DOI QR코드

DOI QR Code

Comparative analysis of strain according to two wavelengths of light source and constant temperature bath deposition in ultraviolet-curing resin for dental three-dimensional printing

치과 3D 프린팅용 자외선 경화 레진에 광원의 두 가지 파장에 따른 경화 및 항온수조 침적에 따른 변형률의 비교 분석

  • Received : 2020.07.20
  • Accepted : 2020.08.27
  • Published : 2020.09.30

Abstract

Purpose: This study aimed to analyze the shrinkage and expansion strain of ultraviolet (UV)-cured resin according to the wavelength of the light source and compare the shrinkage and expansion. Methods: We prepared the mold with according to the ISO 4049 specimen. The size of the circle in the mold was prepared with a height of 6.02 mm and a diameter of 4 mm. UV-curable resin for three-dimensional (3D) printing was injected into the circular mold. The control group was irradiated with a wavelength of 400~405 nm using UV-curing equipment (400 group), and the experimental group was irradiated with a wavelength of 460~465 nm (460 group). Both groups were produced ten specimens. The produced specimen was first measured with a digital micrometer. After the first measurement, the specimen was immersed in a constant temperature water bath for 15 days, after which the second measurement was performed, and the third measurement was taken after 30 days. The measured values were analyzed using the independent sample t-test (α=0.05). Results: In the non-immersion water tank, the contraction was 0.9% in the 400 group and 1.3% in the 460 group. In the constant temperature bath, the expansion was high at -0.4% in the 400 group for 15 days, and the smallest expansion was -0.03% for the 400 group for 30 days. There were significant differences between the two groups (p<0.05). Conclusion: The 400 group had a lower UV resin specimen strain than the 460 group. Therefore, it is recommended to use the wavelength required by the UV-curing resin.

Keywords

References

  1. Kim DY, Kim JH, Kim HY, Kim WC. Comparison and evaluation of marginal and internal gaps in cobalt-chromium alloy copings fabricated using subtractive and additive manufacturing. J Prosthodont Res. 2018;62:56-64. https://doi.org/10.1016/j.jpor.2017.05.008
  2. Eom DY, Leesungbok R, Lee SW, Park SJ, Ahn SJ. CAD/ CAM fabricated complete denture using 3D face scan: a case report. J Korean Acad Prosthodont. 2017;55:436-443. https://doi.org/10.4047/jkap.2017.55.4.436
  3. Jin SJ, Kim DY, Kim JH, Kim WC. Accuracy of dental replica models using photopolymer materials in additive manufacturing: in vitro three-dimensional evaluation. J Prosthodont. 2019;28:e557-e562. https://doi.org/10.1111/jopr.12928
  4. Shin MS, Paek JH. Flapless implant placement with digital 3D imaging and planning system in fully edentulous patient: a case report and 5-year follow-up. J Korean Acad Prosthodont. 2019;57:312-320. https://doi.org/10.4047/jkap.2019.57.3.312
  5. Do HS, Kim DJ, Kim HJ. Application of UV-curable materials. J Adhes Interface. 2003;4:41-51.
  6. Kim DY. Difference between shrinkage rate of irradiation amount of 3D printing UV curable resin and shrinkage rate according to a constant temperature water bath. J Kor Aca Den Tec. 2020;42:113-120. https://doi.org/10.14347/KADT.2020.42.2.113
  7. Walsh LJ. The current status of laser applications in dentistry. Aust Dent J. 2003;48:146-155. https://doi.org/10.1111/j.1834-7819.2003.tb00025.x
  8. Shin DH, Park YM, Park SH. Correlation between UVdose and shrinkage amounts of post-curing process for precise fabrication of dental model using DLP 3D printer. J Korean Soc Manuf Process Eng. 2018;17:47-53.
  9. Park JS, Park MG. Effect of aging treatment on the flexural properties of polymer provisional restoration materials. Korean J Dent Mater. 2013;40:215-221.
  10. International Organization for Standardization. Dentistry: polymer-based filling, restorative and luting materials. 4th ed. Geneva: ISO, 2009.
  11. ASTM International. ASTM C326-09, standard test method for drying and firing shrinkages of ceramic whiteware clays. West Conshohocken (PA): ASTM International, 2009.
  12. Lee SJ. Wear behavior of alumina-glass composites prepared by melt infiltration. J Korean Ceram Soc. 2003;40:881-885. https://doi.org/10.4191/KCERS.2003.40.9.881
  13. Lee SH, Kim DJ, Hwang YC, Oh WM, Hwang IN. Study on the interface between light-cured glass ionomer base and indirect composite resin inlay and dentin. J Korean Acad Conserv Dent. 2005;30:158-169. https://doi.org/10.5395/JKACD.2005.30.3.158
  14. Cho NY, Lee IB. Polymerization shrinkage, hygroscopic expansion and microleakage of resin-based temporary filling materials. Restor Dent Endod. 2008;33:115-124.