• Title/Summary/Keyword: Dental Instrument

Search Result 227, Processing Time 0.027 seconds

EFFECT OF INSTRUMENT COMPLIANCE ON THE POLYMERIZATION SHRINKAGE STRESS MEASUREMENTS OF DENTAL RESIN COMPOSITES (측정장치의 compliance 유무가 복합레진의 중합수축음력의 측정에 미치는 영향)

  • Seo, Deog-Gyu;Min, Sun-Hong;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.2
    • /
    • pp.145-153
    • /
    • 2009
  • The purpose of this study was to evaluate the effect of instrument compliance on the polymerization shrinkage stress measurements of dental composites. The contraction strain and stress of composites during light curing were measured by a custom made stress-strain analyzer, which consisted of a displacement sensor, a cantilever load cell and a negative feedback mechanism. The instrument can measure the polymerization stress by two modes: with compliance mode in which the instrument compliance is allowed, or without compliance mode in which the instrument compliance is not allowed. A flowable (Filtek Flow: FF) and two universal hybrid (Z100: Z1 and Z250: Z2) composites were studied. A silane treated metal rod with a diameter of 3.0 mm was fixed at free end of the load cell, and other metal rod was fixed on the base plate. Composite of 1.0 mm thickness was placed between the two rods and light cured. The axial shrinkage strain and stress of the composite were recorded for 10 minutes during polymerization. and the tensile modulus of the materials was also determined with the instrument. The statistical analysis was conducted by ANOVA. paired t-test and Tukey's test (${\alpha}<0.05$). There were significant differences between the two measurement modes and among materials. With compliance mode, the contraction stress of FF was the highest: 3.11 (0.13). followed by Z1: 2.91 (0.10) and Z2: 1.94 (0.09) MPa. When the instrument compliance is not allowed, the contraction stress of Z1 was the highest: 17.08 (0.89), followed by FF: 10.11 (0.29) and Z2: 9.46 (1.63) MPa. The tensile modulus for Z1, Z2 and FF was 2.31 (0.18), 2.05 (0.20), 1.41 (0.11) GPa, respectively. With compliance mode. the measured stress correlated with the axial shrinkage strain of composite: while without compliance the elastic modulus of materials played a significant role in the stress measurement.

The effectiveness of optical coherence tomography for evaluating peri-implant tissue: A pilot study

  • Sanda, Minoru;Shiota, Makoto;Imakita, Chiharu;Sakuyama, Aoi;Kasugai, Shohei;Sumi, Yasunori
    • Imaging Science in Dentistry
    • /
    • v.46 no.3
    • /
    • pp.173-178
    • /
    • 2016
  • Purpose: Optical coherence tomography (OCT) has been investigated as a novel diagnostic imaging tool. The utilisation of this equipment has been evaluated through several studies in the field of dentistry. The aim of this preliminary study was to determine through basic experiments the effectiveness of OCT in implant dentistry. Materials and Methods: To assess detection ability, we captured OCT images of implants in each of the following situations: (1) implants covered with mucosae of various thicknesses that were harvested from the mandibles of pigs; (2) implants installed in the mandibles of pigs; and (3) implants with abutments and crowns fixed with temporary cement. The OCT images were captured before cementation, after cementation, and after removing the excess submucosal cement. Results: If the thickness of the mucosa covering the implant body was less than 1 mm, the images of the implants were clearly detected by OCT. In the implants were installed in pigs' mandibles, it was difficult to capture clear images of the implant and alveolar bone in most of the samples. Remnants of excess cement around the implants were visible in most samples that had a mucosa thickness of less than 3 mm. Conclusion: Currently, OCT imaging of implants is limited. Cement remnants at the submucosal area can be detected in some cases, which can be helpful in preventing peri-implant diseases. Still, though there are some restrictions to its application, OCT could have potential as an effective diagnostic instrument in the field of implant dentistry as well.

Effect of Feedrate and Specimen Shape on Cutting Force and Surface Roughness of Ultrasonic Dental Surgical Instrument (치과용 초음파 수술기의 이송속도 및 시편형상이 절삭반력과 표면거칠기에 미치는 영향)

  • Sang Ho Kim;Seung Han Yang;Joong Ho Lee;Jong Kyun Choi
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.109-117
    • /
    • 2023
  • In this study, the effect of the shape of the specimen and the feedrate of the dental ultrasonic surgical instrument on the cutting force and surface roughness of the specimen is analyzed. Experimental specimens were made of SAWBONES artificial bone materials in square and spherical specimens. In addition, the cutting feedrate of the surgical instrument was controlled through the developed moving system. The cutting force generated when cutting the specimen was measured through a force sensor. After the experiment, the cutting surface of the specimen was observed through a three-dimensional optical microscope and the surface roughness was measured. Through one-way ANOVA, the effect of each specimen shape and feed rate on surface roughness was analyzed. As a result of the experiment, the cutting force increased proportionally in the initial feed rate increase stage, but the increase in cutting force decreased as the feed rate continued to increase. Also, the cutting force showed a difference according to the shape of the specimen. The spherical specimen with a relatively small cutting surface area had less cutting force than the square specimen. However, as a result of one-way ANOVA, it was found that the specimen shape and feed rate did not affect the surface roughness. In future studies, it is expected to be used for comparative analysis of ultrasonic surgical instruments and correlation analysis between cutting factors.

Analysis of the knowledge and insurance screening review rates of health insurance claims in the dental hygienist (일부 지역 치과위생사의 치과 건강보험에 관한 지식 및 심사조정률에 미치는 요인)

  • Park, Sin Young;Moon, Hye Ri
    • Journal of Korean society of Dental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.353-361
    • /
    • 2015
  • Objectives: The purpose of the study is to investigate the level of knowledge and screening review rates of dental health insurance claims in dental hygienists. This analysis will provide the educational information to the dental hygienists. Methods: A self-reported questionnaire was completed by dental hygienists in Jeonbuk from December 17, 2012 to January 24, 2013. The questionnaire was distributed by ordinary mail or direct visit. Except incomplete answers, 350 data were collected and analyzed. The study instrument was adapted from the structured questionnaire by Hong and Yoo. The questionnaire consisted of education experience of health insurance management, subjective and objective knowledge, insurance screening review, and need for health insurance education. Data were analyzed by SPSS 12.0 program. Cronbach alpha in the objective knowledge on health insurance rate criteria was 0.836 and this was a reliable figure. Results: The subjective knowledge level of dental insurance was higher in the senior dental hygienists. Subgingival curettage was the lowest percentage of correct answers in the objective knowledge. In recent six months, higher review control rate was shown in the higher claim for health insurance and insurance screening review. Conclusions: The majority of the respondents had lower level of knowledge of health insurance claims. The continuous education of dental health insurance will be necessary in the dental hygienists.

치과주조용 금-은-팔라듐합금의 물리적 특성에 관한 연구

  • Kim, Cheol-We
    • The Journal of the Korean dental association
    • /
    • v.20 no.12 s.163
    • /
    • pp.1073-1081
    • /
    • 1982
  • The purpose of this study was to measure and compare the tensile strengths, elongation and Vicker's hardness values by heat treatments of three·commercial dental casting gold-silver-palladium alloys(Type A,B and G-50 alloys) used in Korea. Instron universal testing instrument and Vicker's hardness tester were used to determine their physical properties. The following results were obtained with the alloys tested. 1. It was determined that the tensile strengths generally tended to increase as the hardened condition (55.50 - 72.98 Kg/mm₂)than in softened condition (28.75 - 41.16 Kg/mm₂). 2. The results indicated that the elongation was the highest in the softened condition(12.30 - 27.0 %), and was the smallest in the hardened condition (3.6 - 5.8 %). 3. It was found that the Vicker's hardness number was the greatest in type G-50 hardened alloys (304.0), and the smallest in the type A softened alloys (130.0).

  • PDF

A convergence study on dental infection management awareness and experience of dental users (치과이용자의 치과 감염관리 인식과 경험에 관한 융복합 연구)

  • Kim, Seol-Hee;Oh, Se-Li;Lee, Seul
    • Journal of Digital Convergence
    • /
    • v.18 no.11
    • /
    • pp.329-336
    • /
    • 2020
  • The study investigated the perception and experience of infection control targeting dental users. During July-August 2020, 198 adults over the age of 20 were surveyed on general characteristics, infection control awareness and experience, and improvement. Analysis was performed using PASW Statistics ver 18.0. The research results, 91% of dental users recognized that infection control was important. In the recognition of infection control were highly investigated oral treatment equipment sterilization, hand hygiene and glove replacement before and after treatment by dental staff. And dental users was relatively low the replacement of disposable gowns and safety glasses for each patient by medical staff. The dental staff are doing well in personal protection and instrument sterilization. Surface disinfection and water quality management needed improvement. It was meaningful to suggest improvement in infection control based on the perception and experience from the perspective of dental users. It is expected to be used as basic data necessary for high-quality medical services through infection control in dental medical institutions.

Evaluation of the Reliability of Salivary Testing Instrument (타액검사기의 신뢰도 평가)

  • Han, Keumah;Lee, Joonhaeng
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.3
    • /
    • pp.363-369
    • /
    • 2018
  • A salivary testing instrument has an advantage that the method is simple and can be performed in a short time. However, it is necessary to verify the factors that affect the reliability of the result, because the device is easy to use and even saliva collection is simple. The aim of this study was to compare the difference of the test results according to the measurement time in order to analyze the time factor of the external variable among the factors that may affect the measurement results of the salivary testing instrument. The relationship between the measured values of the salivary testing instrument to identify the internal variables was analyzed. Saliva was collected from 20 randomly selected patients regardless of age, sex, or diseases. The mean age was 46.6 years, 10 males and 10 females. The saliva collected was directly measured with the salivary testing instrument as group I. The saliva samples were placed in air in a paper cup for 10 minutes, and then measured as group III. Then group I was remeasured after 30 minutes and assigned as group II. Group III was remeasured after 30 minutes and called as group IV. As a result, all of the cariogenic bacteria, acidity, buffer capacity, blood, leukocyte, protein and ammonia, except buffer capacity, showed statistically significant changes in group II and IV. This means that the reliability of the test results is poor if the measurement time is not observed. Cariogenic bacteria were correlated with leukocyte and protein, buffer capacity was related to acidity, protein, and protein was related to buffer capacity and leukocyte. In conclusion, the result according to the measurement time as the external variable was different, which means that time must be strictly monitored when testing saliva. It is also necessary to take into account the relevance of the correlations between the internal variables and the clinical data.

The survey on the infection control of noncritical instruments used in dental treatment (치과 치료에 사용되는 비위험 기구의 감염 관리 실태 조사)

  • Kim, Jae Hyun;Lee, Jin-Han
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.35 no.1
    • /
    • pp.27-36
    • /
    • 2019
  • Purpose: The aims of this study were to evaluate the dentist's awareness and the actual status of infection control of noncritical dental instruments. Materials and Methods: 40 dental clinics in Daejeon, South Chungcheong, North Chungcheong and North Jeolla provinces were surveyed. The questionnaire was delivered to the dentists belonging to those clinics, and the awareness and the practice of infection control were examined. The microbial contamination on the surface of five noncritical instruments (impression gun, light curing unit, 3-way syringe, shade guide, and dental floss dispenser) used by them was measured with an ATP luminometer. Correlation analysis between the awareness and the actual state of infection control was conducted. Results: Awareness and frequency of infection control was highest in the 3-way syringe. Surface disinfection using disinfectant was most frequent in all instruments. 3-way syringes and shade guides were less contaminated than impression guns, light curing units, and dental floss dispensers. Conclusion: 3-way syringes had a significant correlation between user awareness of infection control and surface contamination, and the higher awareness, the lower the contamination measurement was shown.

Research on the actual condition of career decision-making self-efficacy·career decision level and career preparation behavior on Department of Dental Hygiene, K university (K 대학 치위생학과 학생들의 진로결정자기효능감·진로결정수준·진로준비행동 실태 조사)

  • Lee, Sook-Jeong;Lee, Ye Jong
    • Journal of the Korea Convergence Society
    • /
    • v.3 no.2
    • /
    • pp.27-32
    • /
    • 2012
  • The purpose of this study was to find out the effect of self-efficacy, career decision-making styles, and career decision-making level of the college the department of Dental Hygiene 1,2,3 students. The subjects of this study were 106 university students of the department of Dental Hygiene in K university. The instrument employed were the Career Decision Making Self Efficacy Scale, career decision level, career preparation behavior.The data collected were analyzed using Frequency analysis, t-test, Regression analysis and the pearson correlation of the spss 19.0 version.

The utilization of video laryngoscopy in nasotracheal intubation for oral and maxillofacial surgical procedures: a narrative review

  • Seung-Hwa Ryoo;Kyung Nam Park;Myong-Hwan Karm
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.24 no.1
    • /
    • pp.1-17
    • /
    • 2024
  • The video laryngoscope is a novel instrument for intubation that enables indirect visualization of the upper airway. It is recognized for its ability to enhance Cormack-Lehane grades in the management of difficult airways. Notably, video laryngoscopy is associated with equal or higher rates of intubation success within a shorter time frame than direct laryngoscopy. Video laryngoscopy facilitates faster and easier visualization of the glottis and reduces the need for Magill forceps, thereby shortening the intubation time. Despite the advanced glottic visualization afforded by video laryngoscopy, nasotracheal tube insertion and advancement occasionally fail. This is particularly evident during nasotracheal intubation, where oropharyngeal blood or secretions may obstruct the visual field on the monitor, thereby complicating video laryngoscopy. Moreover, the use of Magill forceps is markedly challenging or nearly unfeasible in this context, especially in pediatric cases. Furthermore, the substantial blade size of video laryngoscopes may restrict their applicability in individuals with limited oral apertures. This study aimed to review the literature on video laryngoscopy, discuss its clinical role in nasotracheal intubation, and address the challenges that anesthesiologists may encounter during the intubation process.