• Title/Summary/Keyword: Defect Assessment

Search Result 248, Processing Time 0.031 seconds

Web Uni-Limb Z-Plasty for Correction of Alar Web Deformity in Unilateral Cleft Lip Nasal Deformities: Photogrammetric Analysis (일측구순열비변형에서 물갈퀴일측지Z성형술을 이용한 외비공과 비주의 재건: 사진계측학적 연구)

  • Han, Ki-Hwan;Kim, Dae-Jin;Park, Mu-Shik;Kim, Jun-Hyung;Son, Dae-Gu
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.740-746
    • /
    • 2011
  • Purpose: In the treatment of the unilateral cleft lip nasal deformities, the correction of the low-nostril height and short-columella are very difficult problems. We report the treatment outcomes of web uni-limb Z-plasty used for correction of unilateral cleft lip nasal deformities by using photographic analysis. Methods: A total of 36 patients with unilateral cleft lip nasal deformities were enrolled in this study, who underwent web uni-limb Z-plasty and were followed up for at least 6 months. First, a triangular flap was made on the medial side of alar-columella web. The nostril apex of cleft side was corrected to a higher point compared to noncleft side by 2 mm. The flap was transposed into the defect of the vestibule. To reduce the bulging of the flap, horizontal cinching sutures were added. Postoperative outcomes were evaluated by using photographic analysis. 2 indices and 1 angle were measured on their photographs taken before and after the surgery. Symmetry was also evaluated by means of the noncleft side to cleft side index. For anthropologic assessment, observers described postoperative outcomes, using Ordinary Scale Method. Results: The postoperative values obtained in photographic analysis improved compared to preoperative ones. More improving anthropologic assessment was shown in post-than pre-operative. Conclusion: Although, further long term follow up is needed, we found this technique to be an effective procedure to the symmetry of nostril apex level and the lengthening of columella in the unilateral cleft lip nasal deformities.

Automatic Detection of Foreign Body through Template Matching in Industrial CT Volume Data (산업용 CT 볼륨데이터에서 템플릿 매칭을 통한 이물질 자동 검출)

  • Ji, Hye-Rim;Hong, Helen
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.12
    • /
    • pp.1376-1384
    • /
    • 2013
  • In this paper, we propose an automaticdetection method of foreign bodies through template matching in industrial CT volume data. Our method is composed of three main steps. First,Indown-sampling data, the product region is separated from background after noise reduction and initial foreign-body candidates are extracted using mean and standard deviation of the product region. Then foreign-body candidates are extracted using K-means clustering. Second, the foreign body with different intensity of product region is detected using template matching. At this time, the template matching is performed by evaluating SSD orjoint entropy according to the size of detected foreign-body candidates. Third, to improve thedetection rate of foreign body in original volume data, final foreign bodiesare detected using percolation method. For the performance evaluation of our method, industrial CT volume data and simulation data are used. Then visual inspection and accuracy assessment are performed and processing time is measured. For accuracy assessment, density-based detection method is used as comparative method and Dice's coefficient is measured.

Assessment of Multiple Delamination in Laminated Composites for Aircrafts using X-ray Backscattering (X-ray 후방산란 기술을 이용한 항공기용 복합재료의 다중 층간 박리 평가)

  • Kim, Noh-Yu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.1
    • /
    • pp.46-53
    • /
    • 2010
  • A Compton X-ray backscatter technique has been developed to quantitatively assess impact damage in quasi-isotropic laminated composites made by a drop-weight tester. X-ray backscatter imaging system with a slit-type camera is constructed to obtain a cross-sectional profile of impact-damaged laminated composites from the electron-density variation of the cross section. A nonlinear scattering model based on Boltsman equation is introduced to compute Compton X-ray backscattering field for the defect assessment. An adaptive filter is also used to reduce noises from many sources including quantum noise and irregular distributions of fibers and matrix in composites. Delaminations masked or distorted by the first delamination are detected and characterized effectively by the Compton X-ray backscatter technique, both in width and location, by application of error minimization algorithm.

Post Closure Long Term Safety of an Initial Container Failure Scenario for a Potential HLW Repository (고준위 방사성폐기물 처분장에서 초기 용기 파손 시나리오의 장기 방사선적 안전성 평가)

  • 황용수;서은진;이연명;강철형
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.229-232
    • /
    • 2003
  • A waste container, one of the key compartments in a multi-barrier system for a potential high level radioactive waste (HLW) repository in Korea ensures the mechanical stability against the lithostatic pressure of a deep geologic strata and the swelling pressure of the bentonite buffer. Also, it prohibits potential release of radionuclides for a certain period of time. before it is corroded by impurities. Even though the materials of a waste container is carefully chosen and all manufacturing processes are under heavy quality assurance, there might be a slight chance of intial defects in a waste container. Also, during the deposition of a waste container in a repository, there might be a chance of an incident affecting the integrity of a waste container. In this study, the FEP's and the scenarios over radiological impact of a potential initial waste container defect was developed. Then the total system performance assessment on this initial waste container failure (ICF) scenario was carried out by the MASCOT-K, one of the probabilistic safety assessment tools KAERI has developed. Results show that for the data set studied in this paper, the annual individual dose by the ICF scenario well meets the KINS regulation.

  • PDF

Evaluation of Tension of PSC Box Girder Bridges Using Risk Matrix (리스크 매트릭스를 활용한 PSC박스 거더교의 긴장재 평가)

  • Kim, Hyungjo;Ji, Seunggu;Kim, Hunkyom;Kim, Pilsoo;Kim, Hunkyom;Lee, Minjae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.5
    • /
    • pp.53-60
    • /
    • 2018
  • In particular, the investigation of tendons in PSC Box Girder Bridge should be done in a systematic way. It is important to identify preventative maintenance activities that should be carried out in order to analyze the risk factors by type of representative tensions and to reduce risks in the long term. However, in the current maintenance system, various methodologies for investigating and repairing tensions have been studied, but it is difficult to investigate precisely tensions. Therefore, to apply the risk assessment for screening of tensions to the domestic PSC Box Bridge, we presented a risk matrix evaluation index that is consistent with the state assessment and maintenance system.

A Study on the Fracture Behavior of a Crack in 9% Ni Steel Considering Constraint Effect (구속효과를 고려한 9% Ni강 균열의 파괴거동 해석에 관한 연구)

  • Kim, Young Kyun;Yoon, Ihn soo;Kim, Jae Hoon
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.6
    • /
    • pp.14-21
    • /
    • 2021
  • Inner shell material of LNG storage tanks that store ultra-low temperature LNG at -162℃ requires structural integrity assessment of a crack-like defect. From the viewpoint of conventional fracture mechanics, the assessment has mainly performed by single parameter using stress intensity factor K, J-integral and CTOD. However, the stresses in a material of crack tip are not unique caused by constraint loss due to size and geometry of the structure. Various attempts have been made to complement a single parameter fracture mechanics, typically with Q-stress. In this paper, we have performed a two-parameter approach by deriving the Q-stress coupling with J-integral suitable for the evaluation of the crack tip stress field in the non-linear elastic region. A quantitative evaluation of the constraint effect has performed by using the J-Q approach. It was evaluated that the SENB type specimen had a crack ratio of 0.1 to 0.7 and the wide type specimen had a crack ratio of 0.2 to 0.6.

A Method for Information Management of Defects in Bridge Superstructure Using BIM-COBie (BIM-COBie를 활용한 교량 상부구조의 손상정보 관리 방법)

  • Lee, Sangho;Lee, Jung-Bin;Tak, Ho-Kyun;Lee, Sang-Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.2
    • /
    • pp.165-173
    • /
    • 2023
  • The data management and the evaluation of defects in the bridge are generally conducted based on inspection and diagnosis data, including the exterior damage map and defect quantity table prepared by periodic inspection. Since most of these data are written in 2D-based documents and are difficult to digitize in a standardized manner, it is challenging to utilize them beyond the defined functionality. This study proposed methods to efficiently build a BIM (Building Information Modeling)-based bridge damage model from raw data of inspection report and to manage and utilize the damage information linking to bridge model through the spread sheet data generated by COBie (Construction Operations Building Information Exchange). In addition, a method to conduct the condition assessment of defects in bridge was proposed based on an automatic evaluation process using digitized bridge member and damage information. The proposed methods were tested using superstructure of PSC-I girder concrete bridge, and the efficiency and effectiveness of the methods were verified.

Analysis for Defect Evaluation of Pipes in Nuclear Power Plant (원전 배관의 결함 평가를 위한 해석)

  • Lee, Joon-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3121-3126
    • /
    • 2013
  • The integrity evaluation of pipes in nuclear power plant are essential for the safety of reactor vessel, and integrity must be assured when flaws are found. Accurate stress intensity analyses and crack growth rate data of surface-cracked components are needed for reliable prediction of their fatigue life and fracture strengths. Fatigue design and life assessment are the essential technologies to design the structures such as pipe, industrial plant equipment and so on. The effect of crack spacing on stress intensity factor K values was studied using three-dimensional finite element method (FEM). For the case of cylinder under internal pressure, a significant increase in K values observed at the deepest point of the surface crack. Also, this paper describes the fatigue analysis for cracked structures submitted to bending loads.

Magnetic Resonance Imaging (MRI) of a Hypertrophy of Cartilage and Simultaneous Regeneration of a Damaged Meniscus after Autologous Bone Marrow Aspirates Concentrate (BMAC) Transplantation: a Case Report and Literature Review

  • Bae, Sung Hwan;Kim, Hyun-joo;Oh, Eunsun;Hwang, Jiyoung;Hong, Seong Sook;Hwang, Jung Hwa
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.3
    • /
    • pp.187-191
    • /
    • 2017
  • Bone marrow aspirates concentrate (BMAC) transplantation is a well-known technique for cartilage regeneration with good clinical outcomes for symptoms in patients with osteoarthritis (OA). Magnetic resonance imaging (MRI) has an important role in evaluating the degree of cartilage repair in cartilage regeneration therapy instead of a second assessment via an arthroscopy. We experienced a case of hypertrophic regeneration of the cartilage and a presumed simultaneous regeneration of the posterior horn of the lateral meniscus after BMAC transplantation for a cartilage defect at the lateral tibial and femoral condyle. This report provides the details of a case of an unusual treatment response after a BMAC transplant. This report is the first of its kind to demonstrate a MR image that displays the simultaneous regeneration of the cartilage and meniscus with a differentiation ability of the mesenchymal stem cell to the desired cell lineage.

Residual static strength of cracked concrete-filled circular steel tubular (CFCST) T-joint

  • Cui, M.J.;Shao, Y.B.
    • Steel and Composite Structures
    • /
    • v.18 no.4
    • /
    • pp.1045-1062
    • /
    • 2015
  • Concrete-filled circular t steel tubular joints (CFSTJs) in practice are frequently subjected to fluctuated loadings caused by wind, earthquake and so on. As fatigue crack is sensitive to such cyclic loadings, assessment on performance of CFSTJs with crack-like defect attracts more concerns because both high stress concentration at the brace/chord intersection and welding residual stresses along weld toe cause the materials in the region around the intersection to be more brittle. Once crack initiates and propagates along the weld toe, tri-axial stresses in high gradient around the crack front exist, which may bring brittle fracture failure. Additionally, the stiffness and the load carrying capacity of the CFSTJs with crack may decrease due to the weakened connection at the intersection. To study the behaviour of CFSTJs with initial crack, experimental tests have been carried out on three full-scale CFCST T-joints with same configuration. The three specimens include one uncracked joint and two corresponding cracked joints. Load-displacement and load-deformation curves, failure mode and crack propagation are obtained from the experiment measurement. According to the experimental results, it can be found that he load carrying capacity of the cracked joints is decreased by more than 10% compared with the uncracked joint. The effect of crack depth on the load carrying capacity of CFCST T-joints seems to be slight. The failure mode of the cracked CFCST T-joints represents as plastic yielding rather than brittle fracture through experimental observation.