• Title/Summary/Keyword: Density Test

Search Result 3,856, Processing Time 0.042 seconds

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Studies on the Effect of Low Temperature Treatment at Meiotic, Heading and Seedling Stage in Paddy Rice (수도의 장해형 냉해에 관한 연구)

  • Hong-Suk Lee;Hyung-Yull Cho;Pyeong-Ki Yim;Hoon Heu
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.15
    • /
    • pp.85-97
    • /
    • 1974
  • In order to clarify the inducing conditions and cause of sterility in rice plants, 4 varieties were cooled at 3 different levels of temperature combined with 3 different levels of treatment period. And 19 varieties were tested to examine the varietal difference of cold resistance. The results obtained were summarized as follows; 1. There were significant varietal differences in the effect of cooling treatment at meiotic stage. Suwon 213-1 was induced heavy sterility by 3 day cooling treatment at 17.5$^{\circ}C$ whereas Hayayuki, Nongpaik and Jinheung were induced a little sterility by 3 day cooling treatment at 15$^{\circ}C$ and 5 day treatment at 17.5$^{\circ}C$. The per cent of grain fertility was correlated significantly with the delayed days to heading, the degree of panicle extraction (Suwon 213-1, Nongpaik, Jinheung), culm length (Nongpaik, Suwon 213-1), and Auricle distance (Suwon 213-1). The degree of sterility was able to be estimated from the linear regression equation between the degree of panicle extraction (distance from panicle neck to flag leaf) and fertility percentage. In the case of heavy cold damage by the treatment of low temperature at meiotic stage, the rice plant had somewhat lower pollen density per anther, small and ununiform anther and pollen in size, and more sterile pollen grains. Suwon 213-1 showed anthesis in almost all spikelets, while Nongpaik, Jinheung and Hayayuki indicated considerable number of indehisced anther at 5 days after heading. 2. The fertility were not generally higher in cooling treatment at heading stage than at meiotic stage treatment. And significant correlation was found between the percentage of grain fertility treated at above two stages. Nongpaik and Jinheung were not affected in percentage of fertility by 5 day treatment at 15$^{\circ}C$ when these were treated at heading stage. Indehisced anthers were not found in Suwon 213-1 and Hayayuki, but Nongpaik and Jinheung showed more anthers which did not show anthesis 3. There was different varietal response to low temperature which was indicated by the decrease of grain fertility resulted from cooling treatment at meiotic stage. Jaekeun and Jinheung did not show low fertility but Milseong, Suwon 210, Satominoli and Suwon 213-1 showed outstanding decrease in fertility percentage by the cooling treatment at meiotic stage. The varieties which had low fertility were likely to have low pollen density per anther, abnormal anthers, small size po]]en grains and many sterile pollens. 4. Remarkable varietal difference of cold resistance was found in heading stage cooling treatment. Nongpaik, Jinheung, Jaekeun, Paltal, Akibare, Milseung and Palkeong were not affected in grain fertility by cooling treatments but Nonglimna No. 1, Suseong, Hayayuki, Suwon 213-1 and Suwon 210 showed significantly high sterility as treated by cool temperature. Most of the varieties showed higher fertility by cooling treatment at heading stage than meiotic stage but Hayayuki, Suseong and Nonglimna No.1 showed lower fertility when these were treated at heading stage than meiotic stage. There were two grops of varieties in the response to cooling treatment, one was somewhat non-anthesised and the other showed full anthesis. 5. In cold injury test of young seedlings, the result of observation was not accorded with the degree of growth inhibition. As a general, Palkeum and Suseong were highly torelant to cool temperature but Suwon 213-1, Jaekeun, Paltal, Shirogane, Palkeong, Mankyung were highly susceptible. 6. There is no significant correlation between the degree of young seedling cold damage and or the degree of growth retardation at seedling stage and grain fertility resulted from coding treatment both heading and meiotic stage.

  • PDF

The Standing Crops and Soil-borne Microfungal Flora of Phyllostachys reticulata in Korea (한국산(韓國産) 왕대나무의 현존량(現存量)과 토양(土壤) 미세균류상(微細菌類相))

  • Kim, Kwan-Soo
    • The Korean Journal of Mycology
    • /
    • v.7 no.2
    • /
    • pp.91-116
    • /
    • 1979
  • This paper is to investigate the standing crops and microfungal flora in soil in Phyllostachys reticulata forests in both the Yesan area (A) and the Kwangsan area (B). The stand density of the bamboo revealed 17,250 shoots per ha in area A, and in area B 14,780 shoots which were 16.1% less in number than area A. In respect to the environmental factors between the two areas, the mean temperature during the growth period was $1.5{\sim}2^{\circ}C$ higher in area B than in area A, soil tempeature also was $1{\sim}2^{\circ}C$ higher in area B, and the total quantities of nitrogen, phosphoric acid and organic compounds contained in the soil of area B were also slightly higher than those of area A. In area B the quantities of dried leaf matter, humus, and vegetation in the bamboo forest were also larger than in area A. In addition, five more species of microfungi which playa role in the decomposition of the various organic materials in the bamboo forests were identified in area B: Mortierella elongata, Mucor circinelloides, Aspergillus japonicus, Penicillium waksmani and Trichoderma lignorum. The atmospheric temperature in the inner portions of the bamboo forests was lower than the outside temperature, but the humidity was higher. The rates of relative illuminance were measured in area A at 4.19%, and in area B at 2.7%. These values revealed that the photosynthetic acitivity in the lower part of the bamboo was lost but it was considered that lower illuminance increased the microfungal activities in the vicinity of the surface soil. Since the productive structure of the bamboo showed that the maximum amount of photosynthesis was located in the upper portion of the bamboo in area B, it was considered to be an effective structure in maintaining the high productivity of the bamboo. The allometric relation between $D^2H$ and dry weight of stems(Ws), branches(Wb) and leaves(Wl) of the bamboo in area A were appoximated by log Ws=0.5262 log $D^2H$+1.9546; log Wb=0.6288 log $D^2H$+1.5723; log Wl=0.5181 log $D^2H$+1.8732, and those of the bamboo in area B were approximated by log Ws=0.5433 log $D^2H$+1.8610; log Wb=0.1630 log $D^2H$+2.3475; log Wl=0.4509 log $D^2H$+2.0041. From the above, the standing crops in area A were measured thus: Ws was 1,128. 83kg; Wb, 689.05kg; Wl, 926.69kg and Wl, 2,744.57kg per 10a. In area B, Ws was 1,206. 66kg; Wb, 679.92kg; Wl, 1,112.51kg and Wt, 2.999kg per l0a. Significant differences from the result of t-test were for $D^2H$ Ws, Wl and Wt between areas A and B. But no significant difference was found for Wb. In order to record as completely as possible the microfungal flora of the areas, every possible means was tried, and 158 strains of fungi were isolated, and of these, the microfungi of 55 species were identified. The dominant species were Trichoderma viride, Penicillium janthinellum, P. commune, Aspergillus oryzae, A. niger, A. gigantus, A. fumigatus, Mortierella ramaniana, var. anguliFPora, Mucor hiemalis and Zygorhynchus moelleri. According to the above results, it was revealed that optimum soil, the increases of soil materials, more species of soil microfungi, and the atmospheric temperature during the growth period have made the bamboo flourish and bring more species and larger quantities of vegetation in the bamboo forests. The correlation between the standing crops and environmental factors in the bamboo forest is considered to be a complicated relationship of all the factors, but the stand density is thought to be the most important factor involved.

  • PDF

The General Characteristics and Risk Factors Study According to Onset Time in Acute Stroke Patients (급성기 중풍환자의 발병시간에 따른 특성 및 위험인자 연구)

  • Kim, Mi-Young;Kim, Young-Jee;Lee, Seung-Yeop;Choi, Won-Woo;Leem, Jung-Tae;Kim, Chang-Hyun;Min, In-Kyu;Park, Sung-Week;Jung, Woo-Sang;Moon, Sang-Kwan;Park, Jung-Mi;Ko, Chang-Nam;Cho, Ki-Ho;Kim, Young-Suk;Bae, Hyung-Sup
    • The Journal of Internal Korean Medicine
    • /
    • v.29 no.4
    • /
    • pp.1011-1024
    • /
    • 2008
  • Objectives : The aim of this study was to assess the distribution of general characteristics and risk factors according to onset time in acute stroke patients. Methods : We studied hospitalized patients within 4 wks after the onset of stroke who were admitted to the Department of Internal Medicine at Kyunghee University Oriental Medical Hospital, Kyunghee University East-West Neo Medical Hospital, Kyungwon University Songpa Oriental Medical Hospital, Kyungwon University Incheon Oriental Medical Hospital, and Dongguk University Ilsan Oriental Medical Hospital from April 2007 to August 2008. The 24-hour day was divided into quartiles (6:00 to 12:00, 12:00 to 18:00, 18:00 to 24:00 and 24:00 to 6:00). We analyzed the general characteristics and risk factors according to onset time in acute stroke patients. Results : 468 subjects were included into the final analysis. 1. The most common time period for ischemic stroke onset was between 6:00 and 12:00. It demonstrated a 50% excess risk between 6:00 and 12:00. 2. On the demographic variables of the patients, the rate of hypertension was significantly higher from 18: 00 to 24: 00 than 24:00 to 6:00. 3. There was no significant difference of stroke type, Sasang constitution, or lifestyle between times. 4. According to the blood test, high density lipoprotein cholesterol was significantly higher at 24:00 to 6:00 and lower at 12:00 to 18:00 than other time-groups. 5. The patients diagnosed with metabolic syndrome were significantly more at 12:00 to 18:00 and fewer at 24:00 to 6:00. 6. Hypertension and coffee drinking showed close relationship with patients whose stroke occurred while awake in multivariate analysis. Conclusions : The above results showed that the overall tendency of acute stage cerebral infarction patients varied according to their onset time. These results can be utilized in the future as a basis material.

  • PDF

Development of a Solar Collector Performance of Cylindrical Parabolic Concentrating Solar Collector (태양열(太陽熱) 집열기개발(集熱器開發)에 관(關)한 연구(硏究) - 포물반사곡면(抛物反射曲面)으로된 2차원(二次元) 집광식(集光式) 태양열(太陽熱) 집열기(集熱器)의 성능분석(性能分析) -)

  • Song, Hyun Kap;Yon, Kwang Seok;Cho, Sung Chan
    • Journal of Biosystems Engineering
    • /
    • v.10 no.1
    • /
    • pp.54-68
    • /
    • 1985
  • It is desirable to collect the solar thermal energy at relatively high temperature in order to minimize the size of thermal storage system and to enlarge the scope of solar thermal energy utilization. So far the concentrating solar collector has been developed to collect solar thermal energy at relatively high temperature, but it has some difficulties in maintaining the volumetric body of solar collector for long term utilization. On the other hand, the flat-plate solar collector has been developed to collect the solar thermal energy at low temperature, and it has advantages in maintaining the system for long term utilization, since it's thickness is thin and not volumetric. In this study, to develop a solar collector that has both advantages of collecting solar thermal energy at high temperature and fixing conveniently the collector system for long term period, a cylindrical parabolic concentrating solar collector was designed, which has two rows of parabolic reflectors and thin thickness such as the flat-plate solar collector, maintaining the optical form of concentrating solar collector. The characteristics of the concentrating parabolic solar collector newly designed was analysed and the results are summarized as follows; 1. The temperature of the air enclosed in solar collector was all the same as $50^{\circ}C$ in both cases of the open and closed loop, and when the heat transfer fluid was not circulated in tubular absorber, the maximum surface temperature of the absorber was $118-120^{\circ}C$, this results suggested that the heat transfer fluid could be heated up to $118^{\circ}C$. 2. In case of longitudinal installation of the solar collector, the temperature difference of heat transfer fluid between inlet and outlet was $4^{\circ}-6^{\circ}C$ at the flow rate of $110-130{\ell}/hr$, and the collected solar energy per unit area of collector was $300-465W/m^2$. 3. The collected solar energy per unit area for 7 hours was 1960 Kcal/$m^2$ for the open loop and 220 Kcal/$m^2$ for the closed loop. Therefore it is necessary to combine the open and closed loop of solar collectors to improve the thermal efficiency of solar collector. 4. The thermal efficiency of the solar collector (C.P.C.S.C.) was proportional to the density of solar radiation, indicating the maximum thermal efficiency ${\eta}_{max}=58%$ with longitudinal installation and ${\eta}_{max}=45%$ with lateral installation. 5. The thermal efficiency of the solar collector (C.P.C.S.C.) was increased in accordance with the increase of flow rate of heat transfer fluid, presenting the flow rate of $110{\ell}/hr$ was the value of turning point of the increasing rate of the collector efficiency, therefore the flow rate of $110{\ell}/hr$ was considered as optimum value for the test of the solar collector (C.P.C.S.C.) performance when the heat transfer fluid is a liquid. 6. In both cases of longitudinal and lateral installation of the solar collector (C.P.C.S.C.), the thermal efficiency was decreased linearly with an increase in the value of the term ($T_m-T_a$)/Ic and the increasing rate of the thermal efficiency was not effected by the installation method of solar collector.

  • PDF

Study on Soluble Concentrate Formulation and Quality Control Techniques of a Microbial Insecticide "Bt-Plus" (미생물살충제 "비티플러스" 액상 제형화 및 품질 분석 기술에 관한 연구)

  • Eom, Seonghyeon;Park, Hyeonji;Kim, Kyusoon;Hong, Youkyeong;Park, Jiyeong;Choi, Bongki;Kim, Joonsung;Kim, Kunwoo;Kang, Moonsoo;Yang, Kyunghyung;Kim, Yonggyun
    • Korean journal of applied entomology
    • /
    • v.52 no.2
    • /
    • pp.115-123
    • /
    • 2013
  • A microbial insecticide "Bt-Plus" has been developed to enhance an insecticidal efficacy of an entomopathogenic bacterium, Bacillus thuringiensis (Bt). However, its wettable powder formulation is not preferred by farmers and industry producers due to relatively high cost. This study aimed to develop a soluble concentrate formulation of Bt-Plus. To this end, an optimal mixture ratio of two bacterial culture broths was determined to be 5:4 (v/v) of Bt and Xenorhabdus nematophila (Xn) along with 10% ethanol preservative. In addition, Bt broth was concentrated by 10 times to apply the mixture at 1,000 times fold dilution. The resulting liquid formulation was sprayed on cabbage crop field infested by late instar larvae of the diamondback moth, Plutella xylostella. The field assay showed about 77% control efficacy at 7 days after treatment, which was comparable to those of current commercial biopesticides targeting P. xylostella. For storage test in both low and room temperatures, the liquid formation showed a relatively stable control efficacy at least for a month. To develop a quality control technique to exhibit a stable control efficacy of Bt-Plus, Bt spore density ($5{\times}10^{11}$ spores/mL) and eight active component concentrations of Xn bacterial metabolites in the formulation products have been proposed in this study.

Environmental Equity Analysis of the Accessibility of Urban Neighborhood Parks in Daegu City (대구시 도시근린공원의 접근성에 따른 환경적 형평성 분석)

  • Seo, Hyun-Jin;Jun, Byong-Woon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.14 no.4
    • /
    • pp.221-237
    • /
    • 2011
  • This study aims to investigate the environmental equity of the accessibility to urban neighborhood parks in the city of Daegu. The spatial distribution of urban neighborhood parks was explored by spatial statistics and the spatial accessibility to them was then evaluated by both minimum distance and coverage approaches. Descriptive and inferential statistics such as proximity ratio, Mann Whitney U test, and logistic regression were used for comparing the socioeconomic characteristics over different accessibilities to the neighborhood parks and then testing the distributional inequity hypothesis. The results from the minimum distance method indicated that Dalseo-gu had the best accessibility to the neighborhood parks while Dong-gu had the worst accessibility. It was apparent with the coverage method that Dalseo-gu had the best accessibility whereas Dong-gu and Nam-gu had the worst accessibility to the neighborhood parks at 500m and 1,000m buffer distances. There existed the spatial pattern of environmental inequity in old towns with respect to population density and the percentage of people under the age of 18. The spatial pattern of environmental inequity in new towns was explored on the basis of the percentage of people over the age of 65, the percentage of people below the poverty level, and the percentage of free of charge rental housing. These results were closely related to the development process of urban parks in Daegu stimulated by the quantitative urban park policy, urban development process, and residential location pattern such as permanent rental housing and free of charge rental housing. This study further extends the existing research topics of environmental justice related to the distributional inequity of environmental disamenities and hazards by focusing on environmental amenities such as urban neighborhood parks. The results from this study can be used in making the decisions for urban park management and setting up urban park policy with considering the social geography of Daegu.

Experimental Study for Confirmation of Relaxation Zone in the Underground Cavity Expansion (지중 내 공동 확장에 따른 이완영역 확인을 위한 실험적 연구)

  • Kim, Youngho;Kim, Hoyeon;Kim, Yeonsam;You, Seung-Kyong;Han, Jung-Geun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.4
    • /
    • pp.231-240
    • /
    • 2017
  • Recently, there have been frequent occurrences of ground sink in the urban area, which have resulted in human and material damage and are accompanied by economic losses. This is caused by artificial factors such as soil loss, poor compaction, horizontal excavation due to the breakage of the aged sewage pipe, and lack of water proof at vertical excavation. The ground sink can be prevented by preliminary restoration and reinforcement through exploration, but it can be considered that it is not suitable for urgent restoration by the existing method. In this study, a model experiment was carried out to simulate the in-ground cavities caused by groundwater flow for developing non-excavation urgent restoration in underground cavity and the range of the relaxation zone was estimated by detecting the around the cavity using a relaxation zone detector. In addition, disturbance region and relaxation region were separated by injecting gypsum into cavity formed in simulated ground. The shape of the underground cavity due to the groundwater flow was similar to that of the failure mode III formed in the dense relative density ground due to water pipe breakage in the previous study. It was confirmed that the relaxed region detected using the relaxation zone detector is formed in an arch shape in the cavity top. The length ratio of the relaxation region to the disturbance region in the upper part of the cavity center is 2: 1, and it can be distinguished by the difference in the decrease of the shear resistance against the external force. In other words, it was confirmed that the secondary damage should not occur in consideration of the expandability of the material used as the injecting material in the pre-repair and reinforcement, and various ground deformation states will be additionally performed through additional experiments.

Quality characteristics of muffins added with Pholiota adiposa powder (검은비늘버섯 분말을 첨가한 머핀의 품질특성)

  • Noh, Jae-Gwan;Yoon, Hyang-Sik;Oh, Eun Young;Kim, Ji Won;Kim, Sang Hee;Kim, Yee Gi;Han, Nam Soo;Eom, Hyun-Ju
    • Food Science and Preservation
    • /
    • v.21 no.6
    • /
    • pp.815-823
    • /
    • 2014
  • This study was carried out to investigate the quality characteristics of muffins with added Pholiota adiposa powder. Muffins were prepared with different amounts of Pholiota adiposa powder (in 0, 2.5, 5, 10, and 15% ratios to the flour quantity). For analyzing the quality characteristics during the manufacturing of muffins, the pH, moisture content, dough density, height, specific volume, baking loss, texture, color, antioxidant activity, total polyphenol content, and sensory test results were determined. As the Pholiota adiposa powder content increased, the moisture content of the muffins decreased from 26.72 to 22.56%. The hardness of the muffins was increased with increasing Pholiota adiposa powder content, with the muffins with 15% Pholiota adiposa powder the hardest among all the samples. The inner color of the muffins, particularly the L and b values, decreased with increasing powder content compared to those of the control, but the a value increased. As the Pholiota adiposa powder content increased, the antioxidant activity and total polyphenol content of the muffins also increased. In the sensory evaluation, the muffins with 5% Pholiota adiposa powder showed higher values than the control and the other samples in all aspects, showing that 5% Pholiota adiposa powder could be incorporated into muffins to meet the taste and functional needs of the consumers.

Elimination of Lily Symptomless Virus by In Vitro Scaling and Reinfection Rates under Various Culture Conditions in Korean Native Lilies (한국 자생나리의 기내 인편삽에 의한 Lily Symptomless Virus 제거 및 구근 재배조건에 따른 재감염 분석)

  • Kim, Min Hui;Park, In Sook;Park, Kyeung Il;Oh, Wook;Kim, Kiu Weon
    • Horticultural Science & Technology
    • /
    • v.33 no.6
    • /
    • pp.891-899
    • /
    • 2015
  • The lily symptomless virus (LSV) is the most common virus in Korean native lilies and causes various types of damage to overall plant growth. This study was carried out to investigate the elimination rate of the LSV by the in vitro scale culture (scaling) method in Korean native lilies and to test reinfection rates of the LSV under several field culture conditions of bulb production. Four Korean native lilies (Lilium dauricum, L. distichum, L. lancifolium, and L. maximowitzii) were used and their scales were cultured in vitro for micro-scale formation. The micro-scales were subcultured repeatedly using MS culture medium supplemented with 30 or $90g{\cdot}L^{-1}$ sucrose. The culture conditions were $24{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ PPFD with 16 hour daylength using fluorescent lamps and maintained at $22{\pm}2^{\circ}C$. The virus-free bulblets were grown for one to three years in the greenhouse and transplanted to the field in October or March. Virus infection rates were investigated by direct tissue blotting immunobinding assays and measurement of chlorophyll and protein contents. Virus-free plants could be obtained from the 5th subculture of micro-scales in L. lancifolium and L. maximowitzii or from primary culture in L. dauricum and L. distichum. LSV-free plants were reinfected during bulb production in the field. Reinfection rates were higher at older bulb ages and under higher planting density. The plants planted in October and at inland Gyeongsan had higher infection rates than those planted in March and at coastal area Pohang. The reinfection rate of L. maximowitzii was higher than those of L. dauricum and L. lancifolium. The LSV-infected plants had lower chlorophyll contents and unchanged protein contents compared to virus-free plants.