착상과 제상이 냉동장치의 운전특성에 미치는 영향 (Effect of Frost and Defrost on the Operating Characteristics of Refrigeration System)

  • 김재돌
    • 동력기계공학회지
    • /
    • 제14권4호
    • /
    • pp.5-10
    • /
    • 2010
  • This study was investigated the effect on operating characteristics of apparatus according to frosting and defrosting to develop of new defrosting equipment. The results showed as following. Frost was almost removed using the defrosting equipment with roll brush type that defrosting is possible under operating condition. Also, the temperature of compressor inlet, evaporator inlet and outlet showed higher value because of heat transfer resistance of cooling pipe frost comparing with defrosting condition. And the compressor work showed 10% lower and COP was presented 24% higher values than defrosting condition. Therefore, defrosting for cooling coil of refrigeration and low temperature storage was effected on operation and performance characteristics of equipment. This highly effects on real refrigeration apparatus which is operated in year-around.

광센서를 이용한 제상제어 방법에 대한 연구 (A Study of the Defrosting Control in the Application of Photoelectric Sensors)

  • 전창덕
    • 설비공학논문집
    • /
    • 제29권4호
    • /
    • pp.167-174
    • /
    • 2017
  • This study attempted to investigate the value of photoelectric sensors in terms of a defrost-control method. Tests were conducted in a calorimeter room under the heating with the defrost-performance test conditions described in KS C 9306. Accordingly, the photoelectric technology is a competitive defrost-control method that can precisely control the operational defrost cycle using the output voltages that are proportional to the frost height. The heating period is gradually reduced because the complex defrost-control method, for which the sensors initiate the defrosting process and the defrosting process is terminated by the time parameter, could not adjust the net defrosting time by itself. Therefore, a complex defrost-control method, for which the photoelectric sensors start the defrosting process and it is terminated by the temperature parameter, is preferred because of the adjustment of the net defrosting time. Regardless of the defrost-control method, the first defrosting cycle is activated earlier than the times that are determined in the second and third cycles and so on, because the first operation cycle can decide the characteristics of the subsequent cycle.

냉장고 소비전력 저감을 위한 착상감지센서의 응용 연구 (Application of Frost Detecting Sensors in Refrigerators to Reduce Energy Consumption)

  • 성창용;나승유;이희영
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(5)
    • /
    • pp.147-150
    • /
    • 2000
  • Manual and predictive defrosting method is used in current refrigerators, which have several problems in terms of energy consumption and efficiency. fuming the defrosting system on by the amount of frost remains to be an important problem which has to be improved by refrigerator manufacturers. The sensing of the amount of frost by FDS(Frost Detecting Sensor) and its proper mounting point are investigated in the paper. Also the realization of actual defrosting system through experiments of operation, energy consumption and sensing mechanism is presented.

  • PDF

공기분사식 제상장치 개발에 관한 실험적 연구 (Experimental Study for Development of Air Eject Defrost Equipment)

  • 한인근;김창영;김재돌;윤정인
    • 대한기계학회논문집B
    • /
    • 제25권3호
    • /
    • pp.277-284
    • /
    • 2001
  • One of the problems in a refrigerator operation is the frost formation on a cold surface of the evaporator. The frost layer is formed by the sublimation of water vapor when the surface temperature is below the freezing point. This frost layer is usually porous and formed on the cold surface of the evaporator. The frost layer on the surface of a evaporator will make side effect such as thermal resistance. However, these important factors have not been used in determining the defrosting period. Therefore, the proper defrosting operation period based on the new defrosting method is very important, and make a comparison between conventional method like electric defrost and new method in compression work, evaporation pressure, evaporation temperature.

저온창고에서 냉동기 응축폐열을 이용한 제상시스템 성능평가 (Performance Evaluation of a Defrosting System Using the Condensation Heat of a Refrigerator in Cold Storage)

  • 박천완;이동규;임관빈;강채동
    • 설비공학논문집
    • /
    • 제26권2호
    • /
    • pp.72-78
    • /
    • 2014
  • In a cold chain, the refrigerator is also employed for defrosting, by using an electric heater, which consumes 15% of the power for the system operation. In this study, the condensation heat of the refrigerant was suggested as the heat source of defrosting heat, instead of that from an electric defrost heater. The heat for defrosting was stored to a phase change material (PCM, NMP : $52^{\circ}C$) in thermal storage, and was periodically supplied to the evaporator by a circulation loop of brine. As a result, a defrost time by the PCM was obtained that was less than or equal to that by the electric heater. Moreover, power consumption during defrosting was saved by up to 99% of that of the electric heater.

PCM 유닛을 적용한 공기 열원 히트펌프의 연속난방 성능 특성에 관한 실험적 연구 (An Experimental Study on the Heat Transfer Performance of an Air-Source Heat Pump Using a PCM Unit for Continuous Heating)

  • 장민;정동일;정종호;김용찬
    • 설비공학논문집
    • /
    • 제27권10호
    • /
    • pp.537-543
    • /
    • 2015
  • Air-source heat pumps are widely used in winter as heating units due to their higher efficiency compared to electronic heaters or gas fired equipment. However, the air-source heat pump can cause discomfort during periodic defrosting operations. In this study, a PCM unit for continuous heating was adopted to solve this problem. The PCM unit consisted of a PCM, a heat exchanger, and control valves. It was installed between the outdoor and indoor units. The performance of the proposed system was measured during both defrosting and heating operations. The indoor unit showed an average leaving temperature of $26^{\circ}C$ after adopting the PCM unit for continuous heating during the defrosting operation.

착상조건에서 연속난방이 가능한 히트펌프 성능 향상 기술 (Performance Improvement Technology on a Continuous Heating Heat Pump at Frost Condition)

  • 전창덕
    • 한국산학기술학회논문지
    • /
    • 제14권2호
    • /
    • pp.573-577
    • /
    • 2013
  • 히트펌프는 에너지 효율이 높고, 지열, 폐열, 공기열 등 다양한 열원 사용이 가능하기 때문에 보급이 빠르게 확대되고 있다. 공기를 열원으로 이용하는 공랭식 히트펌프의 경우는 실외기 표면에 형성되는 서리를 제거하기 위해 제상운전이 요구된다. 일반적으로 사용하는 역사이클(reverse cycle) 제상운전 방법은 연속난방이 불가능하며 이로 인해 성능계수가 감소하는 원인이 된다. 본 연구에서는 실외기 코일용 휜-관 열교환기를 3열로 구성하고 난방과 제상이동시에 가능하도록 일정시간 간격으로 열교환기의 한 개의 열을 응축기로, 나머지 열은 증발기로 교번 운전을 수행하여 KS C 9306에 규정된 제상-난방 시험조건(건구온도 $2^{\circ}C$, 습구온도 $1^{\circ}C$)에서 최소 180분 이상 연속난방이 가능함을 실증하였으며 역사이클 제상방법을 사용하는 일반적인 히트펌프 대비 COP가 약 20% 향상됨을 알 수 있었다.

쇼케이스의 현장 데이터 측정 및 분석 (Measurement and Analysis of Showcase Field Data)

  • 신유환;오왕규;박기호;김영일;신영기
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.436-443
    • /
    • 2005
  • Experimental study was performed to understand the operation of an on-site showcase working in a super discount store. Inlet and outlet temperatures of evaporator, condenser, expansion valve and compressor were measured for both air and refrigerant sides. Electric power consumption of compressors, defrosting heaters, cooling water pumps and etc. were measured. The operating characteristics of the showcase system under various working conditions were analyzed and discussed. During the defrosting process, the air temperature inside the showcase increased to $15^{\circ}C$, which gave harmful effect to the frozen food. The collected data will serve as valuable information for diagnosing and improving the performance of showcases.

심야전력을 이용한 Cascade Heat Pump Cycle의 운전결과 분석 (Analysis on Cascade Cycle Heat Pump Application as Night Storage Heater)

  • 정훈;황성욱;이철희
    • 한국기계기술학회지
    • /
    • 제13권1호
    • /
    • pp.113-118
    • /
    • 2011
  • To analyze and verify the effect of replacing thermal storage heater by a cascade cycle heat pump using midnight electricity was installed and tested at a customer's house in Wonju, Korea. The electric night storage heater is consist of 30kW electric heater and 2,700 liters of thermal storage water tank to supply hot water for warming house floor. The power for electric heater was cut off and hot water was only generated by cascade cycle heat pump. Current thermal storage water tank was not eliminated and electric heater wiring was modified. Some operation logic of the heat pump was also modified for proper operation. The required capacity of the heat pump and hot water temperature for given warming condition were estimated. The estimated capacity of heat pump was about 19kW and estimated hot water temperature for proper heating was at least $75^{\circ}C$.

플레이트 휜 코일형 증발기의 착상에 관한 기초 실험 (Basic Experiment on Frost of Plate Fin Coil Evaporator)

  • 백승문;김창영;한인근;김재돌;윤정인
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1999년도 추계 학술발표회 논문집
    • /
    • pp.211-216
    • /
    • 1999
  • One of the problems in a refrigerator operation is the frost formation on a cold surface of the evaporator. The frost layer is formed by the sublimation of water vapor when the surface temperature is below the freezing point. This frost layer is usually porous and formed on the cold surface of the evaporator. The frost layer on the surface of a evaporator will make side effect such as thermal resistance. However, these important factors have not been used in determining the defrosting period. In this report, a prediction taking into account the change of the fin efficiency due to the growth of the frost layer.

  • PDF