• Title/Summary/Keyword: Dental casts

Search Result 185, Processing Time 0.028 seconds

Accuracy of casts produced from conventional and digital workflows: A qualitative and quantitative analyses

  • Abduo, Jaafar
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.2
    • /
    • pp.138-146
    • /
    • 2019
  • PURPOSE. Comparing the accuracy of casts produced from digital workflow to that of casts produced from conventional techniques. MATERIALS AND METHODS. Whole arch alginate (ALG) and polyvinyl siloxane (PVS) impressions were taken with stock trays and custom trays, respectively. The ALG impressions were poured with type III dental stone, while the PVS impressions were poured with type IV dental stone. For the digital workflow, IOS impressions were taken and physical casts were produced by 3D printing. In addition, 3D printed casts were produced from images obtained from a laboratory scanner (LS). For each technique, a total of 10 casts were produced. The accuracies of the whole arch and separated teeth were virtually quantified. RESULTS. Whole arch cast accuracy was more superior for PVS followed by LS, ALG, and IOS. The PVS and ALG groups were inferior in the areas more susceptible to impression material distortion, such as fossae and undercut regions. The LS casts appeared to have generalized errors of minor magnitude influencing primarily the posterior teeth. The IOS casts were considerably more affected at the posterior region. On the contrary, the IOS and LS casts were more superior for single tooth accuracy followed by PVS and ALG. CONCLUSION. For whole arch accuracy, casts produced from IOS were inferior to those produced from PVS and ALG. The inferior outcome of IOS appears to be related to the span of scanning. For single tooth accuracy, IOS showed superior accuracy compared to conventional impressions.

Evaluation of the accuracy of dental casts manufactured with 3D printing technique in the All-on-4 treatment concept

  • Hilin, Tas;Fatih, Demirci;Mesut, Tuzlali;Erkan, Bahce;Guler Yildirim, Avcu
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.6
    • /
    • pp.379-387
    • /
    • 2022
  • PURPOSE. The aim of this study is to compare the casts obtained by using conventional techniques and liquid crystal display (LCD) three-dimensional (3D) print techniques in the All-on-4 treatment concept of the edentulous mandibular jaw. MATERIALS AND METHODS. In this study, a completely edentulous mandibular acrylic cast (typodont) with bone-level implants placed with the Allon-4 technique served as a reference cast. In this typodont, impressions were taken with the conventional technique and dental stone casts were obtained. In addition, after scanning the acrylic cast in a dental laboratory scanner and obtaining the Standard Tessellation Language (STL) data, 3D printed casts were manufactured with a 3D printing device based on the design. The stone and 3D printed casts were scanned in the laboratory scanner and STL data were obtained, and then the interimplant distances were measured using Geomagic Control X v2020 (3D Systems, Rock Hill, SC, USA) analysis software (n = 60). The obtained data were statistically evaluated with one-way analysis of variance (ANOVA) and Tukey's pairwise comparison tests. RESULTS. As a result of the one-way ANOVA test, it was determined that the stone casts, 3D printed casts, and reference cast values in all distance intervals conformed to the normal distribution and these values had a significant difference among them in all distance intervals. In Tukey pairwise comparison test, significant differences were found between casts at all distance intervals. In all analyses, the level of significance was determined as .05. CONCLUSION. 3D printed casts obtained with a 3D LCD printing device can be an alternative to stone casts when implants are placed in edentulous jaws. [J Adv Prosthodont 2022;14:379-87]

THREE-DIMENSIONAL ANALYSIS OF THE NORMAL DENTITION AND EDENTULOUS MAXILLA OF KOREANS (한국인의 상악 유치악 치열 및 무치악 치조제에 관한 삼차원적 연구)

  • Kim Hyeong-Seop;Shin Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.191-203
    • /
    • 2005
  • Statement of problem. In Korea, the preliminary impression trays for dental and edentulous maxillae are manufactured on the base of the statistical value of Westerners. There had been less study on the dental and edentulous arches of Koreans. Purpose. The purpose of this study was to evaluate an average dental cast, preliminary impression trays, three-dimensional relation of dental and edentulous maxilla of Koreans Material and methods. The subjects for this study were 173 dental casts of maxilla (dental: 52, edentulous : 146) with ages $18\{\sim}60$ years old. Each of the master casts was measured 69 measuring points on the dental cast or maxilla, and 46 measuring points on the edentulous cast of maxilla with three-dimensional digital measuring machine. Each measuring points were analysed and were overlapped, that three dimensional dental graphic manufactured by CAD/CAM system. Results. 1. A standard of distribution to alveolar bone were width between left and right buccal border lines of the standard 3/4 line. The mean value of dental and edentulous casts were 67.27mm, 63.49mm respectively. 2. Morphological classification of dental casts were divided into three groups or V-shape, O-shape, U-shape, that proportion of distribution were 17%, 16%, 67%, respectively. Dimensional classification of the dental casts were divided into five groups of less than 63mm, 63 up to 65mm, 65 up to 67mm. 67 up to 69mm, more than 69mm, respectively. 3. Morphological classification of edentulous casts were divided into three groups or V-shape, O-shape, U-shape, that proportion of distribution were 18%, 17%, 65%, respectively Dimensional classification of the edentulous casts were divided into five groups of less than 57mm, 57 up to 61mm, 61 up to 65mm, 65 up to 69mm, more than 69mm, respectively. 4. Mean dental and edentulous cast of maxilla were overlapped, the proportion of bone resorption to alveolar bone is higher than that of palatal bone, its difference were higher anterior 2/4 area than posterior 3/4 area. Conclusion. It obtains information of preliminary impression trays for dental and edentulous maxilla of Koreans.

Development of Dental Scanning System and Reproduction of Adjustable Upper Dental Impression Tray (치과용 스캐닝 시스템의 개발과 가변형 상악용 트레이의 재현성)

  • Cha, Young-Youp;Eom, Sang-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.3
    • /
    • pp.300-304
    • /
    • 2010
  • This study was performed to development a dental three-dimensional laser scanning system and measure the accuracy of new adjustable upper dental impression tray. The metal stock, individual, and new adjustable stock trays were used for 30 stone casts(10 casts each) duplicated a resin master model of maxilla. The dental stone was poured in a vinyl polysiloxane impressions and allowed to set for on hour. The master model and the duplicated casts were digitized using an dental scanning system. The distance between the reference points were measured and analyzed on the graphic image of 3D graphic software of CATIA. The statistical significance of the differences between the groups was determined by a two-way ANOVA. There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch. The adjustable upper stock tray showed clinically acceptable accuracies of the study cast produced by them.

A STASTICAL STUDY OF DENIAL CROWDING AND ITS RELATIONSHIP TOOTH SIZE, AND ARCH DIMENSION AND SHAPE (치아의 밀집(Crowding)에 영향을 주는 치아 및 악궁의 크기와 형태에 관한 통계학적 연구)

  • Choi, Young-Ju;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.14 no.2
    • /
    • pp.263-272
    • /
    • 1984
  • This study was undertaken to examine the extent to which tooth size and jaw size each contribute to dental crowding. Two groups of dental casts were selected on the basis of dental crowding. One group, consisting of 94 pairs of dental casts (46 males and 48 females) with normal occlusion. A second group, consisting of 84 pairs of dental casts (98 males and 46 females) with crowding. The results were as follows. 1. Means and standard deviations of the two groups were used to compare the two groups. 2. Significant differences were observed between two groups on the basis of tooth size, arch dimension and arch perimeter. 3. Between noncrowded group and crowded group, was crowded group was found to have large troth size than noncrowded group, while smaller arch dimension and perimeter. 4. Significant differences were observed between males and females on the basis of tooth size, arch dimension and arch perimeter. 5. Author found ideal arch shape of normal occlusion.

  • PDF

A Study on Castability and Roughness of the Casts Using Non-precious Alloys (비귀금속 합금을 이용한 주조체의 주조성과 Roughness에 관한 연구)

  • Kim, Jang-Ju
    • Journal of Technologic Dentistry
    • /
    • v.20 no.1
    • /
    • pp.5-11
    • /
    • 1998
  • The purpose of this study is to evaluate the castability and surface roughness of the casts using Non-percious alloys. For samples of 25 wax patterns, it is made from eight layers of sheet wax, arranged in the escalating layers. After fabricated wax patterns, using 5 kinds of Ni-Cr alloys is casted, and the casts are sandblasted. To castability, magnifier is used and values of surface roughness of the casts is measured with profilometer(tracing length 1.75mm, cutoff value 0.25mm) The results are as follows : 1. The castanbility of alloys, in case of C alloys, showed with $8.0{\pm}0.0000$, and in case of CS alloys and N alloys showed equal with $7.8{\pm}0.4472$, respectively. T alloys and V alloys showed equal with $7.2{\pm}0.4472$, respectively. 2. The values of surface roughness of the casts are decreased more T alloys than in case of order alloys, and in order, increased in case of CS alloys, C alloys, V alloys, N alloys, respectively.

  • PDF

A STUDY ON THE RELATIONSHIP BETWEEN TOOTH SIZE AND ARCH DIMENSION IN DENTAL CROWDING (Crowding에서 치아크기와 치열궁크기와의 관계에 대한 연구)

  • Lee, Jin-haeng;Lee, Dong-Joo
    • The korean journal of orthodontics
    • /
    • v.18 no.1 s.25
    • /
    • pp.217-225
    • /
    • 1988
  • This study was undertaken to examine relationship between tooth size and arch dimension in dental crowding. Two groups of dental casts were selected on the basis of dental crowding. One group, consisting of 51 pairs of dental casts (24 male and 27 female), exhibited remarkable dental crowding. A second group, consisting of 60 pairs of dental casts (30 male and 30 female), exhibited little or no crowding. Mean and standard deviation of the following parameters were used to compare two groups. individual and collective mesiodistal tooth diameters, buccal and lingual arch widths and arch area. The following results were obtained. 1. The crowed group revealed larger tooth size than noncrowded group. (p < 0.01) 2. The crowded group smaller maxillary dental arch dimension than noncrowded group except lingual arch width at canine region. (p < 0.01) 3. The corwded group revealed smaller mandibular dental arch dimension than noncrowded group except lingal arch width at second premalar region in the male and buccal arch width at canine, premolar region in the female. (p < 0.01) 4. The crowded group revealed smaller arch area than noncrowded group in the female (p < 0.01), but there was no significance in the male.

  • PDF

Accuracy of Stone Cast Produced by Adjustable Dental Impression Tray (가변형 치과 인상용 트레이로 제작된 모형의 재현성)

  • Park, Kwang-Su;Dong, Jin-Keun;Sim, Hun-Bo;Oh, Sang-Chun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.4
    • /
    • pp.317-328
    • /
    • 2006
  • Purpose: This study was performed to measure the accuracy of adjustable dental impression trays by a scanning laser three-dimensional digitizer. Materials and Methods: Metal stock tray and adjustable stock trays were used for 40 stone casts(10 casts each) duplicated a resin master model of mandible and maxilla. The type IV dental stone was poured in a allginate impressions and allowed to set for one hour. The casts were digitized using an optical digitizer. The distance between the reference points were measured and analyzed on the graphic image of 3-D graphic software (CATIA version 5.0). The statistical significance of the differences between the groups was determined by a two-way ANOVA. Results: There were no significant differences between the accuracies of the adjustable stock tray and the master model except anterior arch width of the upper arch and the diagonal arch length and arch length(one side) of the lower arch. Conclusion: The adjustable stock trays showed clinically acceptable accuracies of the study casts produced by them.

A STUDY ON THE CONTACT ANGLE AND WETTABILITY OF THE DENTAL STONES (수종 치과용 석고의 접촉각 및 젖음성에 관한 비교 연구)

  • Cho Lee-Ra;Chung Kyung-Ho;Kim Kyoung-Nam
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.1
    • /
    • pp.61-70
    • /
    • 2003
  • The purpose of this study was to investigate the contact angles and wettability of conventional dental stones and improved dental stones and newly developed dental stones on several impression materials. Materials included in this study were several dental stones and newly developed dental stone ; 2 type III stones (Snow Rock, New Diastone), 6 type IV stones(Crystal Rock, Vel Mix, Fuji Rock, Tuff Rock, Resin Rock and newly developed dental stone) and 1 type V stone (Die Keen). Contact angles on the impression materials were measured with contact angle measuring device. Ten specimens for each material, total 180 specimens were made on void entrapment model. The two impression materials (Handae, GC) were used to produce 9 groups of die stone casts form void entrapment model. Voids in the stone casts were counted under a stereoscopic microscope. The grad for the reproduction ability of each materials on the void entrapment model was calculated from the casts by one examiner. From the experiment, the following results were obtained : 1. The newly developed stones showed smallest contact angle. Type III dental stone had larger contact angles than type IV and V stones. Contact angle was much affected by the impression materials. 2. Resin containing die materials such as Tuff Rock and Resin Rock had smallest void number than any other groups. 3. In comparing reproduction parameters, Tuff Rock and Resin Rock presented superior results, while Vel Mix showed lowest reproduction ability.