• 제목/요약/키워드: Defect State

검색결과 348건 처리시간 0.02초

Friction Stir Welding Tool Geometries Affecting Tensile Strength of AA6063-T1 Aluminum Alloy Butt Joint

  • Kimapong, Kittipong;Kaewwichit, Jesada;Roybang, Waraporn;Poonnayom, Pramote;Chantasri, Sakchai
    • International journal of advanced smart convergence
    • /
    • 제4권1호
    • /
    • pp.145-153
    • /
    • 2015
  • Friction Stir Welding (FSW) is a solid state welding that could successfully weld the difficult-to-weldmaterials such as an aluminum alloy. In this welding process, the stirrer of the welding tool is one of the important factors for producing the perfect sound joint that indicates the higher joint strength. So, this report aims to apply the friction stir welding using various stirrer geometries to weld the AA6063-T1 aluminum alloy butt joint, investigates the mechanical properties of the joint and then compares the mechanical properties with the microstructure of the joint. An experiment was started by applying the friction stir welding process to weld a 6.3 mm thickness of AA6063-T1 aluminum alloy butt joint. A study of the stirrer geometries effect such as a cylindrical geometry, a cone geometry, a left screw geometry and a right screw geometry at a rotational speed of 2000 rpm and a welding speed of 50-200 mm/min was performed. The mechanical properties such as a tensile strength and a hardness of the joint were also investigated and compared with the microstructure of the joint. The results are as follows. A variation of FSW Stirrer shape directly affected the quality AA6063-T1 aluminum alloy butt joint. A cylindrical stirrer shape and a cone stirrer shape produced the void defect at the bottom part of the weld metal and initiated the failure of the joint when the joint was subjected to the load during the tensile test. Left and right screw stirrer shapes gave the sound joint with no void defect in the weld metal and affected to increase the joint strength that was higher than that of the aluminum base metal.

수지 재건시 불충분한 혈행상태의 수혜부에 시행한 동맥화 정맥 유리 피판술 (Arterialized Venous Free Flap at the Insufficient Vascular Recipient Bed in Finger Reconstruction)

  • 이영근;박기태;이준모;박혁
    • Archives of Reconstructive Microsurgery
    • /
    • 제21권2호
    • /
    • pp.131-136
    • /
    • 2012
  • Purpose: Arterialized venous flap is useful for reconstruction of the traumatic soft tissue defect in fingers, but insufficient circulation of the traumatic fingers makes surgeons annoying to use the flap. We have grafted flaps in 7 fingers with insufficient vascular bed hoping to expanded the category of the flap. Materials and Methods: Arterialized venous flap have transplanted in 7 fingers from March 2008 through February 2010 and followed up for 4 to 16 months(average 7.2 months). They were all male with a mean age at the time of surgery was 33. The main injury was crushing in 4 degloving, contact burn and saw injury was I respectively. Time interval from injury to flap transplantation was average 3.1. weeks(3 days to 6 weeks). Designed flap size ranges from $8cm{\times}3.5cm$to $4cm{\times}3cm$. Vessel type of flap was one artery with two veins were 5 cases and one artey with one vein 2. Flap type was cutaneous in 3, tendocutaneous 2, neurotendocutaneous 1 and neurocutaneous 1. The circulation state of recipient site was avascular in 2 cases, insufficiency 3 and tip avascular 2. Results: Arterialized venous flap was complete survived in 2 cases, partial necrosis(less than 10%) 3 and failed in 2. Conclusion: An arterialized venous free flap could be a useful procedure for reconstruction in soft tissue or combined defect of the finger despite an avascular or insufficient vascular beds if the recipient beds were free from infection.

  • PDF

Fe와 galvanic couple된 알루미늄의 내식성에 미치는 마그네슘의 영향 (Effects of Mg on corrosion resistance of Al galvanically coupled to Fe)

  • 현영민;김희산
    • Corrosion Science and Technology
    • /
    • 제12권1호
    • /
    • pp.40-49
    • /
    • 2013
  • Effects of magnesium and pH on corrosion of aluminum galvanically coupled to iron have studied by using potentio- dynamic and static tests for polarization curves, Mott-Schottky test for analysis of semiconductor property, and GD-AES and XPS for film analysis. Pitting potential was sensitive to magnesium as an alloying element but not to pH, while passive current was sensitive to pH but not to magnesium. It was explained with, instead of point defect model (PDM), surface charge model describing that the ingression of chloride depends on the state of surface charge and passive film at film/solution interface is affected by pH. In addition, galvanic current of aluminum electrically coupled to iron was not affected by magnesium in pH 8.4, 0.2M citrate solution but was increased by magnesium at the solution of pH 9.1. The galvanic current at pH 9.1 increased with time at the initial stage and after the exposure of about 200 minute, decreased and stabilized. The behavior of the galvanic current was related with the concentration of magnesium at the surface. It agreed with the depletion of magnesium at the oxide surface by using glow discharge atomic emission spectroscopy (GD-AES). In addition, pitting potential of pure aluminum was reduced in neutral pH solution where chloride ion maybe are competitively adsorbed on pure aluminum. It was confirmed by the exponential decrease of pitting potential with log of [$Cl^-$] around 0.025 M of [$Cl^-$] and linear decrease of the pitting potential. From the above results, unlike magnesium, alloying elements with higher electron negativity, lowering isoelectric point (ISE), are recommended to be added to improve pitting corrosion resistance of aluminum and its alloys in neutral solutions as well as their galvanic corrosion resistance in weakly basic solutions.

적외선 열화상 기술을 이용한 복합재료의 결함 검출 정량화 연구 (Study on the Qualitative Defects Detection in Composites by Optical Infrared Thermography)

  • 박희상;최만용;박정학;김원태;최원종
    • 비파괴검사학회지
    • /
    • 제31권2호
    • /
    • pp.150-156
    • /
    • 2011
  • 본 논문에서는 현재 산업 전반에 널리 사용되고 있는 복합재료(탄소섬유강화플라스틱, 유리섬유강화플라스틱)의 비파과검사를 위한 광적외선 열화상기법을 이용한 복합재료 측정 표준기술개발을 위한 결함(인클루젼, 충간결함) 검출 기술을 실험하였다. 결함의 검출률을 높이기 위하여 위상잠금 방법을 활용하였다. 결과는 시험편의 두께에 따라 광원의 조사시간을 늘릴 경우 결함 검출의 확률이 높아진다는 것을 알 수 있다. 하지만 50 mHz 이하의 광원을 가하였을 때에도 결과값이 좋아지지 않는 점은 열확산이 재료 전체에 영향을 미치게 되면 결함 부위가 전체적으로 열평형 상태가 되어 결함 검출이 어려움을 파악할 수 있었다.

Pure Bending이 작용하는 H-Beam의 도입축력 변화에 따른 고장력볼트 연결부 거동 분석 (Analysis on the Sliding Load for Hign-Tension Bolt Joint of the H-Beam in Pure Bending)

  • 김춘호;김상훈
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2006년도 춘계 종합학술대회 논문집
    • /
    • pp.541-544
    • /
    • 2006
  • 고장력볼트에 의한 부재연결 방법 중 가장 대표적인 마찰이음은 사용성 측면에서의 한계상태는 미끄러짐이 발생한 상태라고 할 수 있다. 따라서, 한계상태를 고려한 설계를 위해서는 미끄러짐 내력을 정확히 파악할 필요가 있다. 현재 공용중인 강교에서 발생하는 볼트 연결부의 결함 중 볼트 도입축력 부족의 발생빈도가 가장 크지만 도입축력부족에 따른 결함의 연구는 미비한 상태이다. 따라서 본 연구에서는 고장력 볼트 연결부의 미끄러짐 거동을 파악할 수 있는 모델 제시하기 위하여 범용 유한요소 구조해석 프로그램인 LUSAS를 이용하여 수치해석을 실시하였고, 오직 축력만이 작용하는 표준 시험체와 교량보다 비교적 구조계가 간단한 단순경간 강상형교를 모사한 full-size의 H-Beam시험편을 설계하여 설계볼트 도입축력 100%인 시험편의 도입축력을 기준으로 75%, 50%, 25%의 축력을 도입하여 정적 시험을 실시하여 마찰 문제로 인한 고장력 볼트 연결부의 내력을 수치해석한 결과와 비교 분석하고자 한다.

  • PDF

Effects of Yttria and Calcia Co-Doping on the Electrical Conductivity of Zirconia Ceramics

  • Lee, Jong-Sook;Shin, Dong-Kyu;Choi, Byung-Yun;Jeon, Jung-Kwang;Jin, Sung-Hwan;Jung, Kwon-Hee;An, Pyung-An;Song, Sun-Ju
    • 한국세라믹학회지
    • /
    • 제44권12호
    • /
    • pp.655-659
    • /
    • 2007
  • Zirconia polycrystals co-doped with x mol% CaO and (10-x) mol% $Y_2O_3$ were prepared by solid state reaction method. The compositions were chosen for nominally the same oxygen vacancy concentration of 5 mol%. X-ray diffraction patterns indicated the formation of cubic zirconia by heat treatment at $1600^{\circ}C$. Impedance spectroscopy was applied to deconvolute the bulk and grain boundary response. Electrical conductivity was measured using the complex impedance technique from 516 to 874 K in air. Maximum conductivity was exhibited by the composition with equal amounts of CaO and $Y_2O_3$, which may be ascribed to the smaller degree of defect-interactions in that composition due to the competition of different ordering schemes between the two systems. When compared to the composition containing $Y_2O_3$ only, co-doping of CaO increases the grain boundary resistance considerably. The activation energy of grain and grain boundary conductivity was 1.1 eV and 1.2 eV, respectively, with no appreciable dependence on dopant compositions.

Eu3+-doped A3Al1-zInzO4F (A = Ca, Sr, Ba, z = 0, 0.1)의 합성과 형광특성 (Preparation and Luminescent Property of Eu3+-doped A3Al1-zInzO4F (A = Ca, Sr, Ba, z = 0, 0.1) Phosphors)

  • 김여진;박상문
    • 한국재료학회지
    • /
    • 제21권12호
    • /
    • pp.644-649
    • /
    • 2011
  • [ $A_{3-2x/3}Al_{1-z}In_{z}O_4F:Eu_x^{3+}$ ](A = Ca, Sr, Ba, x = -0.15, z = 0, 0.1) oxyfluoride phosphors were simply prepared by the solid-state method at $1050^{\circ}C$ in air. The phosphors had the bright red photoluminescence (PL) spectra of an $A_{3-2x/3}Al_{1-z}In_{z}O_4F$ for $Eu^{3+}$ activator. X-ray diffraction (XRD) patterns of the obtained red phosphors were exhibited for indexing peak positions and calculating unit-cell parameters. Dynamic excitation and emission spectra of $Eu^{3+}$ activated red oxyfluoride phosphors were clearly monitored. Red and blue shifts gradually occurred in the emission spectra of $Eu^{3+}$ activated $A_3AlO_4F$ oxyfluoride phosphors when $Sr^{2+}$ by $Ca^{2+}$ and $Ba^{2+}$ ions were substituted, respectively. The concentration quenching as a function of $Eu^{3+}$ contents in $A_{3-2x/3}AlO_4F:Eu^{3+}$ (A = Ca, Sr, Ba) was measured. The interesting behaviors of defect-induced $A_{3-2x/3}Al_{1-z}In_{z}O_{4-{\alpha}}F_{1-{\delta}}$ phosphors with $Eu^{3+}$ activator are discussed based on PL spectra and CIE coordinates. Substituting $In^{3+}$ into the $Al^{3+}$ position in the $A_{3-2x/3}AlO_4F:Eu^{3+}$ oxyfluorides resulted in the relative intensity of the red emitted phosphors noticeably increasing by seven times.

NPP 매질내에서 공간주파수 응답을 이용한 초음파 영상의 깊이 분해능 개선을 위한 복원 방법 (The Reconstructive Method for The Enhancement of Depth Resolution for Acoustic Image using the Spatial Frequency Response in NPPs' Material)

  • Koo, Gil-mo;Kim, Hyun;Park, In-ho
    • 한국멀티미디어학회논문지
    • /
    • 제5권4호
    • /
    • pp.426-433
    • /
    • 2002
  • 본 연구에서는 초음파현미경의 동작주파수 변화에 따라서 획득한 영상의 조합을 통하여 얻어진 영상들에 관하여 연구하였다. 고체내부의 영상을 복원하는 경우, 얻어진 영상들은 표면이 상태가 중첩되어 나타나게 된다. 이 경우 위상체 영상들은 내부 영상의 콘트라스트 개선에 활용되어 질 수 있다. 실험에서는 두가지 종류의 시편이 사용되었다. 첫째는 NPP내부에서 스팀 발생장치의 주 파이프의 매질측면에 1/4T, 1/2T, 3/4T의 홀 결함을 갖는 기준 블록이고 다른 시편은 직경이 1-2mm인 반구형태의 시편이다. 실험결과 기본의 영상처리 방법에 비하여 결함 형태에 대한 콘트라스트가 2배 정도의 향상을 보였다. 실험을 위하여 반사신호의 진폭과 위상을 동시에 획득할 수 있는 쿼드러춰 검출기를 사용한 초음파현미경 시스템을 구성하였다. 앞으로는 진폭과 위상영상의 재구성 방법과 결함영상의 콘트라스트를 개선시키기 위한 방법이 계속 연구되어져야겠다.

  • PDF

Determination of the optimal diabetes duration for bone regeneration experiments in an alloxan-induced diabetic rabbit calvarial defect model

  • Jeong, Sang-Hun;Jung, Bo Hyun;Yoo, Ki-Yeon;Um, Heung-Sik;Chang, Beom-Seok;Lee, Jae-Kwan;Choi, Won-Youl
    • Journal of Periodontal and Implant Science
    • /
    • 제48권6호
    • /
    • pp.383-394
    • /
    • 2018
  • Purpose: The purpose of this study was to evaluate the optimal diabetes duration for bone regeneration experiments in an alloxan monohydrate (ALX)-induced diabetic rabbit calvarial defect model by evaluating the association between diabetes duration and bone healing capacity. Methods: Twenty-four New Zealand white rabbits were used. Twenty-two rabbits were injected with 100 mg/kg of ALX to induce experimental diabetes. These rabbits were divided into 4 groups, including a control group and groups with diabetes durations of 1 week (group 1), 2 weeks (group 2), and 4 weeks (group 3). Calvarial defects were created at 1, 2, and 4 weeks after ALX injection and in the control rabbits. Cone-beam computed tomography (CBCT) scanning was performed on the day of surgery and at 2 and 4 weeks after surgery. The rabbits were sacrificed 4 weeks after surgery, followed by histological and immunofluorescence analysis. Results: The diabetic state of all diabetic rabbits was well-maintained throughout the experiment. Reconstructed 3-dimensional CBCT imaging showed more rapid and prominent bone regeneration in the control group than in the experimental groups. Histological staining showed notable bone regeneration in the control group, in contrast to scarce bone formation in the experimental groups. The appearance and immunoreactivity of receptor activator of nuclear factor-kappa B and osteoprotegerin did not show notable differences among the groups. Conclusion: ALX administration at 100 mg/kg successfully induced experimental diabetes in rabbits. The effect of diabetes on bone healing was evident when the interval between diabetes induction and the intervention was ${\geq}1$ week.

Frontotemporal Craniotomy for Clipping of Unruptured Aneurysm Using a Diamond-Coated Thread Wire Saw and Reconstruction Using Calcium Phosphate Cement without Metal Fixation

  • Hiroyuki Koizumi;Daisuke Yamamoto;Hajime Handa;Wakiko Saruta;Satoru Shimizu;Takuichiro Hide;Toshihiro Kumabe
    • Archives of Plastic Surgery
    • /
    • 제50권3호
    • /
    • pp.248-253
    • /
    • 2023
  • Metal fixation systems for cranial bone flaps cut by a drill are convenient devices for cranioplasty, but cause several complications. We use modified craniotomy using a fine diamond-coated threadwire saw (diamond T-saw) to reduce the bone defect, and osteoplasty calcium phosphate cement without metal fixation. We report our outcomes and tips of this method. A total of 78 consecutive patients underwent elective frontotemporal craniotomy for clipping of unruptured intracranial aneurysms between 2015 and 2019. The follow-up periods ranged from 13 to 66 months. The bone fixation state was evaluated by bone computed tomography (CT) and three-dimensional CT (3D-CT). The diamond T-saw could minimize the bone defect. Only one wound infection occurred within 1 week postoperatively, and no late infection. No pain, palpable/cosmetically noticeable displacement of the bone flap, fluid accumulations, or other complications were observed. The condition of bone fixation and the cosmetic efficacy were thoroughly satisfactory for all patients, and bone CT and 3D-CT demonstrated that good bone fusion. No complication typical of metal fixation occurred. Our method is technically easy and safety, and achieved good mid-term bone flap fixation in the mid-term course, so has potential for bone fixation without the use of metal plates.