• 제목/요약/키워드: Delta3D$^{TM}$

검색결과 14건 처리시간 0.024초

Quantitative light-induced fluorescence-D를 이용한 탈회 법랑질의 재석회화 감시 (MONITORING OF REMINERALIZATION OF DECALCIFIED ENAMEL USING QUANTITATIVE LIGHT-INDUCED FLUORESCENCE-D)

  • 류연숙;김종수
    • 대한소아치과학회지
    • /
    • 제39권3호
    • /
    • pp.257-266
    • /
    • 2012
  • 인공 우식 용액으로 72개의 건전한 치아에 백색 병소를 형성을 유도하고 $CavityShield^{TM}$(Group I), $FluroDose^{TM}$(Group II) 그리고 $Flor-Opal^{(R)}$ Varnish(Group III)를 2주 간격으로 1, 2, 3회 도포하였다. 마지막 불소 바니쉬 도포 2주 후 QLF-D 영상을 촬영하여 광도 변화량(${\Delta}L$)을 측정하였고, 편광 현미경으로 법랑질 탈회 깊이 변화량(${\Delta}D$)을 측정하여 통계적으로 비교하였다. 1. Group I, II, III에서 QLF-D로 관찰한 결과, 1회 도포군보다 2주 간격으로 2, 3회 도포군에서 유의하게 ${\Delta}L$ 값이 증가하였고, 각 불소 바니쉬에서 도포 횟수에 따라 회귀 분석 결과, y = 3.878x + 90.612, y = 3.133x + 37.168, y = 3.509x + 82.322의 회귀 방정식이 산출되었다(p < 0.05). 2. Group I, II, III에서 편광 현미경으로 관찰한 결과, 1회 도포군보다 2주 간격으로 2, 3회 도포군에서 유의하게 ${\Delta}D$ 값이 감소하였고, 각 불소 바니쉬에서 도포 횟수에 따라 회귀 분석 결과, y = -2.336x + 107.235, y = -2.158x + 101.620, y = -1.940x + 94.806의 회귀 방정식이 산출되었다(p < 0.05). 3. 불소 바니쉬 적용하고 편광 현미경으로 관찰한 인공 우식의 깊이 변화량과 QLF-D로 관찰한 광도 변화량 사이의 피어슨 상관 계수는 Group I에서 -0.673, Group II에서 -0.574, 그리고 Group III에서 -0.431이었다(p < 0.05).

편광 비의존성 GaInAs/GaInAsP/InP 반도체 광 증폭기 구조에 관한 연구 (A Study on the Structure of Polarization Independent GaInAs/GaInAsP/InP Semiconductor Optical Amplifier)

  • 박윤호;강병권;이석;조용상;김정호;황상구;홍창희
    • 한국정보통신학회논문지
    • /
    • 제3권3호
    • /
    • pp.681-686
    • /
    • 1999
  • 본 논문에서는 편광 비의존 특성을 가지는 반도체 광 증폭기 개발을 위해 지금까지와는 다른 새로운 방법인 160($\AA$) 두께를 가지는 GaInAs 양자 우물에 GaAs Delta 층을 각각 1층, 2층, 3층을 삽입한 구조와 GaAs Delta 3층의 구조에서 Delta 층의 두께를 1 원자층에서 3 원자층까지 변화시켜 계산한 결과, 1 원자층 두께를 가지는 GaAs Delta 층이 3층 포함된 구조에서 3dB 이득 대역폭이 TE, TM 모두 85nm로 매우 넓은 대역폭과 편광 비의존 특성을 함께 가지는 구조를 얻어낼 수 있었다. 이러한 GaInAs 양자 우물에 GaAs Delta 층을 삽입한 구조의 이론적 이득 특성의 결과는 반도체 광 증폭기의 설계에 있어서 아주 중요하며, 또한 광대역 과장 분할 다중화 시스템에 적용될 수 있는 반도체 광 증폭기에 알맞은 구조로 사용될 수 있다.

  • PDF

소규모 교전에서의 적시 대응 시나리오 개발 방안 연구 (Development of Timely Counter-scenario on Small Scale Engagements)

  • 안의국;장대순;변재정;권용진;박상철
    • 한국시뮬레이션학회논문지
    • /
    • 제22권2호
    • /
    • pp.63-71
    • /
    • 2013
  • 미래의 무기체계 개발은 점점 복잡해지고, 많은 비용이 소요된다. 무기체계 개발을 위해 M&S(Modeling & simulation)기술을 사용하는 것에 대한 관심이 점점 높아지고 있다. M&S기술은 훈련, 전략 수립, 교전수칙, 무기체계 획득 등을 하는데 활용된다. 본 논문에서는 교전급 모델의 운용을 위해 소규모 교전 시나리오 생성 방안을 제시 한다. 생성된 시나리오는 지휘관의 훈련, 체계 운용 분석, 전술 검증을 위해 사용된다. 이 연구에서는 FSA(Finite State Automata)이론과 DFS(Depth First Search)알고리즘을 이용해 시나리오를 생성하는 방법론을 제시하였다. 그리고 제안된 방법론을 이용해 공격함과 정찰함이 교전하는 소규모 교전 시나리오 예제에 적용하였으며 이를 Delta3D$^{TM}$로 가시화 하였다.

2종의 측색기에 의한 도재 색조 재현의 정확성 비교 (Comparison on accuracy of porcelain color reproducibility using two colorimeters)

  • 이태일;안진수;김영수;신상완
    • 대한치과보철학회지
    • /
    • 제47권3호
    • /
    • pp.348-355
    • /
    • 2009
  • 연구 목적: ShadeEye-Ncc dental chroma meter (Shofu Inc., Kyoto, Japan)와 Shadepilot$^{TM}$ system (Degudent Inc., Hanau, Germany)의 도재색조 재현의 정확성을 비교연구하여 보고자 함이다. 연구 재료 및 방법: ShadeEye-Ncc dental chroma meter와 Shadepilot$^{TM}$ system을 사용하여 Vitapan 3D Master shade guide의 2M2와 3M2 shade tap.을 측색하고, 이 자료를 통하여 shade guide tap. 형태로 도재시편을 제작한다. 시편제작 시 사용하는 porcelain system은 ShadeEye-Ncc dental chroma meter는 Vintage Halo Porcelain system을, Shadepilot$^{TM}$ system은 VitaOmega900 Porcelain system을 사용한다. 모델인 shade tap.과 제작된 도재시편을 spectrophotometer로 측색하고, 그 결과를 토대로하여 ${\Delta}E$를 계산하여, 두 측색기의 정확성을 비교검증하였다. 결과: 1. Shadepilot$^{TM}$ system이 ShadeEye-Ncc dental chroma meter에 비하여 더 적합한 도재색조 재현성을 나타내었다 (P <.05). 2. 모델인 Shade tap.의 shade에 따라서 도재색조 재현성에 차이를 나타내었다. 2M2 shade tap.에 비하여 3M2 shade tap.에서 더 적합한 도재색조 재현성을 나타내었다 (P <.05). 3. 두 측색기 모두에서 제작된 도재시편의 ${\Delta}E$가 평균4.44-6.14로 육안으로 구분 가능한 정도의 색조차이를 보였다. 결론: Shadepilot$^{TM}$ system이 비교적 더 정확한 도재색조 재현성을 나타낸다고 할 수 있으며, ShadeEye-Ncc dental chroma meter를 사용할 때는 치아 전체의 여러부분에서 측색을 하여 정확성을 높이는 것이 필요하리라 생각된다.

수종 도재 색조 선택 시스템의 spectrophotometer를 이용한 색조 재현성 평가 (THE REPRODUCIBILITY OF VARIOUS PORCELAIN COLOR SELECTION SYSTEMS USING SPECTROPHOTOMETRY)

  • 김이경;조인호;신수연
    • 대한치과보철학회지
    • /
    • 제42권5호
    • /
    • pp.544-555
    • /
    • 2004
  • Statement of problem: Shade selection has traditionally been accomplished by visual examination, which is particularly relevant to the shade selection of anterior teeth, but the subjective nature of visual analysis can lead to errors in shade matching. Recently shade selection systems have been developed to provide a more objective and scientific approach to understanding and clarifying shade selection. Purpose : The purpose of this study was analysis of various shade analyzing equipment with the goal of providing a more objective shade selection. Materials and method: Visual shade matching system selection(Vita Lumin Vacuum shade guide, Vitapan 3D Master shade guide) and mechanical shade matching method($ShadeEye^{(R)}$-EX Chroma Meter, $Shadescan^{TM}$ System) used for this study. The shade guide tap specimens for 10 extracted maxillary anterior teeth were produced by selecting shades using each shade matching system. The accuracy of the selection of shades for the teeth and fabricated specimens were evaluated by analyzing the calculated shade difference(${\Delta}E^*$), using a spectrophotometer and calculating the output of value $L^*,\;a^*,\;b^*$. Results and conclusion: The results show that the average ${\{Delta}E^*$ value (difference of shade) of the shade tap specimens to the actual specimen decreased in the following order: Vita Lumin Vacuum Shade Guide(VL), $ShadeEye^{(R)}$-EX Chroma Meter(SE) Vitapan 3D Master Shade guide(V3), and $Shadescan^{TM}$ System(55) : and that there are significant statistical differences between the VL and SS (p<0.05). In the analysis of the ${\Delta}E^*$ (difference of shade) value,40% of the VL group was found to be less than 3.3 (limit value of shade tap specimens clinically acceptable), 60% in the V3 group, 50% in the SE group, and 80% in the SS group.

Radiologic Assessment of Subsidence in Stand-Alone Cervical Polyetheretherketone (PEEK) Cage

  • Ha, Sung-Kon;Park, Jung-Yul;Kim, Se-Hoon;Lim, Dong-Jun;Kim, Sang-Dae;Lee, Sang-Kook
    • Journal of Korean Neurosurgical Society
    • /
    • 제44권6호
    • /
    • pp.370-374
    • /
    • 2008
  • Objective : Aim of study was to find a proper method for assessing subsidence using a radiologic measurement following anterior cervical discectomy and fusion (ACDF) with stand-alone polyetheretherketone (PEEK), $Solis^{TM}$ cage. Methods : Forty-two patients who underwent ACDF with $Solis^{TM}$ cage were selected. With a minimum follow-up of 6 months, the retrospective investigation was conducted for 37 levels in 32 patients. Mean follow-up period was 18.9 months. Total intervertebral height (TIH) of two fused vertebral bodies was measured on digital radiographs with built-in software. Degree of subsidence (${\Delta}TIH$) was reflected by the difference between the immediate postoperative and follow-up TIH. Change of postoperative disc space height (CT-MR ${\Delta}TIH$) was reflected by the difference between TIH of the preoperative mid-sagittal 2D CT and that of the preoperative mid-sagittal T1-weighted MRI. Results : Compared to preoperative findings, postoperative disc height was increased in all cases and subsidence was observed only in 3 cases. For comparison of subsidence and non-subsidence group, TIH and CT-MR ${\Delta}TIH$ of each group were analyzed. There was no statistically significant difference in TIH and CT-MR ${\Delta}TIH$ between each group at 4 and 8 weeks, but a difference was observed at the last follow-up TIH (p=0.0497). Conclusion : ACDF with $Solis^{TM}$ cage was associated with relatively good radiologic long-term results. Fusion was achieved in 94.5% and subsidence occurred in 8.1% by the radiologic assessment. Statistical analysis reveals that the subsidence seen later than 8 weeks after surgery and the development of subsidence does not correlate statistically with the change of the postoperative disc space height.

5% 불화나트륨을 함유한 고분자 접착필름의 법랑질 재광화효과 (Effect of Polymer Adhesive Film Supplemented 5% NaF on Enamel Remineralization)

  • 지명관;이상호;이난영
    • 대한소아치과학회지
    • /
    • 제41권3호
    • /
    • pp.218-224
    • /
    • 2014
  • 이 논문은 법랑질의 표면미세경도와 QLF의 ${\Delta}F$ 값의 변화를 분석하여 5% 불화나트륨을 함유한 고분자 접착 테잎(NaF-PVA)이 법랑질의 재광화에 미치는 영향을 평가하고자하였다. 시편을 탈회한 후 표면미세경도가 평균 50-100 KHN의 범위를 갖고 QLF의 ${\Delta}F$ 값이 -25에서 -15 범위를 갖는 60개의 시편들을 4그룹으로 나누었다 : 그룹1(대조군), 그룹2(NaF-PVA), 그룹3(불소바니쉬, FluoroDose$^{(R)}$ varnish), 그룹4(Casein phosphopeptide-amorphous calcium phosphate, Tooth mousse plus$^{TM}$). 시편들에 각 제제들을 적용하고 인공타액(artificial saliva)에 담근 후 표면미세경도계와 정량 광 형광기를 이용하여 재광화율을 측정하였다. 그 결과 불소를 함유한 고분자 접착 테잎(NaF-PVA)은 그룹1과 4보다 뛰어나며 그룹3과 견줄만한 재광화 효과를 나타냈다 (p<0.05).

COMPARISON OF SHADE CHANGES ACCORDING TO DRY/WET CONDITION OF TEETH USING INTRA-ORAL COLORIMETER

  • Lee, Dong-Hwan;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jai-Bong
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.314-321
    • /
    • 2005
  • Objectives. The purpose of this study was to compare the shade changes in wet and dry conditions of natural teeth using two different intra-oral colorimeters. Materials and methods. Twenty volunteer subjects have no restorations and fillings in the maxillary central incisors were involved in this clinical study. The color of tooth was measured by two different instruments that were a Shade $Scan^{TM}$ System and a VITA $Easyshade^{(R)}$, Five times consecutive measurements were done for each subject with both instruments. Groups of measurement are an initial wet condition as control, dry in 5 minutes, 15 seconds after re-wetting with saliva, re-wetting after 5minutes and re-wetting after 30 minutes. Using ShadeScan $System^{TM}$, tooth image was captured and converted to the mapping image of Vitapan 3D master. Three main shades were chosen from each subject and calculated the area in Global Lab Image software. Data were analyzed using paired T-Test and Wilcoxon Signed Ranked Test. Using VITA $Easyshade^{(R)}$, color differences($\Delta$E) between measurements were analyzed with one sample T-test. Results. Using ShadeScan $System^{TM}$, there were significant differences between control group and dry(P=.023), dry and re-wetting 15 seconds, 5 minutes, 30 minutes as well(P=.021, P=.017, P=.030) in comparison of primary shade. However, comparing three main shades, there was no significant difference between control and dry(P=.105). Using VITA $Easyshade^{(R)}$, color differences($\Delta$E) between control and dry, dry and re-wetting 30 minutes were statistically different(P=.002, P=.022). Conclusion. Primary shade could be changed in dry and wetting procedure in time, however there was no significant shade changes in overall.

일부 시판 구강양치액이 치아에 미치는 영향 (Influence of Some Commercially Available Mouthwashes on Teeth)

  • 민지현
    • 치위생과학회지
    • /
    • 제18권4호
    • /
    • pp.265-270
    • /
    • 2018
  • 본 연구는 일부 시판 구강양치액의 화학적 특성을 조사하고, 구강양치액이 치아에 무기질 소실에 영향을 미치는지 확인하고자 하였다. 국내 3대 대형마트에서 공통으로 시판되는 구강양치액 5개 제품을 선정하였다(페리오토탈7 스트롱후레쉬[PS], 가그린 오리지널[GO], 가그린 제로[GZ], 리스테린 시트러스[LC], 리스테린 쿨민트[LM]). 구강양치액의 구성 성분과 pH와 적정산도를 조사하였다. 각 구강양치액 군별로 6개의 우치시편을 제작하였다. 각 구강양치액 30ml에 우치 시편 6개씩을 1분, 30분, 90분, 120분간 침적하였으며, 이때 $36.5^{\circ}C$ 교반 배양기에 위치하였다. 이후 치아의 무기질 소실 정도는 QLF-D를 이용하여 정상치아 대비구강양치액 노출 부위의 무기질 소실 정도(${\Delta}F$)를 분석하였다. 구강양치액군 간의 ${\Delta}F$의 차이를 Kruskal-Wallis H검정을 시행하여 알아보았다(${\alpha}=0.05$). 구강양치액의 성분은 리스테린 제품과 그 외 제품별로 차이가 있었으며, pH는 4.09~6.75의 범위를 보였다. 적정산도는 PS 제품이 평균 0.63 ml로 가장 적었으며 LM은 9.25 ml로 조사 제품 중 가장 높은 적정산도 값을 보였다. 리스테린 제품, LC와 LM에 90분 이상 치아 시편을 침적하였을 때 매우 적은 무기질 소실이 확인되었으나 통계적으로는 무기질 소실이 일어나지 않은 군과 유의한 차이가 확인되지 않았다(p>0.05). 결론적으로 시판 구강양치액 5종 모두 치아의 법랑질에는 위해가 없음을 확인하였다.

전부도재수복물을 위한 수종의 코어 세라믹의 반투명도 및 색 안정성 (Translucency and Color Stability of Various Core Ceramics for All-Ceramic Restoration)

  • 오상천;이해형;신미란;박광수
    • 구강회복응용과학지
    • /
    • 제23권2호
    • /
    • pp.157-170
    • /
    • 2007
  • Purpose: This investigation was designed to determine the translucency and color stability of various core ceramics for all-ceramic restoration using the CIE $L^*a^*b^*$ system. Material and Methods: IPS e.max Press ceramic(Ivoclar-Vivadent, Liechtenstein), $LAVA^{TM}$ All Ceramic(3M-Espe, Germany), Cercon Smart Ceramic(Dentsply, Germany), and Z-match Ceramic(DentAim, Korea) were used for this study. For the specimens of zirconia oxide ceramics, the as-sintered cylindrical blanks($11.0{\times}25.0mm$) were machined into the shape of a disk(0.4, 0.8, 1.5 mm in thickness, 10 mm in diameters) with a diamond grind machine. The IPS e.max Press specimens ($0.8{\times}10mm$) were fabricated using the "lost wax" technique. CIE $L^*a^*b^*$ coordinates and light transmission were recorded for each specimen with a spectrophotometer(CM-2600d, Minolta, Japan). Color differences were calculated using the equation, ${\Delta}E^*ab=[({\Delta}L^*)2+({\Delta}a^*)2+({\Delta}b^*)2]1/2$. Results: The results were obtained as follows: 1. The most translucent group was IPS e.max Press ceramic that is a glass-ceramic, and $Lava^{TM}$ and Z-match ceramic were more translucent than Cercon Smart ceramic in zirconia ceramic group. 2. In the all groups, there was no significant translucent change after 6 times heat-treatments required to make a final restoration. 3. Colored zirconia was showed more yellowish and dark than uncolored zirconia. 4. After heat-pressing, IPS e.max Press ceramic was showed high ${\Delta}E^*ab$ value(4.1 of eM1, 6.8 of eM2) that means to be more whiter than before heat-pressing. However, there was no color change after additive heat treatments for final restoration. 5. In the colored zirconia groups, there was no significant color change after some heat-treatments required to make a final restoration.