• Title/Summary/Keyword: Defense Acquisition Program

Search Result 164, Processing Time 0.019 seconds

A case study on calibration of computational model for a reasonable cost estimation of missile development program (A case of guidance & control system of X missile) (유도무기 연구개발사업의 합리적인 비용 추정을 위한 전산모델 보정방안 사례 연구 (X 유도무기 유도조종장치 사례를 중심으로))

  • Park, Chung-Hee
    • Journal of Digital Convergence
    • /
    • v.12 no.5
    • /
    • pp.139-148
    • /
    • 2014
  • In recent years, computational models using parametric estimation method have been developed and used widely for efficient cost analysis. In this research, by applying experienced data from Guidance and Control Systems in Missile System field, the cost analysis for engineering model and commercial computational model(Price H, HL, M, S) are conducted and its result is analysed, so that the difference between two models and its grounds are apprehended. Comparing the calibrated value of computational model based on the data base of similar equipment and the cost from the engineering estimation, the two results are very close. It means that the credibility of data is enhanced through calibration. Also, for cost analysis of similar components in the future, the method for calibration of the computational models is also examined. When estimating development cost in this research, although many parts have been estimated through uncertain elements, the reliability could have been enhanced by applying computational model which secures objectivity. It is a very reasonable estimation method by utilizing calibration of the computational models based on existing accumulated development data.

Forest Fire Monitoring System Using Satellite (위성활용 산불감시 시스템 구축)

  • Park, Beom-Sun;Cho, In-Je;Lim, Jae-Hwan;Kim, In-Bae
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.11
    • /
    • pp.143-150
    • /
    • 2021
  • It introduces the contents of establishing a geostationary satellite-based forest fire monitoring system that can monitor areas of the Korean Peninsula 24 hours a day for forest fire monitoring, and describes how to establish a forest fire monitoring system and use it in various ways. In order to establish a satellite-utilized forest fire monitoring system, we will describe and draw conclusions on literature research, technical principles, forest fire monitoring means, and satellite forest fire monitoring system. The satellite-utilized forest fire monitoring system can consist of one geostationary satellite equipped with infrared detection optical sensors and a ground processing station that processes data received from satellites to spread surveillance information. Forest fire monitoring satellites are located in the country's geostationary orbit and should be operated 24 hours a day, 365 days a day. Forest fire monitoring technology is an infrared detection technology that can be used in national public interests such as forest fire monitoring and national security. It should be operated 24 hours a day, and to satisfy this, it is efficient to establish a geostationary satellite-based forest fire monitoring satellite system.

Feasibility Study of Fuel Property for Fuel Processing Design on Ship and Warship (연료유 공정설계를 통한 선박 및 함정의 기본품질 적용 가능성 연구)

  • Hwang, Gwang-Tak;Kim, Do-young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.143-153
    • /
    • 2018
  • Environmental regulations, which are discussed through the International Maritime Organization, focus on two aspects: the economic supply of fuel oil and, ultimately, securing next-generation energy sources. At present, there are limitations in relation to the basic quality of fuel oil and the direct relation through basic quality when applied to ships and traps in relation to environmental regulations, and the standard for the basic quality of fuel oil is generally used. There are many cases where the composition is very complicated, and the interpretation and analysis of basic quality deviate from the range of the basic standard. In other words, it is difficult to classify and apply the problem when analyzing it in connection with fuel quality and ship operations. In this paper are various factors for the basic quality of fuel oil, and a proposed possibility for the scope of the standard.

Assessment of the Electromagnetic Pulse Shield Effectiveness of the Wave-guided Below Cutoff Filled with Water and Oil for Guaranteeing the Operational Sustainment of the Command Post (지휘소 작전지속성 보장을 위한 도파관의 전자기파 차폐성능 향상방안)

  • Yoon, Sangho;Son, Kiyoung;Kim, Suk Bong;Park, Young Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.6
    • /
    • pp.579-584
    • /
    • 2013
  • The stable fueling and water supply should be prerequisites to guarantee the operational sustainment of military command post. Meanwhile, in terms of the operational sustainment, it is verified that the current wave-guided below cutoff (WBC) system cannot satisfy the requirement of control associated with water supply and fueling within the command post. In this study, as the dielectric substance can block electromagnetic pulse (EMP), it was tried to identify the shielding effectiveness of the multi WBCs filled with water and diesel for attenuating the EMP effect using experiment based on the MIL STD 188-125-1. According to the experimental results, used water in the experiment show the shielding effectiveness from around 640 MHz frequency because of minerals contained in the water. Furthermore, it was noted that EMP attenuating strength of the WBC filled with diesel was enlarged from around 1,680 MHz frequency. Resultingly, it could be concluded that it is enough to supply stable water and diesel through the multi WBC to block EMP within the military command post for guaranteeing the military operations sustainment.