• Title/Summary/Keyword: Dect

Search Result 34, Processing Time 0.025 seconds

Classification of Urinary Stone into Uric Acid & Non-uric Acid by Dual-Energy (이중에너지 전산화단층촬영을 이용한 요로결석의 성분 분석에 관한 연구)

  • Myung-Jin Jung;Sung-Gil Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.835-841
    • /
    • 2023
  • The aim of this study is to evaluate the diagnostic ability of dual-energy computed tomography (DECT) for Composition determination of urinary stones in phantom model. Seventeen cases with urinary stones who underwent DECT were enrolled in the study. The composition of the urinary stones was extracted from the seventeen patients were analyzed with DECT in phantom model with fresh pork. The volume scan method using Dual-energy software was used and the scanned image sets were assessed. All 17 urinary stones of the phantom model were analyzed according to the stone composition using DE stone Analysis were divided into uric acid stones (n=6, 35.29%) and non-uric acid stones (n=11, 64.71%). These urinary stones were pathologically confirmed. The mean attenuation values of uric acid stones at 135 kV, 100 kV and 80 kV was 348.87 ± 166.37 HU, 345.33 ± 151.18 HU and 337.94 ± 172.77 HU, respectively. The mean attenuation values of non-uric acid stones at 135 kV, 100 kV and 80 kV was 551.93 ± 297.09 HU, 747.04 ± 351.31 HU and 958.19 ± 424.72 HU, respectively. At 80 kV, uric acid stones and non-uric acid stones showed significant difference in the attenuation values(P<0.05). The attenuation values of DECT could differentiate the compositions of urinary stones between uric acid and non-uric acid stones at 80 kV in phantom model.

Comparison of Estimated and Measured Doses of Dual-energy Computed Tomography (Dual-energy 컴퓨터단층촬영에서 장비 제공선량과 측정선량 비교)

  • Kim, Yung-Kyoon;Kim, Yon-Min
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.405-411
    • /
    • 2018
  • We will provide basic data on the evaluation of patient dose in terms of DECT quality control by comparing the equipment-provided dose with the measured dose according to the configuration method of the X-ray generator by the manufacturer of the dual-energy CT unit. For computed tomography (CT) equipment, Discovery 750HD, Aquilion ONE GENESIS Edition, and Somatom Definition Flash were used. The $CTDI_{vol}$ value was measured by inserting the Unfors Xi ion chamber into a 32 cm PMMA acryl Phantom. The results of estimated $CTDI_{vol}$ DECT and measured $CTDI_{vol}$ showed that the dose difference between DECT 80 + 140 kVp of G company was at least 0.51% and -1.90% max, and measured $CTDI_{vol}$ was slightly lower (p<0.05). The difference of 80 + 140 kVp of S company was the minimum of 5.84% and the maximum of 7.52% (p<0.05). The measured $CTDI_{vol}$ was less than estimated $CTDI_{vol}$. The C company's 80 + 135 kVp showed a difference of at least 7.58% and a maximum of 13.58% (P<0.05), and all of measured $CTDI_{vol}$ was less. The linearity of exposure dose for all DECT equipment was very linearly reflected with $R^2$ being 0.97 or above, and the measured dose of the ionization chamber was less than the predicted dose of the monitor.

Analysis of Attenuation Differences According to Radiolucent and Radiopague Materials : Based on DECT (Dual Energy Computed Tomography) (방사선 투과 및 불투과성 물질에 따른 감약 차이의 분석 : DECT 검사 중심으로)

  • Jang, Hyon-Chol;Kim, Yoon-Shin;Kim, Hyeon-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1584-1589
    • /
    • 2014
  • This study analyzed CT values of radiolucent and radiopaque materials by energy region after selecting radiolucent and radiopaque materials at random using GE's DECT((Dual Energy Com-puted Tomography) at S University Hospital located in Gyeonggi-province from July through August in 2013. Besides, it drew out the most analogous energy region to the value of 120kVp CT, which is applied to existing SECT(Single Energy Computed Tomography), by utilizing the analysis method of CT values and tried to find out the most useful and appropriate materials when contrast was applied within visible area in clinical application. As a result, there was little decrease of CT value after 90KeV in the case of materials with low density and high moisture content such as normal saline, methyl-cellulose and gels used in ultra-sonic waves test; energy does not influence much on materials with extremely low or high density such as air and contrast medium; methyl-cellulose and gels used in ultra-sonic waves test are considered to be the most useful materials for clinical applications.

Effect of Total Collimation Width on Relative Electron Density, Effective Atomic Number, and Stopping Power Ratio Acquired by Dual-Layer Dual-Energy Computed Tomography

  • Jung, Seongmoon;Kim, Bitbyeol;Yoon, Euntaek;Kim, Jung-in;Park, Jong Min;Choi, Chang Heon
    • Progress in Medical Physics
    • /
    • v.32 no.4
    • /
    • pp.165-171
    • /
    • 2021
  • Purpose: This study aimed to evaluate the effect of collimator width on effective atomic number (EAN), relative electron density (RED), and stopping power ratio (SPR) measured by dual-layer dual-energy computed tomography (DL-DECT). Methods: CIRS electron density calibration phantoms with two different arrangements of material plugs were scanned by DL-DECT with two different collimator widths. The first phantom included two dense bone plugs, while the second excluded dense bone plugs. The collimator widths selected were 64 mm×0.625 mm for wider collimators and 16 mm×0.625 mm for narrow collimators. The scanning parameters were 120 kVp, 0.33 second gantry rotation, 3 mm slice thickness, B reconstruction filter, and spectral level 4. An image analysis portal system provided by a computed tomography (CT) manufacturer was used to derive the EAN and RED of the phantoms from the combination of low energy and high energy CT images. The EAN and RED were compared between the images scanned using the two different collimation widths. Results: The CT images with the wider collimation width generated more severe artifacts, particularly with high-density material (i.e., dense bone). RED and EAN for tissues (excluding lung and bones) with the wider collimation width showed significant relative differences compared to the theoretical value (4.5% for RED and 20.6% for EAN), while those with the narrow collimation width were closer to the theoretical value of each material (2.2% for EAN and 2.3% for RED). Scanning with narrow collimation width increased the accuracy of SPR estimation even with high-density bone plugs in the phantom. Conclusions: The effect of CT collimation width on EAN, RED, and SPR measured by DL-DECT was evaluated. In order to improve the accuracy of the measured EAN, RED, and SPR by DL-DECT, CT scanning should be performed using narrow collimation widths.

Analysis of 1.7GHz Frequency Interference for Domestic Digital Cordless Phone (1.7GHz 대역 국내 디지털 코드리스폰 도입을 위한 주파수 간섭 분석)

  • Kim, Jong-Ho;Kang, Gun-Hwan;Park, Duk-Kyu
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.3
    • /
    • pp.60-67
    • /
    • 2007
  • This research studies and analyzes the current trends and the frequency allocation bands for digital cordless phone(DCP) in other country. From these results, we propose 1.7GHz & 2.4GHz as a effective candidate frequency band for domestic DCP. A proposed 1.7GHz is expected to introduce DECT system of Europe. Therefore it is necessary to make an analysis of interference between 1.7GHz band and an adjacent IMT-2000 band. In this paper, we proposed the allocation of channel for 1.7GHz on the basis of the analysis of frequency interference between 1.7GHz band and an adjacent IMT-2000 band.

A Real-Time Implementation of 4 Channel ADPCM CODEC & Echo Canceller for DECT Base Station (DECT기지국용 4채널 ADPCM 코덱과 반향제거기의 실시간 구현)

  • 연규철;한철희;박연춘;안재선;윤대희
    • Proceedings of the IEEK Conference
    • /
    • 2001.09a
    • /
    • pp.517-520
    • /
    • 2001
  • 본 논문에서는 DRCT 기지국에서 사용하기 위한 4채널 음성 코덱과 반향제거기를 TMS320VC5402 DSP 칩을 이용하여 실시간 구현하였다. 코드 최적화를 통하여 4채널 G.726 ADPCM 코덱과 반향제거기를 76MIPS의 연산량 이내로 실시간 동작 가능하도록 구현하였다. 본 논문에서 구현한 ADPCM 코덱은 ITU-T G.726 Appendix II에서 정의된 모든 테스트 샘플로 검증하였다. 반향제거기는 모의실험 결과 반향신호를 약 20dB 정도 감쇠시켰으며, 실시간 시스템 통화시험을 통해 전체시스템의 안정적인 동작을 확인하였다.

  • PDF

Optimization of Energy Modulation Filter for Dual Energy CBCT Using Geant4 Monte-Carlo Simulation

  • Ju, Eun Bin;Ahn, So Hyun;Choi, Sang Gyu;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.125-130
    • /
    • 2016
  • Dual energy computed tomography (DECT) is used to classify two materials and quantify the mass density of each material in the human body. An energy modulation filter based DECT could acquire two images, which are generated by the low- and high-energy photon spectra, in one scan, with one tube and detector. In the case of DECT using the energy modulation filter, the filter should perform the optimization process for the type of materials and thicknesses for generating two photon spectra. In this study, Geant4 Monte-Carlo simulation toolkit was used to execute the optimization process for determining the property of the energy modulation filter. In the process, various materials used for the energy modulation filter are copper (Cu, $8.96g/cm^3$), niobium (Nb, $8.57g/cm^3$), stannum (Sn, $7.31g/cm^3$), gold (Au, $19.32g/cm^3$), and lead (Pb, $11.34g/cm^3$). The thickness of the modulation filter varied from 0.1 mm to 1.0 mm. To evaluate the overlap region of the low- and high-energy spectrum, Geant4 Monte-Carlo simulation is used. The variation of the photon flux and the mean energy of photon spectrum that passes through the energy modulation filter are evaluated. In the primary photon spectrum of 80 kVp, the optimal modulation filter is a 0.1 mm lead filter that can acquire the same mean energy of 140 kVp photon spectrum. The lead filter of 0.1 mm based dual energy CBCT is required to increase the tube current 4.37 times than the original tube current owing to the 77.1% attenuation in the filter.