• 제목/요약/키워드: Dental Radiography

검색결과 509건 처리시간 0.025초

A dose monitoring system for dental radiography

  • Lee, Chena;Lee, Sam-Sun;Kim, Jo-Eun;Symkhampha, Khanthaly;Lee, Woo-Jin;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul;Yeom, Heon-Young
    • Imaging Science in Dentistry
    • /
    • 제46권2호
    • /
    • pp.103-108
    • /
    • 2016
  • Purpose: The current study investigates the feasibility of a platform for a nationwide dose monitoring system for dental radiography. The essential elements for an unerring system are also assessed. Materials and Methods: An intraoral radiographic machine with 14 X-ray generators and five sensors, 45 panoramic radiographic machines, and 23 cone-beam computed tomography (CBCT) models used in Korean dental clinics were surveyed to investigate the type of dose report. A main server for storing the dose data from each radiographic machine was prepared. The dose report transfer pathways from the radiographic machine to the main sever were constructed. An effective dose calculation method was created based on the machine specifications and the exposure parameters of three intraoral radiographic machines, five panoramic radiographic machines, and four CBCTs. A viewing system was developed for both dentists and patients to view the calculated effective dose. Each procedure and the main server were integrated into one system. Results: The dose data from each type of radiographic machine was successfully transferred to the main server and converted into an effective dose. The effective dose stored in the main server is automatically connected to a viewing program for dentist and patient access. Conclusion: A patient radiation dose monitoring system is feasible for dental clinics. Future research in cooperation with clinicians, industry, and radiologists is needed to ensure format convertibility for an efficient dose monitoring system to monitor unexpected radiation dose.

Brazilian young dental practitioners' use and acceptance of digital radiographic examinations

  • Rovaris, Karla;de Faria Vasconcelos, Karla;do Nascimento, Eduarda Helena Leandro;Oliveira, Matheus Lima;Freitas, Deborah Queiroz;Haiter-Neto, Francisco
    • Imaging Science in Dentistry
    • /
    • 제46권4호
    • /
    • pp.239-244
    • /
    • 2016
  • Purpose: The aim of this study was to investigate the use and acceptance of digital radiographic examinations by Brazilian dental practitioners in daily practice and to evaluate the advances that have occurred over the past 5 years. Materials and Methods: Dental practitioners enrolled in extension courses at the Piracicaba Dental School, University of Campinas, Brazil, responded to a self­administered questionnaire in the years 2011 and 2015. They were asked about sociodemographic factors and their knowledge and use of digital radiographic examinations. Descriptive analysis was performed, as well as the chi-square and Fisher exact tests, with a significance level of 5% (${\alpha}=0.05$). results: A total of 181 participants responded to the questionnaire in the years 2011 and 2015. Most of the respondents worked in private practice, had graduated within the last 5 years, and were between 20 and 30 years old. In 2011, 55.6% of respondents reported having ever used digital radiographic examinations, while in 2015 this number increased significantly to 85.4% (p<.0001), out of which 71.4% preferred it to conventional images. Moreover, 21.4% of respondents reported having used digital radiographic examinations for more than 3 years. A significant increase in use of intraoral digital radiography (p = 0.0316) was observed in 2015. In both years, image quality and high cost were indicated, respectively, as the main advantage and disadvantage of digital radiographic examinations. conclusion: This study showed that digital radiology has become more common in Brazil over the past 5 years. Most of the Brazilian dental practitioners evaluated in 2015 used digital radiographic examinations.

치과위생사의 방사선 피폭정도가 삶의 질에 미치는 영향 (The effect of occupational exposure on quality of life in dental hygienists)

  • 장종화;이혜남;임청환
    • 한국치위생학회지
    • /
    • 제10권4호
    • /
    • pp.717-725
    • /
    • 2010
  • Objectives : This study was to determine the level of occupational exposure and quality of life and to investigate the effect of variables related occupational exposure on quality of life in dental hygienists. Methods : A survey questionnaire was mailed to dental hygienists from April 4 to May 15, 2010. The subjects were 256(56.9%), who were worked in dental hospital and clinic with mean age of $29.59{\pm}7.30$. Quality of life was measured using the WHOQOL-BREF. It consists of 26 items, each with 5-point likert scale. Self control of occupational exposure was measured using the 3-items. The data were analyzed with chi-square, t-test, one-way ANOVA, pearson correlation coefficients and multiple regression using the SPSS WIN 17.0 program. Results : Regarding quality of life, the subjects was a mean of 90.73 out of a maximum 130 points. The level of self control occupational exposure a mean of 3.20 out of a maximum 5 points. Self control of occupational exposure, frequency of panorama radiography, work experience of radiography had a significant impact on quality of life in dental hygienists. Conclusions : Based on the findings, occupational exposure is negatively associated with quality of life in dental hygienists. These results suggest that health promotion program should be considered various factors related occupational exposure in dental hygienists.

Association between dental X-ray exposure and the thyroid cancer risk: A meta-analysis of case-control studies

  • Hwang, Su-Yeon;Kim, Hae-Young;Song, Sun-Mi;Choi, Eun-Sil
    • 한국치위생학회지
    • /
    • 제20권3호
    • /
    • pp.269-279
    • /
    • 2020
  • Objectives: Previous studies have reported inconsistent findings in the association between dental diagnostic X-ray exposure and thyroid cancer. This study was a meta-analysis of case-control studies evaluating the association between exposure to dental radiation and the thyroid cancer risk. Methods: We searched the PubMed and EMBASE databases to identify studies on dental radiation and thyroid cancer risks that were published up to September 2018. Quality of studies was assessed using the Newcastle-Ottawa scale. A fixed-effects model was used to estimate pooled odds ratios (ORs) and 95% confidence intervals (CIs) using STATA 14.0. Potential publication biases were evaluated using Egger's test and Begg's funnel plot. Results: From the literature search, we included six case-control studies in this meta-analysis. The meta-analysis using the fixed-effects model found that dental X-ray exposure was associated with 2.34 times increased risk for thyroid cancer (OR=2.34, 95% CI=1.79-3.21). There was no heterogeneity in the data (p=0.662, I2 =0%). Egger's test showed that there was no publication bias (p=0.532). Conclusions: This meta-analysis confirmed the association of dental X-ray exposure and thyroid cancer risk. The current results underscore the importance of applying safety regulations at dental clinics to protect thyroid glands during dental radiography examinations.

치과위생사의 이동형 구내방사선 촬영에 관한 방사선 방어 교육, 지식, 수행에 관한 연구 (A study on radiation safety education, knowledge, and practice in using portable intraoral X-ray equipment of dental hygienist's)

  • 유정민;강보선;김설희
    • 한국치위생학회지
    • /
    • 제17권6호
    • /
    • pp.1053-1065
    • /
    • 2017
  • Objectives: The purpose of this study is to evaluate radiation safety education, knowledge and practice of dental hygienists in using handheld portable intraoral X-ray equipment and to suggest the need for radiation safety education in using handheld portable intraoral X-ray equipment. Methods: We surveyed 223 dental hygienists from July, 2017 to August in the dental clinics of Daejeon, Seoul and Gyeonggi area. Results: Radiation safety educational experience was higher in a year's career (72.9%), than 3 years experience (32.5%) (p<0.05). 82.7% of dental clinic workers took university education for radiation safety education while 55.6% of dental hospital workers took company training (p<0.05). More than 70% of the subjects did not have experience of radiation safety education about using portable intraoral X-ray. Radiation safety knowledge was highest in a year's career (p<0.05). The cumulative dose, radiation sensitivity, and lead defense knowledge were high in all subjects, but knowledge related to scattering radiation and scattering radiation sources was low. Practice of portable intraoral X-ray safety was significantly lower than knowledge. Conclusions: Knowledge of portable intraoral radiography safety is available, but performance is poor. Even with the small amount of radiation exposure, the risk is perceivable. There is a need to actively utilize the provided radiation protection products. In order to do this, efforts should be made to improve knowledge and performance of radiation safety through not only college education but also postemployment training.

Usefulness of lateral cephalometric radiography for successful blind nasal intubation: a prospective study

  • Ito, Kana;Kamura, Ayaka;Koshika, Kyotaro;Handa, Toshiyuki;Matsuura, Nobuyuki;Ichinohe, Tatsuya
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제22권6호
    • /
    • pp.427-435
    • /
    • 2022
  • Background: This study aimed to investigate the relationship between pharyngeal morphology and the success or failure of blind nasotracheal intubation using standard lateral cephalometric radiography and to analyze the measurement items affecting the difficulty of blind nasotracheal intubation. Methods: Assuming a line perpendicular to the Frankfort horizontal (FH) plane, the reference point (O) was selected 1 cm above the posterior-most end of the hard palate. A line passing through the reference point and parallel to the FH plane is defined as the X-axis, and a line passing through the reference point and perpendicular to the X-axis is defined as the Y-axis. The shortest length between the tip of the uvula and posterior pharyngeal wall (AW), shortest length between the base of the tongue and posterior pharyngeal wall (BW), and width of the glottis (CW) were measured. The midpoints of the lines representing each width are defined as points A, B, and C, and the X and Y coordinates of each point are obtained (AX, BX, CX, AY, BY, and CY). For each measurement, a t-test was performed to compare the tracheal intubation success and failure groups. A binomial logistic regression analysis was performed using clinically relevant items. Results: The items significantly affecting the success rate of blind nasotracheal intubation included the difference in X coordinates at points A and C (Odds ratio, 0.714; P-value, 0.024) and the ∠ABC (Odds ratio, 1.178; P-value, 0.016). Conclusion: Using binomial logistic regression analysis, we observed statistically significant differences in AX-CX and ∠ABC between the success group and the failure group.

Common positioning errors in panoramic radiography: A review

  • Rondon, Rafael Henrique Nunes;Pereira, Yamba Carla Lara;do Nascimento, Glauce Crivelaro
    • Imaging Science in Dentistry
    • /
    • 제44권1호
    • /
    • pp.1-6
    • /
    • 2014
  • Professionals performing radiographic examinations are responsible for maintaining optimal image quality for accurate diagnoses. These professionals must competently execute techniques such as film manipulation and processing to minimize patient exposure to radiation. Improper performance by the professional and/or patient may result in a radiographic image of unsatisfactory quality that can also lead to a misdiagnosis and the development of an inadequate treatment plan. Currently, the most commonly performed extraoral examination is panoramic radiography. The invention of panoramic radiography has resulted in improvements in image quality with decreased exposure to radiation and at a low cost. However, this technique requires careful, accurate positioning of the patient's teeth and surrounding maxillofacial bone structure within the focal trough. Therefore, we reviewed the literature for the most common types of positioning errors in panoramic radiography to suggest the correct techniques. We would also discuss how to determine if the most common positioning errors occurred in panoramic radiography, such as in the positioning of the patient's head, tongue, chin, or body.

Accuracy of virtual 3-dimensional cephalometric images constructed with 2-dimensional cephalograms using the biplanar radiography principle

  • Lee, Jae-Seo;Kim, Sang-Rok;Hwang, Hyeon-Shik;Lee, Kyungmin Clara
    • Imaging Science in Dentistry
    • /
    • 제51권4호
    • /
    • pp.407-412
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the accuracy of virtual 3-dimensional (3D) cephalograms constructed using the principle of biplanar radiography by comparing them with cone-beam computed tomography (CBCT) images. Materials and Methods: Thirty orthodontic patients were enrolled in this study. Frontal and lateral cephalograms were obtained with the use of a head posture aligner and reconstructed into 3D cephalograms using biplanar radiography software. Thirty-four measurements representing the height, width, depth, and oblique distance were computed in 3 dimensions, and compared with the measurements from the 3D images obtained by CBCT, using the paired t-test and Bland-Altman analysis. Results: Comparison of height, width, depth, and oblique measurements showed no statistically significant differences between the measurements obtained from 3D cephalograms and those from CBCT images (P>0.05). Bland-Altman plots also showed high agreement between the 3D cephalograms and CBCT images. Conclusion: Accurate 3D cephalograms can be constructed using the principle of biplanar radiography if frontal and lateral cephalograms can be obtained with a head posture aligner. Three-dimensional cephalograms generated using biplanar radiography can replace CBCT images taken for diagnostic purposes.

임플란트 매식부의 고경 평가 : 파노라마 촬영법과 나선형 전산화 단층촬영법의 계측 비교 (Bone height measurements of implant sites : Comparison of panoramic radiography and spiral computed tomography)

  • 조봉혜
    • Imaging Science in Dentistry
    • /
    • 제32권2호
    • /
    • pp.61-66
    • /
    • 2002
  • Purpose: To compare the bone height of implant sites measured using panoramic radiography and spiral CT. Materials and Methods : The available bone height was determined for 263 maxillary and mandibular implant sites in 59 patients. Distortion was calculated using the metal bar for the panoramic radiographs. Results: Significant differences in mean bone height between the two imaging modalities were found in maxillary and mandibular anterior regions (p<0.05). The mean difference in bone height recorded by the two techniques was smallest in the maxillary and mandibular molar areas (0.8 mm), and greatest in the mandibular anterior region (1.3 mm). With the exception of the mandibular anterior region, ninety percent of all the sites showed measurement differences within 2 mm. Conclusion: A safety margin of 2 to 3 mm is called for when utilizing panoramic radiography, otherwise additional imaging modality such as computed tomography is necessary to obtain accurate measurements.

  • PDF