• Title/Summary/Keyword: Dental Radiographic

Search Result 703, Processing Time 0.023 seconds

Maxillary ameloblastoma in an 8-year-old child: A case report with a review of the literature

  • Sheela, Sangeetharaj;Singer, Steven R.;Braidy, Hani F.;Alhatem, Albert;Creanga, Adriana G.
    • Imaging Science in Dentistry
    • /
    • v.49 no.3
    • /
    • pp.241-249
    • /
    • 2019
  • Ameloblastoma is a benign locally invasive tumor with a high tendency to recur. It is considered rare in the pediatric population, with most cases diagnosed in the third to fifth decades of life. Approximately 80% of ameloblastomas occur in the molar and ramus region of the mandible, while 20% of cases occur in the maxillary posterior region. This report presents a case of plexiform ameloblastoma in an uncommon location in an 8-year-old child. The lesion was initially thought to be a dentigerous cyst, based on its location and radiographic appearance. The clinical and radiographic features, histopathology, and treatment of solid, plexiform, maxillary ameloblastoma are reviewed, with an added emphasis on a literature review of ameloblastoma in children. This report emphasize the importance of long-term follow-up, since recurrence may occur many years after initial tumor removal.

COMPARATIVE STUDY ON THE MARGINAL BONE LOSS OF IMMEDIATE NONSUBMERGED AND SUBMERGED ENDOSSEOUS DENTAL IMPLANTS PLACED INTO EXTRACTION SOCKETS OF DOGS (발치후 즉시 매식한 Nonsubmerged와 Submerged 임플랜트의 변연골 흡수양상에 관한 비교연구)

  • Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.2
    • /
    • pp.255-264
    • /
    • 1997
  • The conventional osseointegration protocol calls for waiting up to 12 months for ossification of an extraction socket to heal before placing an endosseous implant. In this study, the possibility of placing a pure titanium implant directly into an extraction socket immediately after extraction was investigated. And the marginal bone loss of immediate nonsubmerged and submerged endosseous dental implants placed into extraction sockets was also compared. Pure titanium Nobelpharma Branemark implants and solid screw type ITI implants were placed into premolar extraction sockets of two adult dogs and allowed to heal for a period of 3 months, followed by functional loading of the implant. Radiographic examination was performed before implantation, immediately after implantation and 3, 6, 9, 12 months after implantation. The results obtained were as follows : 1. Immediately placed nonsubmerged ITI implants and submerged Branemark implants showed favorable radiographic osseointegration status and there were minimum marginal bone loss. 2. There were no significant differences in radiographic finding of osseointegration between conventional and immediate implantation. 3. Gingival tissue around implants showed more inflammatory signs than that of adjacent natural teeth. This study suggest that pure titanium Branemark implants and submerged ITI implants have the potential to integrate when placed immediatly after extraction of the teeth and warrants further investigation.

  • PDF

Effective dose of cone-beam computed tomography for orthodontic analysis in pediatric patient (소아환자에서 교정분석을 위한 콘빔CT 촬영시 유효선량에 관한 연구)

  • Kim, Eun-Kyung
    • The Journal of the Korean dental association
    • /
    • v.53 no.8
    • /
    • pp.558-568
    • /
    • 2015
  • Objective: The objectives of this study were to measure pediatric organ and effective doses of cone-beam computed tomography (CBCT) for orthodontic analysis and to compare them to those of panoramic and lateral cephalometric radiography, the conventional radiography for orthodontic analysis. Materials and Methods: Alphard VEGA for CBCT, Planmeca Proline XC for panoramic radiography and Orthophos CD for cephalometric radiography were used for this study. Thermoluminescent dosimeter (TLD) chips were located at 24 anatomic sites of 10-year-old anthropomorphic phantom and exposed during CBCT (C-mode; $200{\times}179mm$ FOV), panoramic and lateral cephalometric radiographic procedures at the clinical exposure settings for 10-year-old patient. Pediatric organ and effective doses were measured and calculated using ICRP 2007 tissue weighting factors. Results: Effective doses of CBCT, panoramic radiography and lateral cephlometric radiography in pediatric clinical exposure settings were $292.5{\mu}Sv$, $19.3{\mu}Sv$, and $4.4{\mu}Sv$ respectively. The thyroid gland contributed most significantly to the effective dose in all the radiographic procedures. Conclusion: Effective dose of CBCT was about 12 times to conventional radiographic procedures for orthodontic analysis in pediatric patient. The use of CBCT for orthodontic analysis should be fully justified over conventional radiography and dose optimization to decrease thyroid dose is needed in pediatric patients.

A RADIOGRAPHIC STUDY ON TEMPOROMANDIBULAR JOINT TROUBLE (악관절기능장애자의 방사선학적 연구)

  • Choe Byung Woon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.9 no.1
    • /
    • pp.13-18
    • /
    • 1979
  • The purpose of this study was to investigate the radiographic images of Temporomandibular joint trouble patients. This study included 186 patients with the chief complaints of TMJ pain and dysfunction. Their age ranged from 17 to 68 years. All patients were identified in the department of Dental mary of College of Dentistry, Seoul National University, Apr. 1978 to Jun. 1979. The author has observed the radiographic variations of two positions of condylar head taken by modified transcranial oblique-lateral projection, which are one in centric occlusion and the other in 1 inch(2.54㎝) mouth open. The results were obtained as follows; 1. In centric occlusion, the distances and positional relationship between the summit of condylar head and the deepest point of articular fossa revealed more or less large variations; Normal range is of 37.9%, anterior displacement of 37.3% and posterior displacement of 22.6%. 2. In the horizontal movement of condylar heads when on 1 inch mouth open, it was revealed that normalrange was of 46.5%, anterior displacement of 12.3%, posterior displacement of 41. 1 %. 3. In the positional interrelationship of both condylar heads when on 1 inch mouth open, it was revealed that symmetry(71. 5%) occurred approximately 2.5 times as many as asymmetry. 4. In both centric occlusion and 1 inch mouth open, it was showed that almost all estimated figures were greater in male than in female, and in the horizontal movement of condylar head when on 1 inch open, it was showed that hypermobility was dominant in male and hypomobility in female.

  • PDF

A Radiographic Study of Odontoma (치아종의 방사선학적 연구)

  • LEE Kyoung-Ho;CHOI Karp-Shik
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.145-153
    • /
    • 1998
  • The purpose of this study was to obtain information on the clinical and radiographic features of the odontomas in the jaws. For this study, the authors examined and analyzed the clinical records and radiographs of 119 patients who had lesion of odontoma diagnosed by clinical and radiographic examinations, The obtained results were as follows: 1. Odontoma occurred the most frequently in the 2nd decade(45.4%) and occurred more frequently III males (60.5%) than in females(39.5%). 2. The most common clinical symptom was the delayed eruption of the teeth(34.2%). 3. The type of lesions was mainly observed as compound odontoma(80.8%), and internal pattern of the complex odontoma was unevenly radiopaque(73.9%). 4. The compound odontoma frequently occurred in anterior portion of the maxilla(57.7%) and mandible(30,9%), and complex odontoma frequently occurred in anterior portion of maxilla(34.8%) and posterior portion of mandible(30.5%). 5. The effects on adjacent teeth were impaction of teeth(71.7%) and prolonged retention of deciduous teeth (31.7%), 6. The impaction of the teeth occurred in anterior portion of maxilla (44.2%) and mandible ( 19.2%), but root resorption of the adjacent teeth were not seen, 7. The boundary to adjacent structure was well-defined, the lesions appear as radiopaque mass with radiolucent rim.

  • PDF

ALVEOLAR BONE LOSS & BONE DENSITY CHANCES DURING THE FIRST YEAR A COMPARATIVE STUDY ON FOUR TYPES OF ROOT-FORM ENDOSSEOUS DENTAL IMPLANT SYSTEMS (치근형 골내 임플란트의 초기 1년간 치조골 소실 및 골 밀도 변화에 관한 연구)

  • Jung Young-Chul;Han Chong-Hyun;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.3
    • /
    • pp.455-469
    • /
    • 1994
  • Regular radiographic examination has been considered an essential diagnositic method for osseointegrated dental implantation. This study investigated marginal bone loss through the measurement on periapical radiographs and changes in bone density through digital subtraction image radiographic method around 88 endoseous root-form dental implants in 43 human subjects. Four types of endosseous dental implants were investigated : Standard series, Mini series and Hex-lock system of Steri-Oss Dental implant system, and $Br{\aa}nemark$-type implant from 3i dental implant system, in a 3 month interval for a total period of 12 months. The results were as follows : 1. Rapid bone loss occurred in the first 3 months in all 4 groups, and the bone level stabilized at the first thread of the implant fixtures. Amount of bone loss for 12 months showed correlation with the length of the polished neck portion. 2. Most of the implant systems showed resorption of alveolar bone up to the polished neck portion although a long polished neck could delay the resolution. 3. Alveolar bone loss apical to the polished neck portion stabilized at the first thread of the fixtures with no correlation to either the time of exposure of the polished neck or types of implant systems. 4. No changes in bone density around the implant threads were observed throughout the experimental period. Bone density decreased at the marginal bone, and increased at the newly-formed alveolar crest. These results indicate that most of the alveolar bone loss occur within the first 12 months after installation of endosseous root-form dental implants resulting in the exposure of polished neck portions, and the bone level stabilizes thereafter at the first thread portions of the implant fixtures. The experimental period of 12 months seems insufficient for observing changes in bone density, and a long-term observation should be needed.

  • PDF

Clinical and radiographic assessment of narrow-diameter and regular-diameter implants in the anterior and posterior jaw: 2 to 6 years of follow-up

  • Alrabiah, Mohammed;Deeb, Modhi Al;Alsahhaf, Abdulaziz;AlFawaz, Yasser F.;Al-Aali, Khulud Abdulrahman;Vohra, Fahim;Abduljabbar, Tariq
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.2
    • /
    • pp.97-105
    • /
    • 2020
  • Purpose: The present retrospective clinical study aimed to evaluate and compare the clinical and radiographic parameters, complications, and satisfaction in patients who received fixed prostheses supported by narrow-diameter implants (NDIs) in the anterior and posterior jaw. Methods: Patients aged ≥30 years who had NDI-supported fixed prostheses in the anterior or posterior region of either jaw for at least 2 years were included. Complications such as chipping of the crown; loosening or fracture of the screw, crown abutment, or implant; and loss of retention were recorded. Clinical peri-implant outcomes and crestal bone loss (CBL) were measured. A questionnaire was used to record responses regarding the aesthetics and function of the fixed restorations. Analysis of variance was used to assess the significance of between-group mean comparisons. The log-rank test was performed to analyze the influence of location and prosthesis type on technical complications. Results: Seventy-one patients (mean age: 39.6 years) provided informed consent with a mean follow-up duration of 53 months. Only bleeding on probing showed a statistically significant difference between NDIs in the anterior and posterior regions. The complication rate for NDIs in the posterior region was significantly higher than that for NDIs in the anterior region (P=0.041). For NDIs, CBL was significantly higher around splinted crowns than single crowns (P=0.022). Overall mean patient satisfaction was 10.34±3.65 on a visual analogue scale. Conclusions: NDIs in the anterior and posterior jaws functioned equally well in terms of periimplant soft and hard tissue health and offered acceptable patient satisfaction and reasonable complication rates.

Radiographic evaluation of the maxillary sinus prior to dental implant therapy: A comparison between two-dimensional and three-dimensional radiographic imaging

  • Tadinada, Aditya;Fung, Karen;Thacker, Sejal;Mahdian, Mina;Jadhav, Aniket;Schincaglia, Gian Pietro
    • Imaging Science in Dentistry
    • /
    • v.45 no.3
    • /
    • pp.169-174
    • /
    • 2015
  • Purpose: This study was performed to evaluate the diagnostic efficacy of panoramic radiography and cone-beam computed tomography (CBCT) in detecting sinus pathology. Materials and Methods: This study was based on a retrospective evaluation of patients who had undergone both a panoramic radiograph and a CBCT exam. A total of 100 maxillary sinuses were evaluated. Four examiners with various levels of expertise evaluated the images using a five-point scoring system. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic efficacy of the two modalities. The image analysis was repeated twice, with at least two weeks between the evaluation sessions. Interobserver reliability was assessed using Cronbach's alpha, and intraobserver reliability was assessed using Cohen's kappa. Results: Maxillary sinus pathology was detected in 72% of the patients. High interobserver and intraobserver reliability were observed for both imaging modalities and among the four examiners. Statistical analyses using ROC curves demonstrated that the CBCT images had a larger area under the curve (0.940) than the panoramic radiographs (0.579). Conclusion: Three-dimensional evaluation of the sinus with CBCT was significantly more reliable in detecting pathology than panoramic imaging.

The reliability of tablet computers in depicting maxillofacial radiographic landmarks

  • Tadinada, Aditya;Mahdian, Mina;Sheth, Sonam;Chandhoke, Taranpreet K;Gopalakrishna, Aadarsh;Potluri, Anitha;Yadav, Sumit
    • Imaging Science in Dentistry
    • /
    • v.45 no.3
    • /
    • pp.175-180
    • /
    • 2015
  • Purpose: This study was performed to evaluate the reliability of the identification of anatomical landmarks in panoramic and lateral cephalometric radiographs on a standard medical grade picture archiving communication system (PACS) monitor and a tablet computer (iPad 5). Materials and Methods: A total of 1000 radiographs, including 500 panoramic and 500 lateral cephalometric radiographs, were retrieved from the de-identified dataset of the archive of the Section of Oral and Maxillofacial Radiology of the University Of Connecticut School Of Dental Medicine. Major radiographic anatomical landmarks were independently reviewed by two examiners on both displays. The examiners initially reviewed ten panoramic and ten lateral cephalometric radiographs using each imaging system, in order to verify interoperator agreement in landmark identification. The images were scored on a four-point scale reflecting the diagnostic image quality and exposure level of the images. Results: Statistical analysis showed no significant difference between the two displays regarding the visibility and clarity of the landmarks in either the panoramic or cephalometric radiographs. Conclusion: Tablet computers can reliably show anatomical landmarks in panoramic and lateral cephalometric radiographs.

Perceptions and attitudes of dental hygienists toward radiation safety and protection in the Republic of Korea

  • Yun, Kwidug;Lee, Kyung-Min;An, Seo-Young;Yoon, Suk-Ja;Jeong, Ho-Gul;Lee, Jae-Seo
    • International Journal of Oral Biology
    • /
    • v.46 no.4
    • /
    • pp.168-175
    • /
    • 2021
  • To investigate the perceptions and attitudes of dental hygienists toward radiation safety management in Korea. A total of 800 dental hygienists were randomly selected for an anonymous survey, and 203 of them participated. The questionnaire items included the following: sex, career period, type of installed radiographic equipment, recognition of the diagnostic reference level (DRL), participation in radiation safety education, and attitudes toward radiation protection for both patients and dental hygienists. The participants were divided into two groups according to their years of experience (< 10 years versus ≥ 10 years). The difference between the groups was investigated according to frequency distribution. Fisher's exact test or Pearson's chi-square (𝛘2) test was used as appropriate. A regression analysis was performed to investigate the impact of wearing a thyroid collar for personnel protection during patient radiation exposure. The types of installed radiographic equipment included panoramic radiography (96.1%), cephalometric radiography (76.9%), intraoral radiography (72.9%), and cone-beam computed tomography (69.5%). Significant differences were observed in the learning pathway for the DRL (Fisher's exact test, p < 0.05), satisfaction with radiation safety education (Pearson's 𝛘2 test = 5.3975, Pr = 0.02), and use of personnel radiation monitoring systems (Pearson's 𝛘2 test = 18.1233, Pr = 0.000) between the groups. Significant differences were also observed in personnel protection using a thyroid collar and patient protection during panoramic radiography (odds ratio = 14.2). Dental hygienists with more than 10 years of experience were more satisfied with radiation safety education and more interested in radiation monitoring. Considering career experience, customized, continuous, and effective radiation safety management education should be provided.