• Title/Summary/Keyword: Dehumidifiers

Search Result 14, Processing Time 0.027 seconds

The Analysis of the Effects of Design Parameters on the Energy Efficiency and Performance of TEM Dehumidifiers (열전모듈 제습기의 에너지 효율과 성능에 미치는 설계 인자의 영향 분석)

  • Lee, Tae-Hee
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.3
    • /
    • pp.1-7
    • /
    • 2020
  • To provide a design direction for high efficiency thermoelectric module(TEM) dehumidifiers, the effects of design factors of TEM dehumidifiers on dehumidification energy efficiency and performance were numerically investigated. The design factors considered in this study are the TEM capacity, the performance of heat exchangers on the heating and cooling surfaces of the TEM. The higher capacity of the TEM results the higher dehumidification energy efficiency and performance at some operating voltage. The enhanced performance of the heat exchanger on heating surface increased the dehumidification energy efficiency and performance at all the operating voltage. The enhanced performance of the heat exchanger on cooling surface decreased the dehumidification energy efficiency and performance at all operating voltage.

A Study on the Characterizations of Silica-Ceramic Paper Dehumidifiers Impregnated with Zeolites (제올라이트가 도포된 실리카-세라믹 제습제의 특성)

  • Jung, Suk-Yong;Lee, Soo-Chool;Chae, Ho-Jin;Lee, Soo-Jae;Park, Jung-Je;Ahn, Young-Soo;Kim, Hong-Su;Kim, Jae-Chang
    • Clean Technology
    • /
    • v.14 no.1
    • /
    • pp.40-46
    • /
    • 2008
  • The dehumidifiers were prepared by the impregnation of the zeolites such as MCM 48, USY, beta on the silica ceramic paper. Their capacities for $H_2O$ absorption and regeneration of the bed were tested in a fixed bed reactor system. The $H_2O$ absorption capacities of the dehumidifiers impregnated with the zeolites were $1.5{\sim}2$ times higher than those without the zeolites. Especially, the humidifier using MCM 48 and colloidal silica showed an excellent capacity (42.1g $H_2O/g$ absorbent). It was found that the $H_2O$ absorption capacities of the dehumidifiers were improved because the amount of silica gel, the main component in absorbing $H_2O$, increased due to the large surface area and pore volume of the zeolites. In addition, $H_2O$ was easily desorbed from the dehumidifiers with zeolites at $80^{\circ}C$ of regeneration temperature and the desorption amount of $H_2O$ was the same as that absorbed. It was confirmed that the $H_2O$ absorption capacities of the dehumidifiers impregnated with zeolite were maintained without deactivation through the repeated cyclic experiments.

  • PDF

Improving Efficiency of Dehumidifiers via Nature-Inspired Technology (제습기의 에너지 효율증가를 위한 자연모사기술의 제안)

  • Yun, Seongjin;Song, Kyungjun;Park, Byung Kil;Kim, Wandoo;Kang, Sanghyeon;Lee, Sun Yong;Lim, Hyuneui
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.2
    • /
    • pp.211-219
    • /
    • 2013
  • Even though global warming and humid climate have resulted in an increase of use of dehumidifiers, they are not becoming more common because of high energy consumption. Furthermore, conventional dehumidifier technology finally reaches the limit to increase energy efficiency of water collection. As an alternative, nature-inspired technology may lead to a major breakthrough in the dehumidification performance. In order to improve the efficiency of dehumidifiers, we first analyze the energy consumption of commercial dehumidifiers and then study bioinspired water collection methods adopted by Namib beetles and grass.

Basic concept and present condition of domestic market for dehumidifiers (제습의 기초 및 제습기의 국내 판매현황)

  • 문인호
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.27 no.6
    • /
    • pp.523-532
    • /
    • 1998
  • 우리나라의 여름철 기후는 장마라는 일정기간의 우기와 더불어 고온 다습한 특성을 가지고 있다. 다습한 환경은 주거환경에서 곰팡이 균이 번식하는데 좋은 조건이 되며, 산업환경에서는 각종 기자재 및 원자재를 부식시키고, 일부 작업 공정을 어렵게 하는 문제점을 유발한다. 반면, 온도는 높지만, 습도가 낮은 중동 사막지역의 경우는 수 천년 동안 미이라가 훌륭하게 보존되어 왔다. 따라서 상대적으로 고습 기후 조건을 갖는 지역은 저습 기후 지역에 비하여 더 큰 습도제거 대책이 필요하게 되는 불리함이 있다.

  • PDF

A Numerical Study on the Design of Exchanger for Desiccant Dehumidifier (데시칸트 제습기용 열교환기 설계에 관한 수치해석적 연구)

  • Kim, Chi-Wan;Ahn, Young-Chull;Kim, Gil-Tae
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.54-62
    • /
    • 2013
  • A numerical analysis is performed to evaluate mass flow balance in the heat exchanger for the dehumidifier. To improve the mass flow balance for maximum heat transfer performance, inlet, outlet and baffle are changed. Mass flow balance is evaluated by non-uniformity of flow which is the same concept with the standard deviation. Usually, there will occur many paths between the inlet and the outlet, however, it will follow shortest and low resistance ways. The uniform distribution of flow is numerically analyzed for several types of heat exchangers. Making the shortest way between the inlet and the outlet is most important factor. Two types of heat exchangers are installed in the dehumidifier and 4 cases of Type A heat exchangers and 3 cases of Type B heat exchangers are evaluated and optimized. The result of this research is applied to design heat exchanger for commercial dehumidifiers.

Preparation and characteristics of inorganic membrane for air dehumidification (공기 제습용 무기막의 제조 및 특성)

  • Kim, Jeong-Eun;Kim, Byoung-Moon;Song, Kun-Ho;Chang, Wha-lk;Lee, Kwang-Rae
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.157-162
    • /
    • 2006
  • Recently, the humidity adjustment of indoor air is of great importance in air conditioning system as a applied, in buildings, vehicles, and containers for storage and transport of perishable products. Membrane dehumidification or air is potentially attractive because it offers low capital and operating costs, along with low energy consumption. And membrane dehumidification process attracted the attention of the public instead of the other dehumidification processes, such as adsorption, absorption, and refrigeration cycles and so on. In this study, the prepared hydrophilic inorganic membrane-based dehumidifiers(membrane air dehumidification) examined the performance of dehumidification. The surface-modified inorganic membrane prepared in this study showed high dehumidification efficiency(over 80%). The membrane might be very useful for dehumidification industries.

  • PDF

Development of High Efficiency Dehumidifiers in low temperature (저온에서 고효율 제습기 개발)

  • Kim, Jong-Ryeol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.206-211
    • /
    • 2016
  • Various applications require dry air at low temperature, such automation equipment, semiconductor manufacturing, chemical production lines, and coating processes for the shipbuilding industry. Four evaporators for low temperature (below $0^{\circ}C$) were installed for a dehumidification system. Moist air is cooled sequentially over three evaporators. The first evaporator has an evaporation temperature of $13^{\circ}C$, that of the second evaporator is $5^{\circ}C$, and that of the third evaporator is maintained at $-1.3^{\circ}C$. In the fourth evaporator implantation thereby the moisture contained in the moisture air. A pressure regulator (CPCE 12) is used at this point and is defrosted when the vapor pressure is below a set value. The non-implantation moisture of the air is a heating system that uses the waste heat of a condenser with high temperature. It develops the cooling type's dehumidifier, which is important equipment that prevents the destruction of protein and measures the temperature and humidity at each interval by changing the front air velocity from 1.0 m/s to 4.0 m/s. The cooling capacity was also calculated. The greatest cooling capacity was 1.77 kcal/h for a front air velocity of 2.0 m/s

Development of a Drain-Type Electronic Dehumidifier Using Thermoelectric Element (열전소자를 이용한 배수형 전자제습기 개발)

  • Kang, Deok-Hong;Kim, Seong-Hwan;Kim, Ki-Hong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3524-3528
    • /
    • 2007
  • In this study, the Peltier effect was applied to eliminate moistures in the air enclosed by a cabinet. We have developed the new electronic dehumidifier which has a new function of automatically evaporating the condensed water inner cabinet into the outside air. To obtain this function, the processes of dehumidification is that it condensed the moistures on the cold side heat sink and drained it into the hot side heat sink by the both gravitational and capillary forces and the droplets on the hot side heat sink surface was evaporated into the air outside the cabinet by the heat conducted through the hot side heat sink surface and the forced heat convection through the fan for cooling hot side heat sink. Compared to existing electronic dehumidifiers, this manufactured one showed a good performance that the electric power consumption for the same dehumidifying quantity was reduced by 50% compared with that of existing ones.

  • PDF

Prediction of Latent Heat Load Reduction Effect of the Dehumidifying Air-Conditioning System with Membrane (분리막 제습공조시스템의 잠열부하 저감효과 예측)

  • Jung, Yong-Ho;Park, Seong-Ryong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.1
    • /
    • pp.15-20
    • /
    • 2017
  • The summer climate is very hot and humid in Korea. The humidity is an important factor in determining thermal comfort. Recently, the research for dehumidification device development has been attempted to save energy that is required for the operation of the current dehumidifiers on the market. Existing dehumidification systems have disadvantages such as wasting energy to drive a compressor. Meanwhile, dehumidification systems with membranes can dehumidify humid air without increasing the dry bulb temperature so it doesn't have to consume cooling energy. In this paper, the cooling energy savings was studied when a dehumidification system was applied in a model building instead of a chiller. The sensible heat load was almost the same result, but the latent heat load was decreased by 38.9% and the total heat load was decreased by 8.5%. As a result, electric energy used to drive the compressor in a chiller was saved by applying a membrane air-conditioning system instead.

Condensation Reduction Study of an Apartment Underground Elevator Hall with respect to Dehumidifier Locations (제습기 설치 위치에 따른 공동주택 지하 엘리베이터홀의 결로 저감 연구)

  • Park, Jong-Jun;Kim, Young-Il;Kim, Jong-Yeob;Kim, Gil Tae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.4
    • /
    • pp.169-174
    • /
    • 2014
  • Computational fluid dynamics simulation of an apartment underground elevator hall has been carried out to study the effect of dehumidifier locations on condensation problem. In Case 1, horizontal position of humidifier is studied. It is installed at entrance, center or the inside of the elevator hall. In Case 2, installation height is studied, one at 0 m and the other at 1.6 m above the floor. In Case 3, exposed and embedded dehumidifiers are compared for performance. The study shows that the entrance, top and exposed locations are more effective in reducing condensation.