• Title/Summary/Keyword: Dental Implant

Search Result 2,744, Processing Time 0.025 seconds

Peri-implant bone length changes and survival rates of implants penetrating the sinus membrane at the posterior maxilla in patients with limited vertical bone height

  • Kim, Hae-Young;Yang, Jin-Yong;Chung, Bo-Yoon;Kim, Jeong Chan;Yeo, In-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.2
    • /
    • pp.58-63
    • /
    • 2013
  • Purpose: The aim of this study was to measure the peri-implant bone length surrounding implants that penetrate the sinus membrane at the posterior maxilla and to evaluate the survival rate of these implants. Methods: Treatment records and orthopantomographs of 39 patients were reviewed and analyzed. The patients had partial edentulism at the posterior maxilla and limited vertical bone height below the maxillary sinus. Implants were inserted into the posterior maxilla, penetrating the sinus membrane. Four months after implant insertion, provisional resin restorations were temporarily cemented to the abutments and used for one month. Then, a final impression was taken at the abutment level, and final cement-retained restorations were delivered with mutually protected occlusion. The complications from the implant surgery were examined, the number of failed implants was counted, and the survival rate was calculated. The periimplant bone lengths were measured using radiographs. The changes in initial and final peri-implant bone lengths were statistically analyzed. Results: Nasal bleeding occurred after implant surgery in three patients. No other complications were found. There were no failures of the investigated implants, resulting in a survival rate of 100%. Significantly more bone gain around the implants (estimated difference=-0.6 mm, P=0.025) occurred when the initial residual bone height was less than 5 mm compared to the >5 mm groups. No significant change in peri-implant bone length was detected when the initial residual bone height was 5 mm or larger. Conclusions: This study suggests that implants penetrating the sinus membrane at the posterior maxilla in patients with limited vertical bone height may be safe and functional.

Diagnostic efficacy of a modified low-dose acquisition protocol for the preoperative evaluation of mini-implant sites

  • Tadinada, Aditya;Marczak, Alana;Yadav, Sumit
    • Imaging Science in Dentistry
    • /
    • v.47 no.3
    • /
    • pp.141-147
    • /
    • 2017
  • Purpose: The objective of this study was to compare the outcomes of surgical mini-implant placement when potential mini-implant sites were scanned using a lower-dose $180^{\circ}$ acquisition protocol versus a conventional $360^{\circ}$ acquisition protocol. Materials and Methods: Ten dentate human skulls were used to provide sites for potential mini-implant placement. The sites were randomly divided into 2 groups: $360^{\circ}$ and $180^{\circ}$ cone-beam computed tomography (CBCT) acquisition protocols. A small-volume $180^{\circ}$ CBCT scan and a $360^{\circ}$ CBCT scan of each site were acquired using a Morita Accuitomo-170 CBCT machine and then a mini-implant was placed. A follow-up $360^{\circ}$ CBCT scan was done as a gold standard to evaluate the location of the mini-implant and root perforation. Two raters evaluated the scans. Results: Ninety-eight percent of the mini-implants placed did not perforate any root structure. Two percent of the sites had an appearance suggestive of perforation. On a Likert scale, both raters agreed that their subjective evaluation of the diagnostic quality of the protocols, ability to make and read measurements of the sites, and preferences for the specified diagnostic task were comparable. The Cohen kappa showed high inter-rater and intrarater agreement. Conclusion: In this ex vivo study, we found that the $180^{\circ}$ rotational acquisition was as effective as the conventional $360^{\circ}$ rotational acquisition for the preoperative evaluation of potential mini-implant sites.

Attachment systems for mandibular implant overdentures: a systematic review

  • Kim, Ha-Young;Lee, Jeong-Yol;Shin, Sang-Wan;Bryant, S. Ross
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.4
    • /
    • pp.197-203
    • /
    • 2012
  • PURPOSE. The aim of this systematic review was to address treatment outcome according to attachment systems for mandibular implant overdentures in terms of implant survival rate, prosthetic maintenance and complications, and patient satisfaction. MATERIALS AND METHODS. A systematic literature search was conducted using PubMed and hand searching of relevant journals considering inclusion and exclusion criteria. Clinical trial studies on mandibular implant overdentures until August, 2010 were selected if more than one type of overdenture attachment was reported. Twenty four studies from 1098 studies were finally included and the data on implant survival rate, prosthetic maintenance and complications, patient satisfaction were analyzed relative to attachment systems. RESULTS. Four studies presented implant survival rates (95.8 - 97.5% for bar, 96.2 - 100% for ball, 91.7% for magnet) according to attachment system. Ten other studies presented an implant survival rate ranging from 93.3% to 100% without respect to the attachment groups. Common prosthetic maintenance and complications were replacement of an assay for magnet attachments, and activation of a matrix or clip for ball or bar attachments. Prosthetic maintenance and complications most commonly occurred in the magnet groups. Conflicting findings were found on the rate of prosthetic maintenance and complications comparing ball and bar attachments. Most studies showed no significant differences in patient satisfaction depending upon attachment systems. CONCLUSION. The implant survival rate of mandibular overdentures seemed to be high regardless attachment systems. The prosthetic maintenance and complications may be influenced by attachment systems. However patient satisfaction may be independent of the attachment system.

Influence of zirconia and titanium fixture materials on stress distribution in abutment screws: a three-dimensional finite element analysis (지르코니아 및 티타늄 고정체 소재가 지대주 나사의 응력 분포에 미치는 영향: 3차원 유한 요소 분석)

  • Kim, Eun Young;Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.43 no.2
    • /
    • pp.42-47
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the stability of abutment screws used with the zirconia fixture-based implant system and compare them with those used with the existing titanium fixture system via the finite element method. Methods: A single implant-supported restoration was designed for the finite element analysis. A universal analysis program was used to set 8 occlusal points along the direction to the long axis of the implant, and an occlusal load of 700 N was applied. Results: In all models (Zir and Ti-fixture model), the screw threads presented with the highest von Mises stress (VMS) values, whereas the head and end presented with the lowest VMS values. The VMS of the screw used in the zirconia-fixture model was 5.97% lower than that used in the titanium-fixture model (261.258 vs. 276.911 MPa, respectively) despite statistical significance. Furthermore, the zirconia fixture (352.912 MPa) had a higher stress value (8.42%) than the titanium fixture (332.331 MPa). In a completely tightened titanium fixture implant system, the stress was concentrated in the implant-abutment connection interface, the zirconia fixture presented with a stable stress distribution. Conclusion: Although the zirconia fixture demonstrated a high VMS value, owing to the stiffness and elasticity coefficients of the material, the stress generated in the abutment screws was similar in all models. In conclusion, the zirconia fixture-based implant system presented with a more stable stress distribution in the abutment screws than the titanium fixture-based implant system.

Current trends in dental implants

  • Gaviria, Laura;Salcido, John Paul;Guda, Teja;Ong, Joo L.
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.2
    • /
    • pp.50-60
    • /
    • 2014
  • Tooth loss is very a very common problem; therefore, the use of dental implants is also a common practice. Although research on dental implant designs, materials and techniques has increased in the past few years and is expected to expand in the future, there is still a lot of work involved in the use of better biomaterials, implant design, surface modification and functionalization of surfaces to improve the long-term outcomes of the treatment. This paper provides a brief history and evolution of dental implants. It also describes the types of implants that have been developed, and the parameters that are presently used in the design of dental implants. Finally, it describes the trends that are employed to improve dental implant surfaces, and current technologies used for the analysis and design of the implants.

A Digitally Designed All-on-4 Restoration with Screwmentable Concept

  • Park, Koungjin;Han, Jung-Suk;Lee, Jae-Hyun
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.84-91
    • /
    • 2022
  • An all-on-4 restoration allows edentulous patients to use a fixed prosthesis with a minimum number of implants. These implant-supported fixed complete dentures have traditionally been fabricated as screw-retained or cement-retained prostheses. However, it is difficult to passively fit the long-span full-arch prosthesis using the screw-retained type restoration, and predictable retrievability is not obtained with the cement-retained type. This case report describes a prosthesis fabricated using a combination of the two retention types. The screwmentable method allows the implant-supported fixed complete denture to achieve a passive fit at the connection with retrievability. In addition, a framework with an optimized size was designed by using digital dental technology.

RETROSPECTIVE STUDY OF SINTERED POROUS-SURFACED DENTAL IMPLANTS IN RESTORING THE POSTERIOR MAXILLA (상악 구치부에 식립된 엔도포아 임플란트의 후향적 연구)

  • Kim, Sang-Soo;Ahn, Mi-Ra;Lee, Won-Hyuk;Jung, Heui-Seung;Shin, Im-Hee;Sohn, Dong-Seok
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.5
    • /
    • pp.361-366
    • /
    • 2009
  • Purpose: The purpose of this retrospective report was to analyze long-term survival rate of sintered porous-surfaced dental implant ($Endopore^{(R)}$ Dental Implant system, Innova Corporation, Toronto, ON, Canada). Methods: 61 partially edentulous patients were received a total of 127 Endopore dental implants in the maxilla. Of the 127 implants, 24 implants were restored with individual (ie, non-splinted) crowns, while 103 implants were splinted to other implants. Medical records and radiographs were evaluated and analyzed by the cumulative survival rate, location of implants, implants length and diameter, crown/implant ratio and whether the implant was splinted. Chi squire test was used statistically. Result: Of the 127 implants, 8 implants (6.3%) were removed and and cumulative survival rate was 93.7%. Conclusion: Endopore implants showed satisfactory results after up to 8 years function periods in the edentulous posterior maxilla.

A Comparative Study of Spiral Tomograms with Different Slice Thicknesses in Dental Implant Planning (인공치아 매식술 계획에 있어서 상이한 단층두께의 나선형 단층사진의 비교)

  • Yoon Suk-Ja
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.191-201
    • /
    • 1999
  • Purpose: To know whether there would be a difference among spiral tomograms of different slice thicknesses in the measurement of distances which are used for dental implant planning. Materials and Methods: 10 dry mandibules and 40 metal balls were used to take total 120 Scanorailll tomograms with the slice thickness of 2 mm, 4 mm and 8 mm. 3 oral radiologists interpreted each tomogram to measure the distances from the mandibular canal to the alveoalr crest and buccal. lingual and inferior borders of mandible. 3 observers recorded grades of 0, 1 or 2 to evaluate the perceptibility of alveolar crest and the superior border of mandibular canal. ANOVA with repeated measure. Chi-square tests and intrac!ass correlation coefficient(R₂, α) were used For statistical analysis. Results: There was not a statistically significant difference among spiral tomograms with different slice thicknesses in the measurement of the distances and in the perceptibility of alveolar crest and mandibular canal(p>0.05). All of them showed a good relationship in the reliability analysis. The perceptibility of alveolar crest and mandibular canal was almost similar and an excellent relationship was seen on all of them. Conclusions: There would be no significant difference. no matter which spiral tomogram of any slice thickness may be used in dental implant planning. considering the thickness of dental implant fixture.

  • PDF

Finite element analysis on the stress of supporting bone by diameters and lengths of dental implant fixture (유한요소법을 이용한 치과 임플란트 고정체의 직경과 길이에 따른 지지골의 응력 분석)

  • Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.151-156
    • /
    • 2016
  • Purpose: The dental implant should be enough to endure chewing load and it's required to have efficient design and use of implant to disperse the stress into bones properly. This study was to evaluate the stress distribution on a supporting bone by lengths and diameters of the implant fixture. Methods: The modeling and analysis of stress distribution was used for the simple molar porcelain crown model by Solidworks as FEM program. It was designed on applying with tightening torque of 20 Ncm of a abutment screw between a cement retained crown abutment and a fixture. The fixtures of experimental model used 10, 13mm by length and 4, 5mm by diameter. A external vertical loading on the two buccal cusps of crown and performed finite element analysis by 100 N. Results: The maximum von Mises stress(VMS) of all supporting bone models by fixture length and diameter were concentrated on the upper side of supporting compact bone. The maximum stress of each model under vertical load were 164.9 MPa of M410 model, and 141.2 MPa of M413 model, 54.3 MPa of M510 model, 53.6 MPa of M513 model. Conclusion: The stress reduction was increase of fixture's diameter than it's length. So it's effective to use the wider fixture as possible to the conditions of supporting bone.

Immediate implant placement for schizophrenic patient with outpatient general anesthesia

  • Nam, Hojin;Sung, Ki-Woong;Kim, Min Gyun;Lee, Kyungjin;Kwon, Dohyun;Chi, Seong In;Seo, Kwang-Suk
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.15 no.3
    • /
    • pp.147-151
    • /
    • 2015
  • The difficult oral healthcare in intellectually disabled patients with poor behavioral control has led to debate over the cost-effectiveness and validity of implant treatment in these patients. The patient in the present report had schizophrenia that had led to poor oral care and severe dental caries in the full mouth. Tooth extraction and a removable prosthesis were planned, but the guardian wanted an implant procedure. Since the guardian showed strong will and cooperation with regard to the patient's oral healthcare, extraction followed by immediate implant placement was performed across two rounds of general anesthesia. Since the outcome appears successful, we present this case report. Immediate implant placement after tooth extraction requires fewer surgeries and rounds of general anesthesia, reduces horizontal bone resorption, and can achieve better esthetic results. Therefore, as long as a certain degree of oral care is possible, this can be a positive option for restoration of a partially edentulous mouth, even in intellectually disabled patients.