• Title/Summary/Keyword: Degree of imbalance

Search Result 76, Processing Time 0.021 seconds

A Study on the Filling Imbalance in a Geometrically Balanced Injection Mold (기하학적 균형을 갖춘 금형에서 발생하는 성형품의 충전 불균형에 관한 연구)

  • 구양;김병탁;정영득;한성렬;한규택
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.931-937
    • /
    • 2004
  • Simultaneous filling is a goal in plastic injection mold that has multi cavities. The moldings which have not been filled at the same time have undesired faults such as dimension inaccuracy, residual stress, law mechanical strength, etc. The best way to simultaneous fill is to be injected in a geometrically balanced runner system. In a general processing, however, in balanced runner system mold, filling imbalance would be observed in cavities. These phenomena result from molten polymer's characteristics and circumstances in balanced runner. In this study, the degree of filling imbalance (DFI) was defined for showing rate of filling imbalance in geometrically balanced injection mold that has 8 cavities. Before the main experiment, an injection molding simulation was conducted to know a pattern of filling imbalance with Moldflow software. There were somewhat differences between results of experiment and simulation about the filling imbalance. The reason for the difference was that the software have not concerned about a situation in a real flow channel. It was also investigated how the injection speed affected on filling imbalance in the experiment.

Useful Characteristics for Controlling the Cancellation Performance and Center Frequency of a Linearization Loop

  • Kang, Sang-Gee;Hong, Sung-Yong
    • ETRI Journal
    • /
    • v.28 no.2
    • /
    • pp.231-234
    • /
    • 2006
  • The cancellation performance of a linearization loop is limited by the degree of an amplitude imbalance and a phase imbalance. A delay mismatch causes a phase variation as a function of frequency. Therefore, the cancellation performance and linearization bandwidth are limited by a delay mismatch. The expression for the effects of an amplitude imbalance, a phase imbalance, and a delay mismatch on the characteristics of a linearization loop is derived and analyzed. The simulation results are compared with the results obtained by means of using a commercial simulation tool and the exact agreement is reported. The derived equation could be used in designing a linearization loop and predicting the cancellation performance of the linearization loop usefully. Some useful characteristics, known from the simulation results obtained by using the derived equation, of a linearization loop for designing and implementing feedforward amplifiers are described in detail.

  • PDF

On the new mold structure with multi-point gate for filling-balance mold (다점 핀포인트 금형에서 균형충전이 가능한 사출금형 구조)

  • Kwon, Youn-Suk;Jeong, Yeong-Deug
    • Design & Manufacturing
    • /
    • v.2 no.5
    • /
    • pp.25-29
    • /
    • 2008
  • Almost all injection molds have multi-cavity runner system for mass production, which are designed with geometrically balanced runner system in order to accomplish filling balance between cavity to cavity during processing. However, even though geometrically balanced runner is used, filling imbalance have been observed. Filling imbalance could be decreased by modifying processing conditions such as injections rate, mold temperature, injection pressure, melt temperature that are related to shear, viscosity. In this study, a series of experiment was conducted to investigate filling imbalance variation when modifying runner layout and ploymer and to determine which processing condition influences as the primary cause of filling imbalance in geometrically balanced runner system. The filling imbalance was desreased up to result range of $3{\leq}DFI{\leq}8(%)$ by using a new runner system for balanced filling.

  • PDF

On the new mold structure with multi-point gate for filling-balance mold (사출성형시 불균형 충전에 관한 다구찌 실험계획법을 이용한 성형공정의 최적화)

  • Hong, Youn-Suk;Han, Dong-Hyup;Jeong, Yeong Deug
    • Design & Manufacturing
    • /
    • v.1 no.1
    • /
    • pp.13-16
    • /
    • 2007
  • Almost all injection molds have multi-cavity runner system for mass production, which are designed with geometrically balanced runner system in order to accomplish filling balance between cavity to cavity during processing. However, even though geometrically balanced runner is used, filling imbalance have been observed. Filling imbalance could be decreased by modifying processing conditions such as injections rate, mold temperature, injection pressure, melt temperature that are related to shear, viscosity. In this study, a series of experiment was conducted to investigate filling imbalance variation when modifying runner layout and polymer and to determine which processing condition influences as the primary cause of filling imbalance in geometrically balanced runner system.

  • PDF

Study on the Correlation Between the Imbalance of Muscle Strength and the Score of EMG-Biofeedback Game at Ankle Joint in Healthy Adults

  • Ko, Yu-Min;Park, Seol;Lim, Chang-Hun;Lee, Woo-Jin;Park, Ji-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.6
    • /
    • pp.386-391
    • /
    • 2015
  • Purpose: This study investigated whether the strength imbalance between two muscles can affect the score of EMG based biofeedback game, and whether the EMG based biofeedback game score can be used as predictable indicator of the degree of muscle balance alternating the conventional strength measuring equipment. Methods: 40 participated in this study. Biodex was used to measure the peak torque/weight in order to calculate the muscle strength balance index between plantar flexor and dorsiflexor of ankle joint. And muscle balance index (MBI) was calculated. The EMG biofeedback game scores of dorsiflexor and plantar flexor were acquired, so that the EMG electrodes were attached at tibialis anterior and gastrocnemius. The relationship between the game score and the muscle balance index were analyzed. Results: There was negative correlation between the muscle balance index between plantar flexor and dorsiflexor and the peak torque/weight of plantar flexor (r=-0.70). And there was negative correlation between the muscle balance index between plantar flexor and dorsiflexor and the game score of plantar flexor (r=-0.83). Conclusion: The EMG biofeedback game score had significant relationship with muscle imbalance at ankle joint, so it seems that the game score can be used for predicting the degree of muscle imbalance as a parameter.

The Pressure and Degree of Filling Balance between Cavity to Cavity in Multi-Cavity Injection Mold (다수 캐비티 금형에서 캐비티 간의 압력과 균형충전도)

  • Noh, Byeong-Su;Park, Tae-Won;Jeong, Yeong-Deug
    • Design & Manufacturing
    • /
    • v.2 no.6
    • /
    • pp.33-37
    • /
    • 2008
  • Almost all injection molds have multi-cavity, which are designed with geometrically balanced runner system in order to made filling balance between cavity to cavity during injection molding. However, filling imbalance has been existed in the geometrically balanced runner system. In this study, we made an experiment and investigated that are filling balanced according to material. Also, in case of filling imbalance was occurred, we conducted experiments in order to find out difference of cavity pressure with cavity pressure sensor. When filling imbalance was occurred between cavity to cavity, we investigated the filling imbalance and pressure differences by computer-aided engineering(CAE).

  • PDF

The Filling Imbalance in Multi-Cavity Injection Molds with Unary Branch Type Runner Lay-out (편측 분기형 러너 배열을 가진 다수 캐비티 사출금형에서의 충전 불균형도)

  • 강철민;정영득
    • Transactions of Materials Processing
    • /
    • v.13 no.7
    • /
    • pp.580-585
    • /
    • 2004
  • Almost all injection molds have multi-cavity runner system fur productivity and are designed with geometrically balanced runner system in order to minimize filling imbalance between cavity to cavity during processing. However, filling imbalances have been observed though geometrically balanced runner lay-out. Generally, these filling imbalances are due to thermal unbalance, viscosity, characteristic of polymers and so on. These kinds of filling imbalances have already been reported by Beaumont since 1997, but his research has mainly focused on filling imbalance at binary runner. In this study, we conducted an experimental study about the filling imbalances in unary branch runner as well as binary branch runner and inquired into the causes of filling imbalances. The results could be summarized as fellowing: Filling imbalances existed in multi-cavity mold with unary branch runner, it could be decreased by optimizing processing condition such as increasing injection rate, and it is almost proportion to each polymer's temperature sensibility.

Degree of Filling Balance according to Runner Shapes in Injection Mold (사출금형의 러너시스템 형상에 따른 균형 충전도)

  • Han, Dong-Yeop;Jeong, Yeong-Deug
    • Design & Manufacturing
    • /
    • v.6 no.1
    • /
    • pp.52-57
    • /
    • 2012
  • Aspect of filling imbalance that is originated from imbalanced share rate in runner is changed by material property, runner layout that are factors of changing viscosity and by injection pressure, injection speed, melt temperature and mold temperature that are injection conditions. In this paper, we made a study of runner system that is one of factor of filling imbalance and Sharp Conner Effect and Groove Corner Effect that are recently released. The study are showed that filling rate of between inside and outside cavity was influenced on shape of runner. Also, we suggested runner system for filling imbalance by adapting the two effects at multi cavity of unary branch type and theoretical investigated flow in the Shrap Conner runner type.

  • PDF

Which Information is Commonly Used for Patients with Stroke at Rehabilitation Settings?

  • Lee, Haejung;Song, Jumin
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.6
    • /
    • pp.392-399
    • /
    • 2015
  • Purpose: This study investigated whether the strength imbalance between two muscles can affect the score of EMG based biofeedback game, and whether the EMG based biofeedback game score can be used as predictable indicator of the degree of muscle balance alternating the conventional strength measuring equipment. Methods: 40 participated in this study. Biodex was used to measure the peak torque/weight in order to calculate the muscle strength balance index between plantar flexor and dorsiflexor of ankle joint. And muscle balance index (MBI) was calculated. The EMG biofeedback game scores of dorsiflexor and plantar flexor were acquired, so that the EMG electrodes were attached at tibialis anterior and gastrocnemius. The relationship between the game score and the muscle balance index were analyzed. Results: There was negative correlation between the muscle balance index between plantar flexor and dorsiflexor and the peak torque/weight of plantar flexor (r=-0.70). And there was negative correlation between the muscle balance index between plantar flexor and dorsiflexor and the game score of plantar flexor (r=-0.83). Conclusion: The EMG biofeedback game score had significant relationship with muscle imbalance at ankle joint, so it seems that the game score can be used for predicting the degree of muscle imbalance as a parameter.

Degree of Filling Balance according to Runner Shapes in Injection Mold (사출금형의 러너시스템 형상에 따른 균형 충전도)

  • Han, Dong-Yeop;Jeong, Yeong-Deug
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.10
    • /
    • pp.144-149
    • /
    • 2008
  • Configuration of filling imbalance which is originated from imbalanced share rate of melt on runner is changed by runner layout, runner shape, material property, injection pressure, injection speed, melt temperature and mold temperature. In this paper, we conducted a study of runner layout and shape that are main factors of filling imbalance. Other factors such as the sharp corner effect and the groove corner effect are recently released were also considered. The results of study are showed that filling rate of between inside and outside cavity was influenced on shape of runner. Especially, this study suggests a new runner system for filling balance by adapting the two effects of unary branch type runner at multi cavity mold and theoretical investigated flow in the sharp corner type runner.