Artifactual Perfusion Defects due to the Parameters of Reconstruction Filter in Tc-99m-MIBI Myocardial SPECT Images (Tc-99m-MIBI 심근 SPECT 영상에서 재구성 필터에 의한 인위적 관류결손에 관한 연구)

  • Kwark, Cheol-Eun;Lee, Kyung-Han;Lee, Dong-Soo;Park, Yong-Woo;Chung, June-Key;Lee, Myung-Chul;Seo, Joung-Don;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.41-47
    • /
    • 1995
  • Tc-99m-MIBI(Sestamibi) myocardial SPECT along with T1-201 tomographic imaging has demonstrated wide application and high image qualify sufficient for the diagnosis of myocardial perfusion defect, which consequently reflects regional myocardial blood flow, The qualitative values of myocardial SPECT with Tc-99m-MIBI as well as the quantitative cases depend in some degree on the reconstruction techniques of multiple projections. Filtered backprojection(FBP) is the common standard for reconstruction rather than the complicated and time-consuming arithmetic methods. In FBP it Is known that the distribution of radioactivity in reconstructed transverse slices varies with the selected filter parameters such as cutoff frequencies and order(Butterworth case). The cutoff frequencies basically remove and decrease the true radioactive distribution and alter the pixel counts, which lead to underestimation of true counts in specific myocardial regions. In this study, we have investigated the effect of cutoff frequencies of reconstruction filter on the artifactually induced perfusion defects, which are often demonstrated near inferior and/or inferoseptal cardiac walls due to the intense hepatic uptake of Tc-99m-MIBI. A computerized method for identifying the relative degree of artifactual perfusion defect and for comparing those degrees along with the relative amount of hepatic uptake to myocardium was developed and patient images were studied to observe the quantitative degree of underestimation of myocardial perfusion, and to propose some reasonable thresh-old of cutoff frequency in the diagnosis of perfusion defect quantitatively. We concluded that from the quantitative viewpoint cutoff frequencies may be used as high as possible with the sacrifice of homogeneity of image quality, and those frequencies lower than the common 0.3 Nyquist frequency would reveal severe degradation of radio-active distribution near inferior and/or Inferoseptal myocardium when applying Butterworth or low pass filter.

  • PDF

A Study on Real-Time Defect Detection Using Ultrasound Excited Thermography (초음파 서모그라피를 이용한 실시간 결함 검출에 대한 연구)

  • Cho, Jai-Wan;Seo, Yong-Chil;Jung, Seung-Ho;Jung, Hyun-Kyu;Kim, Seung-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.4
    • /
    • pp.211-219
    • /
    • 2006
  • The UET(ultrasound excited thermography) for the ,eat-time diagnostics of the object employs an infrared camera to image defects of the surface and subsurface which are locally heated using high-frequency putted ultrasonic excitation. The dissipation of high-power ultrasonic energy around the feces of the defects causes an increase In temperature. The defect's image appears as a hot spot (bright IR source) within a dark background field. The UET for nondestructive diagnostic and evaluation is based on the image analysis of the hot spot as a local response to ultrasonic excited heat deposition. In this paper the applicability of VET for fast imaging of defect is described. The ultrasonic energy is injected into the sample through a transducer in the vertical and horizontal directions respectively. The voltage applied to the transducer is measured by digital oscilloscope, and the waveform are compared. Measurements were performed on four kinds of materials: SUS fatigue crack specimen(thickness 14mm), PCB plate(1.8 mm), CFRP plate(3 mm) and Inconel 600 plate (1 mm). A high power ultrasonic energy with pulse durations of 250ms Is injected into the samples in the horizontal and vertical directions respectively The obtained experimental result reveals that the dissipation loss of the ultrasonic energy In the vertical injection is less than that in the horizontal direction. In the cafe or PCB, CFRP, the size of hot spot in the vortical injection if larger than that in horizontal direction. Duration time of the hot spot in the vertical direction is three times as long as that in the horizontal direction. In the case of Inconel 600 plate and SUS sample, the hot spot in the horizontal injection was detected faster than that in the vertical direction

Visual Disturbance following Autologous Fat Injection into Periorbital Area (안와부 자가지방이식술 후 시력 저하에 대한 증례보고)

  • Jeon, Young Woo;Kim, Sung Soo;Ha, Sang Wook;Lee, Young Dae;Seul, Chul Hwan;Tark, Kwan Chul;Cho, Eul Jae;Yoo, Won Min
    • Archives of Plastic Surgery
    • /
    • v.34 no.5
    • /
    • pp.663-666
    • /
    • 2007
  • Purpose: Autologous fat injection into the facial area is a frequently used technique in aesthetic plastic surgery for augmentation of the soft tissue. Fat injection is a very safe procedure because of the advantage of being autologous tissue. Minimal foreign body reaction or infections are noted after fat injection. However, there may be some complications including those as severe as blindness. There have been some case reports on visual disturbances after autologous fat injection reported in the literature. Methods: A 21-year-old female patient underwent autologous fat injection into left eyebrow area to correct depression of soft tissue. Immediately after injection of autologous fat, she complained sudden visual loss on the left eye. She had come to our emergency room and ophthalmologic evaluation showed that the patient could only recognize hand motion. There was no abnormality of the optic nerve on magnetic resonance imaging. Suspecting an ischemic optic neuritis from fat embolism of the central retinal artery, the patient was treated conservatively with occular massage, antiglaucomatic agent, anti-inflammatory drugs and antibiotics. Visual field examination showed visual defect of half the lower hemisphere. Results: While maintaining antiglaucomatic agents and non steroidal anti inflammatory drugs, fundoscopic examination showed no abnormalities on the second day of admission. Visual field examination showed an improvement on the fourth day along with decreased eyeball pain. Significant improvement of vision was noted and the patient was discharged on the fifth day of admission. The patient was followed-up 2 days afterwards with improved vision and visual field defect. Conclusion: We describe an unusual case of sudden unilateral visual disturbance following autologous fat injection into periorbital area.

A Study on the Determination of the Appropriate Imaging Conditions in the Use of Scintillation Camera (Scintillation Camera 사용시(使用時) 적정(適正)한 촬상조건(撮像條件)의 설정(設定)에 관(關)한 연구(硏究))

  • Huh, Joon;Kyong, Kwang-Hyon
    • Journal of radiological science and technology
    • /
    • v.6 no.1
    • /
    • pp.103-113
    • /
    • 1983
  • Scintillation cameras을 사용(使用)할때 양질(良質)의 화상(畵像)을 얻기 위하여 camera의 성능(性能), 방사성의약품(放射性醫藥品)의 특성(特性), 그리고 적정(適正)한 촬상조건(撮像條件)을 고려할 필요(必要)가 있다. 특(特)히 RI 상(像)에 대한 촬상조건(撮像條件)은 film의 성질(性質), 상(像)의 크기, 상(像)의 농도(濃度), window, 그리고 콜리메타 전면(前面)으로부터 거리(距離) 등(等)에 따라서 좌우(左右)된다. 이러한 요인(要因)들은 각각 화상(畵像)을 만드는 과정에 영향(影響)을 미치고 있다. 그러므로 상(像)의 표준화(標準化)와 촬상방법(撮像方法)의 기준(基準)을 확립(確立)하기가 매우 어렵다. 고로 이러한 문제(問題)들을 해결(解決)하는 것은 Scintillation camera을 사용(使用)하는 핵의학적(核醫學的) 검사(檢査)에 있어서 매우 중요(重要)하다. 저자(著者)는 이러한 점(點)을 고려하여 일정(一定)한 상(像)의 농도(濃度)을 얻을 수 있는 촬상조건(撮像條件)에 대(對)하여 실험(實驗)을 하였다. 실험(實驗)에 있어서 평행다공형(平行多孔型) 콜리메타를 camera의 head에 부착(附着)시키고 $^{99m}Tc$(3mCi)가 넣어져 있는 liver phantom을 콜리메타의 표면(表面)에 밀착(密着)시켜 다음과 같은 방법(方法)에 의하여 촬상(撮像)하였다. 즉, 일정(一定)한 상(像)의 농도(濃度)을 얻을 수 있는 촬상조건(撮像條件)을 찾아낼 목적(目的)으로 preset time, image size, 콜리메타전면(前面)- phantom간(間) 거리(距離), 그리고 window를 각각(各各) 변화(變化)시키면서 phantom을 촬상(撮像)하였으며, 특(特)히 거리(距離)와 window에 있어서는 cold defects의 검출능(檢出能)도 비교검토(比較檢討)하였다. 실험결과(實驗結果)는 다음과 같다. 1. C type film에 있어서 1.5의 농도(濃度)을 얻기위해서는 7.5의 intensity 에서 preset time은 60초(秒), image size는 1.0, 콜리메타-phantom간거리(間距離)는 0cm 그리고 window는 20%가 요구(要求)되고 있었다. 2. 편면유제(片面乳劑) film의 preset time은 양면유제(兩面乳劑) film보다 짧은 것으로 나타났다. 3. 상(像)의 분해능(分解能)은 image size가 작을수록, 콜리메타-phantom간(間) 거리(距離)가 짧을수록, 그리고 window 폭(幅)이 좁을수록 더욱 더 향상(向上)되고 있었다. 4. Cold defects의 검출능(檢出能)은 image size가 작을수록, 콜리메타-pantom간(間) 거리(距離)가 짧을수록, 그리고 window폭(幅)이 좁을수록 향상(向上)되고 있었다.

  • PDF

Orbital Volume Change Resulted from Packing in Ethmoidal Sinus for Correction of Isolated Medial Orbital Fractures (안와내벽파열골절의 내시경적 사골동내 충전에 따른 안와용적 변화)

  • Kim, Kyoung-Hoon;Choi, Soo-Jong;Kang, Cheol-Uk;Bae, Yong-Chan;Nam, Su-Bong
    • Archives of Craniofacial Surgery
    • /
    • v.10 no.1
    • /
    • pp.7-13
    • /
    • 2009
  • Purpose: Endoscopic transnasal correction of the medial orbital fractures cannot be enable to confirm the reduction degree of orbital volume without imaging modalities. We have intended through this study to make a quantative analysis of preoperative orbital volume increment and the reduction degree of that after ethmoidal sinus packing by using CT scan. Methods: In this retrospective study, 22 patients were selected to evaluate the postoperative volume reduction, who took 2 CT scans which are pre- and postoperative under the same protocol. The postoperative CT scan was carried out in about 5 days after the operation with the packing inserted into ethmoidal sinus. The length of bony defect on each section was measured by PACS program and the area of defect was calculated by summing lengths on each section multiplied by the thickness of the section. When the outline of orbit on the slice is drawn manually with a cursor, PACS program measures the area automatically. Orbital volume was calculated from the sum of the area multiplied by the section thickness. Results: The mean dimension of fractured walls was $2.86{\pm}0.99cm^2$. The mean orbital volume of the unaffected orbits was $22.89{\pm}2.15cm^3$ and that of the affected orbits was $25.62{\pm}2.82cm^3$. The mean orbital volume increment of the affected orbits was $2.73{\pm}1.13cm^3$. After surgery, the mean orbital volume of the unaffected orbits was $22.46{\pm}2.73cm^3$ and the mean orbital volume decrease on the surgical side was $2.98{\pm}1.07cm^3$. The estimated correction rate was 118.30%. Conclusion: The orbital volume increment in fractured orbit showed linear correlation with the dimension of fractured area. The orbital volume changes after ethmoidal sinus packing also showed linear correlation with orbital volume increment in fractured orbit. This study showed the regressive linear correlation between the increment of orbital volume and the correction rate. To evaluate the maintenance of reduction state, we think that the further study should be done for comparative analysis of orbital volume change after removal of packing.

Measurement of Shunt Amount Using Radionuclide Angiocardiography: Accuracy According to Level of Shunt and Associated Lesion (방사성 동위원소 심혈관 조영술을 이용한 단락량 측정법: 정확성에 영향을 미치는 인자)

  • Kim, Yang-Min
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.4
    • /
    • pp.200-204
    • /
    • 2006
  • Purpose: Determination of pulmonary to systemic blood flow ratio (QP/QS) is important for the management of patients with left-to-right shunt. This study was performed to assess the agreement of Qp/Qs ratio using the radionuclide method and oxymetry, to investigate the factors influencing the agreement, and to know how interchangeable the results of each technique. Materials and Methods: We compared the Qp/Qs measured by single-pass radionuclide angiocardiography and oxymetry during catheterization in 207 patients who underwent both studies. In radionuclide method, Qp/Qs was calculated from the pulmonary time-activity curves using a gamma variate fit. The correlation and Bland-Altman analysis were performed according to the levels of shunt and associated lesions. Results: The mean Qp/Qs was $1.83{\pm}0.50$ by radionuclide, and $1.74{\pm}0.51$ by oxymetry. The overall correlation coefficient was 0.86(p<0.001), and Bland-Altman range of agreement encompassing 4SD was 1.05. For atrial septal defect, ventricular septal defect, patent ductus arteriosus, tricuspid and mitral insufficiency, the correlation coefficient was 0.78, 0.90, 0.84, 0.63 and 0.44, and Bland-Altman range was 1.51, 0.74, 0.96, 1.57, and 1.50, respectively. Conclusion: There is good agreement but wide variance between the Qp/Qs ratios by radionuclide method and oxymetry. Associated atrioventricular valvar insufficiency decreases the correlation coefficient and widens the variance. Wide overall variance suggests that Qp/Qs measurements by two techniques should not be used interchangeably.

Comparison of $^{99m}Tc-MIBI$ Myocardial Uptake at Rest with Reinjection and 24-hour after Reinjection Images of $^{201}Tl$ ($^{201}Tl$$^{99m}Tc-MIBI$에 의한 생존심근의 진단 비교 -재분포영상에 고정관류결손을 보인 환자에서 $^{201}Tl$ 재주사법 및 $^{99m}Tc-MIBI$ 휴식기스캔에 의한 심근섭취 비교-)

  • Bom, Hee-Seung;Kim, Ji-Yeul;Park, Joo-Hyung;Ahn, Young-Keun;Jeong, Myung-Ho;Cho, Jeong-Gwan;Park, Jong-Choon;Kang, Jung-Chaee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.274-279
    • /
    • 1992
  • Clinical role of $^{99m}Tc-MIBI$ myocardial scintigraphy in the diagnosis of coronary artery disease (CAD) is now well accepted, however, the role of it in the identification of viable myocardium in patients with chronic CAD has not yet been clarified. To determine the usefulness of rest-injected $^{99m}Tc-MIBI$ scan as a marker of myocardial viability, the regional uptake of this agent at rest was compared with that of $^{201}Tl$ on reinjection and 24 hours after reinjection images. Subject patients were 13 chronic CAD patients who showed irreversible perfusion defect(s) on standard pharmacologic (dipyridamole) stress-redistribution images. Immediately after the redistribution images were obtained, 37 MBq thallium was injected at rest, and images were reacquired at 10 minutes and 24 hours after reinjection. After then 740 MBq $^{99m}Tc-MIBI$ was injected, and 1 hour later rest MIBI myocardial imaging was performed. Five sets of imagestress, redistribution, reinjection, delayed images of thallium, and rest image of MIBI) were then analyzed qualitatively and quantitatively. Left ventricle was arbitrarily divided into 9 segments (apex, basal and apical portions of anterior, septal, inferior, and lateral walls). Seven patients and 30 regions showed a fixed perfusion defect on the stress-redistribution images. Among 30 regions, 15 showed positive uptakes and 6 showed negative uptakes on both $^{201}Tl$ reinjection/delayed images and $^{99m}Tc-MIBI$ rest images. Five regions showed only thallium uptake and were regarded as viable clinically. Of four regions which showed only $^{99m}Tc-MIBI$ uptake, two were regarded as viable, while the other two were regarded as a nonviable scar tissue clinically. In conclusion, $^{201}Tl$ reinjection technique was more reliable in the identification of viable myocardium. However, the role of $^{99m}Tc-MIBI$ in identification of viable myocardium was still remained to be clarified because 2 of 9 regions showed only $^{99m}Tc-MIBI$ uptake and were regarded as viable tissues.

  • PDF

Bone Marrow Immunoscintigraphy for the Detection of Skeletal Metastasis in Malignant Tumors: A Comparison with $^{99m}Tc$-MDP Bone Scan (악성종양에서 골수면역신티그라피를 이용한 골수전이의 평가 : $^{99m}Tc$-MDP 뼈스캔과의 비교)

  • Lee, Kyung-Han;Choi, Chang-Woon;Bang, Yung-Jue;Chung, Jun-Key;Chung, Hong-Keun;Lee, Myoung-Chul;Kim, Byoung-Kook;Kim, Noe-Kyeong;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.89-97
    • /
    • 1994
  • Although bone scan is a highly sensitive test for detecting bone metastasis, its findings are often limited in specificity and cannot be used for assessing the bone marrow. Bone marrow scintigraphy may provide useful information but previous experience with radiolabelled colloid has been disappointing. Recently, $^{99m}Tc$ labeled anti-granulocyte monoclonal antibody (anti-NCA-95 MAb) has been introduced as a new bone marrow imaging agent. To evaluate the usefulness of $^{99m}Tc$ anti-NCA MAb bone marrow scans for detecting skeletal metastasis, bone marrow scans of 44 malignant tumor patients were evaluated and compared with bone scan findings. Bone scan showed abnormal lesions in 26(59%) cases, and 18 of these patients also had an abnormal bone marrow scan. Seven of the 8 patients who had normal bone marrow scan despite bone scan lesions were confirmed to be free from metastasis. There was one case with a marrow defect despite normal bone scan but the presence of metastasis was not determined due to loss of follow up. Bone scan demonstrated a total of 64 lesions while bone marrow scan showed 38 lesions. Fifty percent (32/64) of the bone scan lesions had matching marrow defects while the remaining 50% did not. Most of these non matched lesions were suggested to be nonspecific lesions such as rib fractures or degenerative change. Meanwhile bone marrow scan was able to detect 6 new lesions not detected by bone scan, bit metastasis in each lesion was not confirmed. Bone marrow scan was also helpful in assessing equivocal bone scan lesions to be of metastatic nature in 10 patients by demonstrating a matched marrow defect. Thus $^{99m}Tc$ anti-NCA MAb bone marrow scan can help exclude metastasis in patients with nonspecific bone scan lesions and may be able to detect metastatic lesions not seen with bone scan. It appears useful as a complementary study to bone scan in evaluating malignant tumor patients.

  • PDF

Transport parameters in a-Se:As films for digital X-ray conversion material using the moving-photocarrier-grating technique (moving-photocarrier-grating 기술을 이용한 디지털 X-선 변환물질 a-Se:As의 수송변수)

  • Park, Chang-Hee;Nam, Sang-Hee;Kim, Jae-Hyung
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.267-272
    • /
    • 2005
  • The effects of As addition in amorphous selenium (a-Se) films for digital X-ray conversion material have been studied using the moving photocarrier grating (MPG) technique. This method utilizes the moving interference pattern generated by the superposition of the two frequency shifted laser beams for the illumination of the sample. This moving intensity grating induces a short circuit current, jsc in a-Se:As film. The transport parameters of the sample are extracted from the grating-velocity dependent short circuit current induced in the sample along the modulation direction. The electron and hole mobility, and recombination lifetime of a-Se films with arsenic (As) additions have been obtained. We have found an increase in hole drift mobility and recombination lifetime, especially when 0.3% As is added into a-Se film, whereas electron mobility decreases with As addition due to the defect density. The transport properties for As doped a-Se films obtained by using MPG technique have been compared with X-ray sensitivity for a-Se:As device. The fabricated a-Se(0.3% As) device film exhibited the highest X-ray sensitivity out of 5 samples.

  • PDF

Brain SPECT Using $^{99m}Tc$-HMPAO and $^{99m}Tc$-ECD in Subacute Cerebral Infarction: Case Report (아급성 뇌경색 환자에서 $^{99m}Tc$-HMPAO 및 $^{99m}Tc$-ECD 뇌 SPECT: 증례보고)

  • Ahn, Byeong-Cheol;Lee, Dong-Soo;Yoon, Byung-Woo;So, Young;Jung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.570-575
    • /
    • 1996
  • For brain perfusion SPECT imaging, $^{99m}Tc$-HMPAO and $^{99m}Tc$-ECD are commonly used. Although these two tracers usually show similar distribution, it is well known that discrepant finding might be noted between $^{99m}Tc$-HMPAO and $^{99m}Tc$-ECD imaging in some conditions. Luxury perfusion(perfusion/metabolism mismatch) is one of the examples and could be observed in subacute cerebral infarction. We report a case of subacute cerebral infarction that revealed luxury perfusion. Increased perfusion was found in $^{99m}Tc$-HMPAO SPECT and perfusion defect was found in $^{99m}Tc$-ECD SPECT. We found large area of mismatch with a consecutive acquisition-subtraction method. Crossed cerebellar diaschisis was observed in both SPECT images.

  • PDF