• 제목/요약/키워드: Defects

Search Result 8,536, Processing Time 0.032 seconds

Investigation of the Maintenance Criteria for the Rail Surface Defects in High-Speed Railways (고속철도 레일 표면 결함 관리기준에 관한 연구)

  • Yang, Sin-Chu;Jang, Seung-Yup
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.6
    • /
    • pp.535-544
    • /
    • 2011
  • The rail surface defects can cause the high impact load on the track and lead to the progress of the rail fatigue damage and the rail break. In case of the rail break, there is a great deal of risk for derailment, and thus the maintenance criteria for the rail surface defects are of great importance. In this study, using the dynamic train-track interaction analysis program, the impact wheel loads and rail bending stresses according to the depths of the surface defects have been calculated with the input data of the rail surface irregularities measured at 43 spots with surface defects in the ballasted track of high-speed railway. Considering the irregularity of track geometry, the allowable limits of wheel load and rail bending stress have been set, and the maintenance criteria for the rail surface defects was suggested by analyzing the relationship of the maximum values of wheel load and rail bending stress versus depth and width of rail surface defect. The analysis results suggest that the allowable depth of the surface defect is determined approximately 0.2mm from the limit of the impact wheel load.

Reconstruction of Post Burn Auricular Defect (화상 후 이개부 결손의 재건)

  • Cho, Dong-Pill;Lee, Jong-Wook;Koh, Jang-Hyu;Seo, Dong-Kook;Choi, Jai-Koo;Jang, Young-Chul
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.421-426
    • /
    • 2010
  • Purpose: Patients with serious burns are prone to chondritis due to lack of soft tissue in the auricle, which can cause severe defects in the auricular morphology. In addition, skin damage occurs frequently in the vicinity of post-burn wounds, presenting difficulties in reconstruction surgery. An auricular reconstruction has functional and cosmetic significance. The aim of this study is to develop appropriate reconstruction methods for auricular defects. Methods: Thirty seven patients, who were treated for auricular defects from 2005 to 2009, were enrolled in this study. A local flap, multiple regional flaps and cartilage framework with or without a temporal fascial flap were applied in reconstruction surgery according to the location of the auricular defect. Results: The age of the subjects ranged from 11 to 56. Some subjects had defects that cover more than half of the helical rim with most exhibiting post-burn scars in the vicinity, for whom a multiple regional flap was used. A single use of a tubed flap was sufficient for subjects with defects that covered less than half of the helical rim. A regional flap was also used for reconstruction in subjects with defects covering both the helical rim and antehelix. Conclusion: Achieving satisfactory results from the skin flaps and skin grafts for post-burn auricular defects in both functional and cosmetic aspects is a difficult task. Therefore, selecting an appropriate surgical method through proper diagnosis of the auricular defect and the state of the available skin in the vicinity is essential.

Vesicoureteral Reflux and Renal Scarring in Children with Acute Pyelonephritis: the Role of Late 6-month Dimercaptosuccinic Acid Renal Scan

  • Oh, Kyeong Eun;Yim, Hyung Eun;Yoo, Kee Hwan
    • Childhood Kidney Diseases
    • /
    • v.24 no.2
    • /
    • pp.98-106
    • /
    • 2020
  • Purpose: The aim of this study is to evaluate the clinical utility of late 6-month dimercapto-succinic acid (DMSA) renal scan in predicting vesicoureteral reflux (VUR) and long-lasting renal scars in children with first acute pyelonephritis (APN). Methods: A retrospective case study of children admitted with APN from January 2010 to July 2017 was performed. The study included patients with voiding cystourethrography (VCUG) and acute and late 6-month DMSA scan. We analyzed the clinical, laboratory and imaging findings of patients with and without late cortical defects at 6 months and those with or without VUR. Results: Among 145 children with APN, 50 (34.5%) had cortical defects on the late DMSA renal scan and 60 (41.4%) showed VUR. Thirteen of 38 (34.2%) children undergoing 18-month DMSA renal scan showed a long-lasting renal scars. Compared with children without late cortical defects, patients with late 6-month cortical defects had a higher incidence of VUR and long-lasting renal scars, and relapse of UTI (all P<0.05). In a multivariable analysis, both high-grade VUR and relapse of UTI were independently correlated with the presence of late 6-month cortical defects (P<0.05). Late cortical defects and relapse of UTI were also associated with the presence of VUR (P<0.05). Only the late 6-mo cortical defects was an independent predictor of long-lasting renal scars in children with APN (P<0.05). Conclusion: An abnormal late 6-month DMSA renal scan may be useful in identifying VUR and long-lasting renal scars in children diagnosed with APN.

Detection of Defects in a Thin Steel Plate Using Ultrasonic Guided Wave (유도초음파를 이용한 박판에서의 결함의 검출에 관한 연구)

  • Jeong, Hee-Don;Shin, Hyeon-Jae;Rose, Joseph L.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.6
    • /
    • pp.445-454
    • /
    • 1998
  • In order to establish a technical concept for the detection of defects in weldments in thin steel plate, an experimental and theoretical investigation was carried out for artificial defects in a steel plate having a thickness of 2.4mm by using the guided wave technique. In particular the goal was to find the most effective testing parameters paying attention to the relationship between the excitation frequency by a tone burst system and various incident angles. It was found that the test conditions that worked best was for a frequency of 840kHz and an incident angle of 30 or 85 degrees, most of the defects were detected with these conditions. Also, it was clear that a guided wave mode generated under an incident angle of 30 degrees was a symmetric mode, So, and that of 85 degrees corresponded to an antisymmetric mode, Ao. By using the two modes, most of all of the defects could be detected. Furthermore, it was shown that the antisymmetric mode was more sensitive to defects near the surface than the symmetric mode. Theoretical predictions confirmed this sensitivity improvement with Ao for surface defects because of wave structure variation and energy concentration near the surface.

  • PDF

A Study on the Newly Recognized Defect Factors in Defect Lawsuits of Apartment Housing (공동주택 하자소송단계에서의 하자인정항목에 관한 연구)

  • Ko, Young-Tae;Shin, Yoon-Seok;Lee, Myungdo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.6
    • /
    • pp.567-576
    • /
    • 2020
  • This study proposes additional items to be recognized as defects in a defect lawsuit through a case analysis of lawsuit cases in apartment housing. Identifying these defects prevents an unexpected increase in litigation costs, delays in the date of litigation, and emotion repercussions or additional lawsuits. In this study, the defects that were not discovered by the existing occupants and construction companies, but were newly discovered in litigation, were defined as defects in lawsuits. Fifteen cases of lawsuits were analyzed and a total of 77 defects were derived. Each item was then reviewed for location, work type, number of occurrences, and cost. The results were yielded 23 defect items, which were validated by appraisers who directly appraised the cases. In addition, the derived defect factors were analyzed. Finally, the 23 defect items were categorized into 10 main factors which include attributes such as causes of occurrence and characteristics. This can provide an overall area of defects to be considered in addition to existing defect items in the life cycle of the housing. The results of this study can contribute to reducing the actual occurrence of defects and minimizing the disputes in the case of defect lawsuits.

Effects of Proton Irradiation on the Microstructure and Surface Oxidation Characteristics of Type 316 Stainless Steel (양성자 조사가 316 스테인리스강의 미세조직과 표면산화 특성에 미치는 영향)

  • Lim, Yun-Soo;Kim, Dong-Jin;Hwang, Seong Sik;Choi, Min Jae;Cho, Sung Whan
    • Corrosion Science and Technology
    • /
    • v.20 no.3
    • /
    • pp.158-168
    • /
    • 2021
  • Austenitic 316 stainless steel was irradiated with protons accelerated by an energy of 2 MeV at 360 ℃, the various defects induced by this proton irradiation were characterized with microscopic equipment. In our observations irradiation defects such as dislocations and micro-voids were clearly revealed. The typical irradiation defects observed differed according to depth, indicating the evolution of irradiation defects follows the characteristics of radiation damage profiles that depend on depth. Surface oxidation tests were conducted under the simulated primary water conditions of a pressurized water reactor (PWR) to understand the role irradiation defects play in surface oxidation behavior and also to investigate the resultant irradiation assisted stress corrosion cracking (IASCC) susceptibility that occurs after exposure to PWR primary water. We found that Cr and Fe became depleted while Ni was enriched at the grain boundary beneath the surface oxidation layer both in the non-irradiated and proton-irradiated specimens. However, the degree of Cr/Fe depletion and Ni enrichment was much higher in the proton-irradiated sample than in the non-irradiated one owing to radiation-induced segregation and the irradiation defects. The microstructural and microchemical changes induced by proton irradiation all appear to significantly increase the susceptibility of austenitic 316 stainless steel to IASCC.

Electronic properties of graphene nanoribbons with Stone-Wales defects using the tight-binding method

  • M.W. Chuan;S.Z. Lok;A. Hamzah;N.E. Alias;S. Mohamed Sultan;C.S. Lim;M.L.P Tan
    • Advances in nano research
    • /
    • v.14 no.1
    • /
    • pp.1-15
    • /
    • 2023
  • Driven by the scaling down of transistor node technology, graphene became of interest to many researchers following the success of its fabrication as graphene nanoribbons (GNRs). However, during the fabrication of GNRs, it is not uncommon to have defects within the GNR structures. Scaling down node technology also changes the modelling approach from the classical Boltzmann transport equation to the quantum transport theory because the quantum confinement effects become significant at sub-10 nanometer dimensions. The aim of this study is to examine the effect of Stone-Wales defects on the electronic properties of GNRs using a tight-binding model, based on Non-Equilibrium Green's Function (NEGF) via numeric computation methods using MATLAB. Armchair and zigzag edge defects are also implemented in the GNR structures to mimic the practical fabrication process. Electronic properties of pristine and defected GNRs of various lengths and widths were computed, including their band structure and density of states (DOS). The results show that Stone-Wales defects cause fluctuation in the band structure and increase the bandgap values for both armchair GNRs (AGNRs) and zigzag GNRs (ZGNRs) at every simulated width. In addition, Stone-Wales defects reduce the numerical computation DOS for both AGNRs and ZGNRs. However, when the lengths of the structures increase with fixed widths, the effect of the Stone-Wales defects become less significant.

The Analysis of Amplitude and Phase Image for Acoustic Microscope Using Quadrature Technique (쿼드러춰 방식에 의한 초음파현미경의 진폭과 위상영상 분석)

  • Kim, Hyun;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.55-61
    • /
    • 1999
  • In this study, we have constructed the acoustic microscope using quadrature technique and analyzed the relative variation of image intensity and the quality of image by reconstructing the amplitude and phase image for surface defects with tiny hight variation. In this experiment, we have constructed the scanning acoustic microscope using the focused transducer with 3㎒ center frequency and the quadrature detector. And we have fabricated aluminum samples with round defects whose depth is different and reconstructed the amplitude and phase images for the samples. One sample has round defects with 2㎜ diameter and 100㎛ depth and the other has round defects with 4㎜ diameter and 5㎜ depth. In the result of line scanning for the sample with 100㎛ round defects, it has been shown that the variation rate of amplitude image intensity is 7% and the variation rate of phase image intensity is 89%. The phase image has better contrast than amplitude image for the sample. In contrast to this, the amplitude image has better contrast than phase image for the sample with 5㎜ depth's defects. Accordingly there is big difference between amplitude image and phase image for depth variation of defects whose boundary is 1 wavelength. Consequently the acoustic microscope using quadrature detector can be evaluated efficiently more than using envelope detector, for detecting defects which have height variation less than 1 wavelength. And also the phase image and the amplitude image can be used for detecting defects of tiny height variation with complimentary relation.

  • PDF

Reconstruction of the Large Soft Tissue Defects around Knee Joint with Para-Scapular and Latissimus Dorsi Myocutaneous Free Flap based on Subscapular Vessels (슬관절 주변의 광범위한 연부조직 결손 시에 시행한 광배근-부견갑 피판을 동시에 사용한 유리 피판술의 효과)

  • Chung, Duke-Whan;Lee, Jae-Hoon
    • Archives of Reconstructive Microsurgery
    • /
    • v.11 no.1
    • /
    • pp.11-18
    • /
    • 2002
  • Large soft tissue defects around the knee joint are known to significantly diminish joint function. Severe soft tissue defects on the anterior aspect of the knee joint especially bring on significant joint motion limitation. Although simple split skin grafts can cover the skin defect, the progressing scar contracture of the grafted skin causes joint stiffness. One of the best solutions of large soft tissue defects around the knee joint is covering the defect with a good quality skin flap. Separated flaps with one vascular pedicle are good candidates for covering anterior and posterior aspects of the joint for example. Authors performed 12 cases of combined scapular and latissimus dorsi free flaps from 1984 to 2000. Among them, we experienced 5 cases of knee joint defect covering using the double free flap for coverage of the soft tissue defect with preservation of the knee joint function and satisfactory results. The system of flaps based on the subscapular artery and vein provides a variety of composite free flaps. The possible flaps that can be harvested based on this single vascular pedicle include the scapular and parascapular skin flap, the serratus anterior and latissimus dorsi muscular flap, the lateral scapular bone flap, the latissimus dorsi-rib flap, and the serratus anterior-rib flap. This combined flap is available for multiple tissue defects or complex defects because it can be incorporated with skin, muscle and bone flaps. A main advantage is the independent vascular pedicles of each component, which allow freedom in orientation of each components. Consequently it can be freely applied to any form of three dimensional defects on the upper and lower extremities. The combination of scapular cutaneous flap and latissimus dorsi musculocutaneous flap can be resurfaced for massive cutaneous defects on the extremities. We report the use of the combined scapular and latissimus dorsi free flap in five patients to reconstruct massive defects on the extremities with resultant improved joint function. There was no flap failure and minimal complications and disadvantages. The anatomy of this flap is reviewed and the indication and advantages are discussed. All of the five flaps survived and there was no scar contracture affecting the joint motion.

  • PDF