment modality. Materials and Methods: The study included a total of 47 patients with oral cancer reporting to our hospital between years 2009 to 2010. The age group for the selected patients was more than 65 years, treated with radical and palliative radiotherapy with no prior surgical interventions. Patients were evaluated till Dec 2013 for overall survival time. Results: Twenty nine patients were treated with radical radiotherapy as main stay of treatment, out of which 21 died during the follow up time with median survival of $352{\pm}281.7$ days with 8 patients alive. All the 16 patients were dead who received palliative radiotherapy with a median survival time of $112{\pm}144.0$ days. Conclusions: This retrospective study showed improved overall survival time, loco regional control rates and reduced morbidity in patients treated with radical radiotherapy when compared to patients treated with palliative radiotherapy.

Developing Analysis Model of Hydraulic System for Dental Chair (치과용 유니트체어 유압구동 시스템 해석모델 개발)

  • Dae Kyung Noh;Dong Won Lee;Taek June Kim;Joo Sup Jang
    • Journal of Drive and Control
    • /
    • v.20 no.1
    • /
    • pp.27-33
    • /
    • 2023
  • From the perspective of dental chair manufacturers, it is important to of localizing hydraulic system in order to secure market competitiveness. This study aims to develop the analysis model of a dental chair which overseas companies secure core technologies. The study follows the steps below. First, the component parts of the solenoid valve unit of a foreign leading company are analyzed and implemented in virtual environment. Second, dynamic behavior scenario is established based on solenoid valve signal chart provided by a foreign leading company. The analysis model is verified and its performance is analyzed using dynamic behavior according to each scenario. Third, a simulation is carried out to determine whether the cylinder velocity of designed hydraulic system surpasses 1cm/s as required by the design.

Oil Leak Analysis using Simulation Model of Hydraulic System for Dental Chair (치과용 유니트체어 유압구동 시스템 해석모델을 활용한 누유량 분석)

  • Dae Kyung Noh;Dong Won Lee;Jae Yong Kim;Joo Sup Jang
    • Journal of Drive and Control
    • /
    • v.20 no.4
    • /
    • pp.35-44
    • /
    • 2023
  • This study aimed to analyze the performance of hydraulic systems for dental chair when long working hours makes the temperature of hydraulic fluid rise. The study was carried out in the following manner. First, 'cylinder's clearance' was reflected in the three kinds of hydraulic circuits, which were developed through the preceding study, in order to analyze oil leak. Second, 12 cases of simulations comprised of the up and down of cylinders were carried out. Third, it was determined whether the cylinder velocity of dental chair surpasses 1cm/s required in the development even in the hydraulic fluid temperature of 60℃. In conclusion, this study used SimulationX to verify the performance stability at high temperatures using three types of hydraulic circuits designed to develop a Korean unit chair.

Chair side measuring instrument for quantification of the extent of a transverse maxillary occlusal plane cant

  • Naini, Farhad B.;Messiha, Ashraf;Gill, Daljit S.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.21.1-21.3
    • /
    • 2019
  • Background: Treatment planning the correction of a transverse maxillary occlusal plane cant often involves a degree of qualitative "eyeballing", with the attendant possibility of error in the estimated judgement. A simple chair side technique permits quantification of the extent of asymmetry and thereby quantitative measurements for the correction of the occlusal plane cant. Methods: A measuring instrument may be constructed by soldering the edge of a stainless steel dental ruler at 90° to the flat surface of a similar ruler. With the patient either standing in natural head position, or alternatively seated upright in the dental chair, and a dental photographic retractor in situ, the flat under-surface of the horizontal part of this measuring instrument is placed on a unilateral segment of a bilateral structure, e.g. the higher maxillary canine orthodontic bracket hook. The vertical ruler is held next to the contralateral canine tooth, and the vertical distance measured directly from the canine bracket to the flat under-surface of the horizontal part of the measuring instrument. Results: This vertical distance quantifies the overall extent of movement required to level the maxillary occlusal plane. Conclusions: This measuring instrument and simple chair side technique helps to quantify the overall extent of surgical levelling required and may be a useful additional technique in our clinical diagnostic armamentarium.

A STUDY ON THE ILLUMINATION OF DENTAL CLINIC (치과 진료실의 조명에 관한 실태 조사연구)

  • Choi Jong-In;Kim Yu-Lee;Dong Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.4
    • /
    • pp.374-382
    • /
    • 2006
  • Purpose: This study was designed to investigate the present conditions of illumination techniques in dental clinics in order to contribute improvement of operating environment. This study also aimed exploring qualitative and quantitative luminous intensity required for color temperature in dental clinic illumination, which was a critical part of esthetic dentistry. Materials and methods: A total of forty-eight local dental clinics were selected for sampling a) luminous intensity, and b) color temperature. The author measured the luminous intensity and the color temperature with lux meter and color meter respectively between 12pm and 2pm. The dental unit chair placed in the general operation positions were kept the distance 60 cm then all dental units were measured three times and averaged. The author measured the luminous intensity and color temperature with both common dental operating light and then without operating light in different office environments. The study was conducted under three conditions: 1 artificial illumination in clear day light 2. artificial illumination in cloudy day light, and 3. artificial illumination alone. Results : The results obtained were as follows. 1. The average luminous intensity in dental clinic lighting was 425 lux which was not sufficient to produce the optimal shade of the patient's teeth. Furthermore, the average luminous intensity even in full operating lighting was 9532 lux which fell short of the required level of 10,000 lux. 2. The average color temperature of all dental clinics surveyed was 5169 K which met the optimal range. However, only 33.3% fell in the correct region between 5,000-5,500 K as 25% were over 5,500 K and 41.6% were below 5,000 K. As a result, 66.7% were under insufficient color temperature conditions. 3. The dental unit chair placed next to a window, hence exposure to natural lighting, had significantly higher luminous intensity and color temperature compared to the dental unit chair which didn't have a window or natural lighting. 4. The data analysis revealed that only 6.3% of the dental clinic were met the standard of the average luminous intensity and color temperature.

Oral Cancer Awareness and Perception of Tobacco Use Cessation Counseling among Dental Students in Four Asian Countries

  • Halawany, Hassan Suliman;Jacob, Vimal;Abraham, Nimmi Biju;Al-Maflehi, Nassr
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.6
    • /
    • pp.3619-3623
    • /
    • 2013
  • Background: The scientific evidence relating to the burden of oral diseases attributable to tobacco use has been reviewed and the need for a well-structured dental teaching program concentrating on oral cancer education and tobacco cessation interventions has been emphasized. The aim of our study was to evaluate the awareness of oral cancer and perception of tobacco use cessation counseling among dental students at all study levels in India, Saudi Arabia, the United Arab Emirates, and Yemen. Materials and Methods: A structured, pre-tested, self-administered 15-item questionnaire was used to conduct a cross-sectional survey. Data analyses including percentages, frequency distributions and tests of chi-square were generated. Results: A total of 621 (97.6%) Indian, 493 (96.5%) Saudi, 194 (96.5%) Yemeni and 187 (98.4%) United Arab Emirates respondents recognized the association between oral cancer and cigarette smoking. Although more than 96% of the students surveyed recognized the association between oral cancer and cigarette smoking and about 55% reported cigarette smoking as one of the etiological factors of oral cancer, more than 66% of students who reported cigarette smoking as an etiological factor of oral cancer disagreed/strongly disagreed with all the statements concerning tobacco use cessation. Conclusions: A higher level of oral cancer awareness did not have a positive impact on the perception of tobacco use cessation counseling among the sample surveyed.

A simplified chair-side remount technique using customized mounting platforms

  • Chauhan, Mamta Devendrakumar;Dange, Shankar Pandharinath;Khalikar, Arun Narayan;Vaidya, Smita Padmakar
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.3
    • /
    • pp.170-173
    • /
    • 2012
  • Correct occlusal relationships are part of the successful prosthetic treatment for edentulous patients. Fabrication of complete dentures comprises of clinical and laboratory procedures that should be executed accurately for achieving success with fabricated dentures. Errors occurring during the clinical and laboratory procedures of a denture may subsequently lead to the occlusal errors in the final prosthesis. These occlusal errors can be corrected in two ways: i) in patient's mouth ii) by recording new centric relation and remounting dentures on an articulator. The latter method is more feasible because the mobility of denture base on the mucosa in oral cavity does not permit the identification of premature contacts in centric occlusion and tooth guided eccentric excursions. This article describes a modest and effective clinical chair-side remount procedure using customized mounting platforms.