• Title/Summary/Keyword: Defect Possibility

Search Result 219, Processing Time 0.028 seconds

Self-assembly of Helical structure by defected nanosheet

  • Yoon, Sang-hee;Sim, Eunji
    • Proceeding of EDISON Challenge
    • /
    • 2016.03a
    • /
    • pp.75-79
    • /
    • 2016
  • A helical nanosturctrue can be obtained by self-assembly method. Utilizing DPD simulation coarse-grained model, we patterned 2D layer nanosheets with repeated diagonal defects and grafts, and programed to self-roll into hollow helix structure. The defected pattern side caused anisotropy, and formed helix or helix-like structure. This opens the possibility to control the helix pitch or cavity radius. In this work, we designed several patterns about diagonal defect with a variety of defect side densities and defect widths and then simulation was carried out. Thus, our results have that parameters are affecting self-assembly of nanosheets and their conformation.

  • PDF

Ankle Salvage Procedure without Internal Fixation for Large Bone Defect after Failed Total Ankle Arthroplasty: A Case Report (실패한 족관절 인공관절 치환술 후 큰 골결손에서 내고정 없이 시행한 족관절 구제술: 증례 보고)

  • Park, Man-Jun;Eun, Il-Soo;Jung, Chul-Young;Ko, Young-Chul;Yoo, Chong-Il;Kim, Min-Woo;Hwang, Keum-Min
    • Journal of Korean Foot and Ankle Society
    • /
    • v.18 no.2
    • /
    • pp.76-79
    • /
    • 2014
  • In treatment of failure in ankle joint replacement therapy, talar avascular necrosis with massive bone defect, talus fracture with severe comminution and bone defect and ankle dislocation, treatment of large bone defects is considerably important for ankle joint stability and union, therefore, the choice of treatment for large bone defects is use of femoral head or iliac crest bone graft and rigid internal fixation. Because first generation total ankle arthroplasty performed for the first time using a cemented fixation technique requires a large amount of bone resection during re-surgery and there is some possibility of a larger bone defect after removal of implants, in cases where prosthesis for the defect is needed, performance of palliative femoral head or iliac crest bone graft and rigid internal fixation can be difficult. We report on a case of a 48-year-old woman who had experienced ankle pain for 25 years since undergoing total ankle arthroplasty. Because the patient had little ankle motion and rigid soft tissue despite a large bone defect caused by aseptic loosening, a good outcome was obtained only for the femoral cancellous bone graft using allo femoral head without internal fixation.

Numerical Analysis of Effects of Mold Cavity Shape on Bubble Defect Formation in UV NIL (UV NIL공정에서 몰드 중공부 형상과 기포결함에 대한 수치해석)

  • Lee, Hosung;Kim, Bo Seon;Kim, Kug Weon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.596-602
    • /
    • 2018
  • Nanoimprint lithography (NIL) is an emerging technology that enables cost-effective and high-throughput nanofabrication. In ultraviolet (UV) NIL, low-cost and high-speed production can be achieved using a non-vacuum environment at room temperature and low pressure. However, there are problems with the formation of bubble defects in such an environment. This paper investigates the shape of the mold cavity and the bubble defect formation in UV NIL in a non-vacuum environment. The bubble defect formation was simulated using two-dimensional flow analysis and the VOF method for commonly used cavity mold shapes (rectangular, elliptical, and triangular). The characteristics of the resist flow front and various contact angles were also analyzed. The shape of the mold cavity had a very significant effect on the bubble defect formation. For all cavity shapes, a smaller contact angle with the mold and larger contact angle with the substrate decreased the possibility of bubble defect formation. The elliptical shape was the most effective for preventing bubble defect formation.

Reconstruction of cheek mucosal defect with a buccal fat pad flap in a squamous cell carcinoma patient: a case report and literature review

  • Hwang, Dae-Seok;Park, Jinyoung;Kim, Uk-Kyu;Park, Hae-Ryoun;Kim, Gyoo-Cheon;Ryu, Mi-Heon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.11.1-11.5
    • /
    • 2018
  • Background: Squamous cell carcinoma (SCC) is the most commonly occurring malignant tumor in the oral cavity. In South Korea, it occurs most frequently in the mandible, tongue, maxilla, buccal mucosa, other areas of the oral cavity, and lips. Radial forearm free flap (RFFF) is the most widely used reconstruction method for the buccal mucosal defect. The scar of the forearm donor, however, is highly visible and unsightly, and a secondary surgical site is needed when such technique is applied. For these reasons, buccal fat pad (BFP) flap has been commonly used for closing post-surgical excision sites since the recent decades because of its reliability, ease of harvest, and low complication rate. Case presentation: In the case reported herein, BFP flap was used to reconstruct a cheek mucosal defect after excision. The defect was completely covered by the BFP flap, without any complications. Conclusion: Discussed herein is the usefulness of BFP flap for the repair of the cheek mucosal defect. Also, further studies are needed to determine the possibility of using BFP flap when the defect is deep, and the maximum volume that can be harvested considering the changes in volume with age.

A Study of Pattern Defect Data Augmentation with Image Generation Model (이미지 생성 모델을 이용한 패턴 결함 데이터 증강에 대한 연구)

  • Byungjoon Kim;Yongduek Seo
    • Journal of the Korea Computer Graphics Society
    • /
    • v.29 no.3
    • /
    • pp.79-84
    • /
    • 2023
  • Image generation models have been applied in various fields to overcome data sparsity, time and cost issues. However, it has limitations in generating images from regular pattern images and detecting defects in such data. In this paper, we verified the feasibility of the image generation model to generate pattern images and applied it to data augmentation for defect detection of OLED panels. The data required to train an OLED defect detection model is difficult to obtain due to the high cost of OLED panels. Therefore, even if the data set is obtained, it is necessary to define and classify various defect types. This paper introduces an OLED panel defect data acquisition system that acquires a hypothetical data set and augments the data with an image generation model. In addition, the difficulty of generating pattern images in the diffusion model is identified and a possibility is proposed, and the limitations of data augmentation and defect detection data augmentation using the image generation model are improved.

Traumatic ventricular septal defect in a 4-year-old boy after blunt chest injury

  • Kim, Yun-Mi;Yoo, Byung-Won;Choi, Jae-Young;Sul, Jun-Hee;Park, Young-Hwan
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.2
    • /
    • pp.86-89
    • /
    • 2011
  • Traumatic ventricular septal defect (VSD) resulting from blunt chest injury is a very rare event. The mechanisms of traumatic VSD have been of little concern to dateuntil now, but two dominant theories have been described. In one, the rupture occurs due to acute compression of the heart; in the other, it is due to myocardial infarction of the septum. The clinical symptoms and timing of presentation are variable, so appropriate diagnosis can be difficult or delayed. Closure of traumatic VSD has been based on a combination of heart failure symptoms, hemodynamics, and defect size. Here, we present a case of a 4-year-old boy who presented with a traumatic VSD following a car accident. He showed normal cardiac structure at the time of injury, but after 8 days, his repeated echocardiography revealed a VSD. He was successfully treated by surgical closure of the VSD, and has been doing well up to the present. This report suggests that the clinician should pay great close attention to the patients injured by blunt chest trauma, keeping in mind the possibility of cardiac injury.

Analysis of Error Rate in the Variations of Shearing Amount in Measuring the Internal Defect using a Shearography (전단간섭계를 이용한 압력용기 내부 결함 측정시 전단량 변화에 따른 오차분석)

  • Hong, Kyung-Min;Kang, Young-June;Choi, In-Young;Ahn, Yong-Jin;Yoon, Suk-Bum
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.5
    • /
    • pp.726-732
    • /
    • 2012
  • Pipe and Pressure Vessels that is used in power plant and chemical industry have many Internal Defects that is corrosion caused by the flow of fluid. These Internal Defects that have possibility of explosion are very dangerous because it can not see from the outside. This days many companys using NDT method to find an Internal Defect. Most of the NDT methods have limitations that are constraint of shape and materials. But Sheargoraphy have many advantages compared conventional NDT method. It has very fast measuring speed, non-destructive and non contacting measurement. As well as it hasn't constraint of shape and materials. As a paper on the analysis of measurement of error, the important factors were the Shearing Amount and pressure, and discovered measurement of the Internal Defect of the object by using shearography. The optimal Shearing Amount and pressure was discovered and utilized.

Neurovascular Island Flap Transfer from a Dorsum of the Finger (수지 배측 피부를 이용한 신경혈관 도서형 피판술)

  • Kim, Poong-Taek;Kim, Ik-Dong;Kim, Jae-Hyung
    • Archives of Reconstructive Microsurgery
    • /
    • v.7 no.1
    • /
    • pp.10-14
    • /
    • 1998
  • When covering a skin defect of the finger with a local flap is difficult, a vascular island flap is often used. For a palmar skin defect, it is desirable to add a sensory supply to the flap. This report describes a neurovascular island flap that was used to repair a palmar skin defect, the donor skin coming from the dorsal region of the middle phalanx. This flap is elevated with a vascular pedicle of the palmar digital artery and its dorsal skin branch, including the dorsal digital veins, palmar digital nerve and its cutaneous branches. The advantage of this flap are that it can be transferred with ease and without any tension. No special manipulation is required under a microscope and operation can be performed under a simple nerve-block. There if little possibility that the flap itself undergoes ischemic change or congestion. The disadvantage of this flap are that a skin graft is required at the donor skin site and one palmar digital aretery is lost. We think that this neurovascular island flap is one of the useful methods for skin defects that are difficult to cover with a local flap.

  • PDF

The ISO/TS16949 the research regarding the application instance of the development technique for a APQP zero defect attainment (ISO/TS16949 APQP Zero Defect 달성을 위한 개발기법의 적용사례에 관한 연구)

  • Moon, Chan-Oh
    • Management & Information Systems Review
    • /
    • v.22
    • /
    • pp.211-229
    • /
    • 2007
  • The ISO/TS16949 APQP goal of defect prevention and decrease of spread waste, is the customer satisfaction which leads a continuous improvement and profit creation. The quality expense where the most is caused by but with increase of production initial quality problem occurrence is increasing to is actuality. Like this confirmation amendment. with the problem which is forecast in the place development at the initial stage which it does completeness it does not confront not to be able, production phase to be imminent, the problem accumulates and it talks the development shedding of which occurs. In opposition, prediction confrontation. is forecast in development early stage to and it is a structure which does not occur a problem to production early stage. Like this development is a possibility of accomplishing competitive company from production phase. Which attains an goal of, chance cause it leads a APQP activity (common cause) with special cause prevention & detection the connection characteristic of the focus technique against a interaction is important. And the customer requirement satisfaction and must convert a APQP goal of attainment at the key characteristics action step. (1) The Prevention - with Design FMEA application prevention of the present design management/detection, (2) the Detection (prevention/detection) - with Process FMEA application prevention of the present process control/detection, (3) Special Cause - statistical process control (SPC) 4M cause spread removal, (4) Common Cause - statistical process control (SPC) the nothing zero defect which leads the continuous improvement back of spread with application it will be able to attain with application.

  • PDF

Surface Defect Properties of Prime, Test-Grade Silicon Wafers (프라임, 테스트 등급 실리콘 웨이퍼의 표면 결함 특성)

  • Oh, Seung-Hwan;Yim, Hyeonmin;Lee, Donghee;Seo, Dong Hyeok;Kim, Won Jin;Kim, Ryun Na;Kim, Woo-Byoung
    • Korean Journal of Materials Research
    • /
    • v.32 no.9
    • /
    • pp.396-402
    • /
    • 2022
  • In this study, surface roughness and interfacial defect characteristics were analyzed after forming a high-k oxide film on the surface of a prime wafer and a test wafer, to study the possibility of improving the quality of the test wafer. As a result of checking the roughness, the deviation in the test after raising the oxide film was 0.1 nm, which was twice as large as that of the Prime. As a result of current-voltage analysis, Prime after PMA was 1.07 × 10 A/cm2 and Test was 5.61 × 10 A/cm2, which was about 5 times lower than Prime. As a result of analyzing the defects inside the oxide film using the capacitance-voltage characteristic, before PMA Prime showed a higher electrical defect of 0.85 × 1012 cm-2 in slow state density and 0.41 × 1013 cm-2 in fixed oxide charge. However, after PMA, it was confirmed that Prime had a lower defect of 4.79 × 1011 cm-2 in slow state density and 1.33 × 1012 cm-2 in fixed oxide charge. The above results confirm the difference in surface roughness and defects between the Test and Prime wafer.