• Title/Summary/Keyword: Defect Rate

Search Result 892, Processing Time 0.034 seconds

The Development of Automatic Inspection System for Flaw Detection in Welding Pipe (배관용접부 결함검사 자동화 시스템 개발)

  • Yoon Sung-Un;Song Kyung-Seok;Cha Yong-Hun;Kim Jae-Yeol
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.2
    • /
    • pp.87-92
    • /
    • 2006
  • This paper supplements shortcoming of radioactivity check by detecting defect of SWP weld zone using ultrasonic wave. Manufacture 2 stage robot detection systems that can follow weld bead of SWP by method to detect weld defects of SWP that shape of weld bead is complex for this as quantitative. Also, through signal processing ultrasonic wave defect signal system of GUI environment that can grasp easily existence availability of defect because do videotex compose. Ultrasonic wave signal of weld defects develops artificial intelligence style sightseeing system to enhance pattern recognition of weld defects and the classification rate using neural net. Classification of weld defects that do fan Planar defect and that do volume defect of by classify.

Clinical evaluation of atrial septal defect (심방중격결손증의 외과적 고찰)

  • Kim, Hyeon-Sun;Seo, Gyeong-Pil
    • Journal of Chest Surgery
    • /
    • v.16 no.4
    • /
    • pp.511-517
    • /
    • 1983
  • For the purpose of clinical analysis of secundum atrial septal defect, the patients with atrial septal defect operated on during the period from Aug. 1959 to Aug. 1983 were analysed. The age of the patients was ranged from 3 months to 60 years and there were 132 males [45.3%] patients and 145 female patients [54.6%] in this series. The most frequent type was oval type defect in 219 [86.9%]. The PAPVC were present in 7 patients of high defect group. Clinical analysis revealed 53 patients [19.9%] were asymptomatic. The QP/QS above than 3.61 were 45 patients and less than 1.5 were 24 patients. The pulmonary artery pressure was 10 to 100 mmHg. The majority of the defects were closed in primary suture and closed with a Dacron patch in 19 patients. The postoperative complications occurred in 35 patients [13.1%] and the most frequent complication was wound problem which was present in 10 patients. The hospital mortality rate was 1.6%.

  • PDF

Performance improvement of Classification of Steam Generator Tube Defects in Nuclear Power Plant Using Neural Network (신경회로망을 이용한 원전SG 세관 결함패턴 분류성능 향상기법)

  • Jo, Nam-Hoon;Han, Ki-Won;Song, Sung-Jin;Lee, Hyang-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1224-1230
    • /
    • 2007
  • In this paper, we study the classification of defects at steam generator tube in nuclear power plant using eddy current testing (ECT). We consider 4 defect patterns of SG tube: I-In type, I-Out type, V-In type, and V-Out type. Through numerical analysis program based on finite element modeling, 400 ECT signals are generated by varying width and depth of each defect type. In order to improve the classification performance, we propose new feature extraction technique. After extracting new features from the generated ECT signals, multi-layer perceptron is used to classify the defect patterns. Through the computer simulation study, it is shown that the proposed method achieves 100% classification success rate while the previous method yields 91% success rate.

$H_2$ gas flow rate가 비정질 실리콘 박막 태양전지의 i-layer에 미치는 영향에 대한 simulation

  • Park, Seung-Man;Gong, Dae-Yeong;Lee, Won-Baek
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.303-303
    • /
    • 2010
  • 비정질 실리콘 박막 태양전지의 수광부인 i-layer는 비정질의 특성 상 많은 defect을 함유하고 있다. 이러한 defect들은 빛에 의하여 생성된 전자정공 재결합에 있어서 주도적으로 작용하게 된다. $H_2$는 이러한 defect들의 생성을 줄여주어 박막의 특성을 향상시켜주는 것으로 알려져 있다. 본 논문에서는 비정질 박막 태양전지의 수광부로 사용되어지는 i-layer의 $H_2$ gas flow rate의 변화에 따른 태양전지의 특성을 simulation해 보았다. $H_2$는 1:0에 1:5까지 변화시켰고 그에 따른 태양전지의 QE, LIV, DIV 곡선을 통하여 특성을 알아보았다. 또한 추가적으로 i-layer의 두께에 따른 효율의 변화도 simulation해 보았다.

  • PDF

A study on the reduction of blow hole defects in aluminum sand casting (알루미늄 사형주조에서 기공 결함 감소를 위한 연구)

  • Lee, Dong-Youn;Lee, Chun-Kyu
    • Design & Manufacturing
    • /
    • v.14 no.4
    • /
    • pp.52-57
    • /
    • 2020
  • In this study attempted to prevent defects due to blow holes among defects of sand casting products. It was intended to reduce the defect rate by reducing the blow hole of the inner surface. Currently, expectations and requirements for the quality level of non-ferrous aluminum casting in the casting industry are increasing. In addition, the shape is complex and the shrinkage precision is required. Among them, the test prototype is expensive to manufacture the mold, and the production time is also long, and the product is manufactured by sand casting. At this time, the highest defect rates are defects caused by shrinkage defects, surface defects, and blow holes.. At this study, the manufacturing time was shortened by using the shape of the fluid movement path in advance. Also, it is possible to reduce defects due to blow holes.

An Analysis of Permanantly Shaded Areas and the Defect Rate of Landscape Trees in Apartment Complexes Using Daylight Simulations

  • Park, Sang Wook
    • Journal of People, Plants, and Environment
    • /
    • v.23 no.3
    • /
    • pp.333-345
    • /
    • 2020
  • Background and objective: The purpose of this study was to provide basic data on trees that can be used for planting design and construction for permanently shaded areas by grasping the growth status of trees according to the daylight conditions of the outdoor spaces of apartment complexes. Methods: On the recently completed apartment complexes, daylight conditions were analyzed by using daylight simulations utilizing Solar Access Analysis of Ecotect Analysis. With a criteria for assessment of tree condition, the defect rate of trees planted in permanently shaded areas and green spaces with good daylight conditions was analyzed to suggest trees applicable to permanently shaded areas. The first tree survey was conducted from November 18, 2019 to February 15, 2020, focusing on trees planted in permanently shaded areas, and the second tree survey of all the trees planted on the study sites including permanently shaded areas was conducted from March 16 to March 30, 2020. Results: Evergreen trees which are classified as shade intolerant trees including Pinus densiflora, Thuja occidentalis, and Abies holophylla showed a higher defect rate of trees among the trees planted in permanently shaded areas. Taxus cuspidata, Zelkova serrata, Cornus kousa, Chionanthus retusus and Acer palmatum which are classified as shade tolerant trees and shade moderate tolerance trees seemed to be able to be used in the plant design of permanently shaded areas in apartment complexes because the trees showed good growth and a low tree defect rate. In addition, although it was excluded from the analysis due to a small number of samples, Sorbus commixta and Prunus cerasifera var. atropurpurea also can be used for planting in permanently shaded areas. Conclusion: The daylight simulation technique used to analyze permanent shaded areas in this study can be used as an analysis tool considering the daylight environment at the stages of design and construction, and additional research will be required to analyze tree growth according to daylight conditions through data accumulation and monitoring by managing records throughout the entire life cycle of trees in the process of planting and maintenance.

Analysis of Defect in CANDU Feeder Pipe using Phased Array Ultrasonic Inspection System (냉각재 공급자관 위상배열 검사 적용에 따른 결함 분석)

  • Lee, Sang-Hoon;Jin, Seuk-Hong;Kim, In-chul
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.1
    • /
    • pp.78-82
    • /
    • 2010
  • The feeder pipe of Main Primary Heat Transfer System in Wolsong Nuclear Power Plant was inspected by the Ultrasonic Phase Array technique in 2010. It is the first time to apply this method to the construction at Nuclear Power Plant in Korea. The time required for UT technique is less than RT method. The UT method doesn't need to evacuate personnel who works nearby inspecting area and doesn't need to wait developing of film. For these reasons, the UT method is the fastest method among the volumetric inspections. As a result of the examination, it became clear that main defect of the feeder pipe is the Lack of fusion in the welded area. Moreover, the rate of defect was reduced gradually as improvement of welder's skill. If welding machine has problem, the defect has tended to same pattern(occurred same position in the welding area) but these defects were founded without specific rules. For these reasons, the creation of defect is dependent on the skill of worker not on the automatic welding machine. This evaluation of defect signal and collecting data would be useful to further examination in ISI.

  • PDF

Relation Between Defect State and Negative Ultra-Violet Photoresponse from n-ZnO/p-Si Heterojunction Diode

  • Jo, Seong-Guk;Nam, Chang-U;Kim, Eun-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.191.2-191.2
    • /
    • 2013
  • The negative photoconductivity was frequently observed in some semiconductors. It was known that the origin of the negative photoresponse from ZnO is molecular chemisorption or the charging effect of nanoparticles in bulk matrix. However, the origin of the negative photoresponse of thin film was not still clear. One of possible explanation is due to the deep level trap scheme, which describes the origin of the negative photoresponse via defect state under illumination of light. However, the defect states below Fermi level have high capture rate by Coulomb effect, so that these states are usually filled by electrons if the defect states have donor-like character. Therefore the condition which the defect states located in below Fermi level should be partially filled by electrons make more difficult to understand of mechanism of the negative photoresponse. In this study, n-ZnO/p-Si heterojunction diodes were fabricated by UHV RF magnetron sputter. Then, some diodes show the negative photoresponse under ultra-violet light illumination. The defect state of the ZnO was analyzed by photoluminescence and deep level transient spectroscopy. To interpret the negative photoconductivity, band diagram was simulated by using SCAPS program.

  • PDF

A Study on Growth Characteristics of the Surface Fatigue Crack Propagated from a Small Surface Defect in Carbon Steels (탄소강재(炭素鋼材)의 작은 표면결함(表面缺陷)에서 성장(成長)하는 표면피로(表面疲勞)균열의 성장특성(成長特性)에 관한 연구(硏究))

  • Chang-Min,Suh;Yong-Goo,Kang
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.21 no.1
    • /
    • pp.35-42
    • /
    • 1984
  • In the present study, rotating bending fatigue tests have been carried out in three kinds of carbon steel specimens; an annealed low carbon steel, an annealed high carbon steel and quenched-tempered high carbon steel; with a small artificial surface defect that might exist in real structures. Fatigue crack lengths have been observed by a method of replication in order to investigate the growth characteristic of fatigue crack in the viewpoints of strength of materials and fracture mechanics. The main results obtained are as follows: 1) The effect of a small surface defect upon the reduction of fatigue limit is considerably large, and the rate of fatigue limit reduction grows in the following order; annealed low carbon steel(mild steel), annealed high carbon steel, quenched-tempered high carbon steel. 2) When the growth rate of surface crack length(2a) was investigated in the viewpoints of fracture mechanics based upon $ ${\Delta}K_{\varepsilon}$, the dependence of stress level and of surface defect size disappear, and there exists a linear relationships between d(2a)/dN and ${\Delta}K_{{\varepsilon}t},\;\Delta_{{\varepsilon}t}\sqrt{{\pi}a}$, on log. plot, i.e, $d(2a)/dN={C{\cdot}{\Delta}K_{\varepsilon}}^3_t$, where ${\Delta}_{{\varepsilon}t}\sqrt{{\pi}a}$ a is the cyclic total strain intensity factor range.

  • PDF

Clinical Study of Ventricular Septal Defect (심실중격결손의 임상적 고찰)

  • Kim, Gyu-Tae;Lee, Jong-Tae;Lee, Jae-Seong
    • Journal of Chest Surgery
    • /
    • v.18 no.2
    • /
    • pp.157-164
    • /
    • 1985
  • Our series comprised 68 patients of ventricular septal defect who underwent open heart surgery at the Department of Thoracic and Cardiovascular Surgery, School of Medicine, Kyungpook National University, from January, 1980 to September, 1984. Of the 68 patients, 47 patients were male [69.1%] and 21 patients were female [30.9%]. Their age ranged from 3 years to 27 years, and the mean age was 10.1 years. Upon Kirklin`s anatomical classification, type I constituted 29.4%, type II 69.1%, type III 1.5%, and type IV 1%. The cardiac anomalies associated with ventricular septal defect were 21 in all; 5 PS, 4 Aortic insufficiency, 2 ASD, 4 Patent foramen ovale, and 1 Patent ductus arteriosus. Upon the data of cardiac catheterization, most of the patients had Qp/Qs of 1.4-1.8, Pp/Ps of 0.25 or less and Rp/Rs of 0.25 or less. There was no significant correlationship between the rate of operative complication & mortality and the increase of Qp/Qs, Pp/Ps, and Rp/Rs. The values of Qp/Qs, Pp/Ps and Rp/Rs were correspondingly increased according to increment of the defect size. 20 patients developed postoperative complications, such as 4 acute respiratory failure, 3 reexploration due to massive bleeding, 1 low cardiac output, 1 patch detachment, and 2 air embolism. Operative mortality rate was 7.4% [5 cases] among 68 patients.

  • PDF