• 제목/요약/키워드: Delivery application

검색결과 890건 처리시간 0.028초

여성의 고위험 임신에 대한 경험 (Womans experience of Risk Situation on the High-Risk Pregnancy)

  • 김경원;이경혜
    • 여성건강간호학회지
    • /
    • 제4권1호
    • /
    • pp.161-178
    • /
    • 1998
  • In spite of the great progress of the theory and skill of the Nursing Care & Medical area in relation to pregnancy, nurses in clinics face up to many challenges in maternity nursing care areas. The reason is that the mobility and mortality of mothers was sharply decreased and the unknown high-risk diseases of pregnancy woman in the past is made public. That's why it is difficult to meet the pregnancy woman in natural process from pregnancy to delivery in recently. Admission rooms are filled with high-risk pregnancy women. As a matter of fact, we have done nursing care into the surface symptoms and diseases of high-risk pregnancy women so far. We have been indifferent to a long period hospitalization, separation from family, and conflict of repeated examination. Therefore, it is widely spread to understand the emotional conflict experienced by high-risk pregnancy women and to need for nursing intervention to bring up about emotional support and the ability of perception in psychological crisis. Although the pregnancy woman judged in high-risk should carry out normal task of pregnancy, she have to be confronted with secondary risk situation. The health of self & fetus threatened by the risk situation could be decreased through care plan, but psychological stress increases. Therefore, the pregnancy brings into non-control state. It is important to ask that what the hospitalized pregnancy women in high-risk think of themselves status. Because misunderstanding or serious anxiety of themselves status put into mother and fetus in danger. And adaptation mode makes all the difference. I would like to consider how nurses could deal with this high-risk circumstances in the position of pregnancy woman on the basis of the above fact. This study uses phenomenological method to suggest the basis material for nurses to do nursing intervention in view of pregnancy woman. Because this method understands the nature of true life of pregnancy woman throughly. The phenomenological method is the sources to describe or explain affluently the process generated in confirmation areas and environment and is the application for readers to understand and recognize clinic reality and then apply this method to reasoning study place or other places. Specifically, the phenomenon study method, one of the phenomenological method, is applied. The use of that method is to describe and generalize the experience in environment exactly. The study of this study is as follows : Among 187 descriptive stamens from 8 study participants are classified into 42 theme cluster at the stage of the first analysis. Those theme is categorized into 8 sub-subjects such as anxiety of uncertainty, foreknowledge about risk circumstance, will power about overcome, unsettled feeling about hospital, relief, optimistic thought, family support, and indifferences. At the last stage of analysis, those things are categorized into 3 subjects. When high-risk pregnancy woman foretell the situation, they feel unsettlement about uncertainty and untrust feeling about hospital. But they are ease with family support and hospital support. On the other hand, they express indifferent 3-way structure response to the situation having will of overcome and exceeding optimistic thought. In those statements, the experience by pregnancy woman shows 3 respect subjects. 1. They are anxious of this situation and are in desperation and don't recognize their role to be carried out 2. They think of this situation as normal process of pregnancy and are not concerned that this can give themselves and fetus fatal damage. 3. The pregnancy women will never confront this situation. This study shows the pregnancy woman has anxiety and optimistic relief about the situation, and ignores and optimistic relief about the situation, and ignores many things. Therefore, nurses in clinic should give pregnancy woman knowledge and information about the high-risk and help them to deal with the situation spontaneously. High-risk pregnancy woman should have the care plan in respect of the right perception. And the nurse know that their support help out pregnancy woman overcome the crisis in this respect of the special nursing intervention.

  • PDF

텍스트 마이닝 기법을 활용한 고전 추리 소설 작가 간 문체적 차이와 문체 구조에 대한 연구 (A study on detective story authors' style differentiation and style structure based on Text Mining)

  • 문석형;강주영
    • 지능정보연구
    • /
    • 제25권3호
    • /
    • pp.89-115
    • /
    • 2019
  • 본 연구는 고전 추리 소설 작가로 유명한 아서 코난 도일과 애거서 크리스티의 문체적 차이점을 데이터 분석을 통해 제시하고, 나아가 텍스트 마이닝에 입각한 문체 연구의 해석적 방법론을 제시하고자 시행되었다. 추리 소설의 핵심 요소인 사건과 인물에 더해 작가의 문법적인 집필 방식을 문체로 정의하고 분석을 시도하였다. 작가 별로 각 2권, 총 4권의 책을 선정하였으며 문장 단위로 텍스트를 나누어 데이터를 확보하였다. 각 문장에 따른 감성 점수를 부여한 뒤 페이지 진행에 따른 감성을 시각화하였으며, 페이지에 따라 토픽 모델링을 적용하여 소설 속 사건 진행 흐름을 파악할 수 있었다. 동시 발생 매트릭스(co-occurrence matrix)를 구성하고 네트워크 분석(Network Analysis)을 시행함으로써 사건이 진행되는 과정에서 인물들 간 관계의 변화를 확인할 수 있었다. 또한 전체 문장을 총 6가지 문체를 기준으로 문법적인 체계를 나누어 작가 간, 그리고 작품 간 집필 방식의 차이점을 확인하였다. 이러한 일련의 연구 과정은 문체에 대한 이해를 바탕으로 글 전체의 맥락을 파악할 수 있도록 도움을 줄 수 있으며, 나아가 기존에 개별적으로 진행되었던 문체 연구를 통합시킴으로써 문체 구조에 대한 이해를 도울 수 있다. 그리고 이러한 선행된 이해를 통해 온라인 텍스트를 비롯한 비정형 데이터 속 문체의 존재를 발견하고 구체화하는 작업에 기여할 수 있다. 뉴미디어를 포함한 온라인 텍스트를 심도 있게 분석하고자 하는 시도가 증가하고 있는 상황에서 해당 연구들과 연계를 통해 보다 의미 있는 온라인 텍스트 분석에 기여할 것으로 기대된다.

네팔의 포용적 비즈니스 프로그램 평가에 관한 연구: 경제협력개발기구 개발원조위원회 평가기준 적용을 중심으로 (A Study on the Evaluation of Nepal's Inclusive Business Solution: Focusing on the Application of OECD DAC Evaluation Criteria)

  • 김연홍;이성순
    • 한국콘텐츠학회논문지
    • /
    • 제21권4호
    • /
    • pp.177-192
    • /
    • 2021
  • 경제협력개발기구 개발원조위원회에서는 국제적으로 통용되는 공적개발원조위원회 5대 평가기준 개편에 대하여 논의하고 1991년 공적개발원조 평가 시 적절성·효율성·효과성·영향력·지속가능성 등 5대 평가 기준의 적용을 권고한 바 있다. 본 연구는 2019년부터 네팔에서 시행 중인 포용적 비즈니스 프로그램의 평가에 있어 경제협력개발기구 개발원조위원회 평가기준을 적용하여 분석하고 개선과제를 도출하는데 있다. 연구 방법은 네팔 현장조사와 포커스 그룹 미팅 방법을 적용하였다. 연구 결과 네팔 포용적 비즈니스 프로그램의 적절성은 장애인, 고아 여성 등 취약계층 대상 지속적인 고용과 일자리 창출에 부합되었고 특히, 한국의 시각적 특수효과에 대한 수요가 증가하는 시점인데다 네팔 취약계층 대상 컴퓨터 그래픽 전문교육을 통한 인력양성이라는 점에서 프로그램이 적정하다고 볼 수 있다. 효율성은 작업지시와 작업컨펌 등의 과정이 전자식 관리 툴로 이루어지고 결과물의 납품이 온라인으로 전송되어 타업종에 비해 시간과 비용이 절감된다는 점에서 효율적이라고 할 수 있다. 효과성은 본 사업이 네팔의 장애인, 고아 여성 등 취약계층 대상 컴퓨터 그래픽 전문교육을 실시하고 수료생을 직원으로 채용하는 등 양질의 일자리를 제공한 점에서 효과성이 있는 프로그램이라고 할 수 있다. 지속가능성은 코이카 포용적 비즈니스 프로그램이 기존 농업, 제조업의 분야에서 종사하는 취약계층들로 하여금 컴퓨터 그래픽 업종에 종사하게 한 점과 영화, 캐릭터, 교육사업의 확장성, 타국가의 롤모델이 될 수 있는 점에서 지속가능성이 있다고 볼 수 있다. 향후 공적개발원조의 규모가 증가할 것을 고려한다면 체계적인 모니터링 시스템과 환류체계의 구축 등 공여국과 수원국 양국간 사업의 지속방안 마련이 요구된다.

과분지 폴리글리세롤(HPG) 강화를 통해 기계적 물성이 향상된 새로운 천연 고분자 기반 자성 하이드로젤의 제조 (Preparation of Novel Natural Polymer-based Magnetic Hydrogels Reinforced with Hyperbranched Polyglycerol (HPG) Responsible for Enhanced Mechanical Properties)

  • 장은혜;장지수;권세현;박정현;정유정;정성욱
    • 청정기술
    • /
    • 제29권1호
    • /
    • pp.10-21
    • /
    • 2023
  • 천연 고분자 이중 네트워크를 기반으로 하는 하이드로젤은 뛰어난 생체 적합성, 낮은 세포 독성, 높은 함수율을 가져 다양한 의학 분야 재료로서 우수한 성능을 가지며 생체 조직 내 표적 약물 전달 시스템에의 응용에도 많은 주목을 받고 있지만 상대적으로 약한 기계적 물성에 의한 한계를 가진다. 본 연구에서는 천연 고분자 산화 알지네이트(alginate di-aldehyde, ADA)와 젤라틴(gelatin)이 형성하는 이중 네트워크 기반의 하이드로젤을 합성하였으며 하이드로젤 내부의 기능기와 수소 결합을 할 수 있는 다량의 수산기(-OH) 기능기를 가지는 과분지 고분자(hyperbranched polyglycerol, HPG)를 0~25%의 범위로 조절하여 첨가하여 최종적으로 기계적 물성이 향상된 천연 고분자 기반 하이드로젤을 합성하였다. 또한, 자철석 나노 입자(Fe3O4 nanoparticles (NPs))를 하이드로젤 내부에 in-situ 방법으로 합성하여 자성이 부여된 천연고분자 하이드로젤의 제조 및 특성 분석을 진행하였다. 결과적으로 Fe3O4 NPs를 도입한 15% HPG 함량의 하이드로젤은 3.8 emu g-1의 포화자화 값을 가지는 초상자성을 보였고, 변형률 67.4%에서 최대 압축 강도 1.1 MPa으로 높은 기계적 물성을 가졌다. 향상된 기계적 물성을 가지는 천연 고분자 기반의 초상자성 하이드로젤은 약물 전달 시스템 및 생체 재료에 매우 중요한 잠재적 용도가 있을 것으로 사료된다.

텍스트마이닝을 통한 최고경영자 대상 이러닝 콘텐츠 트렌드 분석 (Text Mining-Based Emerging Trend Analysis for e-Learning Contents Targeting for CEO)

  • 김경훈;채명신;이병태
    • 경영정보학연구
    • /
    • 제19권2호
    • /
    • pp.1-19
    • /
    • 2017
  • 본 연구는 텍스트마이닝 기법 중 토픽 분석을 활용하여 관련 업계 국내 1위 S사(社)의 최고경영자 대상 온라인 교육 콘텐츠 강의 중심으로 원문 스크립트를 분석했다. 지난 5년간(2011~2015)년 서비스된 총 4,824개 콘텐츠를 바탕으로 핵심 키워드를 추출한 다음 주제별 22가지 토픽으로 분류한 후 동향 분석을 수행했다. 이를 통해 최근 콘텐츠 비중이 급증하고 있는 토픽 주제를 확인할 수 있었다. 다음으로 토픽 분석을 통해 분류한 토픽 및 카테고리를 바탕으로 회원 평가 요인을 적용해 카테고리 및 각 토픽별 지적 관심도를 체계화 할 수 있었다. 경영·경제 분야에서는 마케팅전략, 인사/조직, 커뮤니케이션 분야 등이 높은 관심도와 만족도를 나타냈다. 인문 분야에서는 철학, 전쟁사, 역사(서양) 라이프스타일에서는 마음건강 분야가 관심도와 만족도 둘 다 높은 것으로 나타났다. 이와 함께 교육용 콘텐츠가 시대 변화에 민감하게 반응할지라도 회원의 관심과 만족도 제고에는 실패할 수 있다는 사실을 확인할 수 있었다. 최근 콘텐츠 비중은 급증했지만 평균 이하의 만족도를 기록한 IT기술 토픽이 대표적 사례라 할 수 있다. 이를 통해 최고경영자 대상 콘텐츠 제작 시 단순히 기술적 측면의 정보전달에서 끝나는 것이 아닌 기술 적용을 통한 가치혁신에 대한 깊이 있는 시사점을 도출하거나 풍부한 영상 자료를 바탕으로 다양한 볼거리를 제공하는 등 양적인 측면과 함께 질적인 측면을 고려해야 한다는 교훈을 얻을 수 있었다. 본 연구는 포털 사이트 혹은 SNS 자료가 아닌 국내 가장 영향력 있는 이러닝 기업 데이터를 토대로 분석을 진행했기에 보다 심도 있고 실용적인 결과를 도출했다. 또한 이러닝 관련 연구 분야에서 지금까지는 드물었지만 기술의 발달로 점점 연구 조사 방법론으로 기대가 높아진 텍스트마이닝 방법에 대하여 그 적용 가능성을 성공적으로 탐색해 보았다. 기존에는 콘텐츠 운영 현황 분석 시 콘텐츠 프로그램명에 입각, 표면적인 방식으로 분류할 수밖에 없는 한계가 존재했다면 텍스트마이닝 방법론을 활용하면 비정형 데이터 콘텐츠 스크립트를 바탕으로 분석하여 내용을 바탕으로 한 보다 심도 있는 콘텐츠 분류 및 주제 분류를 이끌어 낼 수 있다. 이를 바탕으로 연도에 따른 주제별 콘텐츠 서비스 현황을 도식화한다면 현재 부족한 분야와 필요한 분야에 대한 보다 심도 있는 고찰이 가능하다. 본 연구는 다양한 텍스트마이닝 기법 중에서 이러닝의 상황에서 효과적으로 연구하기 위한 새로운 방법론을 제시했으며 향후 최고경영자 교육 관련 분야별 지적 관심도에 대한 분석에 도움이 될 것으로 기대된다.

항공보안 관련 국제협약의 현대화와 국내입법의 이행 연구 (A Study on Modernization of International Conventions Relating to Aviation Security and Implementation of National Legislation)

  • 이강빈
    • 항공우주정책ㆍ법학회지
    • /
    • 제30권2호
    • /
    • pp.201-248
    • /
    • 2015
  • 우리나라는 항공수요의 증가에 따라 항공기내 불법방해 행위의 발생건수도 계속 증가하고 있는데, 2010년에 55건, 2014년에 354건이 발생하여, 지난 5년간 매년 평균 211건이 발생하였다. 1963년 항공보안에 관한 최초의 전 세계적 국제법률문서로서 새로운 "항공기내에서 범한 범죄 및 기타행위에 관한 협약"인 동경협약이 채택되었다. 동경협약이 발효된 1969년 직후 바로 1970년에 "항공기내 불법납치 억제를 위한 협약"인 헤이그협약이 채택되었고, 1971년에 "민간항공의 안전에 대한 불법적 행위의 억제를 위한 협약"인 몬트리올협약이 채택되었다. 2001년 9/11 사건이후 1971년에 채택된 몬트리올협약을 수정 보완하는 "국제민간항공과 관련된 불법행위억제에 관한 협약"인 2010년 베이징협약과 1970년에 채택된 "항공기 불법납치의 억제를 위한 협약"인 헤이그협약을 보충하는 2010년 베이징의정서가 채택되었다. 그 후 항공기내 난동행위의 심각성과 빈번함이 확대되고 있음에 따라 1963년에 채택된 "항공기내에서 범한 범죄 및 기타행위에 관한 협약"인 동경협약을 개정하는 2014년 몬트리올의정서가 채택되었다. 우리나라가 가입한 발효된 항공보안 관련 국제협약으로는 1963년 동경협약, 1970년 헤이그협약, 1971년 몬트리올협약, 1988년 몬트리올보충의정서, 1991년 가소성폭약표지협약 등이 있다. 우리나라는 1971년에 동경협약을 비준함에 따라 1974년에 항공기운항안전법을 제정하였고, 2002년 8월에 항공기운항안전법을 대체한 항공안전 및 보안에 관한 법률이 제정되었으며, 2014년 4월에 항공안전 및 보안에 관한 법률은 항공보안법으로 명칭이 변경되었다. 항공보안법은 본질에 있어서 1963년 동경협약과 1970년 헤이그협약의 이행입법이다. 또한 항공보안법상의 용어는 ICAO 회람장 288(Circular 288)의 모델입법 제1조 내지 제3조의 난동 및 방해 행위보다 넓다. 한편 항공보안법은 현대화된 항공보안 관련 국제협약인 2010년 베이징협약 및 베이징의정서 그리고 2014년 몬트리올의정서상의 국내입법 사항들을 상당부분 반영하고 있다. 그러나 앞으로 이들 국제협약들이 발효되고 우리나라가 가입할 경우 국내입법인 항공보안법 상 개정 또는 신설되어야 할 사항들로는 재판관할권, 비행 중의 정의, 기장 등의 소송상 면책, 기장 등의 범인 인도 의무화, 범법자의 처벌 강화, 공범의 적용확대 및 국제협약의 준수 등에 관한 규정을 들 수 있다. 이 들 가운데 특히 재판관할권의 범위에 관하여 우리나라 입법은 침묵하고 있다. 그러므로 항공기내 난동 및 방해 범죄의 영토외적 사건 등에 대하여 재판관할권이 확대되기 위하여 항공보안법이나 형법총칙을 개정하는 것이 바람직할 것이다. 결론적으로, 점차 지능화 및 다양화되어 가고 있는 항공보안 위협에 대응하기 위하여 우리정부는 항공보안 관련 국제협약의 내용 및 각국의 비준현황을 면밀히 검토하여, 우리나라의 협약 가입 및 협약 상 국내입법 사항의 이행을 위해 항공보안 관련 입법과 항공보안제도를 개선하도록 노력하여야 할 것이다.

기계 호흡 중 불안정한 호흡역학을 보인 환자에서 압력조절용적조정양식(Pressure-regulated Volume Control Mode)의 효용 (The Usefulness of Pressure-regulated Volume Control(PRVC) Mode in Mechanically Ventilated Patients with Unstable Respiratory Mechanics)

  • 손장원;고윤석;임채만;심태선;이종덕;이상도;김우성;김동순;김원동
    • Tuberculosis and Respiratory Diseases
    • /
    • 제44권6호
    • /
    • pp.1318-1325
    • /
    • 1997
  • 연구배경 : 일정한 분시 유지하면서도 기도압의 하나인 압력조절용적조정양식(PRVC)의 입상적 유용성에 대한 보고는 없었다. 본 연구는 호흡역학이 불안정한 환자에서 PRVC 양식이 원래의 개발 목적대로 압력 조절 양식에 비해 일호흡량을 일정하게 유지하면서 용적조절양식에 비해 기도압을 낮게 유지하는지를 관찰하였다. 연구방법 : 기계 호흡 중이며 활력징후의 안정을 보이는 환자 중 15분간 관찰 결과 VCV에서 최고 홉기압의 변이계수가 10이상으로 최고 홉기압의 변화가 심하거나, PCV에서 상시 호흡량의 변이계수가 10이상으로 일 호흡량의 변화가 심한 환자 8 명(남 : 녀=6 : 2, $56{\pm}26$세)를 대상으로 하여 일호흡량을 비슷한 유지하도록 VCV, PCV, PRVC 양식을 설정한 후 각 환기양식에서 15분간 일호흡량과 최고 흡기압을 관찰하였다. 결 과 : 1) 평균 일호흡량은 VCV에서 $431{\pm}102ml$, PCV에서 $417{\pm}99ml$, PRVC에서 $414{\pm}97ml$였으며 각 환기양식 간에 차이가 없었다. 2) 상시 호흡량의 변이계수는 VCV에서 $5.2{\pm}3.9%$, PCV에서 $15.2{\pm}7.5%$ PRVC에서 $19.3{\pm}10.0%$로 PCV와 PRVC에서 상시 호흡량의 변화가 심하였다(p<0.01). 3) 평균 최고 홉기압은 VCV에서 $31.0{\pm}6.9cm$ $H_2O$, PCV에서 $26.0{\pm}6.5cm$ $H_2O$, PRVC에서 $27.0{\pm}6.4cm$ $H_2O$로 PCV와 PRVC의 최고 흡기압의 VCV의 경우보다 낮게 유지되었다(p<0.01). 4) 최고 홉기압의 변이계수는 VCV에서 $13.9{\pm}3.7%$, PCV에서 $4.9{\pm}2.6%$, PRVC에서 $12.2{\pm}7.0%$로 VCV와 PRVC에서 최고 홉기압의 변동이 심하였다(p<0.01). 결 론 : PRVC 양식은 호흡역학이 불안정한 환자에서는 VCV에 비해 평균 최고 홉기압은 낮게 유지하였으나 최고 흡기압의 변동이 심하였고, PCV에 비해 상시 호흡량의 변동이 심하여 이중조절환기양식 본래의 목적을 달성하기 어려울 것으로 사료된다.

  • PDF

지방자치단체 자체 복지사업 지출 영향요인 분석 : 사회보장정보시스템을 통한 접근 (Analysis on Factors Influencing Welfare Spending of Local Authority : Implementing the Detailed Data Extracted from the Social Security Information System)

  • 김경준;함영진;이기동
    • 지능정보연구
    • /
    • 제19권2호
    • /
    • pp.141-156
    • /
    • 2013
  • 그 동안 한국 사회에서 지방자치단체(이하 지자체) 복지사업과 재정지출에 대한 연구는 장애인, 노인, 보육 등 복지사업 대상 등을 중심으로 부문별 복지지출에 대한 영향요인 연구가 대부분 이루어져 왔다. 최근 지자체의 자체적인 복지노력도 측면에서 자체 사업에 대한 연구가 특정 지역의 사례를 중심으로 이루어지기는 하고 있지만, 자료에 대한 접근과 조사의 한계로 여러 요인이 실증적으로 고려되지 못하여 정책적 함의를 도출해 내기 어려웠다. 현재 우리사회의 복지예산과 그 지출규모는 국가 예산의 30%에 이를 만큼 높은 비중을 차지하고 있다. 이에 따라 국가적 차원에서 공공복지 전달체계의 효율적 운영과 관리를 위해 사회보장 정보시스템을 구축, 운영하고 있다. 본 연구에서는 기존 연구에서 사용하는 지방재정시스템이 아닌 사회보장 정보시스템을 통하여 지자체 복지재정 지출과 관련, 기존 연구에서 한계점으로 지적되었던 전수데이터에 대한 접근과 조사를 실시하여 학문적이고 정책적인 함의를 도출해 내고자 한다. 사회보장정보시스템은 복지전달체계의 효율화를 위해 구축되었으며, 이를 통해 17개 부처 292개 복지사업이 집행되며, 230개 지자체 4만여 개 복지사업의 정보가 관리되고 있다. 이에 따라 본 연구는 사회보장정보시스템을 통해 관리되는 지자체 복지사업을 중심으로 지자체 복지지출에 미치는 영향요인을 탐색하고자 한다. 이를 위해 지자체 복지노력도로 대변되는 순수 시 군 구 복지예산액을 종속변수로 설정하였으며, 기존문헌 검토를 바탕으로 인구사회학적, 지역 경제적 그리고 지자체 재정적 요인을 독립변수로 설정하였다. 또한 독립변수 요인간 다중공선성 문제를 점검하였고, 다중공선성의 문제가 없는 것으로 확인된 수급자 비율, 영유아 비율, 아동청소년 비율, 복지비 비율, 구인배율, 재정자립도, 재정자주도의 총 7개 독립변수와, 소속 정당을 통제변수로 사용하여 결정요인의 변화를 분석하였다. 연구결과를 살펴보면 기본모델에서는 복지비 비율, 영유아 비율, 재정자립도, 재정자주도, 구인배율이 유의한 영향을 미치는 것으로 분석되었다. 그리고 기존 문헌에서 분석되지 못했던 시 군 구별 복지지출 영향요인의 차이점을 분석하였다. 또한 복지예산 총량 데이터에 근거한 기존 연구들이 논의하지 못했던 자체 복지사업 예산에 미치는 영향요인을 구체적으로 밝혀내는데 의의가 있다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF