• 제목/요약/키워드: Dental Implant System

검색결과 330건 처리시간 0.027초

밀링 공구의 마모가 PMMA 임플란트 임시보철물 변연 및 내면적합도에 미치는 영향 (Effect of milling tool wear on the internal fit of PMMA implant interim prosthesis)

  • 신미선
    • 대한치과기공학회지
    • /
    • 제41권2호
    • /
    • pp.63-69
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the effect of CAD/CAM system milling tool wear on the marginal and internal fit of PMMA implant interim prosthesis three-dimensional manner. Methods: A total of 20 crowns were fabricated with CAD/CAM method. Their designs were unified to first molar of the left maxilla. The Customized abutments were prepared and scanned with on optical model scanner. Five crowns were milled by the newly replaced tool (1st milling), and 15 crowns were milled by 2nd, 3rd, 4th milling tool. The marginal and internal fit of 20 interim crowns were measured using the triple-scan protocol. Results: Statistically significant difference was found between the $1^{st}$ milling group ($51.8{\pm}14.6{\mu}m$) and the $3^{rd}$, $4^{th}$ milling group ($128.6{\pm}43.8{\mu}m$, $146.2{\pm}38.1{\mu}m$, respectively) at the distal margins. In the mesial margins, There was a statistically significant difference between the $1^{st}$ milling group ($63.6{\pm}25.9{\mu}m$) and the $3^{rd}$, $4^{th}$ milling group ($137.2{\pm}25.9{\mu}m$, $186.8{\pm}70.6{\mu}m$, respectively). In the distal line angle, significant difference was found between the $1^{st}$, $2^{nd}$, $3^{rd}$ milling groups and the $4^{th}$ milling group. In the mesial axial wall, significant difference was found between the $1^{st}$ milling group ($52.2{\pm}20.3{\mu}m$) and the $3^{rd}$, $4^{th}$ milling groups ($22.8{\pm}8.8{\mu}m$, $7.8{\pm}5.7{\mu}m$). Conclusion: As a result of the experiment, decrease of the marginal and internal fit was statistically significant as the number of machining cycles increased. In order to produce clinically excellent restorations, it is recommandable to consider the condition of the milling tool wear, when designing the restoration with CAD program.

지대주 나사 풀림 방지를 위한 새로운 Lock Screw 시스템의 효과에 대한 유한요소해석적 연구 (Finite element analysis of the effect of novel Lock Screw system preventing abutment screw loosening)

  • 임은섭;김종은;김지환;박영범
    • 구강회복응용과학지
    • /
    • 제35권3호
    • /
    • pp.132-142
    • /
    • 2019
  • 목적: 본 유한요소해석적 연구는 새로운 Lock screw 시스템을 소개하고 그 역학적 특성을 분석하여 Lock screw가 지대주 나사 풀림을 방지할 수 있는지 알아보려고 한다. 연구 재료 및 방법: Lock screw는 임플란트 지대주 내부에 체결하여 지대주 나사 두부에 압축력을 가하는 장치이다. 그 효과를 알아보기 위해 CAD 프로그램을 이용하여 모델링을 하였고, 이를 다양한 하중조건 하에서 유한요소해석법을 이용해 분석하였다. 우선 지대주 나사의 조임회전력에 따른 전하중을 측정하고 이론 값과 비교하여 해석모델을 검증하였다. 검증된 해석 모델을 외부 하중이 없는 것과 178 N을 부여한 것으로 나누어 Lock screw의 조임회전력을 각각 10, 20, 30 Ncm으로 변화시켰고, 이때 임플란트 구성요소의 응력 분포가 어떠한 특성을 보이는지 살펴보았다. 결과: 여러 하중조건 하에서 Lock screw의 사용은 임플란트 구성요소의 항복강도를 넘어서는 등가응력을 발생시키지 않았다. 또한 지대주-지대주 나사 계면에서 축방향 하중의 증가를 보였다. 결론: Lock screw의 사용은 임플란트 구성요소에 과도한 응력을 가하지 않으며, 지대주-지대주 나사 계면의 마찰력을 증가시켜 지대주 나사 풀림을 방지할 수 있을 것으로 판단된다.

내부연결 임플란트용 타이타늄 소켓을 이용한 지르코니아 지대주에서 열순환이 나사풀림에 미치는 영향: 예비연구 (The effect of a titanium socket with a zirconia abutment on screw loosening after thermocycling in an internally connected implant: a preliminary study)

  • 경규영;차현석;이주희
    • 구강회복응용과학지
    • /
    • 제33권2호
    • /
    • pp.114-118
    • /
    • 2017
  • 목적: 이 연구의 목적은 타이타늄 구성요소를 가진 지르코니아 지대주가 내부연결 임플란트에 사용되었을 때 나사 풀림에 대해 알아보는 것이다. 열순환 후 타이타늄 소켓을 가진 지르코니아 지대주와 타이타늄 지대주의 나사 풀림과 제거력을 비교 분석하였다. 연구 재료 및 방법: 내측연결 임플란트와 내측연결 타이타늄 지대주, 타이타늄 소켓을 가진 외측연결 지르코니아 지대주를 준비하였다. 내부연결형 임플란트에 5개의 타이타늄 지대주를(대조군), 타이타늄 소켓을 가진 5개의 지르코니아 지대주(실험군)를 각각 연결하고 30 Ncm의 토크로 조인 후 열순환 처리 전후의 지대주 나사 제거력을 측정하였다. 각 시편들은 열순환 장치의 수조에서 $5^{\circ}C$$55^{\circ}C$의 물에 60초씩 교대로 2,000회의 열순환을 시행하였다. 각 시편의 나사 풀림을 조사하고 열순환 전후에 나사 제거력을 통계학적으로 분석하였다. 결과: 두 그룹 모두에서 열순환 후 지대주 나사 풀림을 보이지 않았다. 열순환 전후의 나사 제거력 차이는 대조군에서 $-1.34{\pm}2.53Ncm$, 실험군에서 $-1.26{\pm}2.06Ncm$ 로 나타났다. 독립표본 T 통계분석 결과 두 군간에 유의한 차이를 보이지 않았다(P > 0.05). 결론: 이 실험의 결과 내에서 내부연결 임플란트를 위한 지르코니아 지대주 내 타이타늄 소켓이 열순환 후 지대주 나사풀림에 타이타늄 지대주와 비교하여 유의한 영향을 나타내지 않았다.

완전무치악환자의 전악 임플란트 치료 계획 수립을 위한 체계적인 접근법 (Rational treatment planning for implant treatment of the edentulous patients)

  • 배정인
    • 대한심미치과학회지
    • /
    • 제32권2호
    • /
    • pp.54-68
    • /
    • 2023
  • 디지털 방법을 사용한 무치악의 임플란트 치료계획은 surgical guide design으로 구체화된다. Surgical guide를 제작할 때, 우리는 먼저 최종 보철의 형태를 가상공간에 구현한 후 이를 바탕으로 식립 계획을 구체화하게 된다. 그러나 완전무치악 환자는 치아배열의 기준이 없고 악간관계가 정립되어 있지 않아 최종 보철의 형태를 짐작하기 어려워 surgical guide를 만드는 데 어려움이 있다. 이때 기존의 만족스러운 총의치나 부분의치, 잔존치 등이 존재한다면 그 치아배열이 가상적인 최종 보철의 reference가 될 수 있다. 만약 이러한 reference가 부재하거나 만족스럽지 못하다면, 진단용 목적으로 총의치를 제작하되 이를 구내에서 검증하는 과정이 필요하다. 이러한 과정을 통해 surgical guide를 제작할지라도 구내 상황에 따라 implant의 위치가 계획한 것과 다르게 식립될 수 있으며, 만약 guide의 positioning이 잘못된다면 그 오차는 모든 implant의 위치를 변위시킬 수 있으므로 guide 수술이 오히려 재앙으로 다가올 수 있다. 본 기고에서는 치아 배열의 reference가 될 수 있는 자료들을 적절한 시기에 채득하여 이를 디지털 공간에 이전 및 통일된 좌표계로 정렬하는 방법에 대해 논의하고, 또한 이렇게 수립된 식립계획을 현실의 구강에 적은 오차로 이전 및 정렬하는 방법에 대해 소개하여 일관적이고 체계적인 무치악 가이드 디자인의 프로토콜 정립에 대해 의견 개진하려 한다.

Improving Accuracy of Instance Segmentation of Teeth

  • Jongjin Park
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제16권1호
    • /
    • pp.280-286
    • /
    • 2024
  • In this paper, layered UNet with warmup and dropout tricks was used to segment teeth instantly by using data labeled for each individual tooth and increase performance of the result. The layered UNet proposed before showed very good performance in tooth segmentation without distinguishing tooth number. To do instance segmentation of teeth, we labeled teeth CBCT data according to tooth numbering system which is devised by FDI World Dental Federation notation. Colors for labeled teeth are like AI-Hub teeth dataset. Simulation results show that layered UNet does also segment very well for each tooth distinguishing tooth number by color. Layered UNet model using warmup trick was the best with IoU values of 0.80 and 0.77 for training, validation data. To increase the performance of instance segmentation of teeth, we need more labeled data later. The results of this paper can be used to develop medical software that requires tooth recognition, such as orthodontic treatment, wisdom tooth extraction, and implant surgery.

Reasonable necessity of preoperative laboratory tests in office-based oral and maxillofacial surgery

  • Mi Hyun Seo;Mi Young Eo;Kezia Rachellea Mustakim;Buyanbileg Sodnom-Ish;Hoon Myoung;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제49권3호
    • /
    • pp.142-147
    • /
    • 2023
  • Objectives: As medical history before surgery is often based on patient reporting, there is the possibility that patients intentionally hide underlying diseases or that dentists cannot recognize abnormal health states. Therefore, more professional and reliable treatment processes are needed under the Korean dental specialist system. The purpose of this study was to elucidate the necessity of a preoperative blood testing routine prior to office-based surgery under local anesthesia. Patients and Methods: Preoperative blood lab data for 5,022 patients from January 2018 to December 2019 were assembled. Study participants were those who underwent extraction or implant surgery under local anesthesia at Seoul National University Dental Hospital. Preoperative blood tests included complete blood count (CBC), blood chemistry, serum electrolyte, serology, and blood coagulation data. Values outside of the normal range were considered an "abnormality," and the percentage of abnormalities among the total number of patients was calculated. Patients were divided into two groups based on the presence of underlying disease. The rates of abnormalities in the blood tests were compared between groups. Chi-square tests were performed to compare data from the two groups, and P<0.05 was considered statistically significant. Results: The percentages of males and females in the study were 48.0% and 52.0%, respectively. Of all patients, 17.0% (Group B) reported known systemic disease, while 83.0% (Group A) reported no specific medical history. There were significant differences between Groups A and B in CBC, coagulation panel, electrolytes, and chemistry panel (P<0.05). In Group A, the results of blood tests that required a change in procedure were identified even though the proportion was very small. Conclusion: Preoperative blood tests for office-based surgery can detect underlying medical conditions that are difficult to identify from patient history alone and can prevent unexpected sequelae. In addition, such tests can result in a more professional treatment process and build patient confidence in the dentist.

Salivary soluble receptor activator of nuclear factor kappa B ligand/osteoprotegerin ratio in periodontal disease and health

  • Tabari, Zahra Alizadeh;Azadmehr, Abbas;Tabrizi, Mohammad Amir Alizadeh;Hamissi, Jalaloddin;Ghaedi, Fatemeh Baharak
    • Journal of Periodontal and Implant Science
    • /
    • 제43권5호
    • /
    • pp.227-232
    • /
    • 2013
  • Purpose: The receptor activator of nuclear factor kappa B (RANK)/RANK ligand (RANKL)/osteoprotegerin (OPG) system plays a significant role in osteoclastogenesis, activation of osteoclasts, and regulation of bone resorption. This study aimed to evaluate the use of the salivary soluble RANKL (sRANKL)/OPG ratio as a diagnostic marker for periodontitis in nonsmokers. Methods: Twenty-five patients with chronic periodontitis and 25 individuals with a healthy periodontium were enrolled in this study. Samples containing 5 mL of unstimulated saliva were obtained from each subject. Salivary sRANKL and OPG concentrations were determined using a standard enzyme-linked immunosorbent assay. Statistical analysis was performed using SPSS ver. 18.0. Results: The levels of sRANKL and OPG were detectable in all of the samples. Positive relationships were found between the plaque index and clinical attachment level and both the salivary concentration of sRANKL and the salivary sRANKL/OPG ratio (P<0.05). The salivary concentration of sRANKL and the sRANKL/OPG ratio were significantly higher in the periodontitis group than in the healthy group (P=0.004 and P=0.001, respectively). In contrast, the OPG concentration showed no significant differences between the groups (P=0.455). Conclusions: These findings suggest that the salivary sRANKL/OPG ratio may be helpful in the screening and diagnosis of periodontitis. However, longitudinal studies with larger populations are needed to confirm these results.

Comparison of the effect of hand instruments, an ultrasonic scaler, and an erbium-doped yttrium aluminium garnet laser on root surface roughness of teeth with periodontitis: a profilometer study

  • Amid, Reza;Kadkhodazadeh, Mahdi;Fekrazad, Reza;Hajizadeh, Farzin;Ghafoori, Arash
    • Journal of Periodontal and Implant Science
    • /
    • 제43권2호
    • /
    • pp.101-105
    • /
    • 2013
  • Purpose: The present study aimed to measure root surface roughness in teeth with periodontitis by a profilometer following root planning with ultrasonic and hand instruments with and without erbium-doped yttrium aluminium garnet (Er:YAG) laser irradiation. Methods: Sixty single-rooted maxillary and mandibular teeth, extracted because of periodontal disease, were collected. The crowns and apices of the roots were cut off using a diamond bur and water coolant. The specimens were mounted in an acrylic resin block such that a plain root surface was accessible. After primary evaluation and setting a baseline, the samples were divided into 4 groups. In group 1, the samples were root planned using a manual curette. The group 2 samples were prepared with an ultrasonic scaler. In group 3, after scaling with hand instrumentation, the roots were treated with a Smart 1240D plus Er:YAG laser and in group 4, the roots were prepared with ultrasonic scaler and subsequently treated with an Er:YAG laser. Root surface roughness was then measured by a profilometer (MahrSurf M300+RD18C system) under controlled laboratory conditions at a temperature of $25^{\circ}C$ and 41% humidity. The data were analyzed statistically using analysis of variance and a t-test (P<0.05). Results: Significant differences were detected in terms of surface roughness and surface distortion before and after treatment. The average reduction of the surface roughness after treatment in groups 1, 2, 3, and 4 was 1.89, 1.88, 1.40, and 1.52, respectively. These findings revealed no significant differences among the four groups. Conclusions: An Er:YAG laser as an adjunct to traditional scaling and root planning reduces root surface roughness. However, the surface ultrastructure is more irregular than when using conventional methods.

치의학 교육의 새로운 트렌드 : 구글 클래스룸을 이용한 플립드 러닝(Flipped learning)의 적용 및 평가 (New trend of dental education: flipped learning for dental classes using Google classroom platform)

  • 공준형;문호진;박정철
    • 디지털콘텐츠학회 논문지
    • /
    • 제17권5호
    • /
    • pp.317-327
    • /
    • 2016
  • 플립드 러닝(flipped learning)은 온라인 및 오프라인을 포함한 둘 이상의 상이한 학습 환경을 혼합하여 학습 효과를 극대화 할 수 있는 새로운 학습 테크닉으로써, 최근 등장한 'Google classroom' 서비스는 플립드 러닝에 최적화된 토탈 솔루션이다. 본 연구는 국내 최초로 D 치과대학 치의학과 본과 2학년 학생들 70명에게 구글 클래스룸 플랫폼을 이용한 플립드 러닝을 적용 후 학생들의 만족도를 평가하였다. 치주과학 개론 및 치과보존학 아말감 수복학 두 과목을 선정하여 6회의 강의 중 3회는 전통적 수업방식으로, 나머지 3회는 구글 클래스룸을 포맷으로 한 플립드 러닝으로 진행하였다. 만족도 평가는 강의가 모두 완료된 후 설문을 통해 진행되었다. 본 연구를 통해, 치과대학 수업에의 플립드 러닝 적용은 이해도, 자기주도적 학습과 학습 동기면에서 높은 효율 및 만족도를 보였고 학생들은 매우 긍정적인 학습효과를 보였다. 결과적으로, 구글 클래스룸을 활용한 플립드 러닝은 치과대학 수업에서 효과적인 플랫폼임을 알 수 있었다.

Osstem USII plus 임플란트의 단기간 성공률 및 변연골 흡수량 평가 (Success rate and marginal bone loss of Osstem USII plus implants; Short term clinical study)

  • 김선근;김지환;이근우;조규성;한동후
    • 대한치과보철학회지
    • /
    • 제49권3호
    • /
    • pp.206-213
    • /
    • 2011
  • 연구 목적: 임플란트 경부까지RBM 표면 처리를 한 Osstem$^{(R)}$ USII plus system (Osstem Co., Seoul, Korea)의 임상적 유용성을 평가하기 위하여 연세대학교 치과대학 병원에 내원한 환자 중 이 system을 이용하여 치료 받은 32명의 환자에게 식립된 88개의 임플란트를 대상으로 기능 부하 후 1년까지의 임상적, 방사선학적 결과를 후향적으로 분석하였다. 연구 재료 및 방법: 진료 기록부를 통해 전신 조건, 성별, 연령, 식립 위치, 식립 된 임플란트의 직경 및 길이 등을 조사하여 그에 따른 분포 및 생존율의 차이와 함께 이들 항목이 변연골 흡수량에 영향을 미치는지 조사하였다. 방사선사진 분석으로 임플란트 식립 시, 보철물 장착 후 6개월 내지 1년간의 변연골 흡수량을 측정하여 분석하였다. 각 항목과의 연관성 분석을 위하여 독립 t-검정(independent sample t-test)을 이용하였으며(${\alpha}$=.05), 보철물 장착 전과 보철물 장착 후 12개월 동안의 변연골 흡수량 비교를 위하여 일원 반복측정 분산 분석(one-way repeated-measures ANOVA)을 이용하였다(${\alpha}$=.05). 결과:총 32명에게 식립된 88개의 임플란트 중에서 실패한 것은 없었으며 누적 생존율은 100%로 나타났다. 임플란트 식립 시부터 보철물 장착까지의 변연골 흡수량은 0.24 mm이었으며, 보철물 장착 후 12개월까지의 변연골 흡수량은 평균 0.19 mm로 임플란트 식립 시부터 보철물 장착 12개월까지의 총 변연골 흡수량은 0.43 mm였다. 상악에 식립된 경우와 하악에 식립된 경우의 변연골 흡수량을 비교했을 때는 통계적으로 유의한 차이를 보이지 않았으나 구치부에 식립된 경우가 전치부에 식립된 경우에 비해 변연골 흡수량이 크게 나타났으며 이는 통계적으로 유의한 차이가 있었다. 결론: 이상의 결과를 토대로 보철물 장착 12개월까지의 기간 동안 임플란트 고정체의 경부까지 RBM 표면 처리를 한 외측 연결형의 국산 임플란트의 단기간 임상적인 성공률은 만족스러운 결과를 보였으며 변연골 흡수량도 임플란트 성공 기준에 부합하였다.