• Title/Summary/Keyword: Defect

Search Result 8,180, Processing Time 0.039 seconds

Selective Oxidation of Single Crystalline AlAs layer on GaAs substrate and XPS(X-ray photoelectron spectroscopy) Analysis (GaAs 기판위에 성장된 단결정 AlAs층의 선택적 산화 및 XPS (X-ray photonelectron spectroscopy) 분석)

  • Lee, Suk-Hun;Lee, Young-Soo;Tae, Heung-Sik;Lee, Young-Hyun;Lee, Jung-Hee
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.5
    • /
    • pp.79-84
    • /
    • 1996
  • A $1\;{\mu}m$ thick n-type GaAs layer with Si doping density of $1{\times}10^{17}/cm^{3}$ and a $500{\AA}$ thick undoped single crystalline AlAs layer were subsequently grown by molecular beam epitaxy on the $n^{+}$ GaAs substrate. The AlAs/GaAs layer was oxidized in $N_{2}$ bubbled $H_{2}O$ vapor($95^{\circ}C$) ambient at $400^{\circ}C$ for 2 and 3 hours. From the result of XPS analysis, small amounts of $As_{2}O_{3}$, AlAs, and elemental As were found in the samples oxidized up to 2 hours. After 3 hours oxidation, however, various oxides related to As were dissolved and As atoms were diffused out toward the oxide surface. The as-grown AlAs/GaAs layer was selectively converted to $Al_{2}O_{3}/GaAs$ at the oxidation temperature $400^{\circ}C$ for 3 hours. The oxidation temperature and time is very critical to stop the oxidation at the AlAs/GaAs interface and to form a defect-free surface layer.

  • PDF

Anti-Ionizing Radiation Effect of Selenium on Osteoporosis Model during Bone Repair Process (골다공증 모델의 뼈 재생기에 있어 셀레늄(Selenium)의 방사선 보호작용)

  • Kim, Hyun;Cho, Sang-Rae;Choe, Changyong;Seong, Hwan-Hoo
    • Journal of Embryo Transfer
    • /
    • v.30 no.3
    • /
    • pp.201-206
    • /
    • 2015
  • Selenium (Se) is an essential trace element for humans and animals, and several findings suggest that dietary Se intake may be necessary for bone health. Accumulating evidence indicates that Se compounds possess anticancer properties. Se is specifically incorporated into proteins in the form of selenocysteine and non-specifically incorporated as selenomethionine in place of methionine. This study evaluated protection by Se in the bone repair process in ovariectomized rats after irradiation. For such purpose, 80 ovariectomized female Sprague-Dawley rats were randomly divided into 4 experimental groups: ovariectomized (Ov), Ov/Se, Ov/irradiated (Irr) and Ov/ Se/Irr. A bone defect was created on the tibia of all animals 40 days after ovariectomy. Two days after surgery, only the Ov/Se and Ov/Se/Irr rats received 0.8 mg Se/kg. Three days after surgery, only the Ov/Irr and Ov/Se/Irr rats received 10 Gy of X-rays on the lower limb region. The animals were euthanized at 7, 15, 22 and 29 days after surgery to assess the repair process, which was evaluated by analysis of trabecular bone number (Masson Trichrome) and birefringence analysis (Picrosirius). It was possible to observe a delay in the bone repair process in the ovariectomized/irradiated group and similarity between the ovariectomized, Ov/ Se and Ov/Se/Irr groups. Our findings suggest that sodium selenite may influence a radioprotective effect in the bone repair of tibia of ovariectomized rats without toxicity.

Study on the Change of Absorbed Dose and Image Quality according to X-ray Condition of Detector in Digital Radiography(DR) (Digital Radiography(DR)에서 검출기의 X선 조건에 따른 흡수선량 및 영상화질 변화에 관한 연구)

  • Hwang, Jun-Ho;Jeong, Jae-Ho;Kim, Hyun-Soo;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.9
    • /
    • pp.99-106
    • /
    • 2017
  • This study focused on the issue that when a diagnostic detector is found to have a defect, a patient would be exposed to radiation and image quality would be degraded. Though dose analysis, an experiment was conducted to evaluate detector performance as Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR). Absorbed dose, SNR and CNR were measured using a dosimeter and a tissue equivalent phantom. The experiment was conducted to compare whether the dose value shown after being attached to the back side of the phantom matches the dose value attached behind the detector, where in the conditions of skull, chest and abdomen were set at 75 kVp, 25 mAs, 110 kVp, 8 mAs, and 80 kVp, 20 mAs, respectively. As a result, there was a difference in that the dose values attached to the back side of the detector were 0.004 mGy, 0.006 mGy, 0.003 mGy, whereas those of the back side of the phantom were 0.006 mGy, 0.016 mGy, 0.017 mGy. In order to match both values, the condition was increased and SNR and CNR also increased from 88.32, 88.10, 4.09, 1.63, 87.94, 79.97 to 93.87, 93.75, 4.91, 4.03, 92.02, 84.92. Though this study, we found that when a detector is found to have a aging, it shortens the life of equipment and increases the dose of a patient, also the improvement effect of image quality is inadequate.

A study on Fire Case and Countermeasure of Tourist Hotel (관광호텔의 화재손해 위험관리방안 - 화재발생현황과 대형화재사례 분석 중심)

  • Han, Sukman;Son, Jung Hyoun;Kim, Jong Won
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.4
    • /
    • pp.362-375
    • /
    • 2012
  • Tourist hotels are equipped with facilities such as accommodation and restaurants, exercise, recreation. Unspecified guests, visitors and management of tourist hotels are very vulnerable on the casualties and property losses due to fire peril exist. In this study, we analysis that the fire statistics status of tourist hotels from 2001 to 2010. And the 15 cases of a large hotel fire are reviewed. The total number of fires on hotel are consist of a hotel rooms fire(33.2%), a restaurant kitchen fire(11.8%). And the major causes of the fire are an electrical fire (40.8%), a cigarette fire (14.5%) and a hot-work fire (9.2%). In case study, the fire wall defect and combustible materials are major fire loss causes for 10year. Each tourist hotels are needed a development of suitable fire risk management and a field operations. A hotel is required an active fire risk management on a preventive inspection, an education and training, and a preventive maintenance. It is necessary that a fire wall maintenance to prevent of the spread of a fire and a sprinkler installation of whole area to protect fire. And it is very important an emergency response for evacuation of guest, and operate emergency procedures on a fire or emergency situation.

A Fast-Loaming Algorithm for MLP in Pattern Recognition (패턴인식의 MLP 고속학습 알고리즘)

  • Lee, Tae-Seung;Choi, Ho-Jin
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.8 no.3
    • /
    • pp.344-355
    • /
    • 2002
  • Having a variety of good characteristics against other pattern recognition techniques, Multilayer Perceptron (MLP) has been used in wide applications. But, it is known that Error Backpropagation (EBP) algorithm which MLP uses in learning has a defect that requires relatively long leaning time. Because learning data in pattern recognition contain abundant redundancies, in order to increase learning speed it is very effective to use online-based teaming methods, which update parameters of MLP pattern by pattern. Typical online EBP algorithm applies fixed learning rate for each update of parameters. Though a large amount of speedup with online EBP can be obtained by choosing an appropriate fixed rate, fixing the rate leads to the problem that the algorithm cannot respond effectively to different leaning phases as the phases change and the learning pattern areas vary. To solve this problem, this paper defines learning as three phases and proposes a Instant Learning by Varying Rate and Skipping (ILVRS) method to reflect only necessary patterns when learning phases change. The basic concept of ILVRS is as follows. To discriminate and use necessary patterns which change as learning proceeds, (1) ILVRS uses a variable learning rate which is an error calculated from each pattern and is suppressed within a proper range, and (2) ILVRS bypasses unnecessary patterns in loaming phases. In this paper, an experimentation is conducted for speaker verification as an application of pattern recognition, and the results are presented to verify the performance of ILVRS.

A Study on vibration suppression of dual inertia system using controlling Parameter $\alpha$ of PID controller with 2-degree of freedom (2자유도 PID 제어기의 파라미터 $\alpha$ 추종을 이용한 2관성 시스템의 진동억제)

  • 박재현;추연규;김현덕;박연식
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.506-510
    • /
    • 2004
  • A torque transmission system composed of several gears and couplings is flexible. In order to get an exact response of motor, the torsional vibration due to an unexpected change of motor speed must be suppressed. Therefore, it is very important that motor control suppress vibration. Various methods to control it including dual inertia system are proposed. Specially, the method of vibration suppression is that vibration can be suppressed to fee㏈ack the estimated torsion torque via the disturbance observer filter being of normal filter. The suitable Proportional controller and coefficient parameter can be designed using CDM and the torsional vibration also be suppressed, but it has a low degree of adaptability to disturbance. The PID controller can be designed easily, but makes the excessive overshoot and oscillation for system response in the early period. To resolve these problems, simple and practical PID controller with two degree of freedom is proposed recently that it ran improve performance of obeying the reference unconcerned in any disturbance by changing the proportional gain by two degree of freedom parameter. But it has also the defect that parameter a must be changed to obtain the ideal Proportional parameter. On this paper, we design the controller which automatically adjusts parameter u using fuzzy Algorithm to overcome such defects. Also, we compare the proposed method with established one and evaluate them to confirm performance of the designed controller.

  • PDF

A System for Change Management of Sensor Network Applications based on Version Synchronization (버전동기화 기반의 센서 네트워크 응용 소프트웨어 변경 관리 시스템의 구축 사례)

  • Kim, Jae-Cheol;Kim, Ju-Il;Chong, Ki-Won;Lee, Woo-Jin
    • The KIPS Transactions:PartA
    • /
    • v.16A no.2
    • /
    • pp.125-134
    • /
    • 2009
  • This paper proposes a change management system of sensor network applications based on version synchronization that supports to effectively manage defect correction of applications, change of functions for applications or improvement of applications without suspending the sensor network. The proposed change management system consists of the NADE which is an application development environment, the Node Management Server, and the Node Agent. NADE is an Eclipse-based development environment for developing applications which are installed into nodes. NADE is also connected with CVSNT which is a version management tool and performs application version management using the CVSNT. Node Management Server manages nodes to maintain latest versions of applications by synchronizing versions of applications which are performed on the nodes with the versions of applications which are developed in the NADE. Node Agent which is loaded into the node periodically sends the version information of the application to the server, and stores and updates the version information of the application. Through the proposed change management system, applications of nodes are automatically updated when versions of applications are changed by correcting defects, changing functions or improving applications. Therefore, the user can effectively manage the execution of sensor network system without suspending or delaying the sensor network. Also, visibility of change management for sensor network applications will be improved.

Edge-Enhanced Error Diffusion Halftoning using Local mean and Spatial Activity (국부 평균과 공간 활성도를 이용한 에지 강조 오차확산법)

  • Kwak Nae-Joung;Kwon Dong-Jin;Kim Young-Gil;Ahn Jae-Hyeong
    • The KIPS Transactions:PartB
    • /
    • v.13B no.2 s.105
    • /
    • pp.77-82
    • /
    • 2006
  • Digital halftoning is the technique to obtain a bilevel-toned image from continuous-toned image. Among halftoning methods, the error diffusion method gives better subjective quality than other halftoning ones. But it also makes edges of objects blurred. To overcome the defect, we proposes the modified error diffusion to enhance the edges using the property that human vision perceives the local average luminance and doesn't perceive a little variation of the spatial variation. The proposed method computes a spatialactivity, which is the difference between a pixel luminance and the average of its $3{\times}3$ neighborhood pixels' Iuminance weighted according to the spatial positioning. The system also usesof edge enhancement (IEE), which is computed from the normalized spatial activitymultiplied by the average luminance. The IEE is added to the quantizer's input pixel and feeds into the halftoning quantizer. The quantizer produces the halftone image having the enhanced edge. The computer experimental results show that the proposed method produces clearer bilevel-toned images than conventional methodsand the edge of objects is preserved well. Also the performance of the preposed method is improved, compared with that of the conventional method by measuring the edge correlation and the local average accordance at some ranges of viewing distance.

Suggestions for Safety Improvement of CNG Bus Based on Accident and Failure Analysis (CNG버스 사고원인 분석에 근거한 안전성 향상 방안에 대한 연구)

  • Yoon, Jae-Kun;Yoon, Kee-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.69-76
    • /
    • 2008
  • Three failure cases of CNG composite vessels were reported since after January 2005. The 1st and 2nd accidents were indebted to vessel defect and installation mistake. The 3rd was caused by gas leak at pipe connections. In this paper various aspects were studied based on information of the three failure analysis, which must be improved for better safety of the CNG bus system. Overpressure region caused by vessel explosion was theoretically predicted and also assessed by PHAST program. Explosion of 120 l vessel under 20 MPa is equivalent to 1.2 kg TNT explosion. The predicted value by PHAST was more serious than theoretical one. However, actual consequence of explosion was much less than both of the predicted consequences. Since the CNG vessel was designed by the performance based design methodology, it is difficult to verify whether the required process and tests were properly conducted or not after production. If material toughness is not enough, the vessel should be weak in brittle fracture at early in the morning of winter season since the metal temperature can be lower than the transition temperature. If autofrettage pressure is not correct, fatigue failure due to tensile stress during repeated charging is possible. One positive aspect is that fire did not ocurred after vessel failure. This may be indebted to fast diffusion of natural gas which hindered starting fire.

  • PDF

Non-Destructive Testing of Damaged Thermoplastic Pipes Electrofusion Joints Using Phased Array Ultrasonic (위상배열초음파를 이용한 손상된 열가소성 플라스틱배관 전기융착부 비파괴검사)

  • Kil, Seong-Hee;Kim, Byung-Duk;Kwon, Jeong-Rock;Yoon, Kee-Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.5
    • /
    • pp.64-68
    • /
    • 2013
  • Non destructive testing(NDT) methods of electrofusion(EF) joints of thermoplastics pipes are required for fusion joint safety and for the long term reliability of a pipe system. Electrofusion joints, which are joined at the proper fusion process and procedures, may encounter defects due to the difference of ovality between pipes and coupling, improper fusion process or porosity result from electrofusion joining. These defects can cause the failure of pipeline and by extension, they can be caused the limit to expand the use of plastics pipes. This paper studies inspection results using ultrasonic imaging method for damaged polyethylene electrofusion joints. Gas was leaking from 250mm diameter polyethylene electrofusion joints at February 2004 which was electrofused at December 1994 and operation pressure was 2.45kPa. First, surface inspection was conducted and then in order to find the types of defects examination using ultrasonic imaging method was performed. Lack of fusion and inappropriate inserting for polyethylene pipes into electrofusion coupling were found and causes of the gas leak were judged that misalignment and insert defect. Cutting inspection was performed and each inspection results were compared to. Results of ultrasonic imaging method and cutting inspection were the same.