• Title/Summary/Keyword: Degree of saturation

Search Result 376, Processing Time 0.037 seconds

Variation in Characteristics of Elastic Waves in Frozen Soils According to Degree of Saturation (포화도에 따른 동결토의 탄성파 특성 변화)

  • Park, Jung-Hee;Kang, Min-Gu;Lee, Jong-Sub
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.1063-1075
    • /
    • 2013
  • The strength of frozen soils is one of the significant design parameters for the construction in frozen ground. The properties of frozen soils should be investigated to understand the strength of frozen soils. The objective of this study is to figure out the characteristics of elastic waves in frozen soils, which reflect the constituent and physical structure of frozen soils in order to provide fundamental information of those according to the degree of saturation. Freezing cell is manufactured to freeze specimens, which are prepared with the degree of saturation of 10%, 40%, and 100%. Piezo disk elements are used as the compressional wave transducers and Bender elements are used as the shear wave transducers. While the temperature of specimens changes from $20^{\circ}C$ to $-10^{\circ}C$, the velocities, resonant frequencies and amplitudes of the compressional and shear waves are investigated based on the elastic wave signatures. Experimental results reveal that the elastic wave velocities increase as the degree of saturation increases. The variation of resonant frequencies coincide with that of elastic wave velocities. A marked discrepancy in amplitudes of compressional and shear waves are observed at the temperature of $0^{\circ}C$. This study renders the basic information of elastic waves in frozen soils according the degree of saturation.

The Characteristics of Electrokinetic Remediation for Unsaturated Soil (불포화토의 동전기정화 특성에 관한 실험적 연구)

  • 김병일;김익현;한상재;김수삼
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.641-646
    • /
    • 2003
  • In this study, a series of electrokinetic(EK) remediation experiments are carried out under the different degree of saturation for contaminated soil with lead. for constant electrical potential, the final current of all the sample represents the similarity to steady-state value of 5∼7mA. Under conditions of all the degree of saturation the anode reservoir becomes acidic(pH as low as 3) while the cathode reservoir is basic(pH as high as 12). But pH changes in the sample is a little and decontamination efficiency is the low.

  • PDF

Roundabout Signal Metering Operation Methods by Considering Approach Lane's Degree of Saturation (접근로별 포화도를 고려한 Roundabout Signal Metering 운영방법에 관한 연구)

  • Ahn, Woo-Young;Lee, So-Young
    • International Journal of Highway Engineering
    • /
    • v.15 no.5
    • /
    • pp.217-226
    • /
    • 2013
  • PURPOSES : Under the capacity conditions with balanced approach flows, roundabouts give less delay than existing signalized intersections; however, flows over 450 vehicles/hour/lane with unbalanced approach flow conditions, roundabouts efficiency drops due to the short time difference between the critical gap and the follow-up headway. The purpose of this study is developing a roundabout Signal Metering operation method by considering approach lanes degree of saturation. METHODS : A four-way-approach with one-lane roundabout is selected to compare the Signal Metering performance for the case of 16 different unbalanced flow conditions. Based on these traffic conditions, the performance is evaluated for 64 different cases of Signal Metering combinations by using SIDRA software. A degree of saturation(V/C ratio) sum for two adjoined approaches is used for the performance index of choosing Metered Approach and Controlling Approach. RESULTS : When the V/C ratio sum is 0.29~0.81 and Metered Approach flow is less than Controlling Approach flow, the average delay saving per vehicle is about 7 seconds; however, after this rage the delay saving decreases gradually until the V/C ratio sum reaches around 1.0. The range of V/C ratio sum 0.93~1.09 provides average delay saving per vehicle about 3 seconds. In case of V/C ratio sum is grater than 1.0 and the flows of Metered Approach is grater than Controlling Approach, the average delay per vehicle increases 3~11 times respectively. CONCLUSIONS : As expected, the Signal Metering provides substantial improvements in delay saving for the case of V/C ratio sum is 0.3~1.0 under the traffic flow conditions of Metered Approach is less than Controlling Approach.

Comparative Study on Unsaturated Characteristic Curves of Boeun Granite Weathered Soil during Drying and Wetting Paths (건조 및 습윤과정에서 보은 화강암 풍화토의 불포화특성곡선 비교)

  • Song, Young-Suk
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.7
    • /
    • pp.15-24
    • /
    • 2016
  • To investigate the unsaturated characteristics of the Boeun granite weathered soil, matric suction and volumetric water content were measured in both drying and wetting paths using Automated Soil-Water Characteristics Curve Apparatus. Based on the measured results, Soil-Water Characteristics Curve was estimated by van Genuchten (1980) model. The relationship between effective degree of saturation and matric suction showed the non-linear curve with S-shape and the hysteresis phenomenon occurred during drying and wetting paths. Suction Stress Characteristics Curve was estimated by the Lu and Likos (2006) model. The suction stress in drying path was constantly maintained and that in wetting path tended to increase when the effective degree of saturation was low. But the suction stress in drying path was larger than that in wetting path at the same degree of saturation when the effective degree of saturation became larger. Meanwhile, Hydraulic Conductivity Function was evaluated by the van Genuchten (1980) model which is one of the parameter estimation methods. The unsaturated hydraulic conductivity decreased with increasing the matric suction, and the decreasing velocity regarding to the matric suction in drying path was larger than that in wetting path.

Effect of Tillage on Nonpoint Source Pollution of Surface and Ground Water System (I); Effect of Tillage Practices on Density and Saturation of Soil

  • ;shirmohammadi,Adel
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.34 no.E
    • /
    • pp.1-11
    • /
    • 1992
  • Increasing national concern on nonpoint source pollution of surface and ground water Systems has led researchers and policy makers to develop certain agricultural Best Management Practices. As an initial step of broad study program above mentioned, this study reflected the effects of different tillage practice on bulk density and degree of saturation on two regional soils, namely Tama silt loam and Catlin silt loam. Results may help to clarify some of the conflicting findings on the impact of tillage systems on these parameters and it may also explain some of the reasons for specific role that different tillage systems play regarding nonpoint source pollution from agricultural fields.

  • PDF

On a Reading Aloud to Relieve the Decrease in Blood Oxygen Saturation when Jogging

  • Tian, Zhixing;Bae, MyungJin
    • International Journal of Advanced Culture Technology
    • /
    • v.8 no.4
    • /
    • pp.95-100
    • /
    • 2020
  • Recently, the problem of hypoxia caused by jogging is attracting attention. To solve this problem, this paper proposed a new solution. This paper proved that as a vocalization method of reading aloud, it is possible to increase air intake and activate lung function to exchange more air and obtain more oxygen. Then, blood oxygen saturation was used as an evaluation index for the body's oxygen content level to prove its effectiveness. A photoelectric pulse oximeter developed on the basis of different light absorption principles in blood was used to test blood oxygen saturation. Experimental results show that a certain degree of hypoxia is induced when a lot of oxygen is required due to jogging. Therefore, it was proved that the new vocal breathing method by reading books can increase the blood oxygen saturation of the body and improve the hypoxia of the body. Reading vocal breathing is a simple and efficient oxygen saturation recovery breathing method.

The Effect of Surface Tension on Shear Wave Velocities according to Changes of Temperature and Degree of Saturation (온도와 포화도의 변화에 의한 표면장력이 전단파 속도에 미치는 영향)

  • Park, Jung-Hee;Kang, Min-Gu;Seo, Sun-Young;Lee, Jong-Sub
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.6C
    • /
    • pp.285-293
    • /
    • 2012
  • The surface tension, which is generated in the unsaturated soils, increases the stiffness of the soils. The objective of this study is to estimate the effect of the surface tension, which varies according to the temperature, on the shear wave velocity. Nine specimens, which have the different degree of saturation (0%, 2.5%, 5%, 10%, 20%, 40%, 60%, 80%, 100%), are prepared by using sand-silt mixtures. Experiments are carried out in a nylon cell designed for the measurement of shear waves. A pair of bender elements, which are used for the generation and detection of shear waves, is installed as a cross-hole type. The shear waves are continuously monitored and measured as the temperature of specimens decreases from $15^{\circ}C$ to $1^{\circ}C$. The results show that shear wave velocities of the fully saturated and fully dried specimens change a little bit as the temperatures of specimens decrease. However, the shear wave velocities of the specimens with the degree of saturations of 2.5%, 5%, 10%, 20%, 40%, 60% and 80% continuously increase as temperature decreases from $15^{\circ}C$ to $1^{\circ}C$. Furthermore, a fully saturated specimen is dried at the temperature of $70^{\circ}C$ in order to observe the shear waves according to degree of saturation. The shear wave velocities measured at the temperature of $70^{\circ}C$ are generally lower than those measured at temperature of $15^{\circ}C$. This study demonstrates that the dependence of shear wave velocities on the temperature according to the degree of saturation should be taken into account in both laboratory and field tests.

A Fuzzy Robust Controller with Saturation for Robot Manipulators (로봇 매니퓰레이터의 포화요소를 갖는 퍼지견실 제어)

  • Park, H.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.4
    • /
    • pp.104-109
    • /
    • 1997
  • A robust controller design to corrdinate a robot manipulator under unknown system parameters and bounded disturbance inputs is presented in this paper. Generally, robust controllers require high input torque so that they may face input saturation in actual application due to the power limitation of the actuator. To solve this problem, an improved robust controller with saturated input torque using a fuzzy logic control is proposed. Numerical examples are shown to validate the proposed controller using two degree-of-freedom planar arm.

  • PDF

Prediction method of slope hazards using a decision tree model (의사결정나무모형을 이용한 급경사지재해 예측기법)

  • Song, Young-Suk;Chae, Byung-Gon;Cho, Yong-Chan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1365-1371
    • /
    • 2008
  • Based on the data obtained from field investigation and soil testing to slope hazards occurrence section and non-occurrence section in gneiss area, a prediction technique was developed by the use of a decision tree model. The slope hazards data of Seoul and Kyonggi Province were 104 sections in gneiss area. The number of data applied in developing prediction model was 61 sections except a vacant value. The statistical analyses using the decision tree model were applied to the entrophy index. As the results of analyses, a slope angle, a degree of saturation and an elevation were selected as the classification standard. The prediction model of decision tree using entrophy index is most likely accurate. The classification standard of the selected prediction model is composed of the slope angle, the degree of saturation and the elevation from the first choice stage. The classification standard values of the slope angle, the degree of saturation and elevation are $17.9^{\circ}$, 52.1% and 320m, respectively.

  • PDF

Assessment and Correlation of Saline Soil Characteristics using Electrical Resistivity

  • Mustapha Maliki;Fatima Zohra Hadjadj;Nadia Laredj;Hanifi Missoum
    • Journal of Electrochemical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.205-214
    • /
    • 2023
  • Soil salinity is becoming one of the most devastating environmental hazards over the years. Soil investigation involves fast, low cost and non disturbing methods to measure soil characteristics for both construction projects as well as for agricultural use. The electrical resistivity of saline soils is greatly governed by salt concentration and the presence of moisture in soil matrix. Experimental results of this investigation highlight that there is a significant relationship between the electrical resistivity of soil samples mixed with chloride solutions (NaCl, KCl, and MgCl2) at various concentrations, and soil physical properties. Correlations represented by quadratic functions were obtained between electrical resistivity and soil characteristics, namely, water content, degree of saturation and salt concentration. This research reveals that the obtained correlations between electrical resistivity, salt concentration, water content and degree of saturation are effective for predicting the characteristics of salt affected soils in practice, which constitute a governing element in the assessment of saline lands sustaining infrastructure.