• Title/Summary/Keyword: Dental Implant System

Search Result 330, Processing Time 0.025 seconds

Evaluation of Artifacts by Dental Metal Prostheses and Implants on PET/CT Images: Phantom and Clinical Studies (PET/CT 영상에서의 치과재료에 의한 인공물에 관한 연구)

  • Bahn, Young-Kag;Park, Hoon-Hee;NamKoong, Hyuk;Cho, Suk-Won;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.110-116
    • /
    • 2010
  • Purpose: The X-ray attenuation coefficient based on CT images is used for attenuation correction in PET/CT. The polychromatic X-ray beam can introduce beam-hardening artifact on CT images. The aims of the study were to evaluate the effect of dental metal prostheses in phantom and patients on apparent tracer activity measured with PET/CT when using CT attenuation correction. Materials and Methods: 40 normal patients (mean age $54{\pm}12$) was scanned between Jan and Feb 2010. NEMA(National Electrical Manufactures Association) PET $Phantom^{TM}$ (NU2-1994) was filled with $^{18}F$-FDG injected into the water that insert implant and metal prostheses dental cast. Region of interest were drawn in non-artifact region, bright steak artifact region and dark streak artifact region on the same transaxial CT and PET slices. Patients and phantom with dental metal prostheses and dental implant were evaluated the change rate of CT Number and $SUV_{mean}$ in PET/CT. A paired t-test was performed to compare the ratio and the difference of the calculated values. Results: In patients with dental metal prostheses, $SUV_{mean}$ was reduced 19.64% (p<0.05) in the non-steak artifact region than the brightstreak artifact region whereas was increased 90.1% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental metal prostheses, $SUV_{mean}$ was reduced 18.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 18.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In patients with dental implant, $SUV_{mean}$ was increased 19.1% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 96.62% (p>0.05) in the non-steak artifact region than the dark streak artifact region. In phantom with dental implant, $SUV_{mean}$ was increased 14.4% (p<0.05) in the non-steak artifact region than the bright streak artifact region whereas was increased 7.0% (p>0.05) in the non-steak artifact region than the dark streak artifact region. Conclusion: When CT is used for attenuation correction in patients with dental metal prostheses, 19.1% reduced $SUV_{mean}$ is anticipated in the dark streak artifact region on CT images. The dark streak artifacts of CT by dental metal prostheses may cause false negative finding in PET/CT. We recommend that the non-attenuation corrected PET images also be evaluated for clinical use.

  • PDF

RADIOGRAPHIC EVALUATION OF THE PROXIMAL BONE LEVEL BETWEEN TWO IMPLANTS : A 3-YEAR COMPARATIVE STUDY BETWEEN BR$BR{\AA}$NEMARK AND ITI IMPLANTS IN THE MANDIBULAR POSTERIOR REGION (하악 구치부에 식립된 Br${\aa}$nemark 임프란트와 ITI 임프란트에서 임프란트간 치조정간골의 높이변화에 대한 방사선학적 비교)

  • Yi, Sang-Hwa;Cha, In-Ho;Shim, June-Sung;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.4
    • /
    • pp.458-470
    • /
    • 2004
  • Statement of problem: Br${\aa}$nemark or ITI are two currently most widely used implant systems but with contrasting design, surgical and restoration methods. Purpose: The purpose of this study was to compare changes and its statistical significance in bone height and shape which may rise due to the differences between two implant systems. Also to analyse the effect of inter-implant distance on annual bone height changes. Material & Method: Those patients who were treated with two or more of either Br${\aa}$nemark or ITI implants at posterior mandibular area at Yonsei University Dental Hospital, Implant Clinic were selected. At annual examination appointments, standardised radiographs using parallel technique were taken. Marginal bone and inter-implant crestal bone changes were measured and following results were obtained. Results: 1) When ITI and Br${\aa}$nemark system were compared, both annual marginal and inter-implant crestal bone height changes in ITI system in the first two years were smaller than Br${\aa}$nemark and they were statistically significant. On the third year, however, there was no statistical difference between two implant systems on their annual bone level changes (p>0.05). 2) The Marginal and inter-implant crestal bone changes were compared when inter-implant distance was less than 4mm. Statistically significant bone level changes were noted on the first year only for ITI implants but in the first and second year for Br${\aa}$nemark implants (p>0.05). 3) When comparing angulation changes between marginal bone and implant fixture, ITI system had smaller angulation changes but the annual changes were not statistically significant (p>0.05). Conclusion: Within the limitation of this study, it could be concluded that Br${\aa}$nemark implant systems had more changes in marginal and inter-implant crestal bone level in the first and second year after loading with statistical significance. Further studies are recommended to see the effects of these bone loss during the first and second year after loading on the long term prognosis of Br${\aa}$nemark Implants.

Implant and root supported overdentures - a literature review and some data on bone loss in edentulous jaws

  • Carlsson, Gunnar E.
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.4
    • /
    • pp.245-252
    • /
    • 2014
  • PURPOSE. To present a literature review on implant overdentures after a brief survey of bone loss after extraction of all teeth. MATERIALS AND METHODS. Papers on alveolar bone loss and implant overdentures have been studied for a narrative review. RESULTS. Bone loss of the alveolar process after tooth extraction occurs with great individual variation, impossible to predict at the time of extraction. The simplest way to prevent bone loss is to avoid extraction of all teeth. To keep a few teeth and use them or their roots for a tooth or root-supported overdenture substantially reduces bone loss. Jaws with implant-supported prostheses show less bone loss than jaws with conventional dentures. Mandibular 2-implant overdentures provide patients with better outcomes than do conventional dentures, regarding satisfaction, chewing ability and oral-health-related quality of life. There is no strong evidence for the superiority of one overdenture retention-system over the others regarding patient satisfaction, survival, peri-implant bone loss and relevant clinical factors. Mandibular single midline implant overdentures have shown promising results but long-term results are not yet available. For a maxillary overdenture 4 to 6 implants splinted with a bar provide high survival both for implants and overdenture. CONCLUSION. In edentulous mandibles, 2-implant overdentures provide excellent long-term success and survival, including patient satisfaction and improved oral functions. To further reduce the costs a single midline implant overdenture can be a promising option. In the maxilla, overdentures supported on 4 to 6 implants splinted with a bar have demonstrated good functional results.

THE EFFECT OF AUTOLOGOUS PLATELET-RICH PLASMA (PRP) ON BONE FORMATION AROUND DENTAL IMPLANT IN THE RABBIT: A HISTOMOR-PHOMETRIC AND REMOVAL TORQUE STUDY

  • Yi Yang-Jin;Yang Jae-Ho;Lee Sun-Hyung;Kim Yung-Soo;Kwon Sang-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.6
    • /
    • pp.659-681
    • /
    • 2001
  • Platelet-rich plasma(PRP) has been known to increase the rate and degree of bone formation by virtue of growth factors in concentrated platelets. Although its great healing effect on bone defect or pre-implantation site preparation in conjunction with bone substitute has been reported, the effect associated with implant is unknown. The purpose of this study was to investigate the effect of PRP on rapid osseointegration of endosseous dental implants in the rabbit tibiae. Twenty two adult female New Zealand white rabbits, weighing approximately 2.7-3.3kg, were used for this study. Twelve of the 22 animals were used for histomorphometric analysis and ten of the 22 were for removal torque test. Each animal received two implants in each tibia (two treated with PRP and two as control) and was given fluorochrome intramuscularly. For histomorphometric analysis, rabbits were divided into four groups according to the healing period. At 1 week, 2 weeks, 4 weeks and 8 weeks postoperatively, each three animals were sacrificed serially and the amount and rate of bone formation around dental implant were examined on the undecalcified sections under fluorescent microscope, polarized microscope and light microscope connected to a personal computer equipped with image analysis system. For removal torque test, rabbits were divided into two groups and removal torque tests were performed at 4 weeks, 10 weeks after implant placement. In total, 88 screw shaped, commercially pure titanium implants (Neoplant, Neobiotech, Seoul, Korea) were used in this study. Labeling pattern reflected differences of two groups in bone formation rate at each period. Histomorphometrically, PRP group showed significantly higher bone volume within threads compared to control group at 2 weeks ($70.30{\pm}4.96%$ vs. $50.68{\pm}6.33%$; P < .01) and 4 weeks ($82.59{\pm}5.94%$ vs. $72.94{\pm}4.57%$; P < .05 ). PRP group at 1, 2 and 4 weeks revealed similar degree of bone volume formation comparable to control group at 2, 4 and 8 weeks, respectively. On the other hand, while PRP group showed higher bone-implant contact ($47.37{\pm}8.09%$) than control group ($33.16{\pm}13.47%$) at 2 weeks, there were no significant differences between PRP group and control group for any experimental period. Removal torque values also showed no significant differences between PRP group and control group at any experimental period (P > .05). These findings imply that PRP could induce rapid, more bone formation around implant during early healing period and get faster secondary stability for reducing healing period, though it has not induced bone maturation enough to resist functional loading.

  • PDF

Influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with a lingual slot

  • Choi, Kyu-Hyung;Son, KeunBaDa;Lee, Du-Hyeong;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.5
    • /
    • pp.381-387
    • /
    • 2018
  • PURPOSE. Cement-retained implant prostheses can lack proper retrievability during repair, and residual cement can cause peri-implantitis. The purpose of this in vitro study was to evaluate the influence of abutment height and convergence angle on the retrievability of cement-retained implant prostheses with lingual slots, known as retrievable cement-type slots (RCS). MATERIALS AND METHODS. We fabricated six types of titanium abutments (10 of each type) with two different heights (4 mm and 6 mm), three different convergence angles ($8^{\circ}$, $10^{\circ}$, and $12^{\circ}$), a sloped shoulder margin (0.6 mm depth), a rectangular shape ($6mm{\times}6.5mm$) with rounded edges, and a rectangular ledge ($2mm{\times}1mm$) for the RCS. One monolithic zirconia crown was fabricated for each abutment using a dental computer-aided design/computer-aided manufacturing system. The abutments and crowns were permanently cemented together with dual-curing resin cement, followed by 24 hours in demineralized water at room temperature. Using a custom-made device with a slot driver and torque gauge, we recorded the torque ($N{\cdot}cm$) required to remove the crowns. Statistical analysis was conducted using multiple regression analysis and Mann-Whitney U tests (${\alpha}=.05$). RESULTS. Removal torques significantly decreased as convergence angles increased. Multiple regression analysis showed no significant interaction between the abutment height and the convergence angle (Durbin-Watson ratio: 2.186). CONCLUSION. Within the limitations of this in vitro study, we suggest that the retrievability of cement-retained implant prostheses with RCS can be maintained by adjusting the abutment height and convergence angle, even when they are permanently cemented together.

Maxillary cement retained implant supported fixed prosthesis using the millingable Pd-Ag alloy generated by CAD/CAM system: clinical report after two years in service (상악 전부 무치악 환자에서 CAD/CAM 시스템으로 제작되는 Pd-Ag 합금을 이용한 고정성 임플란트 전악 수복 증례)

  • Lee, Jun-Sik;Han, Se-Jin;Choi, Yu-Sung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.71-80
    • /
    • 2014
  • Full-mouth reconstruction of a patient using dental implants is a challenge if there is vertical and horizontal bone resorption. Therefore, it is should be cautious in making the fixed prostheses that restore the function and the esthetics of the gingiva and teeth. In full mouth rehabilitation, CAD/CAM system makes it possible to fabricate restorations with high precision, regardless of span of the restoration. Recently, Palladium-silver (Pd-Ag) alloy which is highly biocompatible and millingable has been developed to compensate for the shortcomings of the titanium or zirconia. This clinical report presents the reconstruction of a maxillary arch with a cement retained implant supported fixed prosthesis using a Pd-Ag alloy generated by CAD/CAM system on eleven osseointegrated implants. The occluding surfaces were made of Pd-Ag alloy, to decrease the risk of chipping or fracture. The prostheses were esthetically pleasing, and no clinical complications have been reported after two years.

A Telescopic System and Its Clinical Application for the Restoration of the Partially Edentulous Arch (부분 무치악 환자에서 텔레스코프 시스템을 적용한 전악 수복 증례)

  • Shin, Mee-Ran
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.2
    • /
    • pp.139-144
    • /
    • 2007
  • Prosthodontic treatment planning for various edentulous arches is not an easy issue for dentists. Especially, in case of removable partial denture, we must have a knowledge of overall treatment procedures, and a careful approach is needed. Recently, interest of dental implant and case reports are increasing, the decrease of the removable partial denture is true, but dental implantation takes longer treatment period and it is more expensive. Also, there are still some limitations like lack of available alveolar bone, patient's general condition, and chronic periodontitis. Therefore, sometimes implantation is impossible. Finally, implantation cannot be adapted to every single patient. Currently, the clasp type removable partial dentures are used routinely, giving patients many unesthetic and functional difficulties. With better laboratory technique, removable partial denture with attachment and removable partial denture in rigid type increase patient's happiness level much more than predicted. The case presented in this article, clinically demonstrate the efficiency of using a telescopic system to improve esthetic and functional recovery for patients who lose multiple teeth.

THE MANAGEMENT OF A COMPLEX IMPLANT CASE USING CAD-CAM TECHNOLOGY: A CLINICAL REPORT

  • Park, Eun-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.634-638
    • /
    • 2008
  • PURPOSE: The application of computer-aided technology to implant dentistry has created new opportunities for treatment planning, surgery and prosthodontic treatment, but the correct selection and combination of available methods may be challenging in times. Hence, the purpose of this case report is to present a combination of several computer-aided tools as approaches to manage complicated implant case. MATERIAL AND METHODS: A 47 year-old female patient with severe dental anxiety, high expectations, financial restrictions and poor compliance presented for a fixed rehabilitation. A CT scan with a radiographic template obtained with software (SimPlant, Materialize, Leuven, Belgium) was used for treatment planning. The surgical plan was created and converted into a stereolithographic model of the maxilla with bone-supported surgical templates (SurgiGuide, Materialise, Leuven, Belgium), that allowed for the precise placement of 7 implants in a severely resorbed edentulous maxilla. After successful osseointegration, an accurate scan model served as the basis for the fabrication of a one-piece milled titanium framework using the Procera (Nobel Biocare, Gothenburg, Sweden) technology. The final rehabilitation of the edentulous maxilla was rendered in the form of a screw-retained maxillary metal-reinforced resin-based complete prosthesis. RESULTS: Despite challenging circumstances, 7 implants could be placed without bone augmentation in a severely resorbed maxilla using the SimPlant software for pre-implant analysis and the SurgiGuide-system as the surgical template. The patient was successfully restored with a fixed full arch restoration, utilizing the Procera system for the fabrication of a milled titanium framework.

Sedation for Implant Surgery using Propofol and Remifentanil in Severe Dental Phobia Patient -A Case Report- (심한 치과공포증 환자에서 임플란트 식립을 위한 Propofol과 Remifentanil 진정법 -증례 보고-)

  • Lee, Jung-Hoo;Seo, Kwang-Suk;Shin, Teo-Jeon;Kim, Hyun-Jeong
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.10 no.2
    • /
    • pp.209-213
    • /
    • 2010
  • Anxiety and fear is two main factors that keep patients from going to dental clinic. Especially, patients may feel implants operations are more traumatic. Intravenous conscious sedation for dental treatment can make patient comfortable and relaxable. Midazolam is more popular for sedation for dental treatment, but target-controlled infusion (TCI) of propofol and remifentanil is gaining wide popularity. A 54-year-old female patient who had severe dental phobia was referred to our dental hospital. She had past history of 2 times of hyperventilation and syncope during dental treatment. The patient showed a lot of dental anxiety and fear to dental treatments and stress reduction protocol was needed. We administered intravenous conscious sedation using target controlled infusion system with remifentanil and propofol. During sedation, we monitored the status of consciousness with bispectral index and vital signs. Dental treatment could be finished successfully without any problems.

Dental infection control in clinical practice institutions experienced by dental hygiene students in the COVID-19 situation (코로나바이러스감염증-19 상황에서 임상실습 중 치위생(학)과 학생의 감염관리 인식과 치과의료기관의 감염관리 수행정도)

  • Son, Jung-hui;Jeong, Seo-young
    • Journal of Korean Academy of Dental Administration
    • /
    • v.9 no.1
    • /
    • pp.25-31
    • /
    • 2021
  • The aim of this study was to investigate the level of dental infection control experienced by dental hygiene students in clinical practice institutions to identify problems and improve infection control in dental institutions. This study conducted online surveys targeting 269 dental hygiene students from universities that conducted clinical practice to determine the students' level of awareness regarding dental infection control in dental institutions and the reality of infection control in dental institutions. The results showed that dental hygiene students recognized the need for infection control and education about infection control at a high level. However, only 47% of the students were accurately informed about COVID-19. Basic instruments, periodontal instruments, and implant surgical instruments were sterilized after use for each patient, mostly by the institution, but 3-way syringe tips, preservation instruments and prosthetic instruments were more frequently reused without sterilization immediately after use. For dental infection control to be practiced at dental institutions, it is necessary to establish a systematic and safe infection control system, including infection control education, designation of infection managers, and provision of infection control guidelines.