• Title/Summary/Keyword: Dental block

검색결과 350건 처리시간 0.025초

Dentin Matrix Block의 치조골 복원 능력에 관한 임상적 연구 (Clinical Study on the Alveolar Bone Repair Capacity of Dentin Matrix Block)

  • 김경욱
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제35권1호
    • /
    • pp.55-59
    • /
    • 2013
  • In the oral and maxillofacial area, bone defects are created by various reasons and demand for bone grafts, while dental implant implantation has been increased consistently. To solve these problems, there has been development of autogenous tooth-bone graft material (AutoBT$^{(R)}$, Korea Tooth Bank Co., Korea), and we have collected ground reasons to substitute free autobone graft with this material in clinical use. This autogenous tooth-bone graft material is produced in powder type and block type. Block type is useful in esthetic reconstruction of the defect site and vertical and horizontal augmentation of alveolar bone because this type has high strength value, well maintained shape and is less absorbed. Therefore, the author of this study gained favorable result by grafting the block type autogenous tooth-bone graft material after dental implant implantation on the bone defects of the mandibular molar extraction site. Moreover, the author represents this case with literature review after confirming bone remodeling on the computed tomography image and by histological analysis.

Influence of different universal adhesives on the repair performance of hybrid CAD-CAM materials

  • Demirel, Gulbike;Baltacioglu, Ismail Hakki
    • Restorative Dentistry and Endodontics
    • /
    • 제44권3호
    • /
    • pp.23.1-23.9
    • /
    • 2019
  • Objectives: The aim of this study was to investigate the microshear bond strength (${\mu}SBS$) of different universal adhesive systems applied to hybrid computer-aided design/computer-aided manufacturing (CAD-CAM) restorative materials repaired with a composite resin. Materials and Methods: Four types of CAD-CAM hybrid block materials-Lava Ultimate (LA), Vita Enamic (VE), CeraSmart (CS), and Shofu Block HC (SH)-were used in this study, in combination with the following four adhesive protocols: 1) control: porcelain primer + total etch adhesive (CO), 2) Single Bond Universal (SB), 3) All Bond Universal (AB), and 4) Clearfil Universal Bond (CU). The ${\mu}SBS$ of the composite resin (Clearfil Majesty Esthetic) was measured and the data were analyzed using two-way analysis of variance and the Tukey test, with the level of significance set at p < 0.05. Results: The CAD-CAM block type and block-adhesive combination had significant effects on the bond strength values (p < 0.05). Significant differences were found between the following pairs of groups: VE/CO and VE/AB, CS/CO and CS/AB, VE/CU and CS/CU, and VE/AB and CS/AB (p < 0.05). Conclusions: The ${\mu}SBS$ values were affected by hybrid block type. All tested universal adhesive treatments can be used as an alternative to the control treatment for repair, except the AB system on VE blocks (the VE/AB group). The ${\mu}SBS$ values showed variation across different adhesive treatments on different hybrid CAD-CAM block types.

Successful use of Gasserian ganglion block for maxillo-mandibular fixation in a patient with severe pulmonary dysfunction-a case report

  • Vadhanan, Prasanna
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제20권5호
    • /
    • pp.331-335
    • /
    • 2020
  • Various anesthetic techniques have been utilized for maxillo-mandibular fixation. We report the case of a patient with bilateral condylar and zygomatic arch fractures who had severe pulmonary dysfunction. The patient was administered bilateral image-guided Gasserian ganglion block through the foramen ovale to achieve surgical anesthesia. The technical details, advantages, and disadvantages of this rather unusual technique are discussed. The procedure could be a feasible technique when performed meticulously in cases where other approaches are deemed difficult.

스크래치 시험을 이용한 치과용 지르코니아 블록의 가공성 연구 (Processability study of dental zirconia block using scratch test)

  • 김영훈
    • 대한치과기공학회지
    • /
    • 제40권1호
    • /
    • pp.27-32
    • /
    • 2018
  • Purpose: This study was performed to investigate processability of the dental zirconia block. Most of the CAD/CAM zirconia restorations utilize the partially sintered blocks, which are sintered at a temperature lower than $1100^{\circ}C$. Methods: Partially sintered zirconia samples were prepared $40{\times}30{\times}10mm$ and surface treatment by #2000 sandpaper. Scratch hardness was determined by the procedure of ASTM G171-03 using a scratch hardness tester(KS TECH, Korea) equipped with a real time load detector to measure tangential force during scratching. The scratch rate was 30 mm/min. Results: Scratch hardness(Hs) increases steeply with increase in the loads. The highest Hs was sampl 1.42 GPa and lowest was sample 0.42 GPa. Conclusion : The machinability of partially sintered CAD/CAM zirconia blocks can be optivized by manipulation of Hs.

이열 하악관(Bifid Mandibular Canal): 방사선적 소견과 임상적 의의 -증례보고- (Bifid Mandibular Canal: Radiographic Observation and Clinical Relevance -A Case Report-)

  • 이현우;김여갑;이백수;권용대;최병준;김영란
    • 대한치과마취과학회지
    • /
    • 제9권1호
    • /
    • pp.24-29
    • /
    • 2009
  • When performing the inferior alveolar nerve block anesthesia, surgeon often faced a difficulty of the surgical operation due to the incomplete anesthesia. One of the reason is the variety of mandibular canal anatomy. Up to now, there are some reports of index cases about bifid mandibular canal among mandibular canal anatomic variation, and some classification is applied according to anatomical location and configuration. When surgical operation is performed involving mandible such as dantal implant treatment, extraction of an impacted third molar, sagittal split ramus osteotomy, etc, the position of mandibular canal should be considered. Bifid mandibular canal clinically causes troublesome cases of anesthesia when inferior alvelor nerve block, especially is performed extraction of an impacted third molar. Therefore, It is important for clinicians to recognize the presence of bifid canals on radiographys. Nowadays, the position of mandibular canal can be measured precisely by using Dental CT. It is not found by panorama image but is found by Dental CT sometimes. Among the patients, which take panorama and Dental CT simultaneously, for tooth extraction of lower impacted third molar in our department, we report the case that did not identifying in panorama but identifying it in Dental CT.

  • PDF

ShadeEye$^{(R)}$ NCC system을 이용한 Vita CAD/CAM Ceramic Block의 크기에 따른 색조 일치성 비교연구 (Comparative Study of Color Correspondence According to Size of Vita CAD/CAM Ceramic Block Using ShadeEye-Ncc$^{(R)}$ System)

  • 김재홍;김혜영;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제33권3호
    • /
    • pp.203-210
    • /
    • 2011
  • Purpose: The purpose of this study was to compare color correspondence of different sizes of Vita Mark II$^{(R)}$ and TriLuxe$^{(R)}$ Feldspar blocks. Methods: The three commercially available shades(1M2, 2M2, 3M2) of Mark II & TriLuxe blocks for the CEREC$^{(R)}$ CAD/CAM system were examined. For each of three colors, three different sizes were tested, 5 blocks each. The measurements were made using a spectrophotometer equipped with an integrating sphere using the CIE $L^*$, $a^*$, $b^*$ colorimetric system. Results: The $L^*$, $a^*$, $b^*$ value of Vita Mark II$^{(R)}$ ceramic block showed significantly higher than TriLuxe$^{(R)}$ ceramic block(p<0.05). In comparing the Vita Mark II$^{(R)}$ specimen of the three different shade, color differences between materials(${\Delta}E^*$) showed the lowest value of 2.09, and the highest was 2.24. ${\Delta}E^*$ values of the materials of Vita Mark II$^{(R)}$ were higher than 2. As the size of ceramic block differed, the color correspondence of Vita Mark II$^{(R)}$ showed statistically significant difference but, this result is clinically acceptable. Conclusion: All the different sizes of the different shades of Vita TriLuxe$^{(R)}$ blocks for the CEREC$^{(R)}$ system showed the high degree of color correspondence necessary in industrially prefabricated CAD/CAM blocks. The results of the present study suggested that it would be necessary to establish the reproducible and constant color specification system for an esthetic restoration.

Articaine (4%) with epinephrine (1:100,000 or 1:200,000) in inferior alveolar nerve block: Effects on the vital signs and onset, and duration of anesthesia

  • Lasemi, Esshagh;Sezavar, Mehdi;Habibi, Leyla;Hemmat, Seyfollah;Sarkarat, Farzin;Nematollahi, Zahra
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제15권4호
    • /
    • pp.201-205
    • /
    • 2015
  • Background: This prospective, randomized, double-blind, clinical study was conducted to compare the effects of 4% articaine with 1:100,000 epinephrine (A100) and 4% articaine with 1:200,000 epinephrine (A200) on the vital signs and onset and duration of anesthesia in an inferior alveolar nerve block (IANB). Methods: In the first appointment, an IANB was performed by injecting A100 or A200 in 1 side of the mouth (right or left) randomly in patients referred for extraction of both their first mandibular molars. In the second appointment, the protocol was repeated and the other anesthetic solution was injected in the side that had not received the block in the previous session. Systolic and diastolic blood pressures (SBP and DBP) and pulse rate were measured during and 5 min after the injection. The onset and duration of anesthesia were also evaluated. Data were analyzed using t-test and Mann-Whitney U-test, and p-value was set at 0.05. Results: SBP and pulse rate changes were slightly more with A100; however, DBP changes were more with A200, although the differences were not significant (P > 0.05). There were no statistically significant differences in the parameters evaluated in this study. The onset and duration of anesthesia, and the changes in SBP, DBP, and pulse rate during and 5 min after the injection were the same in both the groups. Conclusions: For an IANB, A200 and A100 were equally efficient and successful in producing the block. Epinephrine concentration did not influence the effects of 4% articaine.

치과용 생체보철물 제작을 위한 TZP 단일구조 전부도재관 블럭의 물성과 저온열화 후 굴곡강도에 관한 연구 (The research about the physical properties and flexural strength changed by Low Temperature Degradation of TZP monolithic all-ceramic crown block to make bio-prosthetic dentistry)

  • 이종화;박천만;송재상;임시덕;김재도;김병식;황인환;이성국
    • 대한치과기공학회지
    • /
    • 제34권2호
    • /
    • pp.83-93
    • /
    • 2012
  • Purpose: The objective of this study is to find out physical properties and the flexural strength changed by the low temperature degradation of the block which is needed to make bio-prosthetic dentistry which is better than feldspar affiliated ceramic made by building up ceramic powder and also to apply this to the clinical use of zirconia monolithic all-ceramic crown. Methods: Flexural strength of each sample was evaluated before and after the Low Temperature Degradation, and physical properties of the Tetra Zirconia Block containing 3mol % was evaluated as well. The average and standard deviation of each experimental group were came out of the evaluation. Statistical package for social science 18.0 was used for statistics. Results: The average density of the monolithic all-ceramic crown was $6.0280{\pm}0.0147g/cm$, the relative density was 99.01 %. When the sample was sintered at $1480^{\circ}C$ the diameter of average particle was $396.62{\pm}33.71nm$. All the samples had no monolithic peak after XRD evaluation but only had tetragonal peak. There were statistically significant differences in the result of flexural strength of the samples evaluated after and before the low temperature degradation, the flexural strength before the low temperature degradation was $1747.40{\ss}{\acute{A}}$, at the temperature of $130^{\circ}C$ the flexural strength after the low temperature degradation was 1063.99MPa (p<0.001). There was statistically significant difference in the result of strength of 1020.07MPa after the low temperature degradation at the temperature of $200^{\circ}C$ (p<0.001). Conclusion: The block which was made for this evaluation possesses such an excellent strength among dental restorative materials that it is thought to have no problems to use for tetragonal zirconia polycrystal.