• Title/Summary/Keyword: Degraded Control

Search Result 408, Processing Time 0.022 seconds

The Performance Improvement using Rate Control in End-to-End Network Systems (종단간 네트워크 시스템에서 승인 압축 비율 제어를 이용한 TCP 성능 개선)

  • Kim, Gwang-Jun;Yoon, Chan-Ho;Kim, Chun-Suk
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.1
    • /
    • pp.45-57
    • /
    • 2005
  • In this paper, we extend the performance of bidirectional TCP connection over end-to-end network that uses transfer rate-based flow and congestion control. The sharing of a common buffer by TCP packets and acknowledgement has been known to result in an effect called ack compression, where acks of a connection arrive at the source bunched together, resulting in unfairness and degraded throughput. The degradation in throughput due to bidirectional traffic can be significant. Even in the simple case of symmetrical connections with adequate window size, the connection efficiency is improved about 20% for three levels of background traffic 2.5Mbps, 5.0Mbps and 7.5Mbps. Otherwise, the throughput of jitter is reduced about 50% because round trip delay time is smaller between source node and destination node. Also, we show that throughput curve is improved with connection rate algorithm which is proposed for TCP congetion avoidance as a function of aggressiveness threshold for three levels of background traffic 2.5Mbps, 5Mbps and 7.5Mbps. By analyzing the periodic bursty behavior of the source IP queue, we derive estimated for the maximum queue size and arrive at a simple predictor for the degraded throughput, applicable for relatively general situations.

Trust-based Relay Selection in Relay-based Networks

  • Wu, Di;Zhu, Gang;Zhu, Li;Ai, Bo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.10
    • /
    • pp.2587-2600
    • /
    • 2012
  • It has been demonstrated that choosing an appropriate relay node can improve the transmission rate for the system. However, such system improvement brought by the relay selection may be degraded with the presence of the malicious relay nodes, which are selected but refuse to cooperate for transmissions deliberately. In this paper, we formulate the relay selection issue as a restless bandit problem with the objective to maximize the average rate, while considering the credibility of each relay node, which may be different at each time instant. Then the optimization problem is solved by using the priority-index heuristic method effectively. Furthermore, a low complexity algorithm is offered in order to facilitate the practical implementations. Simulation results are conducted to demonstrate the effectiveness of the proposed trust-based relay selection scheme.

Performance of PN Code Tracking Loop for a DS/CDMA System with Imperfect Power Control and Shadowing

  • Kim, Jin-Young
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.501-504
    • /
    • 2000
  • In this paper, performance of a pseudonoise (PN) code tracking loop is analyzed and simulated for a direct-sequence/code-division multiple access ( DS/CDMA) system with imperfect power control in a multipath fading channel. A noncoherent first-order delay-locked loop (DLL) is considered as a PN code tracking loop. Power control error is modeled as a log-normally distributed random variable. From the simulation results, it is shown that for smaller discriminator offset, tracking jitter performance is improved while MTLL performance is degraded. It is shown that large power control error and heavy shadowing substantially degrade the PN tracking performance. The analysis in this paper can be applicable to design of PN code tracking loop for a DS/CDMA system.

  • PDF

Study on the Fuzzy Control of CO2 Heat Pump System (이산화탄소 열펌프 시스템의 퍼지 제어에 관한 연구)

  • Lee, Jae-Seung;Han, Yung-Hee;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.513-518
    • /
    • 2008
  • In the air-conditioning and refrigeration industry, the efforts to protect the environment have been made. One of them is to use carbon dioxide as an alternative refrigerant, however, several researches have shown that the transcritical heat pump system using $CO_2$ has relatively lower efficiency resulting in a degraded steady-state system performance. Capacity control with fuzzy controller was carried out for $CO_2$ heat pump system. Evaporator secondary fluid outlet temperature was suggested for the control variable of compressor speed modulation.

  • PDF

On-line control of product uniformity for quality improvement (품질향상을 위한 제품 균일성의 On-Line 제어)

  • Ha, Sungdo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.3
    • /
    • pp.70-79
    • /
    • 1996
  • In off-line process optimization, process parameters are controlled such that the process is robust against changes in equipment conditions and incoming materials. The off-line methods, however, are not effective when the changes are so large that process parameters need to be adjusted. On-line control can respond to such large changes, but process uniformity has not been controlled on-line due to the difficulties in modeling. This paper is aimed at developing a new on-line control methodology where the uniformity is controlled effectively. The process variability is categorized based on the physical considerations, and the process parameters are classi- fied considering their effects on the categorized process variabilities. On-line control is performed with the properly selected process parameters so that robustness may not be degraded. The developed methodology is applied to the single wafer plasma etching processes, which resulted in both higher within-a-wafer uniformity and compens- ation of the incoming material non-uniformity.

  • PDF

Biological Pretreatment of Softwood Pinus densiflora by Three White Rot Fungi

  • Lee, Jae-Won;Gwak, Ki-Seob;Park, Jun-Yeong;Park, Mi-Jin;Choi, Don-Ha;Kwon, Mi;Choi, In-Gyu
    • Journal of Microbiology
    • /
    • v.45 no.6
    • /
    • pp.485-491
    • /
    • 2007
  • The effects of biological pretreatment on the Japanese red pine Pinus densiflora, was evaluated after exposure to three white rot fungi Ceriporia lacerata, Stereum hirsutum, and Polyporus brumalis. Change in chemical composition, structural modification, and their susceptibility to enzymatic saccharification in the degraded wood were analyzed. Of the three white rot fungi tested, S. hirsutum selectively degraded the lignin of this sortwood rather than the holocellulose component. After eight weeks of pretreatment with S. hirsutum, total weight loss was 10.7%, while lignin loss was the highest at 14.52% among the tested samples. However, holocellulose loss was lower at 7.81 % compared to those of C. lacerata and P. brumalis. Extracelluar enzymes from S. hirsutum showed higher activity of ligninase and lower activity of cellulase than those from other white rot fungi. Thus, total weight loss and changes in chemical composition of the Japanese red pine was well correlated with the enzyme activities related with lignin- and cellulose degradation in these fungi. Based on the data obtained from analysis of physical characterization of degraded wood by X-ray Diffractometry (XRD) and pore size distribution, S. hirsutum was considered as an effective potential fungus for biological pretreatment. In particular, the increase of available pore size of over 120 nm in pretreated wood powder with S. hirsutum made enzymes accessible for further enzymatic saccharification. When Japanese red pine chips treated with S. hirsutum were enzymatically saccharified using commercial enzymes (Cellulclast 1.5 L and Novozyme 188), sugar yield was greatly increased (21.01 %) compared to non-pre treated control samples, indicating that white rot fungus S. hirsutum provides an effective process in increasing sugar yield from woody biomass.

Fuel Management and Experimental Wildfire Effects on Forest Structure, Tree Mortality and Soil Chemistry in Tropical Dry Forests in Ghana

  • Barnes, Victor R;Swaine, Mike D;Pinard, Michelle A;Kyereh, Boateng
    • Journal of Forest and Environmental Science
    • /
    • v.33 no.3
    • /
    • pp.172-186
    • /
    • 2017
  • The effects of application of fuel-reduction treatment in wildfire management has not been tested in dry forests of Ghana. Therefore, the short-term ecological effects of prescribed burning and hand thinning treatments followed by experimental wildfire were investigated in degraded forests and Tectona grandis forest plantations in two forest reserves of different levels of dryness in Ghana. The results showed that more trees were killed in prescribed burning (average of 41% in degraded forest and 18% in plantations) than hand thinning (7.2% in degraded forests and 8% in plantation). More tree seedlings were also killed in prescribed burning (72%) than hand thinning (47%). The mortality of trees and seedlings were greater in Worobong South forest, a less dry forest reserve than the Afram Headwaters forest, a drier forest reserve. Fuel treatment especially prescribed burning compared to the control reduced wildfire effects on forest canopy particularly in the less dry forest and tree mortality especially in the drier forest. Prescribed burning temporarily increased pH, exchangeable potassium (52%) and available phosphorus (82%) in the surface soils of the entire plots. The two fuel treatment methods did not have much influence on basal area, organic matter and total nitrogen. Nevertheless, they were able to reduce the adverse wildfire effects on soil pH, exchangeable potassium, available phosphorus, organic matter and total nitrogen concentrations. Fuel treatments therefore have potential application in dry forest management in Ghana due to their ability to retain important forest ecological traits after a wildfire incidence.

An Improved Stationary Frame-based Digital Current Control Scheme for a PM Synchronous Motor

  • Kim Kyeong-Hwa;Youn Myung-Joong
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.174-178
    • /
    • 2001
  • An improved stationary frame-based digital current control technique for a permanent magnet (PM) synchronous motor is presented. Generally, the stationary frame current controller is known to provide the advantage of a simple implementation. However, there are some unavoidable limitations such as a steady-state error and a phase delay in the steady-state. On the other hand, in the synchronous frame current regulator, the regulated currents are dc quantities and a zero steady-state error can be obtained through the integral control. However, the need to transform the signals between the stationary and synchronous frames makes the implementation of a synchronous frame regulator complex. Although the PI controller in the stationary frame gives a steady-state error and a phase delay, the control performance can be greatly improved by employing the exact decoupling control inputs for the back EMF, resulting in an ideal steady-state control characteristics irrespective of an operating condition as in the synchronous PI decoupling controller. However, its steady-state response may be degraded due to the inexact cancellation inputs under the parameter variations. To improve the control performance in the stationary frame, the disturbance is estimated using the time delay control. The proposed scheme is implemented on a PM synchronous motor using DSP TMS320C31 and the effectiveness is verified through the comparative simulations and experiments.

  • PDF

An Improved Stationary Frame-based Digital Current Control Scheme for a PM Synchronous Motor

  • Kim, Kyeong-Hwa;Young, Myung-Joong
    • Journal of Power Electronics
    • /
    • v.1 no.2
    • /
    • pp.88-98
    • /
    • 2001
  • An improved stationary frame-based digital current control technique for a permanent magnet(PM) synchronous motor is presented. Generally, the stationary frame current controller is known to provide the advantage of a simple implementation. However, there are some unavoidable limitations such as a steady-state error and a phase delay in the steady-state. On the other hand, in the synchronous frame current regulator the regulated currents are dc quantities and a zero steady-state error can be obtained through the integral control. However, the need to transform the signals between the stationary and synchronous frames makes the implementation of a synchronous frame regulator complex. Although the PI controller in the stationary frame gives a steady-state error and a phase delay, the control performance can be greatly improved by employing the exact decoupling control inputs for the back EMF., resulting in an ideal steady-state control characteristics irrespective of an operating condition as in the synchronous PI decoupling controller. However, its steady-state response may be degraded due to the inexact cancellation inputs under the parameter variations. To improve the control performance in the stationary frame, the disturbance is estimated using the time delay control. The proposed scheme is implemented on a PM synchronous motor using DSP TMS320C31 and the effectiveness is verified through the comparative simulations and experiments.

  • PDF

Route Stability of Mobile Ad Hoc Network Based on Proximity and Mobility (근접성과 이동성에 기초한 Ad Hoc망의 경로안정도)

  • 안성범;안홍영
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.39-42
    • /
    • 2003
  • Due to the highly dynamic topology and absence of any fixed infrastructure, stability of selected path in Ad Hoc Networks is of prime importance. The frequent route failure and high control overhead in routing protocol consumes system resources and lead to degraded system performance. In this paper we present route stability metrics reflectting relative position and velocity of nodes, which help determine a stable route.

  • PDF