• 제목/요약/키워드: Dental Radiography

검색결과 509건 처리시간 0.023초

교합방사선사진 촬영시의 흡수선량 계측 (ESTIMATION OF ABSORBED DOSE IN OCCLUSAL RADIOGRAPHY)

  • 유영아;최갑식;이상한
    • 치과방사선
    • /
    • 제20권1호
    • /
    • pp.103-112
    • /
    • 1990
  • The purpose of this study was to estimate absorbed dose of each important anatomic site of phantom (RT-2l0 Head & Neck Section/sup R/, Humanoid Systems Co., U.S.A.) head in occlusal radiography. X-radiation dosimetry at 12 anatomic sites in maxillary anterior topography, maxillary posterior topography, mandibular anterior cross-section, mandibular posterior cross-section, mandibular anterior topographic, mandibular posterior topographic occlusal projection was performed with calcium sulfate thermoluminescent dosimeters under 70Kvp and 15mA, 1/4 second (8 inch cone) and 1 second (16 inch cone) exposure time. The results obtained were as follows: Skin surface produced highest absorbed dose ranged between 3264 mrad and 4073 mrad but there was little difference between projections. In maxillary anterior topographic occlusal radiography, eyeballs, maxillary sinuses, and pituitary gland sites produced higher absorbed doses than those of other sites. In maxillary posterior topographic occlusal radiography, exposed eyeball site and exposed maxillary sinus site produced high absorbed doses. In mandibular anterior cross-sectional occlusal radiography, all sites were produced relatively low absorbed dose except eyeball sites. In mandibular posterior cross-sectional occlusal radiography, exposed eyeball site and exposed maxillary sinus site were produced relatively higher absorbed doses than other sites. In mandibular anterior topographic occlusal radiography, maxillary sinuses, submandibular glands, and thyroid gland sites produced high absorbed doses than other sites. In mandibular posterior topographic occlusal radiography, submandibular gland site of the exposed side produced high absorbed dose than other sites and eyeball site of the opposite side produced relatively high absorbed dose.

  • PDF

치과방사선 검사 시 방사선작업종사자의 위치에 따른 방사선 노출 평가 (Radiation Exposure Evaluation Depending on Radiation Workers' Locations during Dental Radiography)

  • 정천수;김지영
    • 한국방사선학회논문지
    • /
    • 제9권7호
    • /
    • pp.433-438
    • /
    • 2015
  • 치과방사선 검사에 있어 방사선작업종사자의 위치에 따라 방사선 노출 정도를 평가하고자 촬영실과 납유리, 조작대에서 방사선량률을 측정하였다. 사용된 장치로는 Standard(Max-GLS, Shinhung), 파노라마(PCH-2500, Vatech), 세팔로(PCH-2500), Cone beam CT(PHT-30LFO, Vatech)이며, 방사선측정기는 PM1405 장비이다. 촬영조건은 임상에서 사용하는 인자와 동일하게 설정하였다. 그 결과 촬영실 안에서는 Cone beam CT가 98 uSv/h로 가장 높았으며, standard가 0.4 uSv/h로 가장 낮은 수치를 보였다. 또 파노라마가 촬영방식이 다름으로 인하여 세팔로 보다 높게 측정되었다. 납유리 표면과 조작대에서는 구강내와 파노라마, 세팔로는 모두 기록준위 이하로 측정되었지만, Cone beam CT는 누설선량이 있는 것으로 측정되었다. 이에 방사선작업종사는 적절한 방호도구를 하고 촬영시간을 최대한 줄여야 한다. 또, 방사선실의 구조 또한 효율적으로 설계해야 할 것이다. 치과방사선검사는 최근 지속적으로 증가하고 있기 때문에 환자와 방사선작업종사자에 대한 적절한 방호 대책이 필요하다.

파노라마방사선사진에서 석회화가 발견되는 경동맥의 협착 정도 (Stenosis of calcified carotid artery detected on Panoramic Radiography)

  • 조소양;오원만;윤숙자;윤웅;이재서;;강병철
    • Imaging Science in Dentistry
    • /
    • 제39권3호
    • /
    • pp.157-161
    • /
    • 2009
  • Purpose : This study aimed to investigate the luminal stenosis of the internal carotid artery with calcification detected on panoramic radiographs. Materials and Methods : This study used fifty carotid arteries of 36 dental patients whose panoramic radiograph and computed tomography angiography (CTA) revealed the presence of carotid artery calcification. A neuroradiologist interpreted CTA to determine the degree of stenosis of the internal carotid arteries. The degree of stenosis was stratified in four stages; normal (no stenosis), mild stenosis (1-49%), moderate stenosis (50-69%) and severe stenosis (70-99%). Results : Among the fifty carotid arteries with calcification detected on both panoramic radiography and CTA, 20 carotid arteries (40%) were normal, 29 carotid arteries (18%) had mild stenosis, 1 carotid artery (2%) had moderate stenosis, and there was none with severe stenosis. Conclusion : Sixty percent of the carotid arteries with calcification detected on both panoramic radiography and CTA had internal luminal stenosis, and two percent had moderate stenosis. When carotid atheroma is detected on panoramic radiograph, it is possible that the dental patient has luminal stenosis of the internal carotid artery.

  • PDF

Mandibular lateral incisor with four root canals: A unique case of double tooth diagnosed using multidetector computed tomography

  • Gupta, Sunil Kumar;Gupta, Jaya;Acharya, Shashi Rashmi;Ather, Amber
    • Imaging Science in Dentistry
    • /
    • 제43권2호
    • /
    • pp.123-128
    • /
    • 2013
  • Double tooth is a dental anomaly consequent to fusion of two or more teeth or gemination of a single tooth. This report describes a unique case of double tooth in relation to a mandibular lateral incisor exhibiting the presence of four root canals. The role of conventional radiography and advanced three-dimensional imaging techniques in the better assessment of complex root canal systems and their aid in endodontic management has also been highlighted.

Detection of peri-implant bone defects using cone-beam computed tomography and digital periapical radiography with parallel and oblique projection

  • Saberi, Bardia Vadiati;Khosravifard, Negar;Ghandari, Farnaz;Hadinezhad, Arash
    • Imaging Science in Dentistry
    • /
    • 제49권4호
    • /
    • pp.265-272
    • /
    • 2019
  • Purpose: To compare the diagnostic accuracy of cone-beam computed tomography (CBCT) with that of parallel(PPA) and oblique projected periapical(OPA) radiography for the detection of different types of peri-implant bone defects. Materials and Methods: Forty implants inserted into bovine rib blocks were used. Thirty had standardized bone defects(10 each of angular, fenestration, and dehiscence defects), and 10 were defect-free controls. CBCT, PPA, and OPA images of the samples were acquired. The images were evaluated twice by each of 2 blinded observers regarding the presence or absence and the type of the defects. The area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were determined for each radiographic technique. The 3 modalities were compared using the Fisher exact and chi-square tests, with P<0.05 considered as statistical significance. Results: High inter-examiner reliability was observed for the 3 techniques. Angular defects were detected with high sensitivity and specificity by all 3 modalities. CBCT and OPA showed similar AUC and sensitivity in the detection of fenestration defects. In the identification of dehiscence defects, CBCT showed the highest sensitivity, followed by OPA and PPA, respectively. CBCT and OPA had a significantly greater ability than PPA to detect fenestration and dehiscence defects(P<0.05). Conclusion: The application of OPA radiography in addition to routine PPA imaging as a radiographic follow-up method for dental implantation greatly enhances the visualization of fenestration and dehiscence defects. CBCT properly depicted all defect types studied, but it involves a relatively high dose of radiation and cost.

Application of portable digital radiography for dental investigations of ancient Egyptian mummies during archaeological excavations: Evaluation and discussion of the advantages and limitations of different approaches and projections

  • Seiler, Roger;Eppenberger, Patrick;Ruhli, Frank
    • Imaging Science in Dentistry
    • /
    • 제48권3호
    • /
    • pp.167-176
    • /
    • 2018
  • Purpose: In the age of X-ray computed tomography (CT) and digital volume tomography (DVT), with their outstanding post-processing capabilities, indications for planar radiography for the study of the dentition of ancient Egyptian mummies may easily be overlooked. In this article, the advantages and limitations of different approaches and projections are discussed for planar oral and maxillofacial radiography using portable digital X-ray equipment during archaeological excavations. Furthermore, recommendations are provided regarding projections and sample positioning in this context. Materials and Methods: A total of 55 specimens, including 19 skeletonized mandibles, 14 skeletonized skulls, 18 separate mummified heads, and 4 partially preserved mummies were imaged using portable digital X-ray equipment in the course of archaeological excavations led by the University of Basel in the Valley of the Kings between 2009 and 2012. Images were evaluated by 2 authors with regard to the visibility of diagnostically relevant dental structures using a 4-point grading system(Likert scale). Results: Overall, the visibility of diagnostically relevant dental structures was rated highest by both authors on X-ray images acquired using a dental detector. The tube-shift technique in the lateral projections of mandibular dentition achieved the second-best rating, and lateral projections achieved the third-best rating. Conclusion: Conventional planar digital X-ray imaging, due to its ubiquity, remains an excellent method-and often the only practicable one-for examining the skulls and teeth of ancient Egyptian mummies under field conditions. Radiographic images of excellent diagnostic quality can be obtained, if an appropriate methodology regarding the selected projections and sample placement is followed.

Accuracy of digital periapical radiography and cone-beam computed tomography in detecting external root resorption

  • Creanga, Adriana Gabriela;Geha, Hassem;Sankar, Vidya;Teixeira, Fabricio B.;McMahan, Clyde Alex;Noujeim, Marcel
    • Imaging Science in Dentistry
    • /
    • 제45권3호
    • /
    • pp.153-158
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate and compare the efficacy of cone-beam computed tomography (CBCT) and digital intraoral radiography in diagnosing simulated small external root resorption cavities. Materials and Methods: Cavities were drilled in 159 roots using a small spherical bur at different root levels and on all surfaces. The teeth were imaged both with intraoral digital radiography using image plates and with CBCT. Two sets of intraoral images were acquired per tooth: orthogonal (PA) which was the conventional periapical radiograph and mesioangulated (SET). Four readers were asked to rate their confidence level in detecting and locating the lesions. Receiver operating characteristic (ROC) analysis was performed to assess the accuracy of each modality in detecting the presence of lesions, the affected surface, and the affected level. Analysis of variation was used to compare the results and kappa analysis was used to evaluate interobserver agreement. Results: A significant difference in the area under the ROC curves was found among the three modalities (P=0.0002), with CBCT (0.81) having a significantly higher value than PA (0.71) or SET (0.71). PA was slightly more accurate than SET, but the difference was not statistically significant. CBCT was also superior in locating the affected surface and level. Conclusion: CBCT has already proven its superiority in detecting multiple dental conditions, and this study shows it to likewise be superior in detecting and locating incipient external root resorption.

국내 치과방사선의 현황 및 이용 실태 (The Actual State and the Utilization for Dental Radiography in Korea)

  • 신귀순;김유현;이보람;김세영;이귀원;박창서;박혁;장계용
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권2호
    • /
    • pp.109-120
    • /
    • 2010
  • 치과 X선 검사 시 환자선량의 권고량 가이드라인을 개발하기 위해서 우선 국내 치과방사 선의 현황 및 이용 실태를 설문조사하여 비교분석하였다. 응답을 받은 77곳의 치과병 의원 중에서 치과대학이 있는 치과대학병원을 A그룹(11곳), 치과대학이 없는 대학병원을 포함한 치과병원을 B그룹(30곳), 치과의원을 C그룹(36곳)으로 분류하였다. 그룹별로 분석한 결과는 다음과 같았다. 치과병 의원 한 곳당 평균 unit chairs수는 A그룹 140.2개, B그룹 15.3개, C그룹 5.8개, 평균치과의사수는 A그룹 112.6명, B그룹 7.3명, C그룹 1.7명, 평균방사선사수는 A그룹 3.1명, B그룹 0.5명, C그룹에는 한 명도 없었고, 평균치과위생사수는 A그룹 19.7명, B그룹 12.5명, C그룹 3.3명이었다. 설치된 치과용 X선장치의 평균보유수는 A그룹 14.64대, B그룹 3.21대, C그룹 2.19대로 나타났다. 이 중에서 구내촬영장치가 가장 많았고, 다음은 파노라마 장치, 세팔로 장치, CBCT 장치 순이었으며, 장치시스템의 비율은 세 그룹 모두 DR 시스템이 50% 이상으로 가장 많았다. 필름 시스템인 경우, 사용된 구내필름은 감광도가 높은 Insight 필름(Kodak, USA)이 대부분이었으며, 자동 현상기는 사용하는 곳이 적었으나, 필름유지기구는 사용하는 곳이 약간 많았다. PACS 이용률은 A그룹 90.9%, B그룹 83.3%, C그룹 16.7%이었고, 프로그램은 국내의 Infinitt에서 개발된 PiView STAR가 가장 많이 이용되고 있었다. 치과병 의원 한 곳당 2008년도의 연간 평균촬영건수는 A그룹이 B그룹보다 6.8배, C그룹보다 21.2배 더 많았으며, 구내 치근단 촬영과 파노라마 촬영이 대부분이었다. 구내 치근단 촬영 시 관전압과 관전류는 세 그룹 모두 비슷하였으나, 노출시간은 C그룹이 A그룹의 12배, B 그룹의 3.5배 정도 길었다. 즉, 대부분 치과위생사가 촬영하고 있는 C그룹에서는 방사선 노출량이 다른 그룹에 비해 훨씬 많았다. 그러나 파노라마촬영 시의 조건은 세 그룹에서 큰 차이가 없었다. 결론적으로, 촬영조건은 경험적 지식을 따르기보다는 권장량을 사용해야 하며, 필름시스템에서는 자동현상기와 필름유지기구를 사용하여 방사선의 노출량을 줄여준다. 또한 환자선량의 감소와 X선 영상의 질 향상을위해서 X선발생장치 및 관련기기의 체계적인 정도관리가 반드시 필요하다.

Comparison of digital and conventional radiography for the detection of proximal surface caries

  • Park, Si-Seung;Cho, Young-Gon
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.592.1-592
    • /
    • 2001
  • Conventional intraoral radiography continues to be the most widely used for the diagnosis of dental caries. But conventional intraoral film has several shortcomings, including processing error, increased radiation dose, etc. Recently, various digital radiographs substitude for conventional radiography to overcome these disadvantages. The digital radiographies are numerous advantages, including elimination of processing errors, lower radiation dose, image quality enhancements such as contrast and density modulation.(omitted)

  • PDF

A new bite block for panoramic radiographs of anterior edentulous patients: A technical report

  • Park, Jong-Woong;Symkhampha, Khanthaly;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • 제45권2호
    • /
    • pp.117-122
    • /
    • 2015
  • Purpose: Panoramic radiographs taken using conventional chin-support devices have often presented problems with positioning accuracy and reproducibility. The aim of this report was to propose a new bite block for panoramic radiographs of anterior edentulous patients that better addresses these two issues. Materials and Methods: A new panoramic radiography bite block similar to the bite block for dentulous patients was developed to enable proper positioning stability for edentulous patients. The new bite block was designed and implemented in light of previous studies. The height of the new bite block was 18 mm and to compensate for the horizontal edentulous space, its horizontal width was 7 mm. The panoramic radiographs using the new bite block were compared with those using the conventional chin-support device. Results: Panoramic radiographs taken with the new bite block showed better stability and bilateral symmetry than those taken with the conventional chin-support device. Patients also showed less movement and more stable positioning during panoramic radiography with the new bite block. Conclusion: Conventional errors in panoramic radiographs of edentulous patients could be caused by unreliability of the chin-support device. The newly proposed bite block for panoramic radiographs of edentulous patients showed better reliability. Further study is required to evaluate the image quality and reproducibility of images with the new bite block.