• 제목/요약/키워드: Defect Imaging

검색결과 267건 처리시간 0.028초

쇄골두개이형성증(Cleidocranial Dysostosis)환자에서 Porous Polyethylene(Medpor®)를 이용한 두개골 함몰의 교정 1례 (Correction of Frontal bone defect in Cleidocranial Dysostosis with Porous Polyethylene(Medpor®): A case report)

  • 모재성;나영천
    • Archives of Plastic Surgery
    • /
    • 제36권4호
    • /
    • pp.481-484
    • /
    • 2009
  • Purpose: Cleidocranial dysostosis is a rare hereditary disorder affecting bones that develop by intramembranous formation. The typical features include excessive growth of transverse diameter of the skull, hypoplastic clavicles, low height and characteristic facial features. Methods: A 28 years old female patient visited by frontal area depression. The diagnosis was performed by computed tomographic study and radiographic imaging. The patient has widely opened anterior fontanelle, partial fused metopic suture, multiple wormian bone and supernumenary impacted teeth. Under the coronal incision, we exposed depressed frontal area and corrected with Medpor block carving. Results: Postoperatively, frontoparietal skull was aestheticlly improved and she was satisfied with the results. Conclusion: Authors report a case of cleiodocranial dysostosis who has been done correction of abnormal skull shape by Medpor$^{(R)}$ insertion.

Tc-99m HMPAO 표지 백혈구스캔상 대퇴 절주에서 우연히 발견된 가성동맥류 (Incidental Detection of a Pseudoaneurysm at an Amputation Stump in a Tc-99m HMPAO labeled Leukocyte Scan)

  • 손명희;정환정;임석태
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권4호
    • /
    • pp.337-338
    • /
    • 2007
  • A 20-year-old man underwent a Tc-99m HMPAO labeled leukocyte scan for the evaluation of an infection at the stump of an AK amputation, which was conducted due to an open communicated fracture of the left lower leg. Blood-flow and blood-pool images demonstrated a pseudoaneurysm with a focus of intense activity medial to the stump, and centered within a large photopenic defect by surrounding hematoma. Delayed image obtained at 3 hours post-injection showed persistent intense and slight increased activity, Contrast angiography confirmed the presence of a pseudoaneurysm arising from a branch of the left superficial femoral artery.

EL-CID를 이용한 발전기 고정자 철심의 건전성 평가 (Healthy Assessment of Generator Stator Cores using EL-CID (ELectromagnetic Core Imperfection Detector))

  • 김병래;김희동
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.356-362
    • /
    • 2009
  • The ELectromagnetic Core Imperfection Detector (EL-CID) test was performed on a small generator in the laboratory and a gas turbine generator in the field to assess the fault condition of generator stator core. Artificial defects with six different sizes were introduced in the small generator. The scan results on six defects show a very large increase in the magnitude of fault current compared to that obtained with a healthy core. After the stator core heats up, a thermal imaging camera was used to detect hot spot on the inner surface of the core for comparison. Several faults were found during inspection of the gas turbine generator with the EL-CID. It has been shown that the existence of a fault can be determined by monitoring the magnitude of fault current.

Control of surface defects on plasma-MIG hybrid welds in cryogenic aluminum alloys

  • Lee, Hee-Keun;Chun, Kwang-San;Park, Sang-Hyeon;Kang, Chung-Yun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제7권4호
    • /
    • pp.770-783
    • /
    • 2015
  • Lately, high production rate welding processes for Al alloys, which are used as LNG FPSO cargo containment system material, have been developed to overcome the limit of installation and high rework rates. In particular, plasma-metal inert gas (MIG) hybrid (PMH) welding can be used to obtain a higher deposition rate and lower porosity, while facilitating a cleaning effect by preheating and post heating the wire and the base metal. However, an asymmetric undercut and a black-colored deposit are created on the surface of PMH weld in Al alloys. For controlling the surface defect formation, the wire feeding speed and nozzle diameter in the PMH weld was investigated through arc phenomena with high-speed imaging and metallurgical analysis.

Double Outlet Right Ventricle in a Cat

  • Hwang, Tae-sung;Noh, Seul-ah;Yoon, Young-min;Yeon, Seong-chan;Lee, Hee-Chun
    • 한국임상수의학회지
    • /
    • 제33권5호
    • /
    • pp.307-309
    • /
    • 2016
  • A 10-month-old intact male Scottish Fold was presented with cardiomegaly. The cat showed exercise intolerance after birth. Radiographs showed cardiomegaly with bulging of the main pulmonary artery and dilation of pulmonary arteries. Echocardiogram revealed abnormally arisen aortic root toward right ventricle with left-to-right shunted perimembraneous ventricular septal defect located underneath the aortic root. Based on imaging studies, the cat was diagnosed as subaortic type of double outlet right ventricle (DORV) without concurrent abnormalities.

Condylar jugular diverticulum: A report of 3 cases

  • Jagtap, Rohan;Wazzan, Taggreed;Hansen, Matthew;Kashtwari, Deeba
    • Imaging Science in Dentistry
    • /
    • 제49권3호
    • /
    • pp.251-256
    • /
    • 2019
  • Jugular bulb diverticulum is an irregular extension of the jugular bulb into the temporal bone that may be symptomatic or asymptomatic. The jugular bulb has rarely been reported to extend into the occipital condyle; such extension is termed a condylar jugular diverticulum and is characterized as a defect in the occipital condyle contiguous with the jugular bulb. This report details 3 cases of condylar jugular diverticulum. Extension of the jugular bulb into the ipsilateral occipital condyle was noted as an incidental finding on cone-beam computed tomographic (CBCT) images of 3 patients. All 3 patients were asymptomatic, and this finding was unrelated to the initial area of interest. CBCT use is becoming ubiquitous in dentistry, as it allows 3-dimensional evaluation, unlike conventional radiography. Proper interpretation of the entire CBCT is essential, and recognition of the indicators of condylar jugular diverticulum may prevent misdiagnosis of this rare entity.

Case report of cerebral creatine deficiency syndrome with novel mutation of SLC6A8 gene in a male child in Bangladesh

  • Rahman, Muhammad Mizanur;Fatema, Kanij
    • Journal of Genetic Medicine
    • /
    • 제18권1호
    • /
    • pp.44-47
    • /
    • 2021
  • Cerebral creatine deficiency syndrome (CCDS) is a disorder where a defect is present in transport of creatine in the brain. Creatine plays an essential role in the energy metabolism of the brain. This is a genetic disorder, autosomal recessive or X linked, characterized by intellectual disability, speech and language delay, epilepsy, hypotonia, etc. Until recently very few number of cases have been reported. Here we report a case of 1.5-year-old boy who had epilepsy (epileptic spasm and generalized tonic clonic seizure), intellectual disability, microcephaly, hypotonia and speech delay. His magnetic resonance imaging of brain showed cortical atrophy and electroencephalography showed burst suppression pattern. The diagnosis was confirmed by clinical exome sequencing which showed novel mutation of SLC6A8+ in exon 9, suggestive of X linked recessive CCDS. The patient was then treated with glycine, L-arginine and creatine monohydrate with multiple antiepileptic drugs.

Clinical evaluation and surgical intervention for diaphragmatic eventration mimicking peritoneopericardial hernia in a cat

  • Min-Jung Ko;Kyoung-Min Song;Hun-Young Yoon
    • Journal of Veterinary Science
    • /
    • 제25권2호
    • /
    • pp.19.1-19.6
    • /
    • 2024
  • A 2-year-old spayed female British Shorthair cat presented with an increased frequency and duration of cough since infant period. Based on radiographic, ultrasonographic, and computed tomography findings, peritoneopericardial diaphragmatic hernia was considered so that repair surgery was planned. During celiotomy, lax diaphragm was identified instead of defect. Transabdominal diaphragmatic plication was performed to resolve lax diaphragm and to prevent recurrence by overlapping relatively normal part of diaphragm. Diagnosed with diaphragmatic eventration postoperatively, the cat showed improvement in clinical signs and imaging results. Transabdominal diaphragmatic plication is a suitable treatment; the patient maintained normally during a 14-month follow-up period.

Tc-99m-MIBI 심근 SPECT에서 재구성필터의 차단주파수에 의한 인위적 관류결손의 정량적 평가 (Quantitative Analysis of Artifactual Perfusion Defects due to the Cutoff Frequencies of Reconstruction Filters in Tc-99m-MIBI Myocardial SPECT Images)

  • 곽철은;정준기;이명철
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권2호
    • /
    • pp.231-238
    • /
    • 1995
  • Tc-99m-MIBI 심근 SPECT에서 심근조직에 비하여 간섭취가 상대적으로 높고 이들이 서로 가까이에 위치해 있는 경우 단축단면상의 하위부 또는 하위중격부에서 발생하는 인위적 관류결손의 정도와 여과기의 차단주파수의 관계를 분석하였다. 이러한 영향은 단축단면상 뿐만 아니라 심근 극성지도에서도 관찰되는데, 심근단층상에서 계수분포가 균일하지 못하고 간과 같이 특정부위에 방사능의 집적도가 높은 경우 단층상 재구성시 차단 파수의 적절한 설정에 따라 이 효과를 줄일 수 있는 방법을 제안하였다. 본 연구에서 분석에 사용된 여과기는 저역통과여과기로 이를 사용하는 경우에는 차단주파수를 0.4Nyquist 이상으로 하면 인위적 관류결손의 정도를 충분히 줄일 수 있었다. 그러나 높은 차단주파수에서는 심근영상의 균일도가 떨어지고 배후방사능 및 기타 잡음요인이 효과적으로 제거되지 않기 때문에 적절한 차단주파수의 설정이 중요하며, 본 연구에 사용된 영상에서 여과방법에 따른 원주프로필의 변화가 미세하여 후처리방법을 사용하여 분석하였다. 또한 역투사방법이 비선형적이므로 특정 영상보다는 다양한 간-심근 방사능비에 따른 영상을 분석하여 비선형성을 배제한 연구가 향후 진행되어야 한다.

  • PDF

비접촉 초음파 탐상기법을 이용한 스폿용접부 및 탄소복합체의 내부 결함평가 (Internal Defection Evaluation of Spot Weld Part and Carbon Composite using the Non-contact Air-coupled Ultrasonic Transducer Method)

  • 곽남수;이승철
    • 한국산학기술학회논문지
    • /
    • 제15권11호
    • /
    • pp.6432-6439
    • /
    • 2014
  • NAUT(Non contact Air coupled Ultrasonic Testing)기법은 초음파 탐상법 중의 하나로서 공기중 음향 임피던스의 차이로 생기는 에너지 손실을 High Power 초음파 Pulser Receiver, PRE-AMP, 고감도의 탐촉자로 보완하여 비접촉식으로 초음파 탐상을 가능하게 하는 탐상 방법이다. NAUT는 초음파의 송신 및 수신이 안정된 상태에서 이루어지므로 기존의 접촉식 탐상으로는 불가능하였던 고온, 저온의 물질이나 시험편의 표면이 거친 부분, 좁은 지점 등에서도 탐상이 가능하다. 본 연구에서는 NAUT기법의 산업체 실용여부를 알아보기 위해 자동차생산 공정에서 많이 사용하는 스폿용접부 및 CFRP 제품에 있어 상용화 연구를 통해 다음과 같은 결과를 얻었다. 본 연구에서는 NAUT기법의 사용 여부를 알아보기 위해 자동차 부품에서 많이 사용하는 스폿용접부 및 CFRP 부품의 내부결함 검출을 검출하였다. 스폿용접부에서는 초음파의 투과율이 높아 적색으로 나타났으며, 복층으로 된 부분은 투과율이 낮아 청색 화상이 나타났다. 또한 측정 속도를 결정하는 중요요소인 PRF(Pulse Repetition Frequency;송신펄스주기)에 따라 색상 선명도의 차이를 보였다. CFRP 시험편 또한 화상장치를 통해 취득된 각 화상 결과를 보고 내부 결함의 모양, 크기, 위치 등의 파악이 단시간에 가능하였다. 실험을 통해 NAUT기법과 화상화가 동시에 이루어짐을 확인하였고, 스폿 용접부와 CFRP 탐상에 NAUT의 적용이 가능한지 그 실현여부를 확인하였다.