• Title/Summary/Keyword: Degree of acquisition

Search Result 185, Processing Time 0.032 seconds

Demand and Awareness of Dental Hygienists for Academic Credit Bank System According to Different Regions (지역별 치과위생사의 학점은행제에 대한 인식 및 요구)

  • Yang, Seung-Kyeong;Kim, Eun-Hee
    • Journal of dental hygiene science
    • /
    • v.8 no.4
    • /
    • pp.313-322
    • /
    • 2008
  • The purpose of this study was to examine the awareness of dental hygienists in different regions about credit bank system and their needs for that. The subjects in this study were 312 dental hygienists in dental hospitals and clinics in Seoul, Gyeonggi province, metropolitan cities, Gangweon province and Gyeongsang province. After a survey was conducted in 2008, the collected data were analyzed with SPSS 11.5 program. The findings of the study were as follows: 1. In regard to perception of the credit bank system, 68.3 percent of the dental hygienists were cognizant of that. The dental hygienists from most of the geographic areas were aware of it, but all the forty three dental hygienists from Gangweon province who accounted for 13.8 percent didn't know about that. As for media by which they acquired information on that, many of the dental hygienists learned about it from their acquaintances (46.2%), but that was not the case for the dental hygienists from Seoul and Gyeonggi province. 2. As for expectations for the credit bank system, those from Gyeongsang province had the greatest expectations for that in six out of nine items, which included academic or job performance improvement, acquisition of credits, degree or certificates and access to new technology. 3. Concerning educational spending on the credit bank system, 18.9 percent and 8.7 percent from Seoul/Gyeonggi province and Gangweon province spent less than 30 thousand won, and 19.9 percent from the metropolitan cities spent 30 thousand to less than 50 thousand won. 4. As for the importance of the categories of their major in the credit bank system, those from Gangweon province attached the most importance to oral health education ($3.56{\pm}1.259$), and the dental hygienists from the metropolitan cities put the most stress on preventive treatment ($3.64{\pm}1.191$).

  • PDF

Effects of Iterative Reconstruction Algorithm, Automatic Exposure Control on Image Quality, and Radiation Dose: Phantom Experiments with Coronary CT Angiography Protocols (반복적 재구성 알고리즘과 관전류 자동 노출 조정 기법의 CT 영상 화질과 선량에 미치는 영향: 관상동맥 CT 조영 영상 프로토콜 기반의 팬텀 실험)

  • Ha, Seongmin;Jung, Sunghee;Chang, Hyuk-Jae;Park, Eun-Ah;Shim, Hackjoon
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.28-35
    • /
    • 2015
  • In this study, we investigated the effects of an iterative reconstruction algorithm and an automatic exposure control (AEC) technique on image quality and radiation dose through phantom experiments with coronary computed tomography (CT) angiography protocols. We scanned the AAPM CT performance phantom using 320 multi-detector-row CT. At the tube voltages of 80, 100, and 120 kVp, the scanning was repeated with two settings of the AEC technique, i.e., with the target standard deviations (SD) values of 33 (the higher tube current) and 44 (the lower tube current). The scanned projection data were reconstructed also in two ways, with the filtered back projection (FBP) and with the iterative reconstruction technique (AIDR-3D). The image quality was evaluated quantitatively with the noise standard deviation, modulation transfer function, and the contrast to noise ratio (CNR). More specifically, we analyzed the influences of selection of a tube voltage and a reconstruction algorithm on tube current modulation and consequently on radiation dose. Reduction of image noise by the iterative reconstruction algorithm compared with the FBP was revealed eminently, especially with the lower tube current protocols, i.e., it was decreased by 46% and 38%, when the AEC was established with the lower dose (the target SD=44) and the higher dose (the target SD=33), respectively. As a side effect of iterative reconstruction, the spatial resolution was decreased by a degree that could not mar the remarkable gains in terms of noise reduction. Consequently, if coronary CT angiogprahy is scanned and reconstructed using both the automatic exposure control and iterative reconstruction techniques, it is anticipated that, in comparison with a conventional acquisition method, image noise can be reduced significantly with slight decrease in spatial resolution, implying clinical advantages of radiation dose reduction, still being faithful to the ALARA principle.

Participant Characteristic and Educational Effects for Cyber Agricultural Technology Training Courses (사이버농업기술교육 참가자의 특성과 교육효과)

  • Kang, Dae-Koo
    • Journal of Agricultural Extension & Community Development
    • /
    • v.21 no.1
    • /
    • pp.35-82
    • /
    • 2014
  • It was main objectives to find the learners characteristics and educational effects of cyber agricultural technology courses in RDA. For the research, it was followed by literature reviews and internet based survey methods. In internet based survey, two staged stratified sampling method was adopted from cyber training members database in RDA along with some key word as open course or certificate course, and enrollment years. Instrument was composed through literature reviews about cyber education effects and educational effect factors. And learner characteristics items were added in survey documents. It was sent to sampled persons by e-mail and 316 data was returned via google survey systems. Through the data cleaning, 303 data were analysed by chi-square, t-test and F-test. It's significance level was .05. The results of the research were as followed; First, the respondent was composed of mainly man(77.9%), and monthly income group was mainly 2,000,000 or 3,000,000 won(24%), bachelor degree(48%), fifty or forty age group was shared to 75%, and their job was changed after learning(12.2%). So major respondents' job was not changed. Their major was not mainly agriculture. Learners' learning style were composed of two or more types as concrete-sequential, mixing, abstract-random, so e-learning course should be developed for the students' type. Second, it was attended at 3.2 days a week, 53.53 minutes a class, totally 172.63 minutes a week. They were very eager or generally eager to study, and attended two or more subjects. The cyber education motives was for farming knowledge, personal competency development, job performance enlarging. They selected subjects along with their interest. A subject person couldn't choose more subjects for little time, others, non interesting subject, but more subject persons were for job performance benefits and previous subjects effectiveness. Most learner was finished their subject, but a fourth was not finished for busy (26.7%). And their entrying behavior was not enough to learn e-course and computer or internet using ability was middle level as software using. And they thought RDA cyber course was comfort in non time or space limit, knowledge acquisition, and personal competency development. Cyber learning group was composed of open course only (12.5%), certificate only(25.7%), both(36.3%). Third, satisfaction and academic achievement of e-learning learners were good, and educational service offering for doing job in learning application category was good, but effect of cyber education was not good, especially, agricultural income increasing was not good because major learner group was not farmer, so they couldn't apply their knowledge to farming. And content structure and design, content comprehension, content amount were good. The more learning subject group responded to good in effects, and both open course and certificate course group satisfied more than open course only group. Based on the results, recommendation was offered as cyber course specialization before main course in RDA training system, support staff and faculty enlargement, building blended learning system with local RDA office, introducing cyber tutor system.

Effect of the Angle of Ventricular Septal Wall on Left Anterior Oblique View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 심실중격 각도에 따른 좌전사위상 변화에 대한 연구)

  • You, Yeon Wook;Lee, Chung Wun;Seo, Yeong Deok;Choi, Ho Yong;Kim, Yun Cheol;Kim, Yong Geun;Won, Woo Jae;Bang, Ji-In;Lee, Soo Jin;Kim, Tae-Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.13-19
    • /
    • 2016
  • Purpose In order to calculate the left ventricular ejection fraction (LVEF) accurately, it is important to acquire the best septal view of left ventricle in the multi-gated cardiac blood pool scan (GBP). This study aims to acquire the best septal view by measuring angle of ventricular septal wall (${\theta}$) using enhanced CT scan and compare with conventional method using left anterior oblique (LAO) 45 view. Materials and Methods From March to July in 2015, we analyzed the 253 patients who underwent both enhanced chest CT and GBP scan in the department of nuclear medicine at National Cancer Center. Angle (${\theta}$) between ventricular septum and imaginary midline was measured in transverse image of enhanced chest CT scan, and the patients whose difference between the angle of ${\theta}$ and 45 degree was more than 10 degrees were included. GBP scan was acquired using both LAO 45 and LAO ${\theta}$ views, and LVEFs measured by automated and manual region of interest (Auto-ROI and Manual-ROI) modes respectively were analyzed. Results $Mean{\pm}SD$ of ${\theta}$ on total 253 patients was $37.0{\pm}8.5^{\circ}$. Among them, the patients whose difference between 45 and ${\theta}$ degrees were more than ${\pm}10$ degrees were 88 patients ($29.3{\pm}6.1^{\circ}$). In Auto-ROI mode, there was statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=62.0{\pm}6.6%$ vs. LVEF ${\theta}=64.0{\pm}5.6%$; P = 0.001). In Manual-ROI mode, there was also statistically significant difference between LAO 45 and LAO ${\theta}$ (LVEF $45=66.7{\pm}7.2%$ vs. LVEF ${\theta}=69.0{\pm}6.4%$; P < 0.001). Intraclass correlation coefficients of both methods were more than 95%. In case of comparison between Auto-ROI and Manual ROI of each LAO 45 and LAO ${\theta}$, there was no significant difference statistically. Conclusion We could measure the angle of ventricular septal wall accurately by using transverse image of enhanced chest CT and applied to LAO acquisition in the GBP scan. It might be the alternative method to acquire the best septal view of LAO effectively. We could notify significant difference between conventional LAO 45 and LAO ${\theta}$ view.

  • PDF

Analysis of the Range Verification of Proton using PET-CT (Off-line PET-CT를 이용한 양성자치료에서의 Range 검증)

  • Jang, Joon Young;Hong, Gun Chul;Park, Sey Joon;Park, Yong Chul;Choi, Byung Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.101-108
    • /
    • 2017
  • Purpose: The proton used in proton therapy has a characteristic of giving a small dose to the normal tissue in front of the tumor site while forming a Bragg peak at the cancer tissue site and giving up the maximum dose and disappearing immediately. It is very important to verify the proton arrival position. In this study, we used the off-line PET CT method to measure the distribution of positron emitted from nucleons such as 11C (half-life = 20 min), 150 (half-life = 2 min) and 13N The range and distal falloff point of the proton were verified by measurement. Materials and Methods: In the IEC 2001 Body Phantom, 37 mm, 28 mm, and 22 mm spheres were inserted. The phantom was filled with water to obtain a CT image for each sphere size. To verify the proton range and distal falloff points, As a treatment planning system, SOBP were set at 46 mm on 37 mm sphere, 37 mm on 28 mm, and 33 mm on 22 mm sphere for each sphere size. The proton was scanned in the same center with a single beam of Gantry 0 degree by the scanning method. The phantom was scanned using PET-CT equipment. In the PET-CT image acquisition method, 50 images were acquired per minute, four ROIs including the spheres in the phantom were set, and 10 images were reconstructed. The activity profile according to the depth was compared to the dose profile according to the sphere size established in the treatment plan Results: The PET-CT activity profile decreased rapidly at the distal falloff position in the 37 mm, 28 mm, and 22 mm spheres as well as the dose profile. However, in the SOBP section, which is a range for evaluating the range, the results in the proximal part of the activity profile are different from those of the dose profile, and the distal falloff position is compared with the proton therapy plan and PET-CT As a result, the maximum difference of 1.4 mm at the 50 % point of the Max dose, 1.1 mm at the 45 % point at the 28 mm sphere, and the difference at the 22 mm sphere at the maximum point of 1.2 mm were all less than 1.5 mm in the 37 mm sphere. Conclusion: To maximize the advantages of proton therapy, it is very important to verify the range of the proton beam. In this study, the proton range was confirmed by the SOBP and the distal falloff position of the proton beam using PET-CT. As a result, the difference of the distally falloff position between the activity distribution measured by PET-CT and the proton therapy plan was 1.4 mm, respectively. This may be used as a reference for the dose margin applied in the proton therapy plan.

  • PDF