• Title/Summary/Keyword: Dental Procedures

Search Result 737, Processing Time 0.024 seconds

THE COMPARATIVE EVALUATION USING HATCH REAMER TECHNIQUE AND OSTEOTOME TECHNIQUE IN SINUS FLOOR ELEVATION (상악동저 거상술 시 Osteotome 술식과 Hatch Reamer 술식의 비교평가)

  • Cho, Seong-Woong;Kim, Sang-Jung;Lee, Dong-Keun;Kim, Chin-Soo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.2
    • /
    • pp.154-161
    • /
    • 2010
  • Many edentulous posterior maxilla are found to be compromised by alveolar resorption and increased pneumatization of the sinus. One of the surgical procedures to overcome this anatomical limitation is sinus floor elevation with bone graft, which is reported as more appropriate and more successful procedure. Commonly, if the residual bone height is over 5mm, sinus floor elevation is operated through transcrestal approach using osteotome technique. But, it is possible for patients to feel discomfort during operation and dizziness after operation while malleting, sinus floor elevation, using osteotome technique. Some instruments and methods has been used to overcome these problems and use more easily. The aim of this study is to compare between the surgical procedure of sinus floor elevation using Hatch reamer technique and that of sinus floor elevation using osteotome technique. From 2004 Feb to 2007 Oct, we investigate patients (osteotome group: 72, Hatch reamer group: 70) who were given implant surgery with sinus floor elevation (osteotome group: 92, Hatch reamer group: 98). We analysed gender, age, residual bone height, amount of sinus floor elevation, used graft material, total success rate, failure rate by residual bone height and implant type and discomfort during operation, etc. The results obtained were as follows. 1. In the amount of sinus elevation was osteotome group was $3.85{\pm}1.02\;mm$ and Hatch reamer group was $3.93{\pm}1.38\;mm$. There was no statistically significant difference between the two groups (P > 0.05). 2. At the total success rate, osteotome group was 92.4% and Hatch reamer group was 94.9%. There was no statistically significant difference between the two groups (P > 0.05). 3. On the discomfort during the operation by using numerical rating scale, osteotome group was $2.87{\pm}0.83$ and Hatch reamer group was $1.12{\pm}0.64$. There was statistically significant difference between the two groups (P < 0.05). The Hatch reamer group clinical results was similar to osteotome group and we thought that Hatch reamer technique can overcome the faults of osteotome technique.

Chairside computer-aided design/computer-aided manufacturing (CAD/CAM)-based restoration of anterior teeth with customized shade and surface characterization: a report of 2 cases (CAD/CAM을 이용한 전치부 수복시 색조 및 표면 특성의 개별화를 시행한 증례)

  • Kim, Hyun-Jung;Jang, Ji-Hyun;Ryu, Gil-Joo;Choi, Kyoung-Kyu;Kim, Duck-Su
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.128-137
    • /
    • 2020
  • Over the last 30 years, the use of chairside computer-aided design (CAD) and computer-aided manufacturing (CAM) systems has evolved and has become increasingly popular in dentistry. Although CAD/CAM restorations have been used in the anterior dentition, satisfying the esthetic requirements of clinicians and patients, where the restorations are limited to the chairside, remains a challenge. To reproduce multi-shades of CAD/CAM restorations in the clinic, a preliminary experiment to express several shades on A2 lithium disilicate (LS2) blocks using a staining kit was performed. After measurement of the CIE L*a*b* value of specimens, it was compared with that of the commercial shade guide. This report presents two cases with individual customization of shade and surface characterization of the CAD/CAM restorations using predictable methods based on the preliminary experimental data. The anatomical shape of restoration was obtained from 'copy and paste technique' and 'mirror image acquisition technique'. All treatment procedures and fabrication of restorations performed in this report were executed in the clinic itself.

Evaluation of the course of the inferior alveolar canal in the mandibular ramus using cone beam computed tomography

  • Kwon, Kyung-Hwan;Sim, Kyu-Bong;Lee, Jae-Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.4
    • /
    • pp.231-239
    • /
    • 2012
  • Objectives: This study sought to provide guidelines in order to decrease the incidence of nerve injury during mandibular ramus bone harvesting, and to improve understanding of the anatomical structure of the inferior alveolar canal (IAC) to include its distance from the exterior buccal cortex. Materials and Methods: In January and February 2009, 20 patients who visited the Wonkwang University Department of Oral and Maxillofacial Surgery reporting various conditions underwent cone beam computed tomography and were included in this study. Patients with missing left or right mandibular first molars or incisors, or who had jaw fracture or bone pathologies, were excluded. The reference point (R point) was defined as the point where the occlusal plane reached the anterior ramus of the mandible. The position of the IAC in relation to the R point, the buccal bone width (BW), the alveolar crest distance (ACD), the distance from the alveolar crest to the occlusal plane (COD), and the distance from the IAC to the sagittal plane (CS) were determined using proprietary image analysis software which produced cross-sectional coronal and axial images. Results: The distance medially from the R point to the IAC along the axial plane was $6.19{\pm}1.21mm$. The HD from the R point, posteriorly to IAC, in the lateral view was $13.07{\pm}2.45mm$, the VD from the R point was $14.24{\pm}2.41mm$, and the ND from the R point was $10.12{\pm}1.76mm$. The pathway of the IAC was positioned almost in a straight line along a sagittal plane within $0.56{\pm}0.70mm$. The distance from the buccal bone surface to the IAC increased anteriorly from the R point. Conclusion: Marking osteotomy lines in the retromolar area in procedures involving bone harvesting should be discouraged due to the risk of damage to IAC structures. Our measurements indicated that the area from the R point in the ramus of the mandible to 10 mm anterior can be safely harvested for bone grafting purposes.

AUTOTRANSPLANTATION OF IMPACTED MAXILLARY CANINES (매복된 상악 견치의 자가치아이식을 통한 치험례)

  • Kim, Tae-Wan;Kim, Hyun-Jung;Kim, Young-Jin;Nam, Soon-Hyeun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.326-333
    • /
    • 2003
  • The appropriate treatment for eruption guide of impacted teeth necessitates the formulation of a comprehensive treatment plan, which is dependent upon a number of factors such as the condition of the deciduous teeth, dental and skeletal relationship, dental age of the patient, willingness of the patient to undergo extensive dental treatment and financial considerations. If the etiology of the eruption disturbance has been identified, the elimination of the causes and various procedures can be used for eruption guide. Particularly the transplantation is a valuable alternative to extraction of impacted teeth, where surgical exposure and subsequent orthodontic realignment are difficult or impossible. This report present three cases of autotransplantation of impacted maxillary canine. As the result in these cases, atraumatic removal of donor tooth during operation is prerequisite to an optimal clinical result. Due to a high possibility of pulp necrosis, endodontic treatment of fully developed transplanted teeth should be undertaken. In complex case, autotransplantation can save time and less expensive than orthodontic forced eruption. Recipient socket should be prepared to a size that is slightly larger than the root of the donor tooth, and can be prepared with open or close procedure depends on root size of donor tooth and buccolingual width at transplantion site.

  • PDF

The Evaluation of the atomic composition and the surface roughness of Titanium Implants following Various Laser treatment with air-powder abrasive (레이저 처리후 임프란트 표면 변화에 관한 연구)

  • Kim, Tae-Jung;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.615-630
    • /
    • 2002
  • Various long-term studies have shown that titanium implants as abutments for different types of prostheses have become a predictable adjunct in the treatment of partially or fully edentulous patients. The continuous exposure of dental implants to the oral cavity with all its possible contaminants creates a problem. A lack of attachment, together with or caused by bacterial insult, may lead to peri-implantitis and eventual implant failure. Removal of plaque and calculus deposits from dental titanium implants with procedures and instruments originally made for cleaning natural teeth or roots may cause major alterations of the delicate titanium oxide layer. Therefore, the ultimate goal of a cleaning procedure should be to remove the contaminants and restore the elemental composition of the surface oxide without changing the surface topography and harming the surrounding tissues. Among many chemical and mechanical procedure, air-powder abrasive have been known to be most effective for cleaning and detoxification of implant surface. Most of published studies show that the dental laser may be useful in the treatment of pen-implantitis. $CO_2$ laser and Soft Diode laser were reported to kill bacteria of implant surface. The purpose of this study was to obtain clinical guide by application these laser to implant surface by means of Non-contact Surface profilometer and X-ray photoelectron spectroscopy(XPS) with respect to surface roughness and atomic composition. Experimental rough pure titanium cylinder models were fabricated. All of them was air-powder abraded for 1 minute and they were named control group. And then, the $CO_2$ laser treatment under dry, hydrogen peroxide and wet condition or the Soft Diode laser treatment under Toluidine blue O solution condition was performed on the each of the control models. The results were as follows: 1. Mean Surface roughness(Ra) of all experimental group was decreased than that of control group. But it wasn't statistically significant. 2. XPS analysis showed that in the all experimental group, titanium level were decreased, when compared with control group. 3. XPS analysis showed that the level of oxygen in the experimental group 1, 3($CO_2$ laser treatment under dry and wet condition) and 4(Soft Diode laser was used under toluidine blue O solution) were decreased, when compared with control group. 4. XPS analysis showed that the atomic composition of experimental group 2($CO_2$ laser treatment under hydrogen peroxide) was to be closest to that of control group than the other experimental group. From the result of this study, this may be concluded. Following air-powder abrasive treatment, the $CO_2$ laser in safe d-pulse mode and the Soft Diode laser used with photosensitizer would not change rough titanium surface roughness. Especially, $CO_2$ laser treatment under hydrogen peroxide gave the best results from elemental points of view, and can be used safely to treat peri-implantitis.

The evaluation of healing patterns in surgically created circumferential gap defects around dental implants according to implant surface, defect width and defect morphology

  • Im, Se-Ung;Hong, Ji-Youn;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Lee, Yong-Keun;Cho, Kyoo-Sung;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.sup2
    • /
    • pp.385-394
    • /
    • 2008
  • Purpose: The aim of this study was to evaluate the factors affecting healing patterns of surgically created circumferential gap defects around implants in dogs. Materials and Methods: In four mongrel dogs, all mandibular premolars were extracted. After 8 weeks of healing periods, implants were submerged. According to the surface treatment, turned surface was designated as a group A and rough surface as a group B. In each dog, surgical defects on the left side were made with a customized tapered step drill and on the right with a customized paralleled drill. Groups were also divided according to the width of the coronal gaps: 1.0mm, 1.5mm, or 2.0mm. The dogs were sacrificed following 8 weeks and the specimens were analyzed histologically and histomorphometrically. Results: During the postoperative period, healing was uneventful and implants were well-maintained. As the size of the coronal gap was increased, the amount of bone-to-implant contact was decreased. The bone healing was greater in rough surface implants compared to the turned ones. About the defect morphology, tapered shape showed much bone healing and direct bone to implant contact even in the smooth surface implants. Conclusion: Healing of the circumferential defect around dental implant is influenced by the implant surface, defect width and the morphology of the defect. When using rough surface implants, circumferential gap defects within 2 mm do not need any kinds of regenerative procedures and the healing appeared to be faster in the tapered defect morphology than the paralleled one.

A COMPARATIVE STUDY OF CHLORAL HYDRATE/HYDROXYZINE VERSUS MIDAZOLAM/MEPERIDINE AS ORAL CONSCIOUS SEDATIVE REGIMENS (Chloral hydrate/Hydroxyzine과 Midazolam/Meperidine의 경구 투여 진정효과에 관한 비교 연구)

  • Kim, Yong-Heon;Kim, Ji-Yeon;Park, Ki-Tae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.2
    • /
    • pp.262-269
    • /
    • 2005
  • The purpose of this study was to compare the efficacy and complications of two oral sedative regimens, chloral hydrate (60mg/kg)/hydroxyzine(25mg) versus midazolam(1mg/kg)/meperidine(1mg/kg) for the sedation of pediatric dental patients. Fifteen patients(mean age 36.2months, range 24-47months), ASA Class I or II, who needed at least two restorative dental procedures were selected in this double-blind, randomized study. All subjects were randomly assigned to receive either chloral hydrate/hydroxyzine or midazolam/meperidine and 50% $N_2O/O_2$ was administered at each appointment. Behavior assessment(sleep, movement, crying, overall behavior) was made using Houpt Sedation Rating Scale and physiologic parameters(pulse rate, oxygen saturation) were monitored using pulse oximeter. The incidence of hypoxia($SpO_2$ 90% or less, at least 10s duration) and vomiting was recorded. Patients sedated with chloral hydrate/hydroxyzine showed significantly better overall behavior score than patients sedated with midazolam/meperidine. There was no clinically significant difference in the incidence of hypoxia and vomiting. It was concluded that oral administration of chloral hydrate/hydroxyzine is more effective than midazolam/meperidine for the sedation of pediatric dental patients.

  • PDF

Esthetic Root Coverage for Gingival Recession (심미적인 결과를 얻기 위한 치근 피개술)

  • Ahn, MyungHwan
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.26 no.1
    • /
    • pp.4-16
    • /
    • 2017
  • In dental esthetics, soft tissue plays an important part, probably very large portion of it. A clear understanding of the periodontal tissues and its management around teeth and implants help us to develop concepts for a modern dental treatment that addresses the needs of demanding patients in regard of esthetics and durability. When we talk about esthetic, we can say that one of the most important element is a harmonization with gingiva (soft tissue) called 'Pink Esthetic' As for the pink esthetics, gingival line(contour) takes most of the influence on esthetic result; it consists of labial gingival level, interproximal papilla height, and a line that connects them. In the gingival recession, labial gingival level and gingival contour move to the apical portion, and the root area is exposed. It leads to the unesthetic result. Root coverage technique is classically used to treat gingival recession (marginal tissue recession) of natural teeth. It is an essential technique on periodontal plastic surgery part. It is also a very useful technique to recover soft tissue problems in implant dentistry. So, root coverage technique must be mastered for a good implant esthetic result. The general overview of root coverage procedures will be discussed with step by step explanation to get more esthetic result.

The Bleaching Effect of Plasma Are and 35% Carbamaide Peroxide and its Influence on the Enamel Surface (Plasma Arc와 35% Carbamaide Peroxide의 미백효과와 법랑질 표면에 미치는 영향)

  • Gu, Hyo-Jin;Song, Keun-Bae
    • Journal of dental hygiene science
    • /
    • v.9 no.5
    • /
    • pp.525-530
    • /
    • 2009
  • The purpose of this study was to evaluate color change and enamel surface changes using the plasma arc light source during tooth bleaching treatments. Twenty-four extracted bovine incisors were selected and embedded in the resin blocks. All the specimens were highly polished and discolored with commercial $COCK^{(R)}$. High concentration carbamide peroxide with and without plasma arc were used for bleaching. Specimens were bleached for 1 hour per week during 3 weeks. Color and enamel surface changes were determined with colorimeter (TC-8600A), microhardness tester(MXT-a7), scanning electron microscope(S-4200). All the collected data analyzed with paired t-test, t-test and one-way ANOVA. After the bleaching, both groups showed the color changes(${\Delta}E^*$). Microhardness of two group decreased after tooth bleaching. The SEM evaluation of enamel surface of both group showed a similar morphology of decalcification after tooth bleaching. Office bleaching using the plasma arc application with 35% carbamide peroxide can increase the color change. Office bleaching using the high concentration of carbamide peroxide and plasma arc also detract the outer surface of enamel. It is recommended that careful procedures are needed during office bleaching with high concentration of carbamide peroxide and light source.

  • PDF

Effectiveness Evaluation of Displacement Accommodatable Pressure Measuring Jig for Quality Assessment of Pressure Application Device (압력 인가 장치의 품질관리를 위한 변위 수용이 가능한 압력 측정용 지그의 유효성 평가)

  • Mun, Chang-Su;Jun, Sung-Chul;Noh, Si-Cheol
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.2
    • /
    • pp.61-66
    • /
    • 2020
  • Recently, a variety of electric anesthetics devices have been developed and used in clinical practice to reduce the fatigue of the operator during local anesthesia for dental procedures and to compensate for the disadvantages of manual anesthesia device. In this electric anesthesia injection device, the accurate and constant delivery of pressure for drug infusion is a very important performance factor. In order to evaluate the accuracy of the transfer pressure, a small pressure gauge using a load cell is often used, but since the elastic body inside the load cell may not be able to accommodate a sufficient displacement, an error may occur when evaluating pressure performance. For these reasons, in this study, we proposed and evaluated a silicon-chrome steel (Si-Cr steel) spring jig that can accommodate relatively large displacements that can be used when evaluating the performance of a pressure-controlled pressure application device using a load cell type pressure gauge. As a result of the pressure transmissibility test and repeated measurement results using a commercial dental anesthesia injection device, a more stable result was obtained when using a spring jig, and it was confirmed that the frequency of abnormally high measurement was reduced.