• Title/Summary/Keyword: Defect Repair

Search Result 592, Processing Time 0.022 seconds

A STUDY OF EFFECTS OF BONE MORPHOGENETIC PROTEIN BONE REGENERATION OF IMPLANTS IN DOGS (성견에서 임프란트 매식시 골형성단백 사용에 따른 골재생에 관한 연구)

  • Jo Jin-Hee;Vang Mong-Sook;Lee Jong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.4
    • /
    • pp.593-607
    • /
    • 1994
  • The purpose of this study is to evaluate the effect of the bone morphogenetic protein, bone matrix gelatin and collagen matrix on the amount and shape of generating new bone adjacent to the implant. Implants were inserted in the mandible of adult dogs at 2 months after teeth extraction. Artificial bony defects, 3mm in width and 4mm in depth were made at the mesial and distal side of implant. Experimental groups were divided into three groups ; Group 1 : Defects filled with collagen matrix and bone morphogenetic protein, Group 2 : Defects filled with bone matrix gelatin. Control group : Defects filled with only collagen matrix. After implantation, the animals were sacrificed at 1,3,5 and 10 weeks for light microscopic examination. For the fluorescent microscopic examination. each tertracycline Hcl and calcein were injected at 1, 3, 5, 8 and 10 weeks after implantation. The results obtained were as follows : 1. The molecular weight of bovine BMP was about 18,100 by hydroxyapatite chromatography. 2. Osseointegration was observed in experimental groups 1 & 2, and BMG and BMP had an excellent bone forming capability as a filling materials to the repair of the bone defects. 3. The degree of healing of bone defect area, the experimental group 1 showed more prominent bone formation than control group, and the control group showed fibrous connective tissue between the implant and the bone. 4. In the fluorescent microscopic findings, bone remodelling was observed regenerative lamellar bone at defect area in experimental group 1, and partial remodelling in experimental group 2, In the control group, fibrous connective tissue was observed between the implant and bone surface and sign of remodelling was not apperaed. Above results suggest that BMP has rapid osteoinductive property and can be used clinically as a bone substitute on bone defects around implants.

  • PDF

Repair of Coarctation (including tubular hypoplasia) in Infancy and Children (영아 및 소아 연령에서의 대동맥 교약증의 교정 수술)

  • 한재진
    • Journal of Chest Surgery
    • /
    • v.23 no.3
    • /
    • pp.474-481
    • /
    • 1990
  • We have experienced 44 cases of coarctation of aorta in the age of infancy and children from April 1986 to September 1989 at Seoul National University Children`s hospital. Patients were thirty males and fourteen females, and their age ranged from one month to ten years[mean 23.84 $\pm$33.06 months] with thirty-two infant cases. In the infantile age, congestive heart failure was the most common chief complaint[18/32], and above that age, frequent upper respiratory infection was most common[8/12]. We experienced thirteen cases of isolated COA, twenty-two cases of COA with VSD, eight cases of COA with VSD, eight cases of COA with intracardiac complex anomalies and one case of COA with atrial septal defect. The associated intracardiac complex anomalies were three Taussig-Bing type double outlet right ventricle, one single ventricle, one transposition of great arteries, one atrioventricular septal defect, one hypoplastic aortic arch with left heart hypoplasia, and one Tetralogy of Fallot. Operative techniques of COA were twenty-three subclavian flap arterioplasty, 12 resection and end to end anastomosis, eight onlay patch angioplasty, and I direct angioplasty after resection of web. Among the cases with other cardiac anomalies, staged operation was done in twenty-nine patients, and single stage total correction was performed only in three patients. There were seven operative mortality[15.9%], all being in infantile age group, and among fourteen cases associated with large VSD[Qp/Qs>2.0, mean pulmonary arterial pressure>50mmHg], four patients were died, but there was no mortality in patients with small VSD. With above results, we are intended to discuss about the interval between staged operation, the fate of VSD after coarctoplasty in case of COA with VSD, causes of death, complications etc.

  • PDF

PAUT-based defect detection method for submarine pressure hulls

  • Jung, Min-jae;Park, Byeong-cheol;Bae, Jeong-hoon;Shin, Sung-chul
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.2
    • /
    • pp.153-169
    • /
    • 2018
  • A submarine has a pressure hull that can withstand high hydraulic pressure and therefore, requires the use of highly advanced shipbuilding technology. When producing a pressure hull, periodic inspection, repair, and maintenance are conducted to maintain its soundness. Of the maintenance methods, Non-Destructive Testing (NDT) is the most effective, because it does not damage the target but sustains its original form and function while inspecting internal and external defects. The NDT process to detect defects in the welded parts of the submarine is applied through Magnetic particle Testing (MT) to detect surface defects and Ultrasonic Testing (UT) and Radiography Testing (RT) to detect internal defects. In comparison with RT, UT encounters difficulties in distinguishing the types of defects, can yield different results depending on the skills of the inspector, and stores no inspection record. At the same time, the use of RT gives rise to issues related to worker safety due to radiation exposure. RT is also difficult to apply from the perspectives of the manufacturing of the submarine and economic feasibility. Therefore, in this study, the Phased Array Ultrasonic Testing (PAUT) method was applied to propose an inspection method that can address the above disadvantages by designing a probe to enhance the precision of detection of hull defects and the reliability of calculations of defect size.

MRI Findings of the Repaired Anterior Cruciate Ligament (전방 십자 인대의 일차 봉합술 후 MRI 소견)

  • Kim, Jung-Man;Koh, In-Jun;Lee, Dong-Yeob;Lee, Yoon-Min
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.1
    • /
    • pp.14-21
    • /
    • 2009
  • Purpose: To investigate MRI findings of the repaired anterior cruciate ligament (ACL). Materials and Methods: Seventeen of arthroscopic ACL primary repair with sutures pull-out technique were followed for 21.4 months (range: 12 to 60 months). Stability was assessed with physical examination and KT-1000 arthrometer (MED metric, San Diego, CA) and postoperative MRI checked with time. The patients were divided into 2 groups according to the location of tear which was defined with the location of remained synovial sleeve. Group I (11 patients) comprised that the tear was located within proximal 1/3 of ACL substance and group II (6 patients) comprised below proximal 1/3. MRI findings of the repaired ACL were evaluated by its course, sharpness, thickness and signal intensity using 3 grade system and correlated with its location of tear. Results: In all cases, Lachman test and flexion-rotation drawer test were negative, pivot-shift test was less than grade 1 and the mean side-to-side difference by use of KT-1000 arthrometer was 1.4 mm (range: -1.0 to 2.5 mm). The overall continuity of the repaired ACL was well maintained in all cases. However, mild sagging was observed in 10 cases(58.8%), mild obscure contour in 6 cases (35.3%), increased thickness in 8 cases (47.1%) and slight increased signal intensity in 5 cases (29.5%). There was no statistical significance in all parameters between 2 groups. And a focal defect at the femoral attachment site in sagittal image was observed in 7 cases (41.2%) of all patients which comprised 2 cases (18.2%) of group I and 5 cases (83.3%) of group II. It was observed more frequently in group II with statistical significance (p=0.035). Conclusion: Some abnormal MRI findings such as mild sagged course, obscure contour, increased thickness and signal intensity, the focal defect at femoral attachment site could be observed even though the stability was well maintained clinically. We thought that the focal defect was affected by the location of tear of ACL.

  • PDF

A Study on the Improvement Plan through Analyzing the Perception of Expert Group about Landscape Construction Defects (조경공사 하자에 관한 전문가 집단간 인식분석을 통한 개선방안 연구)

  • Lee, Sang-Suk;Yu, Joo-Eun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.4
    • /
    • pp.104-113
    • /
    • 2012
  • This study aimed to find out the improvement plan through analyzing the perception of the expert group engaged in landscape architectural construction and to focus on analyzing the expert groups' experience on Landscape Construction Defects (LCD), defect liability, warranty period, and implementation of the defect liability. The results are as follows: 1. Regarding the experience on the LCD, landscape construction contractors were an awareness of the LCD issue at a serious level, while public-sector clients recognize moderately the LCD issue; and on the first priority in defect implementation, landscape construction contractors considered repair cost while public-sector clients value the identifying causes of defects. 2. In disagreement on the defect liability, landscape construction contractors attributed it to client's lack of responsibility for maintenance while public-sector clients ascribed it to the absence of dealing a criteria with LCD, and regarding the appropriate defect implementation, public-sector clients preferred the following objective by dealing the criteria with LCD while landscape construction contractors advocates by sharing the responsibilities for dealing with LCD based on the identified causes of construction defects. 3. Regarding the warranty period, the public-sector clients considered the 2-year warranty period as appropriate while landscape construction contractors considered it comparatively long, and concerning the commencement of defect warranty period, the public-sector clients viewed it as it should commence to cover the overall completion of the construction while landscape construction contractors perceived it to start on the completion of each work. 4. As for the improvement of the defect implementation system, public-sector clients considered it necessary to establish the objective dealing the criteria with LCD while landscape construction contractors viewed the legislation of maintenance duty. Also, with regard to the important value in establishing and dealing the criteria with LCD, public-sector clients pointed out the objective of the criteria for determining the defects per work type while landscape construction contractors suggested client (user)'s maintenance duty. Because of research, because the system in dealing with LCD is an absence of LCD management agency and dealing the criteria with LCD, it is needed to establish an LCD management agency and make the system in dealing with LCD.

The healing effect of platelet-rich plasma on xenograft in peri-implant bone defects in rabbits

  • Peng, Wang;Kim, Il-kyu;Cho, Hyun-young;Seo, Ji-Hoon;Lee, Dong-Hwan;Jang, Jun-Min;Park, Seung-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.16.1-16.9
    • /
    • 2016
  • Background: The association of biomaterial combined with repair factor-like platelet-rich plasma (PRP) has prospective values. Bovine-derived xenograft has been identified as an osteoconductive and biocompatible grafting material that provides osseointegration ability. PRP has become a valuable adjunctive agent to promote healing in a lot of dental and oral surgery procedures. However, there are controversies with respect to the regenerative capacity of PRP and the real benefits of its use in bone grafts. The purpose of this study was to assess the influence of PRP combined with xenograft for the repair of peri-implant bone defects. Methods: Twelve rabbits were used in this study, and the experimental surgery with implant installation was performed simultaneously. Autologous PRP was prepared before the surgical procedure. An intrabony defect (7.0 mm in diameter and 3.0 mm deep) was created in the tibia of each rabbit; then, 24 titanium dental implants (3.0 mm in diameter and 8.5 mm long) were inserted into these osteotomy sites. Thus, a standardized gap (4.0 mm) was established between the surrounding bony walls and the implant surface. The gaps were treated with either xenograft alone (control group) or xenograft combined with PRP (experimental group). After healing for 1, 2, 3, 4, 5, and 6 weeks, the rabbits were sacrificed with an overdose of KCl solution. Two rabbits were killed at each time, and the samples including dental implants and surrounding bone were collected and processed for histological analysis. Results: More newly formed bone and a better bone healing process were observed in control group. The histomorphometric analysis revealed that the mean percentage of bone-to-implant contact in the control group was significantly higher than that of the experimental group (25.23 vs. 8.16 %; P < 0.05, independent-simple t test, analysis of variance [ANOVA]). Conclusions: The results indicate that in the addition of PRP to bovine-derived xenograft in the repair of bone defects around the implant, PRP may delay peri-implant bone healing.

Biventricular Repair of Critically III Neonate with Ebstein′s Anomaly - Report of 1 case - (증상이 심한 신생아 Ebstein 기형의 양심실성교정 -1례 보고-)

  • Kong, Joon-Hyuk;Kim, Woong-Han;Ryu, Jae-Wook;Lee, Seog-Ki;Baek, Man-Jong;Lim, Cheong;Kim, Soo-Cheol;Oh, Sam-Se;Na, Chan-Young;Kim, Soo-Jin;Park, Young-Kwan;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.35 no.4
    • /
    • pp.303-306
    • /
    • 2002
  • Patients with severe Ebstein's anomaly showing in the neonatal period, represent progressive cardiac enlargement with pulmonary hypoplasia and functional pulmonary atresia with patent ductus alteriosus-dependent pulmonary circulation. Biventricular repair in these patients had been mostly unsuccessful except for Starnes' procedure that converts the anatomy to single ventricle physiology for Fontan procedure. A 4-days old male was admitted with the diagnosis of severe Ebstein's anomaly with anatomic pulmonary atresia and severe cardiac enlargement. He successfully underwent biventricular repair with vertical plication method of atrialized right ventricle, tricupid annuloplasty, transannular right ventricular outflow tract reconstrulltion, atrial septal defect patch closure with fenestration, and right atrial reduction angioplasty Postoperatively, cardiothoracic ratio was significantly reduced and mild tricuspid regurgitation was remnant in echocardiography. The patient is currently 10 months old and is fully active without restrictions.

Risk Analysis of the Long-Term Outcomes of the Surgical Closure of Secundum Atrial Septal Defects

  • Kim, Hong Rae;Jung, Sung-Ho;Park, Jung Jun;Yun, Tae Jin;Choo, Suk Jung;Chung, Cheol Hyun;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • v.50 no.2
    • /
    • pp.78-85
    • /
    • 2017
  • Background: Closure of a secundum atrial septal defect (ASD) is possible through surgical intervention or device placement. During surgical intervention, concomitant pathologies are corrected. The present study was conducted to investigate the outcomes of surgical ASD closure, to determine the risk factors of mortality, and establish the effects of concomitant disease correction. Methods: Between October 1989 and October 2009, 693 adults underwent surgery for secundum ASD. Their mean age was $40.9{\pm}13.1years$, and 199 (28.7%) were male. Preoperatively, atrial fibrillation was noted in 39 patients (5.6%) and significant tricuspid regurgitation (TR) in 137 patients (19.8%). The mean follow-up duration was $12.4{\pm}4.7years$. Results: There was no 30-day mortality. The 1-, 5-, 10-, and 20-year survival rates were 99.4%, 96.8%, 94.5%, and 81.6%, respectively. In multivariate analysis, significant preoperative TR (hazard ratio [HR], 1.95; 95% confidence interval [CI], 1.09 to 3.16; p=0.023) and preoperative age (HR, 1.04; 95% CI, 1.01 to 1.06; p=0.001) were independent risk factors for late mortality. The TR grade significantly decreased after ASD closure with tricuspid repair. However, in patients with more than mild TR, repair was not associated with improved long-term survival (p=0.518). Conclusion: Surgical ASD closure is safe. Significant preoperative TR and age showed a strong negative correlation with survival. Our data showed that tricuspid valve repair improved the TR grade effectively. However, no effect on long-term survival was found. Therefore, early surgery before the development of significant TR mat be beneficial for improving postoperative survival.

Clinical Experience of Currarino Syndrome (큐라리노 증후군의 임상 경험)

  • Kim, Tae-Hoon;Cho, Min-Jeong;Kim, Dae-Yeon;Kim, Seong-Chul;Kim, In-Koo
    • Advances in pediatric surgery
    • /
    • v.17 no.1
    • /
    • pp.65-71
    • /
    • 2011
  • Currarino syndrome is a hereditary syndrome characterized by the triad of a sacral bony defect, presacral mass and anorectal malformation. We retrospectively reviewed 13 Currarino syndrome patients who were treated in our center between 1997 and 2010. Demographic data, initial symptoms, initial diagnosis. pathologic diagnosis of presacral mass, associated anomalies and managements were analyzed. There were 8 boys and 5 girls. Four patients were diagnosed as Currarino syndrome immediately after birth with failure of passage of meconium and abdominal distension. Four patients underwent surgery for imperforate anus immediately after birth and W8re diagnosed as Currarino syndrome later and underwent reoperation. Three patients were diagnosed during work-up and management with of the tentative diagnosis of Hirschsprung's disease. Diagnosis of the remaining two patients was at the age of 26 months and 9 years and anorectal malformation was not associated. Twelve patients showed hemi-sacrum and one patient showed bilateral sacral subtotal agenesis. Two patients without anorectal malformation underwent presacral mass excision, untethering of spinal cord and repair of myelomeningocele. Six out of 8 patients, excluding 3 that expired or were lost to follow up, with anorectal malformation underwent colostomy, presacral mass excision, untethering of spinal cord, repair of myelomeningocele, posterior sagittal anorectoplasty and colostomy repair. One patient underwent only posterior sagittal anorectoplasty after colostomy. One waits the scheduled operation only with Hegar dilatation. Pathologic examation of presacral masses showed myelomeningoceles in 4 patients, lipomyelomeningoceles in 3 patients and dermoid Cyst in one patient. Teratoma was combined in 2 patients. Eight patients needed neurosurgical operation for spinal cord problems. Seven patients had urologic anomalies and two of them underwent operation. Currarino syndrome should be considered as a differential diagnosis in pediatric patients with abdominal distension, constipation and anorectal malforlnation. For proper evaluation and treatment, a multi-disciplinary approach is recommended.

  • PDF

Failure Characteristics of Scarf Patch-repaired Composite Single-lap Joints (스카프 패치로 수리한 복합재 단일겹침 체결부의 파손 특성 연구)

  • Kim, Choong-Hyun;Yoo, Jae-Seung;Byeon, Chang-Seok;Ju, Hyun-Woo;Park, Min-Young;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.29 no.3
    • /
    • pp.117-124
    • /
    • 2016
  • The failure strength of composite single-lap joint repaired using scarf patch was investigated by test and finite element method. A total of 45 specimens were tested changing scarf ratio, stacking pattern, and defect size to study the failure strength and mode. Except for one case, all repaired specimens showed the equal or higher strength than the sound specimens and the effect of considered repair parameters was not remarkable. It was found through the failure mode inspection that the surface treatment for bonding was not enough in the case which failed at the lower load than the sound specimen. Three-dimensional finite element analysis was conducted to verify the test results. It was confirmed that the considered repair parameters do not significantly affect the stress distribution of the specimens. It was also observed that the applied tensile load is relieved passing through the overlapped region thickness of which is almost double. From this study, it is concluded that if the bonding procedure for adherends and patch including surface treatment for fabric layer is thoroughly followed, the strength of repaired single-lap joint can be restored up to the strength of sound one.