• 제목/요약/키워드: Defect Imaging

검색결과 267건 처리시간 0.03초

Transport property of a Se:As films for digital x ray imaging

  • 김재형;김재형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 학술대회 및 기술세미나 논문집 디스플레이 광소자
    • /
    • pp.85-88
    • /
    • 2006
  • The transport properties of amorphous selenium typical of the material used in direct conversion x-ray imaging devices are reported. The effects of As addition on the carrier mobility and recombination lifetime in amorphous selenium (a-Se) films have been studied using the moving photocarrier grating (MPG) technique. We have found an increase in hole drift mobility and recombination lifetime, especially when 0.3% As is added into a-Se film, whereas electron mobility decreases with As addition due to the defect density. The transport properties for As doped a-Se films obtained by using MPG technique have been compared with the drift mobilities of holes and electrons obtained by time of flight (TOF) measurement.

  • PDF

VISUALIZATION OF INTERNAL DEFECTS IN PLATE-TYPE NUCLEAR FUEL BY USING NONCONTACT OPTICAL INTERFEROMETRY

  • Park, Seung-Kyu;Park, Nak-Gyu;Baik, Sung-Hoon;Kang, Young-June
    • Nuclear Engineering and Technology
    • /
    • 제45권3호
    • /
    • pp.361-366
    • /
    • 2013
  • An imaging technique to visualize the internal defects in a plate-type nuclear fuel specimen was developed by using an active optical interferometer for a nondestructive quality inspection. A periodic thermal wave having a sinusoidal intensity pattern induced a periodical strain variation for the specimen. The varying strain image was acquired using an optical laser interferometer. The strain distribution over the internal defects will be distorted in an acquired strain image because a part of the thermal wave will be reflected from these defects during propagation. In this paper, internal defects were efficiently visualized by sequentially accumulating the extracted defect components. The experimental results confirmed that the developed visualization system can be a valuable tool to detect the internal defects in plate-type nuclear fuel.

6mm$^{t}$ 조선용 Primer코팅강판의 $CO_2$레이저 용접성 (III) - X-선 투과영상시스템에 의한 결함형성거동의 리얼타임관찰 - (The Weldability of 6mm$^{t}$ Primer-coated Steel for Shipbuilding Using $CO_2$ Laser (III) - Real-time X-ray Imaging Observation of Defect Formation of Laser Welding -)

  • 김종도;박현준;이종봉;김영식
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2004년도 춘계 학술발표대회 개요집
    • /
    • pp.103-105
    • /
    • 2004
  • 키홀 용접현상에 관한 연구는, 키홀 현상이 용융금속내부에서 아주 빠른 속도로 과도적으로 이루어지기 때문에 그 계측과 해석이 곤란하여 수 많은 가정이나 가설 하에서 용입형상과 키홀의 거동에 관한 해석이 국한된 영역에서 이루어지고 있는 것이 현실이다. (중략)

  • PDF

연골결손에 대한 자가 골연골 이식 수술 후 이차 관절경 소견 (Second look Arthroscopic finding after Osteochondral Autogenous Graft Transfer for the Chondral defect of the Knee)

  • 최남홍;곽호윤;송백용;배상욱;이인묵;김우진
    • 대한관절경학회지
    • /
    • 제5권2호
    • /
    • pp.99-103
    • /
    • 2001
  • 목적 : 이번 전향적 연구의 목적은 슬관절의 연골 결손 환자의 치료로서 자가 골연골 이식술을 시행한 후 이차 관절경을 시행하여 관찰하는 것이다. 재료 및 방법 : 슬관절의 연골 결손의 치료로 자가 골연골 이식술이 시행된 40명의 환자 중 14면에서 이차 관절경이 시행되었다. 환자들의 연령은 $17\~59$세로, 평균 연령은 34세였다. 수술 전 14명 중 11명에게서 자기 공명영상을 시행하여 9면에서 연골 결손이 관찰되었으나 관절경술상 전례에서 연골결손을 확인하였다. 연골 결손의 부위는 대퇴골 내과가 7명, 활차 부위가 4명, 대퇴골 외과가 3명이었다. 연골 결손의 크기는 평균 $13\times10mm$, 최소 $5\times10mm$, 최대 $22\times20mm$이었다. 사용된 골연골의 갯수는 1개를 사용한 경우 8명, 2개가 3명, 3개가 2명, 5개가 1명이었다. 결과 : 수술 후 추적 관찰은 평균 21개월이었다. 대부분의 경우 수술 후 6개월에 이차 관절경을 시행하였다. 시행한 환자의 $86\%$에서 이식된 연골의 경도가 주변의 연골과 같았으며, $93\%$의 환자에서 주변 연골과 잘 융화된 것을 관찰할 수 있었다. 결론 : 자가 골연골 이식술을 자가 골연골 이식술은 슬관절의 연골결손의 치료의 한 방법으로 사용될 수 있을 것으로 생각된다.

  • PDF

집속이온빔장치와 주사전자현미경을 이용한 박막 트랜지스터 구조불량의 3차원 해석 (Three Dimensional Reconstruction of Structural Defect of Thin Film Transistor Device by using Dual-Beam Focused Ion Beam and Scanning Electron Microscopy)

  • 김지수;이석열;이임수;김재열
    • Applied Microscopy
    • /
    • 제39권4호
    • /
    • pp.349-354
    • /
    • 2009
  • TFT-LCD의 구조불량이 발생한 박막 트랜지스터에 대해서 집속이온빔 가공장치(Dual-beam FIB/SEM)를 이용하여 연속절편법(Serial sectioning)과 일련의 연속적인 2차원 주사전자현미경 이미지를 얻었고, IMOD 소프트웨어를 통해서 3차원 구조구현(3D reconstruction) 연구를 하였다. 3차원 구조구현 결과, Gate막과 Data막이 접합되어 있는 불량이 관찰되었다. 두 막이 접합되어서 ON/OFF 역할을 하는 Gate의 기능이 상실되었고, Data신호는 Drain을 통해서 투명전극에 전류를 공급하여 계속 빛나는 선 불량(line defect)이 발생한 것으로 판단된다. 이 논문의 결과인 집속이온빔 가공장치(Dual-Beam FIB/SEM)를 이용한 3차원 구조구현 연구와 연속절편법, 주사전자현미경 이미지작업, 이미지 프로세싱에 대한 결과는 향후 연구의 기초자료로 활용될 수 있을 것으로 판단된다.

표면파 기반의 풍력발전기 블레이드 표면상태 실시간 모니터링에 관한 연구 (Defect Monitoring of a Wind Turbine Blade Surface by using Surface Wave Damping)

  • 김경환;양영진;김현범;양형찬;임종환;최경현
    • 청정기술
    • /
    • 제23권1호
    • /
    • pp.90-94
    • /
    • 2017
  • 현재 풍력발전은 우리나라에서 가장 주목 받고 있는 신재생에너지 분야로 많은 연구가 진행 중이다. 풍력발전을 구성하는 요소 중 핵심 요소인 블레이드에 손상이 발생할 경우에 발전 효율에 직접적인 영향을 미치므로 효율적인 유지보수를 위해 초기에 결함을 측정하는 기술이 매우 중요한 상태이다. 그러나 기존의 초음파 비파괴 검사 및 열화상 비파괴 검사는 소요시간이 길고 실시간 모니터링이 어려우므로 초기 결함 측정이 불가능하다. 기존의 문제를 보완하고자 본 논문에서는 표면파를 이용한 블레이드 표면상태 실시간 모니터링에 관한 연구를 수행하였다. 압전센서 기반의 시스템을 구성하여 블레이드 표면샘플에 대해 공정 변수 별 기초 성능 실험을 하였고, 소형 블레이드에 대해 공정변수 별 실험을 통해 블레이드의 크랙, 벗겨짐, 장애물 등을 실시간으로 모니터링이 가능한지 연구 하였다.

Quantitative measurement of peri-implant bone defects using optical coherence tomography

  • Kim, Sulhee;Kang, Se-Ryong;Park, Hee-Jung;Kim, Bome;Kim, Tae-Il;Yi, Won-Jin
    • Journal of Periodontal and Implant Science
    • /
    • 제48권2호
    • /
    • pp.84-91
    • /
    • 2018
  • Purpose: The purpose of this study was to visualize and identify peri-implant bone defects in optical coherence tomography (OCT) images and to obtain quantitative measurements of the defect depth. Methods: Dehiscence defects were intentionally formed in porcine mandibles and implants were simultaneously placed without flap elevation. Only the threads of the fixture could be seen at the bone defect site in the OCT images, so the depth of the peri-implant bone defect could be measured through the length of the visible threads. To analyze the reliability of the OCT measurements, the flaps were elevated and the depth of the dehiscence defects was measured with a digital caliper. Results: The average defect depth measured by a digital caliper was $4.88{\pm}1.28mm$, and the corresponding OCT measurement was $5.11{\pm}1.33mm$. Very thin bone areas that were sufficiently transparent in the coronal portion were penetrated by the optical beam in OCT imaging and regarded as bone loss. The intraclass correlation coefficient between the 2 methods was high, with a 95% confidence interval (CI) close to 1. In the Bland-Altman analysis, most measured values were within the threshold of the 95% CI, suggesting close agreement of the OCT measurements with the caliper measurements. Conclusions: OCT images can be used to visualize the peri-implant bone level and to identify bone defects. The potential of quantitative non-invasive measurements of the amount of bone loss was also confirmed.

내측 반월상 연골판 후각 기시부 파열 봉합 후 추시 자기공명영상 검사의 유용성 (Magnetic resonance imaging Usefulness after Medial Meniscus Posterior Root Tear Repair)

  • 전재균;김준범;이봉주
    • 대한관절경학회지
    • /
    • 제17권1호
    • /
    • pp.6-10
    • /
    • 2013
  • 목적: 슬관절 내측 연골판 후각 기시부 파열에 대하여 관절경적 봉합 수술을 시행한 후 유합 유무를 평가하기 위한 magnetic resonance imaging (MRI)의 유용성에 대하여 보고 하고자 한다. 대상 및 방법: 2007년 11월부터 2011년 6월까지 내측 반월상 연골판 후각 기시부 파열을 봉합한 환자 중 술후 MRI와 관절경검사를 모두 시행하였던 17명을 대상으로 하였다. 관절경검사와 MRI 검사를 시행하여 비교하였다. 결과: 술전 Lysholm knee score는 평균 56.4에서 평균 79.0으로 visual analogue scale (VAS) score는 8점에서 3점으로 호전되었다. 2차적 관절경 검사상 17예 모두 섬유화 재생 후 안정화된 소견이 확인되었다. 그러나 MRI 검사에서 내측 반월상 연골판 후각 기시부 파열을 시사하는 수직 직선 결함(cleft sign)은 술전후 모두 관찰되었고, 음영 손실(ghost sign)은 술전 10예에서 술후 9예, 방사선 직선 결함(radial linear defect) 소견은 술전 17예에서 술후는 15예에서 확인되었다. 결론: 내측 반월상 연골판 후각 기시부 파열의 관절경적 봉합술을 시행한 환자를 대상으로 비해부학적 위치에 봉합한 경우 술후 추시 MRI 검사는 유합 여부 판단에 유용하지 않았다. 유합 여부를 정확하게 평가하기 위해서는 관절경적 검사가 필요한 것으로 판단된다.

  • PDF

심근관류 SPECT와 64채널 전산화 단층혈관 촬영 사진 융합으로 증명된 radius intermedius 협착에 의한 심근관류 저하 (Radius Intermedius Stenosis Induced Myocardial Perfusion Defect: Provened by the Fusion Images of Myocardial Perfusion SPECT and 64 Channel CTA)

  • 공은정;조인호;천경아;원규장;이형우;박종선
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권1호
    • /
    • pp.77-78
    • /
    • 2008
  • A 71-year-old woman was assigned to our department for Tc-99m myocardial perfusion SPECT(MPS) and coronary CT angiography. She admitted for substernal pain, via the ER, 2 days ago. The heart was scanned after intravenous injection of 925 MBq of $^{99m}Tc$-sestamibi adenosine-induced stress SPECT using dual head gamma camera (Hawkeye, GE healthcare. USA). The MPS shows decreased tracer uptake in the apical & mid area of anterior & lateral wall and mid & basal inferior wall. Coronary CT angiograph was obtained using Discovery VCT (GE healthcare). 3D angiography portrayed significant stenosis of ramus intermedius(RI) and posterolateral branch of right coronary artery(PLB) with fibrocalcified plaque. Two images were fused using Cardiac IQ fusion softwear package (Advantage workstation 4.4, GE healthcare) The fusion images explain the perfusion defect of anterior, lateral and inferior wall is due to stenosis of the RI and PLB. And 3 days later, coronary angiography was done and revealed the marked stenosis of RI and PLB. Then balloon angioplasty and stent was instituted in RI. Cardiac SPECT/CT fusion imaging provides additional information about hemodynamic relevance and facilitates lesion interpretation by allowing exact allocation of perfusion defects to its subtending coronary artery.

Detection of peri-implant bone defects using cone-beam computed tomography and digital periapical radiography with parallel and oblique projection

  • Saberi, Bardia Vadiati;Khosravifard, Negar;Ghandari, Farnaz;Hadinezhad, Arash
    • Imaging Science in Dentistry
    • /
    • 제49권4호
    • /
    • pp.265-272
    • /
    • 2019
  • Purpose: To compare the diagnostic accuracy of cone-beam computed tomography (CBCT) with that of parallel(PPA) and oblique projected periapical(OPA) radiography for the detection of different types of peri-implant bone defects. Materials and Methods: Forty implants inserted into bovine rib blocks were used. Thirty had standardized bone defects(10 each of angular, fenestration, and dehiscence defects), and 10 were defect-free controls. CBCT, PPA, and OPA images of the samples were acquired. The images were evaluated twice by each of 2 blinded observers regarding the presence or absence and the type of the defects. The area under the receiver operating characteristic curve (AUC), sensitivity, and specificity were determined for each radiographic technique. The 3 modalities were compared using the Fisher exact and chi-square tests, with P<0.05 considered as statistical significance. Results: High inter-examiner reliability was observed for the 3 techniques. Angular defects were detected with high sensitivity and specificity by all 3 modalities. CBCT and OPA showed similar AUC and sensitivity in the detection of fenestration defects. In the identification of dehiscence defects, CBCT showed the highest sensitivity, followed by OPA and PPA, respectively. CBCT and OPA had a significantly greater ability than PPA to detect fenestration and dehiscence defects(P<0.05). Conclusion: The application of OPA radiography in addition to routine PPA imaging as a radiographic follow-up method for dental implantation greatly enhances the visualization of fenestration and dehiscence defects. CBCT properly depicted all defect types studied, but it involves a relatively high dose of radiation and cost.