• Title/Summary/Keyword: Defect Imaging

Search Result 265, Processing Time 0.027 seconds

Leiomyosarcoma of Urinary Bladder in a Yorkshire Terrier Dog

  • Mok, Jinsu;Park, Junghyun;An, Soyon;Kim, Ahreum;Han, Changhee;Hwang, Taesung;Lee, Hee Chun
    • Journal of Veterinary Clinics
    • /
    • v.37 no.2
    • /
    • pp.91-95
    • /
    • 2020
  • A 13-year-old, intact male, Yorkshire terrier dog with oliguria and hematuria was presented to the Small Animal Clinic at the Gyeongsang National University animal medical center. There were no remarkable findings on serum chemistry values and complete blood counts. Abdominal radiographs revealed mild elevation of the descending colon at the pelvic level. On the excretory urographic images, a large filling defect was identified in urinary bladder with narrow urinary bladder wall contact and there were no remarkable findings in kidneys and ureters. The abdominal ultrasonography revealed that an irregularly marginated, heterogeneous mass in urinary bladder, central cavitary lesion and mild vascular flow were also observed. Computed tomography showed a heterogeneously attenuated mass within urinary bladder. The mass was surgically excised, and leiomyosarcoma was confirmed by histopathological examination. The patient was followed up for two months and there were no complications. This case is of interest because of the unusual findings of leiomyosarcoma of urinary bladder in a small breed dog.

Quantitative nondestructive evaluation of thin plate structures using the complete frequency information from impact testing

  • Lee, Sang-Youl;Rus, Guillermo;Park, Tae-Hyo
    • Structural Engineering and Mechanics
    • /
    • v.28 no.5
    • /
    • pp.525-548
    • /
    • 2008
  • This article deals the theory for solving an inverse problem of plate structures using the frequency-domain information instead of classical time-domain delays or free vibration eigenmodes or eigenvalues. A reduced set of output parameters characterizing the defect is used as a regularization technique to drastically overcome noise problems that appear in imaging techniques. A deconvolution scheme from an undamaged specimen overrides uncertainties about the input signal and other coherent noises. This approach provides the advantage that it is not necessary to visually identify the portion of the signal that contains the information about the defect. The theoretical model for Quantitative nondestructive evaluation, the relationship between the real and ideal models, the finite element method (FEM) for the forward problem, and inverse procedure for detecting the defects are developed. The theoretical formulation is experimentally verified using dynamic responses of a steel plate under impact loading at several points. The signal synthesized by FEM, the residual, and its components are analyzed for different choices of time window. The noise effects are taken into account in the inversion strategy by designing a filter for the cost functional to be minimized. The technique is focused toward a exible and rapid inspection of large areas, by recovering the position of the defect by means of a single accelerometer, overriding experimental calibration, and using a reduced number of impact events.

Pentalogy of Fallot with Subaortic Stenosis in a Mixed Dog (잡종견의 대동맥하 협착증을 동반한 팔로오증)

  • Lee, Seung-Keun;Jang, Jin-Ung;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.26 no.2
    • /
    • pp.155-159
    • /
    • 2009
  • A 2-year-old female mixed dog(weighing 4.3 kg) was referred to the Veterinary Teaching Hospital, Kangwon National University, with primary complaints of exercise intolerance, nocturnal coughing and heart murmur. Diagnostic studies revealed bi-lateral holosystolic murmurs on phonocardiogram, over-riding aorta, pulmonic stenosis, ventricular septal defect, atrial septal defect, biventricular hypertrophy, and subaortic stenosis in diagnostic imaging studies. Based on the diagnostic findings, pentalogy of Fallot(POF) with subaortic stenosis(SAS) was tentatively diagnosed. This is the first case report of POF complicated with SAS in a dog in Korea.

Rapid Defect Inspection of Display Device with Optical Spatial Filtering

  • Yoon, Dong-Seon;Kim, Seung-Woo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.1 no.1
    • /
    • pp.56-61
    • /
    • 2000
  • We present a fast inspection method of machine vision for in-line quality assurance of liquid crystal displays(LCD) and plasma display panels(PDP). The method incorporates an optical spatial filter in the Fourier plane of the imaging optics to block the normal periodic pattern, extracting only defects real time without relying on intensive software image process. Special emphasis is on designing a collimated white light source to provide high degree of spatial coherence for effective real time Fourier transform. At the same time, a low level of temporal coherence is attained to improve defect detection capabilities by avoiding undesirable coherent noises. Experimental results show that the proposed inspection method offers a detection accuracy of 15% tolerance, which is sufficient for industrial applications.

  • PDF

Intraorbital Encephalocele Presenting with Exophthalmos and Orbital Dystopia : CT and MRI Findings

  • Asil, Kiyasettin;Gunduz, Yasemin;Yaldiz, Can;Aksoy, Yakup Ersel
    • Journal of Korean Neurosurgical Society
    • /
    • v.57 no.1
    • /
    • pp.58-60
    • /
    • 2015
  • A 15-year-old female patient with progressive pulsatile exophthalmos caused by intraorbital encephalocele was evaluated with computed tomography (CT) and magnetic resonance imaging (MRI) in our clinic. She had no history of trauma or reconstructive surgery. When she was a little girl, she had undergone surgery for congenital glaucoma on the right eye. On the three-dimensional image of CT, a hypoplasic bone defect was observed in the greater wing of the right sphenoid bone. MRI and CT scan showed herniation through this defect of the arachnoid membrane and protruded cerebral tissue into the right orbita. Intraorbital encephalocele is an important entity that can cause pulsatile exophthalmos and blindness.

Development of Automatic Visual Inspection for the Defect of Compact Camera Module

  • Ko, Kuk-Won;Lee, Yu-Jin;Choi, Byung-Wook;Kim, Johng-Hyung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2414-2417
    • /
    • 2005
  • Compact Camera Module(CCM) is widely used in PDA, Celluar phone and PC web camera. With the greatly increasing use for mobile applications, there has been a considerable demands for high speed production of CCM. The major burden of production of CCM is assembly of lens module onto CCD or CMOS packaged circuit board. After module is assembled, the CCM is inspected. In this paper, we developed the image capture board for CCM and the imaging processing algorithm to inspect the defects in captured image of assembled CCMs. The performances of the developed inspection system and its algorithm are tested on samples of 10000 CCMs. Experimental results reveal that the proposed system can focus the lens of CCM within 5s and we can recognize various types of defect of CCM modules with good accuracy and high speed.

  • PDF

Left Ventricular Pseudo-pseudoaneurysm with Hemopericardium

  • Kim, Hye-Seon;Kim, Kyung-Hwan;Hwang, Ho-Young
    • Journal of Chest Surgery
    • /
    • v.44 no.3
    • /
    • pp.247-249
    • /
    • 2011
  • We report a case of pseudo-pseudoaneurysm, which is a very rare complication of myocardial infarction. A 69-year-old man was admitted to our clinic with chest tightness and dyspnea. He had undergone aortic valve replacement with a pericardial bioprosthetic valve, ring mitral annuloplasty, and reconstruction of an aortic annular defect due to infective endocarditis with bovine pericardium 4 years prior. Echocardiography and computed tomography showed pericardial effusion and a 16-mm cavity at the anterolateral wall of the left ventricle. Magnetic resonance imaging suggested either pseudo-pseudoaneurysm or myocardial abscess. We successfully repaired the myocardial defect using a patch made from a vascular graft with pledgeted horizontal mattress sutures under cardiopulmonary bypass.

Simulation of Ultrasonic Beam Focusing on a Defect in Anisotropic, Inhomogeneous Media

  • Jeong, Hyun-Jo;Cho, Sung-Jong;Erdenetuya, Sharaa;Jung, Duck-Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.6
    • /
    • pp.635-641
    • /
    • 2011
  • In ultrasonic testing of dissimilar metal welds, application of phased array technique in terms of incident beam focusing is not easy because of complicated material structures formed during the multi-pass welding process. Time reversal(TR) techniques can overcome some limitations of phased array since they are self-focusing that does not depend on the geometrical and physical properties of testing components. In this paper, we test the possibility of TR focusing on a defect within anisotropic, heterogeneous austenitic welds. A commercial simulation software is employed for TR focusing and imaging of a side-drilled hole. The performance of time reversed adaptive focal law is compared with those of calculated focal laws for both anisotropic and isotropic welds.

Giant Arachnoid Granulation Misdiagnosed as Transverse Sinus Thrombosis

  • Choi, Hyuk-Jin;Cho, Chang-Won;Kim, Yoon-Suk;Cha, Jae-Hun
    • Journal of Korean Neurosurgical Society
    • /
    • v.43 no.1
    • /
    • pp.48-50
    • /
    • 2008
  • We experienced a case of giant arachnoid granulation misdiagnosed as dural sinus thrombosis. A 66-year-old woman presented with a one month history of progressive occipital headache. Computed tomography angiography and cerebral angiography showed a round filling defect at the transverse sinus which was speculated as a transverse sinus thrombosis. Anticoagulation therapy was performed to prevent worsening of thrombosis for 2 weeks and then a Gadolinium-enhanced magnetic resonance imaging scan was performed. The filling defect lesion at the transverse sinus revealed a non-enhancing granule with central linear enhancement, which was compatible with giant arachnoid granulation. We checked the intrasinus pressure difference across the lesion the through the dural sinus in order to exclude the lesion as the cause of headache. Normal venous pressure with no significant differential pressure across the lesion was noted. Headache was treated with medical therapy.

Guided-Wave Tomographic Imaging of Plate Defects by Laser-Based Ultrasonic Techniques

  • Park, Junpil;Lim, Juyoung;Cho, Younho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.6
    • /
    • pp.435-440
    • /
    • 2014
  • Contact-guided-wave tests are impractical for investigating specimens with limited accessibility and rough surfaces or complex geometric features. A non-contact setup with a laser-ultrasonic transmitter and receiver is quite attractive for guided-wave inspection. In the present work, we developed a non-contact guided-wave tomography technique using the laser-ultrasonic technique in a plate. A method for Lamb-wave generation and detection in an aluminum plate with a pulsed laser-ultrasonic transmitter and Michelson-interferometer receiver was developed. The defect shape and area in the images obtained using laser scanning, showed good agreement with the actual defect. The proposed approach can be used as a non-contact online inspection and monitoring technique.