• Title/Summary/Keyword: Dental arch shape

Search Result 53, Processing Time 0.017 seconds

Effect of image matching experience on the accuracy and working time for 3D image registration between radiographic and optical scan images (술자의 영상정합의 경험이 컴퓨터 단층촬영과 광학스캔 영상 간의 정합 정확성과 작업시간에 미치는 영향)

  • Mai, Hang-Nga;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.299-304
    • /
    • 2021
  • Purpose. The purpose of the present study was to investigate the effects of image matching experience of operators on the accuracy and working time of image registration between radiographic and optical scan images. Materials and methods. Computed tomography and optical scan of a dentate dental arch were obtained. Image matching between the computed tomography and the optical scan (IDC S1, Amann Girrbach, Koblah, Austria) was performed using the point-based automatic registration method in planning software programs (Implant Studio, 3Shape, Copenhagen, Denmark) using two different experience conditions on image registration: experienced group and inexperienced group (n = 15 per group, N = 30). The accuracy of image registration in each group was evaluated by measuring linear discrepancies between matched images, and working time was recorded. Independent t test was used to statistically analyze the result data (α = .05). Results. In the linear deviation, no statistically significant difference was found between the experienced and inexperienced groups. Meanwhile, the working time for image registration was significantly shorter in the experienced group than in the inexperienced group (P = .007). Conclusion. Difference in the image matching experience may not influence the accuracy of image registration of optical scan to computed tomography when the point-based automatic registration was used, but affect the working time for the image registration.

Conceptual Design of the Three Unit Fixed Partial Denture with Glass Fiber Reinforced Hybrid Composites (Glass fiber 강화 복합레진을 사용한 3본 고정성 국소의치의 개념 설계 연구)

  • Na, Kyoung-Hee;Lee, Kyu-Bok;Jo, Kwang-Hun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.18 no.3
    • /
    • pp.145-155
    • /
    • 2002
  • The results of the present feasibility study are summarized as follows, 1. The three unit bridge of knitted material and UD fibre reinforcement has both the rigidity and the strength against a vertical occlusal load of 75N. 2. Stress concentration at the junctional area between the bridge and the abutments, i.e. between the pontic and the knitted caps was observed. In the case of the bridge with reinforcement straps, it was partly shown that the concentration problem could be improved by simply increasing the fillet size at the area. Further refining in the surface of the junctional area will be needed to ensure a further improvement in the stress distribution. This will require some trade off in the level of the stress and the available space. A parametric study will help to decide the appropriate size of the fillet. 3. Design refinement is a must to improve the stress distribution and realize the most favourable shape in terms of fabrication. The current straight bar with a constant cross section area can be redesigned to a tapered shape. The curve from the dental arch should also be placed on the pontic design. In accordance with design refinement, the resistance of the bridge frame to other load cases should be evaluated. 4. Although not included in the present feasibility study, it is estimated that bridges of the anterior teeth can be made strong enough with the knitted material without further reinforcement using unidirectional materials. In this regard, a feasibility study on design concepts and stress analysis for 3, 4, 5 unit bridge is suggested. 5. Two types of bridge were analysed in terms of fatigue. The safe life design concept, i.e. fatigue design concept, looks reasonable for the bridge where if cracks should form and propagate there is virtually nothing a dentist to do. The bridge must be designed so that no crack will be initiated during the life span. In the case of crowns, however, if constructed with composite resin with knitted materials, it might be possible to repair them, which in general is impossible for crowns of PFM or of metal. Therefore for composite resin crowns, a damage tolerance design concept can be applied and reasonably higher operational stresses can be allowed. In this case, of course, a periodic inspection program should be established in parallel. 6. Parts of future works in terms of structural viewpoint which need to be addressed are summarized as the following: 1) To develop processing technology to accommodate design concepts; 2) More realistic modelling of the bridge and analysis-geometry and loading condition. Thickness variation in the knitted material, taper in the pontic, design for anterior tooth bridge, the effect of combined loads, etc, will need to be included; 3) To develop appropriate design concepts and design goals for the fibre composite FPD aiming at taking the best advantage of knitted materials, including the damage tolerance design concept; 4) To develop testing method and perform test such as static ultimate load test, fatigue test, repair test, etc, as necessary.

THE BONE CHANGES OF THE MIDPALATAL SUTURE AFTER RAPID PALATAL EXPANSION IN YOUNG ADULT DOGS (유성견에서 상악골 급속확장 후 정중구개봉합부에서의 골조직 변화)

  • Park, Chang-Wook;Yoon, Young-Jooh;Kim, Kwang-Won
    • The korean journal of orthodontics
    • /
    • v.27 no.3 s.62
    • /
    • pp.391-399
    • /
    • 1997
  • Rapid palatal expansion(RPE) is a method of inducing the new bone formation in the palate by separation of the midpalatal suture, which can be done conveniently by placing heavy force across the maxillary dental arch. This experiment was undertaken to examine the histologic changes after RPE and during retention period. Four young adult dogs(a control dog, three experimental dogs) aged 4 to 6 months old were used for this experiment. Expansion screw($Hyrax^{\circledR}$, Dentarum Inc.) was delevered to the palate and fumed 180 degrees every morning and evening for 8 days, giving a total expansion of 7.2mm. A control dog was sacrified at the starting point of this study without any treatment and three experimental dogs were sacrified after RPE, 14-day retention, and 28-day retention in each. Thereafter, those samples were observed with hematoxylin-eosin(H-E) stain, ground section(Villanueva stain), alkaline phosphatase(ALP) stain, tartrate-resistant acid phosphatase(TRA) stain. The results were as followings: 1. After RPE, collagen fiber bundles were stretched along the midpalatal suture and few osteoblasts were flattened-inactive state and also, a little osteoid tissues was observed. Few multinucleated osteoclasts which had TRAP-positive activity in their cytoplasm were seen in horizontal section, whereas a few osteoclasts were seen in frontal section, especially in the nasal floor side of palatal bone. 2. After 14-day retention, collagen fiber bundles were stretched along the midpalatal suture and few osteoblasts which had ALP-positive activity in their cytoplasm were seen. Few multinucleated osteoclasts which had TRAP-positive activity in their cytoplasm were seen in horizontal section, whereas a few osteoclasts were seen in frontal section, especially in the nasal floor side of palatal bone. 3. After 28-day retention, collagen fiber bundles were arranged like those of control dog and osteoblasts which showed a lot of immature bone formation were cuboidal shape and exhibited ALP-positive activity in their cytoplasm. Few multinucleated osteoclasts which had TRAP-positive activity in their cytoplasm were seen in horizontal section, whereas a few osteoclasts were seen in frontal section, especially in the nasal floor side of palatal bone. According to the above results, the new bone formation after rapid palatal expansion was examined after 14-day retention and significantly increased after 28-day retention.

  • PDF