• Title/Summary/Keyword: Defect Imaging

Search Result 267, Processing Time 0.03 seconds

A Study on the Non-Destructive Investigation Method of Tile Defect in the Bathroom (욕실 타일 하자에 대한 비파괴 조사 방법에 관한 연구)

  • Jung, Gi-Tae;Kim, Bum-Soo;Lee, Jung-Hun;Song, Je-Young;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.209-210
    • /
    • 2017
  • Recently, bathroom tile defects in households are occurring more frequently. Until now, the destructive investigation method has been required to analyze tile defects. This study proposes a non-destructive using a thermal emission camera imaging as a possibly more precise method of investigating tile failure compared to previous existing methods.

  • PDF

Evaluation of Sympathetic Innervation in Cardiomyopathy with $^{123}I-MIBG$ (심근병에서 $^{123}I-MIBG$ 영상을 이용한 교감신경기능의 평가)

  • Kim, Sun-Jung;Lee, Jong-Doo;Lee, Do-Yun;Park, Chang-Yoon;Ham, Jin-Kyung;Chung, Nam-Sik;Cho, Seung-Yun;Lee, Sung-Sook;Kim, Young-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.195-202
    • /
    • 1993
  • $^{123}Iodine$-metaiodobenzylguanidine (MIBG) which is a norepinephrine analogue, can be used to evaluate the sympathetic innervation of the heart. In this study, cardiac imaging with $^{123}I-MIBG$ was performed in patients with 9 dilated cardiomyopathy, 2 ischemic cardiomyopathy and 1 acute myocardial infarction to evaluate the sympathetic nervous function. $^{123}I-MIBG$ imaging showed multifocal defects (8), diffuse defect (2), near non-visualization (2). The defects of MIBG scans were found to be larger and more severe on 4 hours image than 30 minutes. Heart to lung, heart to mediastinum ratios were decreased at 4 hours than those at 30 minutes. Measured LVEF values were not correlated with the severity of MIBG uptake. $^{99m}Tc-MIBI$ imaging was also performed in all patients to find the relationship with $^{123}I-MIBG$ scan. $^{99m}Tc-MIBI$ scan showed multifocal defects in 9 patients, diffuse defects in 1 patient and no defect in 2 patients. The defects are similar in size, severity and extent, but more larger and severe on $^{123}I-MIBG$ imaging. Therefore, cardiac $^{123}I-MIBG$ imaging is a useful method to evaluate the sympathetic nervous function in cardiomyopathy.

  • PDF

A Simple Multispectral Imaging Algorithm for Detection of Defects on Red Delicious Apples

  • Lee, Hoyoung;Yang, Chun-Chieh;Kim, Moon S.;Lim, Jongguk;Cho, Byoung-Kwan;Lefcourt, Alan;Chao, Kuanglin;Everard, Colm D.
    • Journal of Biosystems Engineering
    • /
    • v.39 no.2
    • /
    • pp.142-149
    • /
    • 2014
  • Purpose: A multispectral algorithm for detection and differentiation of defective (defects on apple skin) and normal Red Delicious apples was developed from analysis of a series of hyperspectral line-scan images. Methods: A fast line-scan hyperspectral imaging system mounted on a conventional apple sorting machine was used to capture hyperspectral images of apples moving approximately 4 apples per second on a conveyor belt. The detection algorithm included an apple segmentation method and a threshold function, and was developed using three wavebands at 676 nm, 714 nm and 779 nm. The algorithm was executed on line-by-line image analysis, simulating online real-time line-scan imaging inspection during fruit processing. Results: The rapid multispectral algorithm detected over 95% of defective apples and 91% of normal apples investigated. Conclusions: The multispectral defect detection algorithm can potentially be used in commercial apple processing lines.

A Case of Atrial Septal Defect (ASD) in a Miniature Schunauzer Dog (Miniature Schunauzer Dog에서 발생한 심방중격 결손 증례)

  • Park, Chul;Choi, Chi-bong;Kim, Il-hwan;Park, Hee-myung
    • Korean Journal of Veterinary Research
    • /
    • v.43 no.2
    • /
    • pp.307-310
    • /
    • 2003
  • An atrial septal defect (ASD) is congenital heart disease with a communication between the atria, which allows blood to shoot from the atrium with pressure. A 3-month-old female Miniature Schunauzer was referred to the Veterinary Teaching Hospital of Konkuk University for the evaluation of systolic heart murmur. At presentation, the mucous membrane was cyanotic. On physical examination, an ejection-type systolic murmur was auscultated at the pulmonic area. In addition, thoracic radiography showed enlargement of main pulmonary artery and right atrial/ventricular enlargement. Echocardiography revealed dilated right atrium and atrial septal defect. However, mitral and tricuspid valve were still intact and well tolerating. The presence of an ASD was confirmed by identifying flow across the defect with color Doppler imaging. Doppler echocardiography provides a means of non-invasive documentation and quantification of ASD. Complete blood count and serum chemistry were not remarkable. Although large defect was confirmed between the two atrium, the patient did not show any obvious clinical signs of heart failure at this time.

Fast Defect Detection of PCB using Ultrasound Thermography (초음파 서모그라피를 이용한 빠른 PCB 결함 검출)

  • Cho Jai-Wan;Seo Yong-Chil;Jung Seung-Ho;Kim Seungho;Jung Hyun-Kyu
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.2
    • /
    • pp.68-71
    • /
    • 2006
  • Active thermography has been used for several years in the field of remote non-destructive testing. It provides thermal images for remote detection and imaging of damages. Also, it is based on propagation and reflection of thermal waves which are launched from the surface into the inspected component by absorption of modulated radiation. For energy deposition, it use external heat sources (e.g., halogen lamp or convective heating) or internal heat generation (e.g., microwaves, eddy current, or elastic wave). Among the external heat sources, the ultrasound is generally used for energy deposition because of defect selective heating up. The heat source generating a thermal wave is provided by the defect itself due to the attenuation of amplitude modulated ultrasound. A defect causes locally enhanced losses and consequently selective heating up. Therefore amplitude modulation of the injected ultrasonic wave turns a defect into a thermal wave transmitter whose signal is detected at the surface by thermal infrared camera. This way ultrasound thermography(UT) allows for selective defect detection which enhances the probability of defect detection in the presence of complicated intact structures. In this paper the applicability of UT for fast defect detection is described. Examples are presented showing the detection of defects in PCB material. Measurements are performed on various kinds of typical defects in PCB materials (both Cu metal and non-metal epoxy). The obtained thermal image reveals area of defect in row of thick epoxy material and PCB.

The Usefulness of Deconvolution Perfusion CT in Patients with Acute Cerebral Infarction : Comparison with Diffusion MRI (급성 뇌경색 환자에서 Deconvolution perfusion CT의 유용성 : Diffusion MRI와 비교)

  • Eun, Sung-Jong;Kim, Young-Keun
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.25-31
    • /
    • 2003
  • This study was performed to evaluate the usefulness of Deconvolution perfusion CT in patients with acute cerebral infarction. Nine patients with acute cerebral infarction underwent conventional CT and cerebral perfusion CT within 23 hours of the onset of symptoms. The perfusion CT scan for each patient was obtained at the levels of basal ganglia and 1cm caudal to the basal ganglia. By special imaging software, perfusion images including cerebral blood volume(CBV), cerebral blood flow(CBF), and mean transit time(MTT) maps were created. The created lesions were evaluated on each perfusion maps by 3 radiolocical technician. MTT delay time was measured in the perfusion defect lesion and symmetric contralateral normal cerebral hemisphere. Lesion sire were measured on each perfusion map and compared with the value obtained by diffusion weighted MR imaging(DWMRI). All perfusion CT maps showed the perfusion defect lesion in all patients. There were remarkable CT delay in perfusion defect lesion. In comparison of lesion size between each perfusion map and DWMRI, the lesion on CBF map was the most closely correlated with the lesion on DWMRI(7/9). The size of perfusion defect lesion on MTT map was larger than that of lesion on DWMRI, suggesting that m map can evaluate the ischemic penumbra. Deconvolution Perfusion CT maps make it possible to evaluate not only ischemic core and ischemic penumbra but also hemodynamic status in perfusion defect area. These results demonstrate that perfusion CT can be useful to the diagnosis and treatment in the patients with acute cerebral ischemic infarction.

  • PDF

The functional imaging to Diagnose Acute Cerebral infarction Comparing between CT Perfusion and MR Diffusion Imaging (급성 뇌경색 진단을 위한 CT관류영상과 MR확산영상의 비교)

  • Kim, Seon-Hee;Eun, Sung-Jong;Rim, Chae-Pyeong
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.19-26
    • /
    • 2012
  • It is very important for early diagnosis and therapy with ischamic cerebral infarction patients. This study was to know the ischemic penumbra lesion which compared CT-perfusion and diffusion weighted MRI(DWMRI) with acute cerebral infarction patients. 12 acute cerebral infarction patients had performed perfusion CT and performed DWMRI. Perfusion images including cerebral blood volume(CBV), cerebral blood flow(CBF), time to peak(TTP) and mean transit time(MTT) maps obtained the values with defect lesion and contralateral normal cerebral hemisphere and DWMRI was measured by signal intensity and compared of lesion size between each perfusion map. All perfusion CT maps showed the perfusion defect lesions in all patients. There were remarkable TTP and MTT delay in perfusion defect lesions. The lesions on CBF map was the most closely correlated with the lesions on DWMRI. The size of perfusion defect lesions on TTP and MTT map was larger than that of lesions on DWMRI, suggesting that MTT map can evaluate the ischemic penumbra. Perfusion CT maps make it possible to evaluate not only ischemic core and ischemic penumbra, but also hemodynamic status in the perfusion defect area. These results demonstrate that perfusion CT can be useful to the diagnosis and treatment in the patients with acute cerebral ischemic infarction.

The Optimization of NDT Method for Real Time X-ray Imaging (X선 실시간 영상장치를 이용한 비파괴시험 조건 최적화 연구)

  • Na, Sung-Youb;Choi, Yong-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.1
    • /
    • pp.19-28
    • /
    • 1996
  • This study has investigated the optimization of NDT method and the minimum detectable defect size for complex structures such as the solid propellant rocket motor using real time X-ray imaging system. Test specimens were made of steel plates with various defect size, and installed with proper thickness for which solid propellant, rubber, and case converted to the steel equivalent thickness according to the radiographic equivalent theory. As the results, this examination obtained optimum magnification and X-ray energy, dose rate according to steel equivalent thickness, also, obtained the relationship between minimum detectable defect size and the ratio(defect depot/object thickness). Thus, this simulated test is the preliminary procedure before performing NDT for real objects, and is possibly applied for NDT of other complex structures.

  • PDF

Measurement Analytical Study of Computed Tomography of the Orbital Structure in Acute Blow-out Fracture (안와파열골절 급성기의 CT영상을 이용한 계측학적인 연구)

  • Jeong, Seong Ho;Shin, Seung Han;Park, Seung Ha;Koo, Sang Hwan
    • Archives of Plastic Surgery
    • /
    • v.34 no.1
    • /
    • pp.44-51
    • /
    • 2007
  • Purpose: Blow-out fracture is one of the most common fractures in facial trauma. It is diagnosed by Computed Tomography(CT) scan, which is considered as the most effective diagnostic tool. Since, the Picture Archiving Communication System(PACS) has been provided recently to many hospitals, doctors are more familiar with imaging software of PACS. Because this software has many useful measuring tools, doctors can measure orbital structure easily and make a plan for treatment with its data. Therefore, authors intended to analyze the data of orbital structure measured with PACS imaging software and evaluate its usefulness. Methods: The charts and CT images of 100 patients, which were 50 patients with medial wall fracture and 50 patients with floor fracture, were reviewed. Patients were selected by pre-determined criteria and their CT images were measured with image software of PACS. 'Extraocular muscle thickness', 'Defect ratio'(ratio of defect area to normal area) and 'Globe position index' were measured and analyzed statistically. Results: The thickness of inferior rectus muscle and medial rectus muscle was simultaneously increased in acute-stage of blow-out fracture. The medial rectus muscle was more thickened in medial wall fracture and inferior rectus was more thickened in floor fracture, respectively. In acute blow-out fracture, globe position is exophthalmic rather than enophthalmic. Especially in floor fracture, numerical value summed up thickness of all extraocular muscle is correlated to the defect ratio and globe position index. Conclusion: Clinicians can decide globe position or presume defect ratio in inferior wall fracture by measurement of CT image in acute blow-out fracture using PACS.

Anomalous Origin of the Coronary Artery from the Pulmonary Artery in Children and Adults: A Pictorial Review of Cardiac Imaging Findings

  • Hyun Woo Goo
    • Korean Journal of Radiology
    • /
    • v.22 no.9
    • /
    • pp.1441-1450
    • /
    • 2021
  • Anomalous origin of the coronary artery from the pulmonary artery is a rare and potentially fatal congenital heart defect. Up to 90% of infants with an anomaly involving the left coronary artery die within the first year of life if left untreated. Patients who survive beyond infancy are at risk of sudden cardiac death. Cardiac CT and MRI are increasingly being used for the accurate diagnosis of this anomaly for prompt surgical restoration of the dual coronary artery system. Moreover, life-long imaging surveillance after surgery is necessary for these patients. In this pictorial review, multimodal cardiac imaging findings of this rare and potentially fatal coronary artery anomaly are comprehensively discussed, and representative images are provided to facilitate the understanding of this anomaly.