• Title/Summary/Keyword: Defect

Search Result 8,078, Processing Time 0.045 seconds

Clinical Cases Analysis of Forearm Free Fasciocutaneous Flaps on Oral Cavity Defect Area (구강 결손부에 적용된 요골 유리전완 피부피판 적용례 분석)

  • Kim, Uk-Kyu;Lee, Kwang-Ho;Song, Won-Wook;Hwang, Dae-Seok;Kim, Yong-Deok;Shin, Sang-Hun;Kim, Jong-Ryoul;Chung, In-Kyo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.4
    • /
    • pp.324-331
    • /
    • 2010
  • The radial forearm free flap (RFFF) has become a workhorse flap as a means of reconstructing surgical defects in the head and neck region. We have transferred 12 RFFFs with fasciocutaneous type on oral cavity defects in 12 patients after cancer resection and submucous fibrotic lesion ablation from 2005 to 2007 at Department of oral and maxillofacial surgery, Pusan National University Hospital. We reviewed retrospectively patients' charts and followed up the patients. Clinical analysis on the cases with RFFFs focusing on flap morbidity, indications and available vessels was done. The results of study are follows: 1. RFFF could be applied for all kind of defects after resection of tongue, floor of mouth, buccal mucosa, denuded bone of palate, maxilla, and mandible. 2. All free flaps could be used for primary reconstruction. The survival rate of 12 RFFFs was 92%. Partial marginal loss of the flaps was shown as 3 cases among 12 cases. Large size-vessels like superior thyroid artery, facial artery, internal jugular vein were favorable for microvascular anastomosis. 3. Parenteral nutrition instead of nasal L-tube also can be favorable for postoperative a week for better healing of the flap if the patients couldn't be tolerable with nasal tubing. 4. Donor sites with thigh skin graft were repaired with wrist band for 2 weeks. The complications included scarring, abnormal sensation on hand, and reduced grip strength in few patients, but those didn't induce major side effects. 5. Most RFFFs were well healed even if mortality rate of cancer patients was shown as 50% (5/10 persons). The mortality of patients was not correlated with morbidity of the flaps. We could identify the usefulness of RFFF for restoration of oral function, esthetics if the flap design, tissue transfer indications, and well controlled operation are proceeded.

Maxillary reconstruction using tunneling flap technique with 3D custom-made titanium mesh plate and particulate cancellous bone and marrow graft: a case report

  • Takano, Masayuki;Sugahara, Keisuke;Koyachi, Masahide;Odaka, Kento;Matsunaga, Satoru;Homma, Shinya;Abe, Shinichi;Katakura, Akira;Shibahara, Takahiko
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.43.1-43.5
    • /
    • 2019
  • Background: Reconstructive surgery is often required for tumors of the oral and maxillofacial region, irrespective of whether they are benign or malignant, the area involved, and the tumor size. Recently, three-dimensional (3D) models are increasingly used in reconstructive surgery. However, these models have rarely been adapted for the fabrication of custom-made reconstruction materials. In this report, we present a case of maxillary reconstruction using a laboratory-engineered, custom-made mesh plate from a 3D model. Case presentation: The patient was a 56-year-old female, who had undergone maxillary resection in 2011 for intraoral squamous cell carcinoma that presented as a swelling of the anterior maxillary gingiva. Five years later, there was no recurrence of the malignant tumor and a maxillary reconstruction was planned. Computed tomography (CT) revealed a large bony defect in the dental-alveolar area of the anterior maxilla. Using the CT data, a 3D model of the maxilla was prepared, and the site of reconstruction determined. A custom-made mesh plate was fabricated using the 3D model (Okada Medical Supply, Tokyo, Japan). We performed the reconstruction using the custom-made titanium mesh plate and the particulate cancellous bone and marrow graft from her iliac bone. We employed the tunneling flap technique without alveolar crest incision, to prevent surgical wound dehiscence, mesh exposure, and alveolar bone loss. Ten months later, three dental implants were inserted in the graft. Before the final crown setting, we performed a gingivoplasty with palate mucosal graft. The patient has expressed total satisfaction with both the functional and esthetic outcomes of the procedure. Conclusion: We have successfully performed a maxillary and dental reconstruction using a custom-made, pre-bent titanium mesh plate.

THE EFFECTS OF IRRADIATION AND HYPERBARIC OXYGEN THERAPY ON MICROVASCULAR ANASTOMOSIS (방사선조사 및 고압산소요법이 미세혈관 문합술에 미치는 영향)

  • Choi, Sung-Weon;Kim, Byung-Yong;Park, Jung-Hyun;Yoon, Jung-Hoon;Yook, Jong-In;Yoo, Jae-Ha;Lee, Eui-Woong;Cha, In-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.5
    • /
    • pp.455-461
    • /
    • 2000
  • Malignant tumors of the head and neck frequently require treatment with both radiotherapy and surgery. Reconstruction of the defect in previously irradiated field is a challenge to surgeon, who must produce both a functional and an esthetic result. Hyperbaric oxygen therapy(HBO) has been used in an attempt to reduce the deleterious effects of radiation. But the issue of whether prior irradiation and HBO of the recipient site of a free flap affects the result of reconstruction continues to generate controversy. So, the effects of irradiation and hypergbaric oxygen therapy on microvascular anastomosis was evaluated in an experimental study in femoral vessels of rats. The experimental groups were divided into 3 groups, contorol group, irradiation group, and irradiation and HBO group. Preoperative irradiation was delivered in the left groin field with single dose corresponding 2,000cGy and total 48 hours of HBO was given 100% oxygen at 2.4 atmosphere for 4 weeks. The femoral vessels of 60 rats were anastomosed after irradiation and HBO treatment. Three days, 1 week, 2 weeks and 4 weeks after surgery, the femoral vessels were evaluated for patency and histopathologic changes. There was no notable effect of irradiation on patency of femoral vessels in rats and the radiation effects were obvious on histological examination which showed the sloughing of the endothelial cells, subintimal hyperplasia and fibrosis on the media and adventitia of femoral arteries. The histologic changes of the femoral veins were mild and not typical. But the effects of hyperbaric oxygen therapy after irradiation was seen not marked difference in irradiation group.

  • PDF

RADIOGRAPHIC INTERPRETATION OF EXPERIMENTALLY PRODUCED BONY DEFECT ACCORDING TO kVp (관전압 변화에 다른 실험적 골결손부의 방사선사진상의 판독)

  • Nam Hye Kyung;Choi Karp Shik;Kim Chin Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.2
    • /
    • pp.265-276
    • /
    • 1990
  • The purpose of this experiment was to evaluate radiographic interpretation, of various sized 60 periapical and 60 cancellous lesions in 10 mandibular sections of 5 dogs according to kVp (65, 70, 75, 80 and 85 kVp). The results were as follows; The change of kilovoltage within 65kVp-85kVp range did not have influence on the radiographic interpretation of the same-sized bony defects at the constant radiographic density (p> 0.05). When the bony defects were less than the size of No.2 round bur, radiographic interpretation of bony defects prepared with No.2 round bur was easier than those prepared with No. 1 round bur at 80-85kVp in periapical region (p<0.05). However, in cancellous bone, this radiographic interpretation was easier at 65-75kVp (p<0.05). There were significant differences in the radiographic interpretation between the defects confined only to the cancellous, bone and the defects involved in the compact bone (p<0.05). However there were no significant differences between the defects confined only to the cancellous bone and the defects involved in junctional area of cancellous and compact bone (p>0.05). From the results of densitometric analysis, there was a difference in densitometric measurements at the same radiographic interpretation scores, and aluminum equivalent differences of 0.15-1.66㎜ thickness were needed for radiographic interpretation.

  • PDF

A CLINICAL STUDY ON SKELETAL ANCHORAGE SYSTEM USING MINISCREW (구내고정원을 이용한 교정 치료중 miniscrew 탈락에 관한 연구)

  • Woo, Soon-Seop;Jeong, Soon-Tai;Huh, Young-Sung;Hwang, Kyung-Gyun;Yoo, Im-Hag;Shim, Kwang-Sup
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.2
    • /
    • pp.102-107
    • /
    • 2003
  • At orthodontic treatment, we have made every effort to get rigid anchorage which is not stirred when teeth move. As a result, the miniscrew that is rigid anchorage was invented recently, and now it is used widely. Concerning the advantage of miniscrew, it is reduced dependence of extraoral anchorage and it shortens treatment time for rapid tooth movement. In contrast, the defect of miniscrew is falling off it resulted from increasing of the mobility. So the purpose of this research is to be of help to prognose clinical use of miniscrew, which is inserted for intraoral anchorage, by investigating and comparing the failure rate of miniscrew for loading time. This study researches the failure rate of miniscrew for teeth movement at the orthodontic treatment. The failure rate of miniscrew in mid course, after inserting 147 miniscrews in 51 patients, is 13%(20/147). It showed no statistically significant differences as compared man with woman, maxilla with mandible, double-head with uni-head miniscrew, and drilling and non-drilling before inserting the miniscrew. In comparison below twenties with over twenties and the times that we give load to miniscrew, it produced that the failure rate of miniscrew is 9.7% higher in the case of below the twenties than over the twenties. Also, the failure rate of loading immediately is 10.8% higher than loading after 7 days. According to using driver for the insertion of miniscrew, the failure rate of miniscrew is higher in the case of using machined driver than in the case of using hand driver when the level of significance is 95%. According to the research, we can suppose that the failure rate has no concern with using miniscrew on man or woman, maxilla or mandible, the shape of head, and drilling or non-drilling before insertion of miniscrew. Therefore, we can choose eclectic miniscrew as demands. In addition, we must notify the patient, below twenties, to be possibility of high failure rate. And It is strongly recommended to give load after $1{\sim}2$ weeks for healing of the insertion area.

Electrial Conductivity of Oxidized Pure and Ni-Doped $SrTiO_3$ Single Crystals (산화된 $SrTiO_3$ 및 니켈도프된 $SrTiO_3$ 단결정의 전기전도도)

  • Keu Hong Kim;Jae Shi Choi
    • Journal of the Korean Chemical Society
    • /
    • v.25 no.4
    • /
    • pp.236-245
    • /
    • 1981
  • The electrical conductivities of oxidized pure and Ni-doped $SrTiO_3$ single crystals were measured as a function of the oxygen partial pressure($Po_2$) at temperature from 700 to $1200^{\circ}C$ and $Po_2$ of $10^{-8}$ to $10^{-1}$ atm. Plots of log ${\sigma}$ vs. 1/T at constant $Po_2$ were found to be linear, and the activation energies obtained from the slopes of these plots have an average value of 1.34 eV for oxidized pure and 1.06 eV for oxidized Ni-doped $SrTiO_3$ single crystals at $Po_2$'s between $10^{-8}$ to $10^{-1}$ atm. The log ${\sigma}$ vs. log $Po_2$ curves at constant temperature were found to be linear with an average slope of ${\frac{-1}{5.6}}\;{\sim}\;{\frac{-1}{6.2}}$ in the $Po_2$ ranges. From the agreement between experimental and theoretically predicted values for the electrical conductivity dependences on $Po_2$, an oxygen vacancy defect model was found applicable to oxidized pure and Ni-doped $SrTiO_3$ single crystals over the temperature range, 700~$1200^{\circ}C$. Conduction mechanisms were proposed to explain the dependences of electrical conductivity on temperature and $Po_2$.

  • PDF

CHARACTERISTICS OF ATTENTION DEFICIT OF ADHD ON COMPUTERIZED NEUROCOGNITIVE FUNCTION TESTS (전산화 신경인지기능검사를 이용한 주의력결핍/과잉운동 장애의 주의력결핍특성에 관한 연구)

  • Chung, Sun-Ju;Shin, Min-Sup;Ha, Kyoo-Seob;Hong, Kang-E
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.8 no.2
    • /
    • pp.242-255
    • /
    • 1997
  • Characteristics of attention deficit of attention-deficit hyperactivity disorder(ADHD) were investigated by administering six computerized attention tests of Vienna Test System and four neuropsychological tests to children aged 6-12, with ADHD(n=21) and age-matched normal control children(n=22). The findings indicated that ADHD children show lower level of vigilance, more decline of performance in vigilance task on time, and impaired preparedness to response. They also have selective attention deficit on monitoring tasks, but did not have sustained attention deficit compared with normal control children. On the tasks wich overload their information processing capacity, ADHD children show more impulsive response pattern than normal control children. The performance of ADHD was worse than control on the neuropsychological tests sensitive to frontal lobe dysfunction. The presense 'These' attention deficits supports the theory that the defect of ADHD is due to the dysfunction of more than one brain region, including brain stem reticular formation and frontal lobe.

  • PDF

Influence of Co-sputtered HfO2-Si Gate Dielectric in IZO-based thin Film Transistors (HfO2-Si의 조성비에 따른 HfSiOx의 IZO 기반 산화물 반도체에 대한 연구)

  • Cho, Dong Kyu;Yi, Moonsuk
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.98-103
    • /
    • 2013
  • In this work, we investigated the enhanced performance of IZO-based TFTs with $HfSiO_x$ gate insulators. Four types of $HfSiO_x$ gate insulators using different diposition powers were deposited by co-sputtering $HfO_2$ and Si target. To simplify the processing sequences, all of the layers composing of TFTs were deposited by rf-magnetron sputtering method using patterned shadow-masks without any intentional heating of substrate and subsequent thermal annealing. The four different $HfSiO_x$ structural properties were investigated x-ray diffraction(XRD), atomic force microscopy(AFM) and also analyzed the electrical characteristics. There were some noticeable differences depending on the composition of the $HfO_2$ and Si combination. The TFT based on $HfSiO_x$ gate insulator with $HfO_2$(100W)-Si(100W) showed the best results with a field effect mobility of 2.0[$cm^2/V{\cdot}s$], a threshold voltage of -0.5[V], an on/off ratio of 5.89E+05 and RMS of 0.26[nm]. This show that the composition of the $HfO_2$ and Si is an important factor in an $HfSiO_x$ insulator. In addition, the effective bonding of $HfO_2$ and Si reduced the defects in the insulator bulk and also improved the interface quality between the channel and the gate insulator.

Reliability Improvement of Cu/Low K Flip-chip Packaging Using Underfill Materials (언더필 재료를 사용하는 Cu/Low-K 플립 칩 패키지 공정에서 신뢰성 향상 연구)

  • Hong, Seok-Yoon;Jin, Se-Min;Yi, Jae-Won;Cho, Seong-Hwan;Doh, Jae-Cheon;Lee, Hai-Young
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.18 no.4
    • /
    • pp.19-25
    • /
    • 2011
  • The size reduction of the semiconductor chip and the improvement of the electrical performance have been enabled through the introduction of the Cu/Low-K process in modern electronic industries. However, Cu/Low-K has a disadvantage of the physical properties that is weaker than materials used for existing semiconductor manufacture process. It causes many problems in chip manufacturing and package processes. Especially, the delamination between the Cu layer and the low-K dielectric layer is a main defect after the temperature cycles. Since the Cu/Low-K layer is located on the top of the pad of the flip chip, the stress on the flip chip affects the Cu/Low-K layer directly. Therefore, it is needed to improve the underfill process or materials. Especially, it becomes very important to select the underfill to decrease the stress at the flip-chip and to protect the solder bump. We have solved the delamination problem in a 90 nm Cu/Low-K flip-chip package after the temperature cycle by selecting an appropriate underfill.

Numerical Analysis on the Structure Behavior of the Connected Long-span Beam during Excavation in Narrow Streets (도로 폭이 좁은 굴착공사에서 연결부가 적용되는 장지간 주형의 수치해석적 거동 평가)

  • Choi, Kwang-Sou;Ha, Sang-Bong;Lee, Hwan-Woo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.4
    • /
    • pp.263-270
    • /
    • 2020
  • This study evaluates the structural behavior of connected long-span beams applied for excavation in urban areas with a narrow street. Generally, the reliability of the connection is reduced owing to the defect of the upper flange in the connection. An improved connection part was developed to complement the defects in the connected long-span beam. A finite element analysis based on a commercial program, ABAQUS, was employed to evaluate the behavior of the improved connection part. A numerical analysis model was proposed to analyze the high-strength bolt connection and the composite behavior of steel and concrete applied to the improved connection. The suitability of the proposed numerical analysis was verified by comparing the experimental and numerical analysis results of the references. Using the proposed numerical analysis method, the improved and general connections were analyzed and compared with each other. The stress distribution and elastic-plastic behavior of the long-span beam were analyzed numerically. The analysis confirmed that 25% of the compressive stress was improved, resulting in the improvement of structural safety and performance.