• 제목/요약/키워드: Dental Laboratory Technology

검색결과 686건 처리시간 0.021초

치과기공사의 피부질환 요인 - 서울시 중심 - (Factors of Skin Diseases in Dental Technician (Focus in Seoul))

  • 안재석;김해준;오세윤;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제29권1호
    • /
    • pp.9-21
    • /
    • 2007
  • This study was conducted to determine the cause and prevalence of occupational skin disease in dental technicians working in Seoul, Korea. and to investigate the relation between these work condition and skin disease of the hand, wrist and forearm. This study was based on the Nordic occupational skin questionnaire(NOSQ), a self-administrated questionnaire which was modified to investigate the dental technician's occupational factors in domestic circumstances. The number was distributed to 500 dental technicians who participated in annual continuing education for dental technicians of the Seoul metropolitan area in April 2006. Of the subjects, 62(30.4%) had eczema and 70(32.9%) had urticaria, as diagnosed. Of the subjects with the symptoms of urticaria, 30 complained of atopic dermatitis, 65 complained of allergic rhinitis, 56 complained of allergic conjunctivitis, and 18 complained of asthma. The group with atopic history had a higher frequency of eczema or urticaria than the group without atopic history. From multiple regression analysis, the group who had a history of atopic dermatitis also had high symptom rates of eczema. The group who had a history of allergic rhinitis and allergic conjunctivitis had high symptom rates of urticaria. The urticaria symptom rates were higher in those wearing gloves than those who did not for the type of work.

  • PDF

IV형 경석고와 경화처리된 IV형 경석고 그리고 폴리우레탄 수지 치형재의 표면경도와 미세구조 특성의 비교 (A comparison of surface hardness and microstructural characteristics between a type IV stone with and without die hardening treatment, and a polyurethane resin die material)

  • 이완선;김지환;김태석;김남식;유진호
    • 대한치과기공학회지
    • /
    • 제34권3호
    • /
    • pp.227-235
    • /
    • 2012
  • Purpose: This study compared the surface hardness (Vickers) and microstructural characteristics between a type IV stone with and without die hardening treatment, a polyurethane die material. Methods: Materials used were a type IV stone(MG Crystal Rock), two die hardeners (Hardening bath, Epox-it), and a polyurethane resin material(Polyluck). Six specimens per group were prepared according to manufacturer's directions. The prepared specimens were tested by means of hardness test, one-way ANOVA analysis, scanning electron microscopic(SEM) observations and energy dispersive spectroscopic(EDS) analysis. Results: In the hardness test and its statistical analysis, there was no significant difference in the surface hardness between a type IV stone and type IV stone with die hardener coating, type IV stone mixed with an epoxy like material instead of water. In contrast, polyurethane resin material exhibited significantly greater surface hardness than other specimen groups (p<0.05). Conclusion: By considering the results of the hardness test, SEM observations and EDS analysis, although the die hardeners on type IV stone did not show remarkable improvement in surface hardness, the die hardener coating on the surface of type IV stone material did show decrease of microporous and improvement of surface defects.

치과용 Ni-Cr 합금의 조성에 따른 세라믹의 색차 분석 (Ceramic color differences of dental Ni-Cr alloy by compositional change)

  • 김사임;김태연;김세하;강정규;이정환
    • 대한치과기공학회지
    • /
    • 제43권4호
    • /
    • pp.168-174
    • /
    • 2021
  • Purpose: This study was conducted to investigate alloys spectrophotometrically including yttrium of nickel-chromium (Ni-Cr) alloys, which are used as substitutes for the regulation of beryllium and provide helpful improvements in Ni-Cr alloys. Methods: Four groups of specimens (ZN, ZY, SN and EM) were prepared for analysis. Color parameters were measured with a spectrophotometer, and color difference (∆E*) was calculated. The t-test and one-way analysis of variance test were used to determine significant difference, and the Tukey test was used to identify where the differences were. To measure the spectroscopic reflectivity, the spectroscopic reflectance was measured and converted into CIE L*, a*, b* color system. Results: The ∆E* value of each metal ceramic group after opaque firing of Ni-Cr alloy with and without yttrium was <2, and the total group color difference (∆E*) was below 1 in the dentin ceramic all experimental group. However, the a* and b* values of the metal ceramic groups were higher than that in the lithium disilicate all ceramic group, and the chroma was higher than the natural tooth. The brightness of all experimental groups was similar to that of the shade guide sample. Conclusion: Yttrium added to Ni-Cr alloys showed similar CIE L*, a*, b* values to Ni-Cr alloys that did not contain yttrium, indicating that yttrium had no effect on color in metallic ceramic systems.

‘치과기공사’명칭변경에 관한 부산지역 치과기공사들의 의견 연구 (A Study on the recognition of dental lab technicians in Busan about the retitle of ‘Dental Technician’)

  • 김부섭;정인성
    • 대한치과기공학회지
    • /
    • 제26권1호
    • /
    • pp.59-67
    • /
    • 2004
  • The purpose of this study was to research the recognition of Korean Dental Technicians in Busan region about retitle of the name of 'Dental Technician'(DT), then to figure out the reality of retitle of the name(DT), so to provide data for whole country survey and to drive of the retitle of DT by Korea Dental Technicians Association. For these purpose, 250 subjects were sampled out of dental technicians in Busan, and the survey was performed with self-administered questionnaire. Out of all collected questionnaires, 192 pieces(76.8%) were addressed for this study. 1) Their desires on changing of the name(DT), 57.4%(74/129) was agreed. 2) If they could change the name(DT), they hope 3 main new names and the others, Dental Lab Art Technician(39.2%), Certified Dental Technician(23.0%), Dental Prosthetic Technician(23.0%), the others(14.8%).

  • PDF

우리나라 호흡기계질환의 역학조사에 사용되는 설문지의 신뢰도 분석 연구 - 일부 치과기공사를 대상으로 - (A Study on Analysis of Reliability to Korean version Questionaries on Respiratory Symptoms in Korea - For the responese to dental technician Laboratory -)

  • 고재춘
    • 대한치과기공학회지
    • /
    • 제17권1호
    • /
    • pp.72-81
    • /
    • 1995
  • The study was performed to compare the raliablity of two Korean version questionaires for respiratory symptoms and ilness being used in Korea. The subjects were 103 dental laboratory technician who divided into two groups as SUN-81-AL and SUN-93. The duration of test-retest was one two month. The differences between two groups interms of average age, height, and weight were negligible. The SUN-93 showed higher agreement compared to SUN-81-AL except items cough and smoking. The Sun-93 deserved to prefer to be used in resporatory epidemiologic study.

  • PDF

치과기공사 실기시험 개선에 관한 조사 연구 I (The Study on the improvement of dental technician practical examination I)

  • 배은정;김웅철;정인성;남상용;김지환
    • 대한치과기공학회지
    • /
    • 제34권4호
    • /
    • pp.413-421
    • /
    • 2012
  • Purpose: The purpose of this study is to investigate the improvement measure of dental technician practical examination. Methods: A survey was performed on 111 dental technicians who were self-written questionnaire. The results were analyzed by SPSS 12.0. The collected data was analyzed by frequency and chi-square test. Results: Questions most necessary work tools with the articulator was the highest with 55.9%, Electric wax carver(16.2%), heating clear(14.4%), CAD/CAM program(9.0%) was in the order. The need for additional practical test in response to actions included maxillary and mandibular comments occlusal work that you have to wax up the highest rate of 63.8%. Items most in need of improvement was strengthen of clinically oriented(48.0%), separation of written and practical(14.6%), control the degree of difficulty(11.4%) were the next order. Conclusion: Based on the results of this study, the current dental technician did not show major problems in the practical test. However, clinicians should be strengthened mainly. To do this, the use of the articulator is essential.

치과용 DLP 3D Printer 가공체의 주조성 관찰 (Observation of Castability of Dental DLP 3D Printer Materials)

  • 송준부;박유진;최성민
    • 대한치과기공학회지
    • /
    • 제41권4호
    • /
    • pp.255-262
    • /
    • 2019
  • Purpose: Recently, the production technology of dental prosthesis using 3D Printer workpeices has been developed. However, the lack of information on the work processes and casting techniques of materials for 3D printing casting is expected to require research. Therefore, in this study, we intend to cast a Dental DLP 3D Printer workpiece, which is being commercialized, to identify its appearance and internal clearance, and to observe its castability. Methods: Castability of the 3D Printer workpiece was evaluated. The specimen is prepared in a cylindrical shape and in a 1 mm thick coping shape. The control specimen is made of wax and the experimental specimen is made of resin using two types of 3D printers. After casting, the appearance of the casting body was observed and the internal clearance of the coping was measured. Results: RP1 and RP2, cylindrical specimens, were partially cast or fin. When coping-type specimens were measured before casting, the internal clearance of PE2 was more accurate than that of PC and PE1. When coping-type specimens were measured after casting, CE1 was the most accurate in occlusal clearance and CE2n was the most accurate in axial clearance. Conclusion: 1. Exterior observations of the casting body indicated casting defects and fins. 2. Internal clearance observations show that the occlusal clearance of the castings is larger after casting, and the axial clearance of the castings is smaller after casting. 3. It is judged that the RP2 specimen is more likely to be applied for casting than the RP1 specimen.

치과용 바렐연마기의 연마시간에 따른 Co-Cr 합금의 표면거칠기 관찰 (Observations of surface roughness of Co-Cr alloys according to grinding time of dental barrel finishing)

  • 고현정;박유진;최성민
    • 대한치과기공학회지
    • /
    • 제43권3호
    • /
    • pp.93-98
    • /
    • 2021
  • Purpose: The aim of this study was to observe the surface roughness and surface topography of cobalt-chrome (Co-Cr) alloys with grinding time in dental barrel finishing. Methods: This study involved two types of Co-Cr alloys. Specimens were manufactured with the dimensions 10×10×2 mm. Each specimen was cast according to the manufacturer's instructions. The cast alloys were polished for 35 minutes at intervals of five minutes in an automatic barrel finishing. Specimens were imaged with a three-dimensional optical microscope to measure surface roughness. Results: BC specimens and GM specimens had the highest roughness (Ra) values in the ungrained control group, and the lowest Ra values were measured 20 minutes after grinding. Conclusion: The best conditions for grinding Co-Cr alloy using a dental barrel finishing were a weight ratio of polishing media, water, and compound of 150 g:200 g:5 g, and a rotation speed of 450 rpm. Grinding time to obtain appropriate surface roughness should be limited to 15 to 30 minutes.

순수 티타늄 주조체의 주형온도에 따른 용탕반응성 및 표면거칠기 (Metal-Mold Reaction and Surface Roughness Measurement of Pure Titanium Casting Specimens with Mold Temperatures)

  • 차성수;송영주;박수철
    • 대한치과기공학회지
    • /
    • 제32권4호
    • /
    • pp.297-305
    • /
    • 2010
  • Purpose: The purpose of this study was to observe the change of metal-mold reaction and surface roughness in titanium casting specimens for phosphate-silica alumina bonded investment with mold temperatures. Methods: The metal-phosphate silica alumina bonded mold interface reaction and surface roughness of titanium casting specimens according to mold temperatures were investigated. The Specimens were analysed by scanning electron microscopy and surface roughness tester. Results: The oxidation behavior indicated by the growth of oxide thickness. The titanium-oxide layer were consisted two layer of a porous external and a dense internal one. The reaction layer and surface roughness increased with increasing investment material temperature. Conclusion: In this work, The most suitable mold temperature in casting of pure titanium was $200^{\circ}C$.

치과 3D 프린팅용 자외선 경화 레진에 광원의 두 가지 파장에 따른 경화 및 항온수조 침적에 따른 변형률의 비교 분석 (Comparative analysis of strain according to two wavelengths of light source and constant temperature bath deposition in ultraviolet-curing resin for dental three-dimensional printing)

  • 김동연;이광영;강후원;양천승
    • 대한치과기공학회지
    • /
    • 제42권3호
    • /
    • pp.208-212
    • /
    • 2020
  • Purpose: This study aimed to analyze the shrinkage and expansion strain of ultraviolet (UV)-cured resin according to the wavelength of the light source and compare the shrinkage and expansion. Methods: We prepared the mold with according to the ISO 4049 specimen. The size of the circle in the mold was prepared with a height of 6.02 mm and a diameter of 4 mm. UV-curable resin for three-dimensional (3D) printing was injected into the circular mold. The control group was irradiated with a wavelength of 400~405 nm using UV-curing equipment (400 group), and the experimental group was irradiated with a wavelength of 460~465 nm (460 group). Both groups were produced ten specimens. The produced specimen was first measured with a digital micrometer. After the first measurement, the specimen was immersed in a constant temperature water bath for 15 days, after which the second measurement was performed, and the third measurement was taken after 30 days. The measured values were analyzed using the independent sample t-test (α=0.05). Results: In the non-immersion water tank, the contraction was 0.9% in the 400 group and 1.3% in the 460 group. In the constant temperature bath, the expansion was high at -0.4% in the 400 group for 15 days, and the smallest expansion was -0.03% for the 400 group for 30 days. There were significant differences between the two groups (p<0.05). Conclusion: The 400 group had a lower UV resin specimen strain than the 460 group. Therefore, it is recommended to use the wavelength required by the UV-curing resin.