• Title/Summary/Keyword: Defect types

Search Result 488, Processing Time 0.027 seconds

Usefullness of Chimeric Flaps Based on the Subscapular Vascular System (견갑하 혈관경을 기저로 하는 키메라 피판의 유용성)

  • Kim, Hyon Surk;Lim, Hyung Woo;Park, Seung Ha;Lee, Byung Il
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.597-604
    • /
    • 2009
  • Purpose: Compound tissue defects remain a challenge to reconstructive surgeons. The objective of this study was to introduce examples of successful reconstruction of compound defects of the head and neck and upper and lower limbs, using chimeric flaps based on the subscapular vascular system. Methods: We report 19 reconstruction cases using chimeric flaps based on the subscapular vascular system. The scapular flap, scapular fascia, scapular bone, parascapular flap, latissimus dorsi, latissimus dorsi perforator flap, latissimus dorsi myocutaneous perforator flap, serratus anterior, serratus anterior fascia, and rib bone were used as components for chimeric flaps. 12 cases had defects of the upper limb, three in the lower limb, three in the head and neck area, and one case had a defect of the thoracoabdominal wall. Results: Defect sizes ranged from $6{\times}8cm$ to $20{\times}22cm$. The component used most often for skin coverage was the latissimus dorsi perforator flap; for soft tissue bulk, the latissimus dorsi; for fascia coverage, the serratus anterior fascia flap; and for bone reconstruction, the scapular bone flap respectively. All cases were successfully reconstructed without additional operative procedures or flap necrosis. Conclusion: Because it is fairly easy to employ vascular pedicles of sufficient length and diameter, enabling the use of diverse types of tissue with various shapes and sizes, the use of chimeric flaps based on the subscapular vascular system allows one - stage reconstruction tailored to the characteristics of the defect area.

Morphological and Chemical Analysis of Various Disposable Acupuncture Needles Used in South Korea

  • Dong Yong, Park;JiYoon, Ahn;Hyeon Jeong, Park;Doo Suk, Lee;Dae-Hyun, Jo;Jonghoon, Kim;Choulmin, Kim;Heebum, Chung;Ji Hye, Hwang
    • Journal of Pharmacopuncture
    • /
    • v.25 no.4
    • /
    • pp.382-389
    • /
    • 2022
  • Objectives: The Korean Industrial Standard (KS) for sterile acupuncture needles was established in 2009 based on research on the quality control of acupuncture needles. We aimed to determine the quality of acupuncture needles available in South Korea in 2021 by examining their surface condition and chemical composition using field-emission scanning electron microscopy (FE-SEM) and energy-dispersive X-ray spectroscopy (EDS). Methods: In South Korea, there are 23 brands of acupuncture needles, and we examined 10-15 needles from each brand, resulting in a total of 285 needles. The microstructures of the needles were assessed by SEM. Using SEM images, we evaluated the acupuncture needle tips for the following defects/aspects: scratches, lumps, detached coating, bent tip, and tip sharpness. EDS was used to determine the chemical composition of the selected acupuncture needles. Results: Overall, 88.4% of 285 needles were found to have at least one type of abnormality. The most frequently observed abnormalities were scratches and dents on the surface (68.1%), followed by detached coating (63.2%), and lumps (61.8%); blunt tips were observed in about 24% of them. Of 252 needles with at least one defect, 86.9% had two or more types of defects. The ratio of the number of needles with any defect to that of needles without any defect varied among brands, ranging from 50% to 100%. Regarding foreign materials, higher proportions of Si and O were observed on the needles, indicating incomplete or detached silicone coating. Conclusion: The quality of acupuncture needles varied among brands, suggesting that further improvements can be made through various inspection methods.

A study on the improvement of concrete defect detection performance through the convergence of transfer learning and k-means clustering (전이학습과 k-means clustering의 융합을 통한 콘크리트 결함 탐지 성능 향상에 대한 연구)

  • Younggeun Yoon;Taekeun Oh
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.2
    • /
    • pp.561-568
    • /
    • 2023
  • Various defects occur in concrete structures due to internal and external environments. If there is a defect, it is important to efficiently identify and maintain it because there is a problem with the structural safety of concrete. However, recent deep learning research has focused on cracks in concrete, and studies on exfoliation and contamination are lacking. In this study, focusing on exfoliation and contamination, which are difficult to label, four models were developed and their performance evaluated through unlabelling method, filtering method, the convergence of transfer learning based k-means clustering. As a result of the analysis, the convergence model classified the defects in the most detail and could increase the efficiency compared to direct labeling. It is hoped that the results of this study will contribute to the development of deep learning models for various types of defects that are difficult to label in the future.

Curvilinear free-edge form effect on stability of perforated laminated composite plates

  • Zerin, Zihni;Basoglu, Muhammed Fatih;Turan, Ferruh
    • Structural Engineering and Mechanics
    • /
    • v.61 no.2
    • /
    • pp.255-266
    • /
    • 2017
  • In this study, self-supporting roofing elements especially convenient for large-span structures such as stadium, airport terminal, mall, coliseum, etc. were examined with respect to critical buckling load. These elements were assumed as laminated composite plates and, variation of free-edge forms, cutout types and lamination configurations were used as design parameters. Based on the architectural feature and structural requirements, the effects of curvilinear free-edge form on critical buckling load were focused on in this research. Within this scope, 14 types of lamination configuration were specified according to various orientation angle, number and thickness of plies with a constant value of total plate thickness. Besides that, 6 different types of cutout and 3 different free-edge forms were determined. By combining all these parameters 294 different critical buckling load analyses were performed by using ANSYS Mechanical software based on finite element method. Effects of those parameters on critical buckling load were evaluated referring to the obtained results. According to the results presented here, it may be concluded that lamination conditions have more significant influence on the critical buckling load values than the other parameters. On the other hand, it is perceived that curvilinear free-edge forms explicitly undergo changings depending on lamination conditions. For future work, existence of delamination might be considered and progression of the defect could be investigated by using non-linear analysis.

Why Do We Pay for Advertising Models?: Suggestions for Maximizing Advertising Effectiveness

  • Han, Sang-Ho;Cho, Hee-Young;Yang, Hoe-Chang
    • Asian Journal of Business Environment
    • /
    • v.4 no.1
    • /
    • pp.15-23
    • /
    • 2014
  • Purpose - In this study, we inspected the effects of public-service advertising (PSA) and commercial advertisements on consumers' social and emotional values. Specifically, we include source credibility on advertising models as a mediating variable to compare the path difference between the social and emotional value of consumers, and to test the appropriateness of advertising expenses. Research design, data, and methodology - A total of 219 copies of effective questionnaires were used and methodologies such as Cronbach's alpha, paired samples t-test, and structural equation modeling (SEM) were conducted. Results - The results showed that the consumer model was effective at PSA, while celebrities and CEOs were effective at commercial advertising. Further, only credibility (among source credibility) made a significant difference in the test of PSA models of both PSA and commercial advertising that consumers preferred. Conclusions - The advertising model types varied depending on advertising types (for example, PSA and commercial advertising). Therefore, celebrities and CEOs appearing in commercial advertising should have no ethical or moral defect by self-control, and marketers should elect the model considering such a fact.

Evaluation of Membrane Damage Sensitivity by Defect Types for Improving Reliability of Membrane Integrity Monitoring (막 완결성 모니터링 신뢰성 향상을 위한 손상 유형별 막 손상 감도 평가)

  • Lee, Yong-Soo;Kang, Ha-Young;Kim, Hyung-Soo;Kim, Jong-Oh
    • Membrane Journal
    • /
    • v.27 no.3
    • /
    • pp.248-254
    • /
    • 2017
  • In order to secure the reliability of pathogenic microorganisms such as Cryptosporidium and Giaridia, which are chlorophilic protozoans, membrane filtration systems have been widely used in water purification process. hese integrity tests are classified into direct and indirect methods. Based on the bubble point theory, the pressure-based test in the direct method is presented in the USEPA Guidance Manual with sensitivity to detect a minimum size of pathogenic microorganisms of $3{\mu}m$ or more. Indirect methods are widely used in that they are capable of continuous operation in on-line state, but there is a very low sensitivity of damage detection compared to the direct method, and there is a limit that can not specify the damage area, so it is necessary to improve this sensitivity. In this study, we compared the LRVDIT and UCL values according to the type of membrane defect, number of fiber breaks, and initial set pressure value through the Integrity Test by Pressure Decay Test (PDT).

Serial Changes of Cardiac Troponin I After Pediatric Open Heart Surgery (소아 개심술 환아에서의 Cardiac Troponin I의 변화)

  • Kim, Yeo Hyang;Hyun, Myung Chul;Lee, Sang Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.2
    • /
    • pp.208-213
    • /
    • 2002
  • Purpose : The major cause of cardiac dysfunction, after open heart surgery for congenital heart disease, is perioperative myocardial injury. Cardiac troponin I is found only within the myocardial cell, so it can be used as a biochemical marker of the myocardial injury. We performed this study to evaluate the worth of cardiac troponin I as a biochemical marker reflecting the extent of perioperative myocardial injury and recovery. Methods : Thirty-four patients who had undergone elective open heart surgery of congenital heart disease(CHD) from April to July 2001 were enrolled in this study. We measured types of CHD, serial cardiac troponin I(baseline 1 day before operation, postoperative day 1, 2, 3, 7), duration of cardiopulmonary bypass(CPB), aortic cross clamping(ACC), intubation and postoperative hospital stay. Results : Compared with the baseline before operation, there was a significant, increase of cardiac troponin I on the postoperative day 1 and a significant gradual decrease on the day 2, 3, 7. The levels of cardiac troponin I were the highest in the transposition of great artery(TGA) repair on the postoperative day 1 and high in the tetralogy of Fallot(TOF), atioventricular septal defect (AVSD), ventricular septal defect(VSD) and atrial septal defect(ASD) repair with decreasing sequence. The longer duration of CPB, ACC and intubation, the higher of cardiac troponin I, but there were no significant correlations between cardiac troponin I levels and duration of hospital stay. Conclusion : Because there was significant increases or decreases of cardiac troponin I according to the perioperative time and types of the congenital heart disease, it is a worthy biochemical marker which reflects the extent of perioperative myocardial injury and recovery after open heart surgery.

Comparative analysis of the in vivo kinetic properties of various bone substitutes filled into a peri-implant canine defect model

  • Jingyang Kang;Masaki Shibasaki;Masahiko Terauchi;Narumi Oshibe;Katsuya Hyodo;Eriko Marukawa
    • Journal of Periodontal and Implant Science
    • /
    • v.54 no.2
    • /
    • pp.96-107
    • /
    • 2024
  • Purpose: Deproteinized bovine bone or synthetic hydroxyapatite are 2 prevalent bone grafting materials used in the clinical treatment of peri-implant bone defects. However, the differences in bone formation among these materials remain unclear. This study evaluated osteogenesis kinetics in peri-implant defects using 2 types of deproteinized bovine bone (Bio-Oss® and Bio-Oss/Collagen®) and 2 types of synthetic hydroxyapatite (Apaceram-AX® and Refit®). We considered factors including newly generated bone volume; bone, osteoid, and material occupancy; and bone-to-implant contact. Methods: A beagle model with a mandibular defect was created by extracting the bilateral mandibular third and fourth premolars. Simultaneously, an implant was inserted into the defect, and the space between the implant and the surrounding bone walls was filled with Bio-Oss, Bio-Oss/Collagen, Apaceram-AX, Refit, or autologous bone. Micro-computed tomography and histological analyses were conducted at 3 and 6 months postoperatively (Refit and autologous bone were not included at the 6-month time point due to their rapid absorption). Results: All materials demonstrated excellent biocompatibility and osteoconductivity. At 3 months, Bio-Oss and Apaceram-AX exhibited significantly greater volumes of formation than the other materials, with Bio-Oss having a marginally higher amount. However, this outcome was reversed at 6 months, with no significant difference between the 2 materials at either time point. Apaceram-AX displayed notably slower bioresorption and the largest quantity of residual material at both time points. In contrast, Refit had significantly greater bioresorption, with complete resorption and rapid maturation involving cortical bone formation at the crest at 3 months, Refit demonstrated the highest mineralized tissue and osteoid occupancy after 3 months, albeit without statistical significance. Conclusions: Overall, the materials demonstrated varying post-implantation behaviors in vivo. Thus, in a clinical setting, both the properties of these materials and the specific conditions of the defects needing reinforcement should be considered to identify the most suitable material.

The Effectiveness of Accounting Information in Military Construction Contracts under the Qualification Assessment System (적격심사낙찰제 계약에서 회계정보의 유용성에 관한 연구)

  • Hur, Hyung
    • Journal of the military operations research society of Korea
    • /
    • v.37 no.1
    • /
    • pp.49-70
    • /
    • 2011
  • This paper re-evaluated the research on the accounting information's effectiveness in military construction contracts, questioning the former research results on the central army's construction contract that was under the Qualification Assessment System, especially concerning the relations between the accounting information and the bidding ratios as well as the relations between the bidding rates and the defect rates, which targeted between 1 to 10 billions civil engineering, construction, electricity, telecommunication, and environment work types. Unlike the previous results, the relationship between the accounting information and the bidding rates was shown to be considerably limited that the bidding ratio could not be identified through the accounting information, while it could discern the relations with the defect rates. Furthermore, the proven results did not support the hypothesis that the differences in bidding rates could affect the defect ratio. However, through the prediction model of bidding and defect ratios, we could identity the accounting variables that influenced the ratios. Additionally through the results regarding the non-financial indexes in the Pre-Qualification items, the weight on these indexes could be adjusted. In conclusion, the research results has given us new understanding of the problems in the Qualification Assessment System which accounts for the majority of the current military construction contracts and provide validity on the government's expanded implementation of the Lowest Price Award System.

Surgical indication analysis according to bony defect size in pediatric orbital wall fractures

  • Kim, Seung Hyun;Choi, Jun Ho;Hwang, Jae Ha;Kim, Kwang Seog;Lee, Sam Yong
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.5
    • /
    • pp.276-282
    • /
    • 2020
  • Background: Orbital fractures are the most common pediatric facial fractures. Treatment is conservative due to the anatomical differences that make children more resilient to severe displacement or orbital volume change than adults. Although rarely, extensive fractures may result in enophthalmos, causing cosmetic problems. We aimed to establish criteria for extensive fractures that may result in enophthalmos. Methods: We retrospectively reviewed the charts of patients aged 0-15 years diagnosed with orbital fractures in our hospital from January 2010 to February 2019. Computed tomography images were used to classify the fractures into linear, trapdoor, and open-door types, and to estimate the defect size. Data on enophthalmos severity (Hertel exophthalmometry results) and fracture pattern and size at the time of injury were obtained from patients who did not undergo surgery during the follow-up and were used to identify the surgical indications for pediatric orbital fractures. Results: A total of 305 pediatric patients with pure orbital fractures were included-257 males (84.3%), 48 females (15.7%); mean age, 12.01±2.99 years. The defect size (p=0.002) and fracture type (p=0.017) were identified as the variables affecting the enophthalmometric difference between the eyes of non-operated patients. In the linear regression analysis, the variable affecting the fracture size was open-door type fracture (p<0.001). Pearson's correlation analysis demonstrated a positive correlation between the enophthalmometric difference and the bony defect size (p=0.003). Using receiver operating characteristic curve analysis, a cutoff value of 1.81 ㎠ was obtained (sensitivity, 0.543; specificity, 0.724; p=0.002). Conclusion: The incidence of enophthalmos in pediatric pure orbital fractures was found to increase with fracture size, with an even higher incidence when open-door type fracture was a cofactor. In clinical settings, pediatric orbital fractures larger than 1.81 ㎠ may be considered as extensive fractures that can result in enophthalmos and consequent cosmetic problems.