• 제목/요약/키워드: Densitometry

검색결과 120건 처리시간 0.017초

골밀도 검사 후 치료지시 이행정도에 영향을 미치는 요인 (The Influencing Factors of the Compliance Level with Therapeutic Regimen after the Bone Mineral Densitometry)

  • 유영원;이은남
    • 대한간호학회지
    • /
    • 제34권1호
    • /
    • pp.63-71
    • /
    • 2004
  • Purpose: This study was to identify the influencing factors of the compliance level to a therapeutic regimen after a bone mineral densitometry test. Method: The sample for the study was 95 people who took the bone mineral densitometry test from March, 2002 to July, 2002. Data was collected by mail using aself reporting questionnaire on the selected variables such as the compliance level, self efficacy, health locus of control, susceptibility, severity, usefulness, barrier, and self esteem. Results: The average compliance level was 63.93. Through multiple regression, three independent variables including chance health locus of control on personality, the result of bone mineral density and self-efficacy were entered in the model as the significant determinants of the compliance level after a bone mineral densitometry test. The coefficients of determination of each variable were 10.9%, 8.3% and 8.1% respectively. Conclusion: The identification of the determinants of the compliance level to the therapeutic regimen after bone mineral densitometry is expected to contribute to the development of an intervention program to improve the compliance level to the therapeutic regimen in osteoporosis patients.

E.coli ATCC 21990이 생산하는 Aminoglycoside-3'-Phosphotransferase(APH(3')) 의 Densitometric TLC Assay (Densitometric TLC Assay of Aminoglycoside-3'-Phosphotransferase (APH(3')) Produced by E. coli ATCC 21990)

  • 이정환;김계원;김기태;나규흠;김학주;양주익;김수일
    • 한국미생물·생명공학회지
    • /
    • 제19권4호
    • /
    • pp.372-379
    • /
    • 1991
  • E.coli ATCC 21990의 aminoglycoside-3'-phosphotransferase(APH(3'))의 신속하고 간편한 정량적 방법을 TLC densitometry를 이용하여 확립하였다. APH(3') 반응생산물인 3' 위치에 인산화된 kanamycin B(3'PKMB)는 silica gel plate에서 cnloroform-methanol-method-ammonia water (3:4:3) 전개용매로 반응물에서 분리되었고, 3'PKMB의 양은 ninhydrin으로 발색 후 densitometry로 측정하였다. APH(3')의 densitometric TLC assay는 좋은 정량적 결과와 재현성을 보였고, 3'-PKMB에 대한 감도는 1.56nmol이었으며 많은 시료의 분석이 한번의 실시로 가능하였다. 이 방법은 aminoglycoside 항생제의 불활화 효소 분석에 응용이 가능하리라 여겨진다.

  • PDF

Development of Computerized Densitometry for the Quantitative Analysis of Diffuse Retinal Nerve Fiber Layer Atrophy

  • 이재성;박광석;이가영;김동명
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.146-149
    • /
    • 1997
  • Computerized densitometry was developed or the quantitative measurement of diffuse retinal nerve fiber layer (RNFL) atrophy and intra- and inter-operator reliability and clinical validity of this system were evaluated. Vertical diameter, center of the optic disc, and peripapillary circles which had radii of 1.5 and 2.5 times that of the optic disc were user-interactively determined in digitized RNFL photograph and density profile along each circle was measured and normalized. The areas under the normalized density profiles of the superior and the inferior segments in both circle were used or the study of RNFL. To determine the variability and correspondence in the measurements of density variations, 21 RNFL photographs of glaucoma patients which showed varying degrees of atrophy underwent computerized densitometry by two operators on two separate occasions. Coefficient of variation in the densitometric measurements was $1.2{\sim}5.4%$. Intra- and inter-operator reliabilities were excellent. The correlations between the densitometric values and mean deviations of Humphrey C30-2 visual field showed statistical significance. Computerized densitometry of RNFL photographs was useful in the objective and quantitative assessment of diffuse RNFL atrophy.

  • PDF

방사선조사가 골무기질함량에 미치는 영양에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE CHANGE OF BONE MINERAL METABOLISM AFTER IRRADIATION)

  • 진해윤;이상래
    • 치과방사선
    • /
    • 제18권1호
    • /
    • pp.53-66
    • /
    • 1988
  • Irradiation is widely used for the treatment of malignant diseases, and possibly cause the osteoporosis. The bone densitometry and bone scintigraphy are valuable when used to monitor the patients longitudinally to access the progression of osteoporosis and risk of osteoradionecrosis. To evaluate the osteoporosis after irradiation of cobalt-60 gamma ray on the lumbar spines of New Zealand white rabbits, bone densitometry by dual photon absortiometry and bone scintigraphy were performed weekly. The decrease of bone density began at the first week after irradiation, and were in the nadir at 4-6th week. The osteoblastic activity measured by bone scintigraphy decreased in the first week, and was in the nadir at 4-6th week. The severity of these changes were related to the radiation dose. In conclusion, the osteoporosis before presentation of the osteoradionecrosis can be developed at low dose irradiation and confirmed by bone densitometry, bone scanning, and histopathology.

  • PDF

골밀도 측정의 올바른 임상 적용 (Clinical Application of Bone Mineral Density Measurement)

  • 김덕윤
    • 대한핵의학회지
    • /
    • 제38권4호
    • /
    • pp.275-281
    • /
    • 2004
  • Compared with the earlier technique of dual photon absorptiometry (DPA) using $^{153}Gd$ radionuclide source, dual energy X-ray absorptiometry (DXA) has advantages of higher precision, accuracy and shorter scanning time. Despite the change from DPA to DPX, the nuclear medicine physicians has remained one of major suplier of this service due to long-standing use of DPA. Among many kinds of bone densitometries, DXA is the "gold standard" for the noninvasive diagnosis of osteoporosis. Especially there is no role for peripheral devices in the monitoring of patients on therapy. But, there are some areas of controversy related to the application of DXA, such as proper site of measurement, accurate interpritation, appropriate use of T-score, and the reference population young database. And the accuracy, precision, and quality control issues relating to bone density measurement are important subjects. To address these issues, the International Society for Clinical Densitometry (ISCD) has convened two Position Development Conferences and addressed official positions. This review deals the key elements of ISCD position paper and other important issues on the management of bone densitometry.

Femoral Metastasis in Bone Mineral Densitometry

  • Han-Kyung Seo;Do-Cheol Choi;Cheol-Min Shim;Jin-Hyeong Jo
    • 핵의학기술
    • /
    • 제27권1호
    • /
    • pp.7-8
    • /
    • 2023
  • A 50-year-old female patient referred by the department of breast and thyroid surgery was recommended for orthopedic surgery because lesion like herniation pit was found in the left proximal femur in bone mineral densitometry (BMD). She was later diagnosed with bone metastasis on biopsy in orthopedic surgery. Pelvic X-ray and Lt thigh MRI were performed . Intra-medually nail was operated later. The BMD is a diagnostic method that determines the results by numerical values, so it is inevitable to neglect to observe the bone shape, but as shown in the above case, the examiner's observation of changes in bone shape can return to beneficial treatment for patients.

  • PDF

Femoral Cystic Lesion in Bone Mineral Densitometry

  • Han-Kyung Seo;Do-Cheol Choi;Cheol-Min Shim;Jin-Hyeong Jo
    • 핵의학기술
    • /
    • 제27권1호
    • /
    • pp.9-10
    • /
    • 2023
  • A 78-year-old female patient referred by the department of obstetrics and gynecology was recommended for orthopedic surgery because a cystic lesion was found in the left femoral proximal area in the bone mineral densitometry. CT scan and general X-ray performed in the orthopedic department found benign tumors later. Intra-medullary nail was operated. Curettage and bone graft were performed. Radiotechnologist is also important for the morphological observation of femur in the femoral BMD. It provides a lot of benefits to the patient.

  • PDF

Femoral Mass in Bone Mineral Densitometry

  • Han-Kyung Seo;Do-Cheol Choi;Cheol-Min Shim;Jin-Hyeong Jo
    • 핵의학기술
    • /
    • 제27권2호
    • /
    • pp.81-82
    • /
    • 2023
  • A 55-year-old female patient, referred by the endocrine metabolism department, was recommended for orthopedic surgery because a lesion was found in the proximal femur in the bone mineral densitometry (BMD). Pelvis AP and frog-leg images performed by the orthopedic department found an intraosseous mass (more likely a benign tumor) in the greater trochanter of the left femur. However, she did not need special treatment and decided to keep observing. The role of a radiologic technologist is important in BMD and it provides significant assistance in the treatment of patients.

디스플레이 장치에서 인쇄원고의 컬러 재현특성에 관한 연구 (A Study on the Color Reproduction Characteristic of Original Copy in Display Device)

  • 조가람;구철회
    • 한국인쇄학회지
    • /
    • 제23권1호
    • /
    • pp.65-75
    • /
    • 2005
  • An accurate characterization of the display device is essential for better color matching. The calibration and characterization process in display device is needed to transform the device dependent color to the device independent color. The process of characterization performs a linearization and transforms the linearized values into the CIE XYZ tristimulus values. The purposes of this paper is to propose optimal color transformation method for accurate reproduction of original copy in display device and to explain the propriety of transformation method using specific variable for the power of gradation expression.

  • PDF

Penicillium islandicum에 의한 황변미독(黃變米毒) Luteoskyrin의 생성(生成) (Formation of Luteoskyrin by Penicillium islandicum)

  • 김용화;이서래
    • 한국식품과학회지
    • /
    • 제10권1호
    • /
    • pp.46-51
    • /
    • 1978
  • 황변미독(黃變米毒)의 일종인 luteoskyrin의 동정(同定) 및 정량법(定量法)을 검토한 후 변질미에서 분리된 Pen. islandicum의 luteoskyrin 생성능(生成能)을 추구한 결과는 다음과 같다. 1) Luteoskyrin은 0.5 N oxalic acid impregnated silicagel G plate로서 acetone : n-hexane : water(6:3:1.5, upper layer)를 전개용매로하는 TLC방법에서 분리(分離)가 가장 좋았다. 분리된 황색물질의 최대흡수파장(吸收波長)은 426, 448nm이었으며 chromatogram을 태양광선에 $2{\sim}3$시간 노출시 자색(紫色)으로 변하였다. 2) Luteoskyrin의 정량법으로서 TLC전개(展開)후 용출비색법(溶出比色法)에서는 4 ppm, densitometry에서는 0.1 ppm이 검출한계(檢出限界)이었다. 미곡 중의 허용량(許容量)을 3.68 ppm이하로 정설할 경우 곡류시료 중 luteoskyrin의 검색(檢索)에는 densitometry가 적합할 것이다. 3) Pen. islandicum에 의한 luteoskyrin 생성능은 Czapek 액체배지에서는 균계체(菌系體) 1g당 11mg, 가압살균한 쌀에서는 1g당 40mg이었다.

  • PDF