• Title/Summary/Keyword: Dental Implant System

Search Result 330, Processing Time 0.025 seconds

Full mouth rehabilitation with dental implant utilizing 3D digital image and CAD/CAM system: case report (3차원 디지털 영상과 CAD/CAM 시스템을 활용한 전악 임플란트 수복 증례)

  • Kang, Se-Ha;Jeong, Seung-Mi;Shin, Jae-Ok;Fang, Jeong-Whan;Kim, Dae-Hwan;Choi, Byung-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.31 no.2
    • /
    • pp.158-168
    • /
    • 2015
  • This article describes how to use digital system in a fully edentulous case that diagnosis to definitive prosthesis fabrication. While proceeding oral scan and CBCT taking, digital markers were attached on maxillary palate and lower existing denture. Using CBCT image and oral scan image, the bone contour and anatomical structures were analyzed and flapless surgical guide, customized abutment and prosthesis were made. After the osseointegration, the definitive prosthesis was fabricated using the oral scan image with scan body. It provides clinicians with a fast workflow and improves clinical efficiency.

Changes in dental care access upon health care benefit expansion to include scaling

  • Park, Hee-Jung;Lee, Jun Hyup;Park, Sujin;Kim, Tae-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.6
    • /
    • pp.405-414
    • /
    • 2016
  • Purpose: This study aimed to evaluate the effects of a policy change to expand Korean National Health Insurance (KNHI) benefit coverage to include scaling on access to dental care at the national level. Methods: A nationally representative sample of 12,794 adults aged 20 to 64 years from Korea National Health and Nutritional Examination Survey (2010-2014) was analyzed. To examine the effect of the policy on the outcomes of interest (unmet dental care needs and preventive dental care utilization in the past year), an estimates-based probit model was used, incorporating marginal effects with a complex sampling structure. The effect of the policy on individuals depending on their income and education level was also assessed. Results: Adjusting for potential covariates, the probability of having unmet needs for dental care decreased by 6.1% and preventative dental care utilization increased by 14% in the post-policy period compared to those in the pre-policy period (2010, 2012). High income and higher education levels were associated with fewer unmet dental care needs and more preventive dental visits. Conclusions: The expansion of coverage to include scaling demonstrated to have a significant association with decreasing unmet dental care needs and increasing preventive dental care utilization. However, the policy disproportionately benefited certain groups, in contrast with the objective of the policy to benefit all participants in the KNHI system.

Reestablishing the occlusal plane in full mouth rehabilitation patient, using Shilla system (전악수복환자에서 Shilla system을 이용한 교합평면 재구성 증례)

  • Yang, Min-Soo;Vang, Mong-Sook;Park, Sang-Won;Lim, Hyun-Phil;Yun, Kwi-Dug;Yang, Hong-So
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.1
    • /
    • pp.33-38
    • /
    • 2013
  • Occlusal plane is a sagittal expression of dental arch form, and it composes the shape of occlusion, which is one of the most important elements of Maxillo-oral system. In this case, vertical, horizontal coordinates of bionic-median-sagittal plane was produced in articulator, and to achieve relation of left and right position of upper, lower teeth and deficits in alveola, Shilla system was used to reconstruct occlusal plane. In this case, a 41 year-old male patient visited for fracture of 10 unit metal-ceramic fixed partial denture of upper anterior teeth and for overall treatment. Clinical, radiographical, model examination was held, full mouth rehabilitation was achieved by placing dental implant. Maxillo-oral relation was recorded using Gothic arch Tracer complex and were mounted. And for the next step, we estimated original occlusal plane using Shilla system. After analysis we produced diagnosis wax pattern. On the basis of this, radiography stent was manufactured and dental implant was placed, and temporary prosthesis was made by using diagnosis wax pattern. Cross mounting and anterior guiding table were performed in order to reproduce temporary restoration morphology and bite pattern, followed by final restoration made of all ceramic crown with zirconia coping. As stated above, appropriately esthetic and functional results can be seen in using Shilla system in diagnosis and treatment procedure of full mouth rehabilitation patient.

New maxillary anterior ridge classification according to ideal implant restorative position determined by CAT (전산화단층영상을 이용한 이상적 임플란트 수복 위치에 따른 상악 전치부 치조제의 새로운 분류)

  • Park, Young-Sang;Cho, Sang-Choon;Kim, Kyoung-Nam;Kim, Kwang-Mahn;Choi, Seong-Ho;Moon, Hong-Seok;Lee, Yong-Keun
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.sup2
    • /
    • pp.385-396
    • /
    • 2007
  • This study proposed a new classification system for maxillary anterior alveolar ridge deformities based on CAT-scan implant simulation as a useful concept in order to more precisely predict treatment outcomes and the necessity for ridge augmentation prior to implant placement. The results indicate that a high number of cases in the maxillary anterior area would require augmentation procedures in order to achieve ideal implant placement and restoration.

Effects of scaling and root planing with or without a local drug delivery system on the gingival crevicular fluid leptin level in chronic periodontitis patients: a clinico-biochemical study

  • Meharwade, Vinayak Venkoosa;Gayathri, Gunjiganur Vemanaradhya;Mehta, Dhoom Singh
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.3
    • /
    • pp.118-125
    • /
    • 2014
  • Purpose: The present split mouth study evaluates the effect of nonsurgical periodontal treatment on the gingival crevicular fluid (GCF) leptin level in chronic periodontitis. Methods: Ninety sites from 30 nonobese chronic periodontitis patients were selected and divided as follows: group I, 30 healthy sites receiving no treatment; group II, 30 periodontitis sites receiving scaling and root planing (SRP); and group III, 30 periodontitis sites receiving SRP with tetracycline local drug delivery. At baseline, after GCF sampling and clinical parameter recording, the assigned treatment was performed for the study groups. During recall visits, GCF sampling followed by clinical parameter recording was done for groups II and III. Results: Reductions in the probing depth and the clinical attachment level (CAL) were highly significant at different time intervals (except between day 0 and 45) in both groups II and III. Upon comparison, group III showed significant gain in CAL between day 0 and 15 and between day 0 and 45. After treatment, the reduction in the GCF leptin level was more significant in group III than in group II at day 15 but re-elevated almost to the pretreatment levels at day 45. Conclusions: Nonsurgical periodontal therapies were not effective in maintaining stable reduction in the GCF leptin level during the study period.

Screw joint stability according to abutment screw materials

  • Jeong Yong-Tae;Chung Chae-Heon;Lee Heung-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.3
    • /
    • pp.297-305
    • /
    • 2001
  • Statement of problem. There have been previous studies about instability according to screw material by means of calculating preload in tightening screw or recording of the torque necessary to loosen screw after tightening screw. Purpose. The purpose of this study was to evaluate screw joint stability through the analysis of fitness at the mating thread surfaces between implant and screw after tightening screws made of different materials. Material and methods. In this study, screws were respectively used to secure a cemented abutment to a hexlock implant fixture; teflon coated titanium alloy screw and titanium alloy screw(Steri-Oss), gold-plated gold-palladium alloy screw and titanium alloy screw(Implant Innovation), gold screw and titanium screw(AVANA Dental Implant System). Each abutment screw was secured to the implant with recommended torque value using a digital torque controller. Each screw was again tightened after 10minutes. All samples were cross sectioned with sandpaper and polished. Then samples were evaluated with an scanning electron microscope analysis. Results. In titanium alloy screw, irregular contact and relatively large gap was present at mating thread surface. Also in teflon-coated titanium screw, incomplete seating and only partially contact was present at the mating thread surface. In gold-plated gold-palladium alloy screw, relatively close and tight contact without the presence of large gap was present by existing of gold coating at the mating thread surfaces. In gold alloy screw, relatively small gap between the mating components was seen. Conclusions. This result suggested that gold plated gold-palladium alloy screw and gold alloy screw achieved a greater degree of contact at the mating thread surfaces compared to titanium alloy screw and teflon-coated titanium alloy screw.

  • PDF

STUDY OF MAXILLARY CORTICAL BONE THICKNESS FOR SKELETAL ANCHORAGE SYSTEM IN KOREAN (Skeletal Anchorage System의 식립을 위한 한국인 악골의 피질골 두께에 대한 연구)

  • Kim, Ji-Hyuck;Joo, Jae-Yong;Park, Young-Wook;Cha, Bong-Kuen;Kim, Soung-Min
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.28 no.4
    • /
    • pp.249-255
    • /
    • 2002
  • Recently, Skeletal Anchorage System (SAS) has been focused clinically with the view point that it could provide the absolute intraoral anchorage. First, it began to be used for the patient of orthognathic surgery who had difficulty in taking intermaxillary fixation due to multiple loss of teeth. And then, its uses have been extended to many cases, the control of bone segments after orthognathic surgery, stable anchorage in orthodontic treatment, and anchorage for temporary prosthesis and so on. SAS has been developed as dental implants technique has been developed and also called in several names; mini-screw anchorage, micro-screw anchorage, mini-implant anchorage, micro-implant anchorage (MIA), and orthosystem implant etc. Now many clinicians use SAS, but the anatomical knowledges for the installed depth of intraosseous screws are totally dependent on general experiences. So we try to study for the cortical thickness of maxilla and mandible in Korean adults without any pathologic conditions with the use of Computed Tomography at the representative sites for the screw installation.

Development and application of stent-based image guided navigation system for oral and maxillofacial surgery (구강외과 수술용 스텐트 기반 영상유도 수술 시스템의 개발)

  • Lee, Woo-Jin;Kim, Dae-Seung;Yi, Won-Jin;Lee, Sam-Sun;Choi, Soon-Chul;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Myung-Jin;Lee, Jee-Ho
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.149-156
    • /
    • 2009
  • Purpose : The purpose of this study was to develop a stent-based image guided surgery system and to apply it to oral and maxillofacial surgeries for anatomically complex sites. Materials and Methods : We devised a patient-specific stent for patient-to-image registration and navigation. Three-dimensional positions of the reference probe and the tool probe were tracked by an optical camera system and the relative position of the handpiece drill tip to the reference probe was monitored continuously on the monitor of a PC. Using 8 landmarks for measuring accuracy, the spatial discrepancy between CT image coordinate and physical coordinate was calculated for testing the normality. Results : The accuracy over 8 anatomical landmarks showed an overall mean of $0.56{\pm}0.16\;mm$. The developed system was applied to a surgery for a vertical alveolar bone augmentation in right mandibular posterior area and possible interior alveolar nerve injury case of an impacted third molar. The developed system provided continuous monitoring of invisible anatomical structures during operation and 3D information for operation sites. The clinical challenge showed sufficient accuracy and availability of anatomically complex operation sites. Conclusion : The developed system showed sufficient accuracy and availability in oral and maxillofacial surgeries for anatomically complex sites.

  • PDF

Trends in the utilization of dental outpatient services affected by the expansion of health care benefits in South Korea to include scaling: a 6-year interrupted time-series study

  • Park, Hee-Jung;Lee, Jun Hyup;Park, Sujin;Kim, Tae-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.1
    • /
    • pp.3-11
    • /
    • 2018
  • Purpose: This study utilized a strong quasi-experimental design to test the hypothesis that the implementation of a policy to expand dental care services resulted in an increase in the usage of dental outpatient services. Methods: A total of 45,650,000 subjects with diagnoses of gingivitis or advanced periodontitis who received dental scaling were selected and examined, utilizing National Health Insurance claims data from July 2010 through November 2015. We performed a segmented regression analysis of the interrupted time-series to analyze the time-series trend in dental costs before and after the policy implementation, and assessed immediate changes in dental costs. Results: After the policy change was implemented, a statistically significant 18% increase occurred in the observed total dental cost per patient, after adjustment for age, sex, and residence area. In addition, the dental costs of outpatient gingivitis treatment increased immediately by almost 47%, compared with a 15% increase in treatment costs for advanced periodontitis outpatients. This policy effect appears to be sustainable. Conclusions: The introduction of the new policy positively impacted the immediate and long-term outpatient utilization of dental scaling treatment in South Korea. While the policy was intended to entice patients to prevent periodontal disease, thus benefiting the insurance system, our results showed that the policy also increased treatment accessibility for potential periodontal disease patients and may improve long-term periodontal health in the South Korean population.

AN EXPERIMENTAL EXAMINATION OF MULTIMODAL IMAGING SYSTEM FOR IMPLANT SITE ASSESSMENT (인공치아 이식부위 분석을 위한 다기능 영상체계의 실험적 검사)

  • Park Chang-Seo;Kim Kee-Deog
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.1
    • /
    • pp.7-16
    • /
    • 1998
  • The Scanora/sup (R)/ X-ray unit uses the principles of narrow beam radiography and spiral tomography. Starting with a panoramic overview as a scout image. multiple tomographic projections could be selected. This study evaluated the accuracy of spiral tomography in comparison to routine panoramic radiography for dental implant treatment planning. An experimental study was performed on a cadaver mandible to assess the accuracy of panoramic radiography and spiral tomography film images for measurement of metallic spheres. After radiographic images of the metallic spheres on the surgical stent were measured and corrected for a fixed magnification of radiographic images. following results were obtained. 1. In the optimal position of the mandible. the minimal horizontal and vertical distortion was evident in the panoramic radiography images. The mean horizontal and vertical magnification error in anterior sites was 5.25% and 0.75%. respectively. The mean horizontal and vertical magnification error in posterior sites was 0.50% and 1.50%. respectively. 2. In the displaced forward or in an eccentric position of the mandible. the magnification error of the panoramic radiography images increased significantly over the optimal position. Overall, the mean horizontal magnification error of the anterior site in the different positions changed dramatically within a range of -17.25% to 39.00%, compared to the posterior range of -5.25% to 8.50%. However, the mean vertical magnification error stayed with the range of 0.5% to 3.75% for all the mandibular positions. 3. The magnification effects in the tomographic scans were nearly identical for the anterior and posterior with a range of 2.00% to 5.75% in the horizontal and 4.50% to 5.50% in the vertical dimension, respectively. 4. A statistically significant difference between the anterior and posterior measurements was found in the horizontal measurements of the panoramic radiography images of the displaced forward and backward position of the mandible(P<0.05). Also a significant difference between the optimal panoramic and tomographic projections was found only in the vertical measurement(P<0.05).

  • PDF