• Title/Summary/Keyword: Defect ratio

Search Result 466, Processing Time 0.027 seconds

Bone formation of newly developed biphasic calcium phosphate in rabbit calvarial defect model : A pilot study (토끼 두개골에서 새로 개발된 biphasic calcium phosphate의 골형성 효과 : A pilot study)

  • Um, Yoo-Jung;Hong, Ji-Yeon;Kim, Sung-Tae;Lee, Yong-Ho;Park, Sang-Hyun;Park, Sun-Hyo;Cho, Kyoo-Sung;Chai, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.38 no.2
    • /
    • pp.163-170
    • /
    • 2008
  • Purpose: Biphasic calcium phosphates have been of great interest recently. Mixing adequate ratios of hydroxyapatite(HA) and beta-tricalcium phosphate($\beta$-TCP) allowed to control the resorption rate without distorting its osteoconductive property. This study evaluated the bone formation effect of newly developed biphasic calcium phosphate(BCP) in calvarial defect of rabbits. Materials and Methods: 6 male New Zealand rabbits were used. Four defects with 8mm in diameter were created on each animal. BCP with HA/$\beta$-TCP ratio of 7:3 and particle size of $0.5{\sim}1.0\;mm$ was used as the test group and bovine bone with $0.25{\sim}1.0\;mm$ particle size, as the control group. Both test and control group materials were randomly implanted in the calvarial defects and were covered witha polymer membrane. The animals were sacrificed after 12, 24, and 48 weeks of implantation under general euthanasia. Resin blocks were obtained and were stained by masson's trichrome for histological observation. Results: Overall results were uneventful without any defect exposure or inflammation. The amount of new bone formation and bone maturity increased with increase in healing period at both groups. New bone in test group was mostly formed along the material particle surrounded by osteoblasts, and observation of osteoblastic stream was also present. Bone maturity increased as it was closer to thedefect margins. Under the same healing period, the test group showed more bone formation than the control group with more stable bovine bone particles remaining even after 48 weeks, whereas considerable resorption took place in BCP. Almost total defect closure was observed in test group with new bone formation in the central part of the defect. However, limited new bone formation was observed in the control group. Conclusion: Within the limits of the study, the present study reveals the newly developed BCP to be a good osteoconductive material. However, further studies are needed to be conducted in a different study model with a larger sample size.

Guidedwave-induced rockbolt integrity using Fourier and wavelet transforms (유도파에 대한 푸리에 및 웨이브렛 변환을 이용한 록볼트의 건전도 평가)

  • Lee, In-Mo;Kim, Hyun-Jin;Han, Shin-In;Lee, Jong-Sub
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.9 no.4
    • /
    • pp.403-413
    • /
    • 2007
  • As rock bolts become one of the main support systems in tunnels and underground structures, the integrity of the rock bolts affects the safety of these types of structures. The purpose of this study is the evaluation of rock bolt integrity using Fourier and wavelet transforms of the guided ultrasonic waves. After five rock bolt specimens with various defect ratios are embedded into a large scale concrete block, guided waves are generated by a PZT (lead zirconate titanate) element and measured by an acoustic emission (AE) sensor. The captured signals are analyzed in the frequency domain using the Fourier transform, and in the time-frequency domain using the wavelet transform based on a Gabor wavelet. The spectrum obtained from the Fourier transform shows that a portion of high frequency contents increases with increase in the defect ratio. Peak values in the time-frequency domain represent the interval of travel time of each echo. The energy velocities of the guided waves increase with the defect ratio. This study shows that the spectrum ratio and the energy velocity may be indicators fur the evaluation of rock bolt integrity.

  • PDF

PDP 공정결함 평가ㆍ분석에 관한 연구

  • 김현종;송준엽;박화영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.204-204
    • /
    • 2004
  • 현재 정보통신의 강국으로 손꼽히고 있는 국내에서도 FPD(Flat Panel Display) 장치를 첨단산업 핵심 기술로 보고 기업 간에 치열한 기술경쟁을 벌이고 있는 실정이다. 현재 양산단계까지 접어든 TFT-LCD(Tin Film Transistor Liquid Crystal Display)와 PDP(Plasma Display Panel)는 경량화, 박형화 등의 장점으로 전자업계에서 최고의 캐시카우(Cash Cow)로 부각되고 있으며, 특히 소비자들의 대화면 선호도의 증가 추세에 힘입어 LCD보다는 콘트라스트 비(Contrast Ratio)와 시야각(View Angle) 측면에 있어 FPD 장치의 대면적화 관점에서 유리한 PDP가 다소 우위를 보이고 있는 추세이다.(중략)

  • PDF

A study on the computed aided gating design in gray cast iron (컴퓨터를 이용한 회주철의 탕구방안 설계에 관한 연구)

  • Choi, Jeong-Kil;Kim, Dong-Ok
    • Journal of Korea Foundry Society
    • /
    • v.6 no.1
    • /
    • pp.27-35
    • /
    • 1986
  • The gating design of gray cast iron was programmed in a Personal computer. By this program, casting test was done. The results obtained are as follows. 1. Gating design that can calculate the velocity of metal flow and size in each gate section by knowing the loss coefficient caused by friction loss and bend loss was programmed. 2. In the test casting, the gating ratio was changed into 1.1:1.3:1, 1:2:2, 1:4:4. And sound casting, free of sand washing defect, was obtained at the velocity of 35.5cm/sec in ingate.

  • PDF

Propagation Characteristics of Fatigue Microcracks on Smooth Specimen of $2_{1/4}$ Cr-1 Mo Steel ($2_{1/4}$ Cr-1 Mo강의 평활재상의 미소한 표면피로균열의 성장특성)

  • Suh, Chang-Min;Woo, Byung-Chul;Jang, Hui-Rak
    • Journal of Ocean Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.100-111
    • /
    • 1990
  • In this paper, fatigue tests were carried out at stress test levels of 461 MPa, 441 MPa, and 431 MPa by using smooth specimen of$2_{1/4}$ Cr-1 Mo steel with the stress ratio(R) of 0.05. The initiation, growth and coalescense process of the major cracks and sub-cracks among the fatigue cracks on the smooth specimen are investigated and measured under each stress level at a constant cycle ratio by the replica technique with optical microscope. Some of the important results are as follows: In spite of the difference of stress levels, the major crack data gather into a small band in the curve of surface crack length and crack depth against cycle ratio N/Nf. The sub-crack data, however, deviate from the band of the major crack. The growth rates, da/dN, of major and sub-crack plotted against the stress intensity factor range, ${\Delta}K$, have the tendency to be compressed on a relatively small band. But it is more effective to predict fatigue life through major cracks. The propagation behavior of surface microcracks on the smooth specimens coincides with that of the specimen having an artificial small surface defect or through crack.

  • PDF

Surface Morphology Control of Monodisperse Crosslinked-Polymer Particle (단분산 가교고분자 미립자의 표면 모폴로지 제어 연구)

  • Kim, Dong-Ok;Jin, Jeong-Hee;Oh, Seok-Heon
    • Polymer(Korea)
    • /
    • v.30 no.1
    • /
    • pp.50-55
    • /
    • 2006
  • When the monodisperse polystyrene(PS)/HDDA polymer particles were synthesized via one-step polymerization using polystyrene seed particles by dispersion polymerization, the effects of 1) the molecular weight of seed polymer particles, 2) the ratio of the absorbed HDDA to the seed polymer particles (swelling ratio) and 3) seeded polymerization rate on the surface morphology of PS/HDDA polymer particles were investigated. It was observed that the creation of the crater shaped defect on the surface of PS/HDDA polymer particles was irrespective of the molecular weight of seed polymer ant swelling ratio. But its surface morphology could be controlled by the change of the seeded polymerization rate.

Evaluation of echocardiographic markers in dogs with patent ductus arteriosus after ductal closure

  • Park, Jong-In;Suh, Sang-IL;Hyun, Changbaig
    • Korean Journal of Veterinary Research
    • /
    • v.56 no.4
    • /
    • pp.209-213
    • /
    • 2016
  • This study evaluated several known echocardiographic markers related to the assessment of severity in dogs with patent ductus arteriosus (PDA) after the closure of ductus arteriosus (DA). Forty-two dogs with patent ductus arteriosus were enrolled in this study. Evaluated echocardiographic markers were left atrial to aortic root ratio, left ventricular end-diastolic dimension to aortic root ratio, indexed left ventricular end-diastolic and end-systolic dimensions, end-diastolic and end systolic volume index, pulmonic flow to systemic flow (Qp/Qs) ratio, velocities of pulmonary regurgitant and systolic jets, pulmonary flow profiles and the presence of mitral regurgitation. Those markers were evaluated before, 1 day, and 30 days after the closure of DA. Statistically significant changes in some echocardiographic markers (i.e., Qp/Qs) were observed. Although several studies in human and dogs have evaluated the clinical outcome of PDA occlusion using several echocardiographic markers, this study has firstly evaluated all echocardiographic markers known to be useful for assessing the clinical outcome of PDA occlusion in human, and has demonstrated that those markers including the Qp/Qs and pulmonary flow profiles were useful in evaluating of clinical outcome of PDA in dogs and the reduction of LA and LV preload after ductal closure could dramatically reduce after successful ductal occlusion of PDA in dogs.

An Acoustic Analysis of Noise Environments during Mobile Device Usage

  • Park, Hyung Woo
    • International journal of advanced smart convergence
    • /
    • v.6 no.2
    • /
    • pp.16-23
    • /
    • 2017
  • In contemporary modern society, people are constantly exposed to many kinds of noise, such as that from machinery, aircraft, construction sites, or road traffic. Noise is considered one of the most indispensable and influential parts of human life. This study investigates the acoustic characteristics of noise transfer from external sources to the human ear. For this study, we measured and analyzed various types of noise environments, installed monitoring speakers in a semi-anechoic room, and conducted intentional noise-filled experiments. In this environment, the size of the sounds generated by use of a portable device was also measured and the SNR (signal to noise ratio) calculated to study the influence of the noise. As sound is transmitted to the ear and the human body, it affects not only auditory damage but also other parts of the body. In this paper, we propose a proper SNR for noise emitted by portable IT equipment to prevent hearing loss when IT equipment is used.

X-ray Scattering Studies for Phase Separated Composite Organic Films

  • Choi, H.;Eom, K.E.;Wang, Q.;Kumar, S.;Kim, J.H.;Shin, S.T.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1229-1232
    • /
    • 2004
  • The ratio of optimized concentration on optical characteristics for phase-separated composite organic films (PSCOF) liquid crystal display is 30% of pre-polymer (NOA65) and 70% of ferroelectric liquid crystal (Felix). The layer structure in ferroelectric liquid crystal cell made by 30% NOA65 and 70% Felix materials is tilt-bookshelf layer structure. The angle of tilt-bookshelf structure are 17$^{\circ}$, 12$^{\circ}$ which are almost same of tilt angle of ferroelectric liquid crystal in Sm $C^{\ast}$ phase. We know that this result is from compensating the layer buckling. In this paper, we will discuss the effect of layer structure in PSCOF cell on ratio of concentration between pre-polymer and liquid crystal by x-ray measurements. We believe that technology of PSCOF is a good solution to solve the problems of align-defect and mechanical shock for future TV application and plastic LCD.

  • PDF

Decreased Levels of Plasma Testosterone/LH Ratio in Male Mice Exposed to Sodium Arsenite

  • Chang, Soo-Im;Kim, Soo-Hee;Park, Jung-Duck;Ryu, Doug-Young
    • Biomolecules & Therapeutics
    • /
    • v.18 no.3
    • /
    • pp.257-261
    • /
    • 2010
  • While it's been shown that arsenic impairs male reproductive function, it remains unclear whether the mechanism involves an effect on testosterone (T) production. We examined plasma T and luteinizing hormone (LH) levels in mice given water containing either 20 or 40 mg/L sodium arsenite (SA). The plasma T levels were lower in SA-treated mice than in controls and correlated well with testicular T levels within individuals. However, SA treatment did not significantly affect plasma LH levels. The ratio of plasma T to LH was reduced by the treatment with 40 mg/L SA. These results suggest arsenic-induced defect in testicular testosterone production in mice.