• Title/Summary/Keyword: Defect Map

Search Result 73, Processing Time 0.04 seconds

Study on the Relationship between Concentration of JGB and Current Density in TSV Copper filling (TSV 구리 필링 공정에서 JGB의 농도와 전류밀도의 상관 관계에 관한 연구)

  • Jang, Se-Hyun;Choi, Kwang-Seong;Lee, Jae-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.4
    • /
    • pp.99-104
    • /
    • 2015
  • The requirement for success of via filling is its ability to fill via holes completely without producing voids or seams. Defect free via filling was obtained by optimizing plating conditions such as current mode, current density and additives. However, byproducts stemming from the breakdown of these organic additives reduce the lifetime of the devices and plating solutions. In this study, the relationship between JGB and current density on the copper via filling was investigated without the addition of other additives to minimize the contamination of copper via. AR 4 with $15{\mu}m$ diameter via were used for this study. The pulse current was used for the electroplating of copper and the current densities were varied from 10 to $20mA/cm^2$ and the concentrations of JGB were varied from 0 to 25 ppm. The map for the JGB concentration and current density was developed. And the optimum conditions for the AR 4 via filling with $15{\mu}m$ diameter were obtained.

Suggested Shiny-Sigma method suitable for the shop floor (현장에 적합한 샤이니-시그마 기법 제안)

  • Kim, Kang Hee;Ree, Sang Bok
    • Journal of Korean Society for Quality Management
    • /
    • v.45 no.2
    • /
    • pp.227-246
    • /
    • 2017
  • Purpose: This study proposes a Shiny-Sigma Methods that combines the advantages of Six Sigma method and Shainin method in order to solve field defect. Each technique has advantages and disadvantages. Methods: This study proposed Shiny-Sigma by combining Six Sigma has the logical advantage of the problem solving road map and Shiny has the merits of finding the root problem from the defective phenomenon. The Six Sigma method has the disadvantage that it is difficult to solve if the number of data is small, but the Shiny method has the advantage of finding the root cause with a small number of data. Results: As a result of applying Shiny-Sigma method to the field, it has advantages of solving the problem easily and quickly than the existing Six Sigma method. It does not require a lot of statistical knowledge, which helps field workers to use it. Based on these successes L Co. company has obtained the effect of improving the production quality by applying the Shiny-Sigma method. Conclusion: The Shiny-Sigma method proved to be suitable for the production site as a result of field application. It is suitable for field workers with low statistical knowledge and is suitable for field where data is difficult to obtain. This method is not a method to solve all the problems because there are problems that can be solved according to the field problems. We hope that this method will spread to many industrial sites and this method will have a great effect on the improvement of field production quality.

A Study on Improvement about abnormal display of Multi Function Display for KUH (한국형 기동헬기 다기능시현기의 이상시현 개선에 관한 연구)

  • Kim, Young Mok;Chang, Joong Jin;Jun, Byung Kyu;Kim, Chang Young;Kim, Tae Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.4
    • /
    • pp.344-350
    • /
    • 2014
  • Multi Function Display(MFD) of Korean Utility Helicopter(KUH) is the component of mission management/display control system and displays image information(navigation, flight, survivability, digital map, maintenance) acquired from Mission Computer(MC) while the aircraft is operated. It is an essential equipment for pilots to perform flight mission and it has functions of display scene control, data display, built in test(BIT) and brightness control. In this paper, it is analyzed the cause of abnormal display(flickering) on MFD and summarized the design changes to solve the defect. It is also described system safety analysis and suggested verification results of flight/ground test.

A Method for Information Management of Defects in Bridge Superstructure Using BIM-COBie (BIM-COBie를 활용한 교량 상부구조의 손상정보 관리 방법)

  • Lee, Sangho;Lee, Jung-Bin;Tak, Ho-Kyun;Lee, Sang-Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.165-173
    • /
    • 2023
  • The data management and the evaluation of defects in the bridge are generally conducted based on inspection and diagnosis data, including the exterior damage map and defect quantity table prepared by periodic inspection. Since most of these data are written in 2D-based documents and are difficult to digitize in a standardized manner, it is challenging to utilize them beyond the defined functionality. This study proposed methods to efficiently build a BIM (Building Information Modeling)-based bridge damage model from raw data of inspection report and to manage and utilize the damage information linking to bridge model through the spread sheet data generated by COBie (Construction Operations Building Information Exchange). In addition, a method to conduct the condition assessment of defects in bridge was proposed based on an automatic evaluation process using digitized bridge member and damage information. The proposed methods were tested using superstructure of PSC-I girder concrete bridge, and the efficiency and effectiveness of the methods were verified.

Comparison of Emergency Tc-99m Sestamibi Myocardial Perfusion SPECT and ECG in the Diagnosis of Acute Myocardial Infarction (급성심근경색증 환자에서 응급으로 시행한 Tc-99m Sestamibi 심근관류 SPECT와 심전도의 비교)

  • Cho, Ihn-Ho;Lee, Hyoung-Woo;Park, Jong-Sun;Won, Kyu-Chang;Do, Jun-Young;Sin, Dong-Gu;Yoon, Kyung-Woo;Kim, Young-Jo;Shim, Bong-Sup;Lee, Hyun-Woo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.104-111
    • /
    • 1996
  • We did Tc-99m sestamibi myocardial perfusion SPECT in 36 patients with acute myocardial infarction when they arrived at the emergency room. And we compared myocardial perfusion images with ECG findings. Then we obtained the follows. The myocardial infarction by the obstruction of left coronary descending artery and right coronary artery showed a good concordance in the diagnosis and infarction site between myocardial perfusion images and ECG findings. The 7 patients with myocardial infarction by a left circumflex coronary artery showed a perfusion defect in the lateral wall in myocardial perfusion SPECT images. But 4 patients of them showed ST segment elevation, 2 patients showed ST depression and 1 patient showed normal ECG findings. The diagnostic sensitivity of Tc-99m sestamibi myocardial perfusion SPECT was 100% by a qualified analysis. The perfusion defect site in the myocardial perfusion SPECT were corresponded with the infarct related coronary artery in 31 patients which was diagnosed by coronary angiograpy. The size of perfusion defect in the po1ar map was $31{\pm}18%(M{\pm}SD)$, in the myocardial infarction with left anterior descending coronary arery obstruction, $31{\pm}13% (M{\pm}SD)$ in the myocardial infarction with right coronary artery obstruction and $25{\pm}5.9%(M{\pm}SD)$ in the myocardial infarction with left circumflex coronary artery obstruction. We concluded that emergency myocardial perfusion SPECT images are useful in the diagnose of myocardial infarction and it's very useful when we are difficult to diagnose with ECG like as lateral wall infarction or left bundle branch block.

  • PDF

Immersive Visualization of Casting Solidification by Mapping Geometric Model to Reconstructed Model of Numerical Simulation Result (주물 응고 수치해석 복원모델의 설계모델 매핑을 통한 몰입형 가시화)

  • Park, Ji-Young;Suh, Ji-Hyun;Kim, Sung-Hee;Rhee, Seon-Min;Kim, Myoung-Hee
    • The KIPS Transactions:PartA
    • /
    • v.15A no.3
    • /
    • pp.141-149
    • /
    • 2008
  • In this research we present a novel method which combines and visualizes the design model and the FDM-based simulation result of solidification. Moreover we employ VR displays and visualize stereoscopic images to provide an effective analysis environment. First we reconstruct the solidification simulation result to a rectangular mesh model using a conventional simulation software. Then each point color of the reconstructed model represents a temperature value of its position. Next we map the two models by finding the nearest point of the reconstructed model for each point of the design model and then assign the point color of the design model as that of the reconstructed model. Before this mapping we apply mesh subdivision because the design model is composed of minimum number of points and that makes the point distribution of the design model not uniform compared with the reconstructed model. In this process the original shape is preserved in the manner that points are added to the mesh edge which length is longer than a predefined threshold value. The implemented system visualizes the solidification simulation data on the design model, which allows the user to understand the object geometry precisely. The immersive and realistic working environment constructed with use of VR display can support the user to discover the defect occurrence faster and more effectively.

Cloning of a Gene Involved in Biosynthesis of ${\beta}-1,3-glucan$ in Saccharomyces cerevisiae (베타-1,3-글루칸 생합성에 관여하는 Saccharomyces cerevisiae 유전자의 클로닝)

  • Jin, Eun-Hee;Lee, Dong-Won;Kim, Jin-Mi;Park, Hee-Moon
    • The Korean Journal of Mycology
    • /
    • v.23 no.2 s.73
    • /
    • pp.129-138
    • /
    • 1995
  • DNA fragment being able to restore in vitro activity of ${\beta}-1,3-glucan$ synthase was cloned by transformation of the Saccharomyces cerevisiae LP353 mutant strain with genomic library constructed in the YCp50. For the selection of transformants which showed no detectable phenotype linked to recovery of the defect in ${\beta}-1,3-glucan$ synthase activity, the colony autoradiography was succesfully applied. The restriction map of the cloned DNA fragment, which is 8.5-kb in length, was constructed. Both the YEplac195 and the YCp50 carrying the 8.5-kb fragment increased ${\beta}-1,3-glucan$ synthase activity of LP353 by two fold. Neither the YEplac195 nor the YCp50 carrying the 8.5-kb DNA fragment, however, complemented the temperature-dependent osmotic sensitivity which is another distinctive phenotype of LP353. Subcloning experiments indicated that a functional region was located in 4.8-kb BglII-KpnI fragment. The 4.8-kb fragment was also able to increase the level of ${\beta}-1,3-glucan$ content in cell wall as well as the resistance of cells to cell wall lytic enzyme, ${\beta}-1,3-glucanase$. The growth rate of the LP353 with 4.8-kb fragment was almost same as that of wild type strain in liquid medium with 1.2 M sorbitol at nonpermissive temperature. Taken these results together, the 4.8-kb fragment seemed to contain the BGS2 gene for ${\beta}-1,3-glucan$ synthase activity in yeast S. cerevisiae.

  • PDF

Out-of-plane Deformation Measurement of Spherical Glasses Lens Using ESPI (ESPI를 이용한 구면 안경렌즈의 면외 변형 측정)

  • Yang, Seung-Pill;Kim, Kyoung-Suk;Jang, Ho-Sub;Kim, Hyun-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.77-81
    • /
    • 2007
  • The spherical lens is typically classified by the refractive power into two groups such as (+) diopter lens and (-) diopter lens. The deformation occurred by the external force that is applied to a lens is caused by the increase or the decrease in the diopter of a lens. In this paper, the deformation of the lens was quantitatively measured by using ESPI (Electronic Speckle Pattern Interferometry) which have been used in the optical measurement field for past few years. ESPI has an advantage that the deformation of an object can be measured precisely by using coherence of the light. The experiment was carried out to the totally 16 types of plastic lens. It was confirmed that the deformation was decreased by increasing the diopter of the lens when same displacement was applied to the lens in case of (+) diopter lens and was increased by decreasing the diopter of the lens in case of (-) diopter lens. Also, it was found that the deformation of (+) diopter lens is less than that of (-) diopter lens. Therefore, with these results, it is expected that the possibility of the quantitative measurement for variation of the optical defect caused by the deformation of a lens when the deformation is occurred to the various types of the lens can be presented and that the application in the lens industrial field can be performed.

  • PDF

A Quantitative Method for the Assessment of Myocardial Function using the Polar Analysis of Tc-99m-MIBI Myocardial SPECT (Tc-99m-MIBI 심근 SPECT 극성지도 분석에 의한 심근 기능의 정량적 평가)

  • Kwark, Cheol-Eun;Lee, Dong-Soo;Yeo, Jung-Suk;Lee, Kyung-Han;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.2
    • /
    • pp.172-176
    • /
    • 1994
  • As the Tc-99m-MIBI myocardial SPECT demonstrated wide application in the diagnosis of myocardial function, the quantitative and severity-dependent information is currently re quired. In this study, we proposed a computerized method for scoring the fixed defects in terms of extent-weighted severity and for identifying the reversibility in ischemic regions. At the first stage of this method, the transverse slices were reconstructed with 0.4 Nyquist freq. and order 5 Butterworth filter. From the oblique/sagittal slices, maximal count per pixel circumferential profiles were extracted for each sector, and then stress/redist. polar maps were normalized and plotted. For reversibility, the stress polar map was subtracted from the de-layed image and positive-valued pixels were categorized into three grades. The extent-weight-ed severity scores were calculated using the assigned grades and their number of pixels. This procedure was done automatically and the reversibility and severity scores were produced for each of the coronary territories (LAD, RCA, LCX) or any combination of these. Clinical ap-plication has shown that the changes In reversibility scores after PTCA were correlated linearly with the pre PTCA scores(r>0.8) in postinfarct cases as well as in angina, and severity scores of persistent defects in stress/rest SPECT study matched to the regional ejection fraction and visual analysis of regional wall motion of gated blood pool scan(r>0.6). We conclude that the computerized severity scoring method for the analysis of myocardial SPECT could be useful in the assessment of the myocardial ischemia and fixed defect.

  • PDF

The Study of Aerial Triangulation Using GPS (GPS를 이용한 사진기준점 측랑에 관한 연구)

  • 이재원;문두열;김정희;김진수
    • Spatial Information Research
    • /
    • v.12 no.2
    • /
    • pp.181-191
    • /
    • 2004
  • Nowadays, GPS-photogrammetry can be applied to the basemap production, a land register and NGIS. And from now on, as the increase of GPS receiver rate, the study on the interpolation methods considering the exact movement of an aircraft at photoflight and the study on the supplement of GPS defect by INS are required continuously. GPS-Photogrammetry, which are based on the direct measurement of the projection centers and attitude at the moment of camera exposure time through loading the GPS receiver in aircraft. This photogrammetric methods can of for us to acquire the exterior orientation parameters with only minimum ground control points, even the ground control process could be completely skipped. Consequently, we can drastically reduce the time and cost far the mapping process. In this thesis, two test flights were conducted in area to evaluate the performance of accuracy and efficiency through the analysis of results between the two photogrammetric methods, that is, traditional photograrammetry, GPS-Photogrammetry. Test results shows that a large variety of advantages of GPS-Photogrammetry against traditional photogrammetry is to be verified. Especially, the number of ground control points for the exterior orientation could be saved more than 70~80%, and the cost far map production 30~50%, respectively. In addition, it was convinced that the large reduction of control points has not any effect on the block accuracy.

  • PDF