• Title/Summary/Keyword: Decrement Ratio

Search Result 126, Processing Time 0.029 seconds

Discharge Patterns of Yongnup, Daeam-san (대암산 용늪의 유출 패턴에 관한 연구)

  • ZHU, Ju-Hua;PARK, Jongkwan
    • Journal of The Geomorphological Association of Korea
    • /
    • v.18 no.4
    • /
    • pp.271-282
    • /
    • 2011
  • The purpose of this study is to clarify the discharge patterns of Yongnup, Daeam-san. Many hydrographs were analyzed by the types of rising and falling stages, and the slope of those stages with the semi-log graph paper was a key point to distinguish the discharge patterns during rainstorms. The correlation between rainfall intensity and slopes of the second or third rising stage was higher than that between slopes of the first rising stage and rainfall intensity. Also, the coefficient of correlation between discharge decrement and the lapsed time from the peak to inflection point of hydrograph, during high water stages, was better than that during low water stages. The annual average discharge rate of Yongnup was 0.54 and the average direct runoff ratio was 0.14. The total discharge amount from Yongnup was about 410,000 tons for a water year, the monthly maximum amount emerged in September and the minimum amount was occurred in March. In summer, 37.7% was a seasonal maximum runoff ratio; on the other hand, 9.4% was a seasonal minimum runoff ratio in winter.

Impact of face masks on spectral and cepstral measures of speech: A case study of two Korean voice actors (한국어 스펙트럼과 캡스트럼 측정시 안면마스크의 영향: 남녀 성우 2인 사례 연구)

  • Wonyoung Yang;Miji Kwon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.4
    • /
    • pp.422-435
    • /
    • 2024
  • This study intended to verify the effects of face masks on the Korean language in terms of acoustic, aerodynamic, and formant parameters. We chose all types of face masks available in Korea based on filter performance and folding type. Two professional voice actors (a male and a female) with more than 20 years of experience who are native Koreans and speak standard Korean participated in this study as speakers of voice data. Face masks attenuated the high-frequency range, resulting in decreased Vowel Space Area (VSA) and Vowel Articulation Index (VAI)scores and an increased Low-to-High spectral ratio (L/H ratio) in all voice samples. This can result in lower speech intelligibility. However, the degree of increment and decrement was based on the voice characteristics. For female speakers, the Speech Level (SL) and Cepstral Peak Prominence (CPP) increased with increasing face mask thickness. In this study, the presence or filter performance of a face mask was found to affect speech acoustic parameters according to the speech characteristics. Face masks provoked vocal effort when the vocal intensity was not sufficiently strong, or the environment had less reverberance. Further research needs to be conducted on the vocal efforts induced by face masks to overcome acoustic modifications when wearing masks.

Teratological Evaluation of Azinphos-Methyl in Rat Fetuses (Azinphos-methyl이 랫트 태아에 미치는 기형학적 연구)

  • Cho, Myung-Haing;Lee, Chang-Eop;Lee, Yong-Soon
    • Toxicological Research
    • /
    • v.4 no.1
    • /
    • pp.55-84
    • /
    • 1988
  • This study was carried out to investigate the teratological potential of azinphos-methyl in the rat fetuses and to establish the nature of the effects on organogenesis and intrauterine development. The Sprague-Dawley female rats (180-210g) without previous litter were used in this study. Azinphos-methyl dosages of 0.094mg/kg, 0.4mg/kg, 1.5mg/kg were selected based on the acute intragastric $LD_{50}$ of 15mg/kg in the rat. Azinphos-methyl in water (Treatment Group), non-treatment control (Negative Control), water control (Sham Control), were administered by oral route and aqueous solution of acetyl salicylic acid (Positive Control) was administered by gavage at rate of 10 ml/kg of body weight from day 6 through 15. The results obtained were summarized as follows. 1. Decreased body weight of dams was observed in animals treated with aspirin and azinphos-methyl 1.5 mg/kg from day 7 through 14. (P<0.01) 2. There was an apparent decrement in the absolute liver weight in the azinphos-methyl 1.5 mg/kg treated group (P<0.05). However, the absolute and relative kidney weight in aspirin group (P<0.05, P<0.01) and the absolute and relative ovary weight in aspirin, azinphos-methyl treatment groups (P<0.01, P<0.05) were increased. 3. Decreased protein contents of dam's liver was observed in the aspirin and high dose azinphos-methyl treated group of animals (P<0.01). 4. The number of male-female ratio per dam increased in azinphos-methyl 1.5 mg/kg group but there was an apparent decrement in the body weight of fetuses in aspirin and high dose azinphos-methyl group (P<0.01, P<0.05). Total immature and resorbed fetuses were increased in aspirin group and the number of dead fetuses were also increased in azinphos-methyl 1.5mg/kg treated group of animals. (P<0.01, P<0.05). 5. In soft tissue defects, diaphragmatic hernia in diaphragm, anophthalmia, enlarged olfactory bulb, hydrocephalus, absence of third and lateral ventricle in skull, hydronephrosis in kidney, atrophy of left ventricle wall, enlarged apex in heart were observed. Especially, defects of diaphragm, heart and eye ball showed peak incidences in the high dose azinphosmethyl and aspirin group. (P<0.01). 6. Variations in the ossification patterns of skull, sternebrae, tail, forelimbs and hindlimbs showed peak incidences in the aspirin and high dose azinphos-methyl group. (P<0.01). 7. In the developmental indices of offspring, the mortality of aspirin and azinphos-methyl 1.5mg/kg treated group was higher than that of negative control. And, there was an apparent decrement in the body weight of fetuses (P<0.01) and considerable differences were obtained in pivoting, development of fur, auditory function, vision, quadrupled muscle development and testes descent in aspirin and azinphos-methyl 1.5mg/kg group. (P<0.01).

  • PDF

Risk Factors of Allogenous Bone Graft Collapse in Two-Level Anterior Cervical Discectomy and Fusion

  • Woo, Joon-Bum;Son, Dong-Wuk;Lee, Su-Hun;Lee, Jun-Seok;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.450-457
    • /
    • 2019
  • Objective : Anterior cervical discectomy and fusion (ACDF) is commonly used surgical procedure for cervical degenerative disease. Among the various intervertebral spacers, the use of allografts is increasing due to its advantages such as no harvest site complications and low rate of subsidence. Although subsidence is a rare complication, graft collapse is often observed in the follow-up period. Graft collapse is defined as a significant graft height loss without subsidence, which can lead to clinical deterioration due to foraminal re-stenosis or segmental kyphosis. However, studies about the collapse of allografts are very limited. In this study, we evaluated risk factors associated with graft collapse. Methods : We retrospectively reviewed 33 patients who underwent two level ACDF with anterior plating using allogenous bone graft from January 2013 to June 2017. Various factors related to cervical sagittal alignment were measured preoperatively (PRE), postoperatively (POST), and last follow-up. The collapse was defined as the ratio of decrement from POST disc height to follow-up disc height. We also defined significant collapses as disc heights that were decreased by 30% or more after surgery. The intraoperative distraction was defined as the ratio of increment from PRE disc height to POST disc height. Results : The subsidence rate was 4.5% and graft collapse rate was 28.8%. The pseudarthrosis rate was 16.7% and there was no association between pseudarthrosis and graft collapse. Among the collapse-related risk factors, pre-operative segmental angle (p=0.047) and intra-operative distraction (p=0.003) were significantly related to allograft collapse. The cut-off value of intraoperative distraction ${\geq}37.3%$ was significantly associated with collapse (p=0.009; odds ratio, 4.622; 95% confidence interval, 1.470-14.531). The average time of events were as follows: collapse, $5.8{\pm}5.7months$; subsidence, $0.99{\pm}0.50months$; and instrument failure, $9.13{\pm}0.50months$. Conclusion : We experienced a higher frequency rate of collapse than subsidence in ACDF using an allograft. Of the various preoperative factors, intra-operative distraction was the most predictable factor of the allograft collapse. This was especially true when the intraoperative distraction was more than 37%, in which case the occurrence of graft collapse increased 4.6 times. We also found that instrument failure occurs only after the allograft collapse.

The Effect of Salt and Organic Solvents on the Interaction of Thionin-Sodium Dodecyl Sulfate System (Thionin-Sodium Dodecyl Sulfate계의 상호작용에 있어서 염 및 유기용매의 첨가효과에 관한 연구)

  • Kim, Sung-Hyun;Song, Ki-Dong
    • Applied Chemistry for Engineering
    • /
    • v.5 no.5
    • /
    • pp.779-785
    • /
    • 1994
  • The interaction between the cationic dye, thionin(Th) and the anionic surfactant, sodium dodecyl sulfate (SDS) has been investigated by absorption spectra. As the temperature of surfactant solution was increased in premicellar range(S/D=10, 80, and 160) which was much lower than the critical micelle concentration(CMC), the increment or decrement of the molar extinction coeffecient ratio appeared. It was found that the most stable temperature range of the oligomer aggregate in Th-SDS system at S/D=160 was below $60^{\circ}C$. With increasing the concentration of inorganic salt and organic solvents in Th-SDS system, ${\alpha}$-band was increased, but ${\gamma}$=band or J-band was decreased. The orders of ${\alpha}$-band increasing power were $Cl^-$>$ClO{_4}{^-}$>$SO{_4}{^{2-}}$>$NO{_3}{^-}$ and 2-propanol>ethanol>methanol>ethylene glycol.

  • PDF

Assessment of the Wear Comfort of Outdoorwear by ECG and EEG Analyses (아웃도어웨어의 착용 쾌적성 평가를 위한 심전도 및 뇌파 분석)

  • Jeong, Jeong-Rim;Kim, Hee-Eun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.10
    • /
    • pp.1665-1672
    • /
    • 2009
  • This study examines the comfort of outdoorwear by electrocardiogram (ECG) and electroencephalogram (EEG) analyses. An experiment that consisted of rest (30 min), exercise (30 min), and recovery (20 min) periods was administered in a climate chamber with 10 healthy male participants. Two kinds of outdoorwear made of 100% cotton fabrics ('Control') and specially engineered fabrics having the feature of quick sweat absorbency and high speed drying fabric ('Functional') are evaluated in the experiment. ECG and EEG signals were obtained during the rest and recovery periods for the two outdoorwear conditions. The ECG analysis identified a smaller decrement of high frequency (HF) power for the 'Functional' when compared with the 'Control' during the recovery period. Next, the EEG analysis showed that the relative band powers of slow $\alpha$ and mid $\alpha$ increased for the 'Functional' while they decreased for the 'Control' and that the ratio of $\alpha$ power to high $\beta$ power was higher for the 'Functional'. The evaluation results indicate that the participants could remain relaxed more with less stress while wearing the functional outdoorwear that demonstrated the positive effects on autonomic nervous system (ANS) activities. The present study is significant in regard that use of ECG and EEG for the assessment of wear comfort is the first in the field of clothing and textile.

The Effect of PWHT on Fracture Toughness in HAZ of Cr-Mo Steel(II) (Cr-Mo鋼 熔接熱影響部 의 破壞靭性 에 미치는 熔接後 熱處理 의 影響 II)

  • 임재규;정세희
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.1
    • /
    • pp.40-46
    • /
    • 1985
  • Some problems such as toughness decrement and stess relief cracking (SRC), many occur when post weld heat treatment (PWHT) is applied to remove residual stress adn hydrogen. In this paper PWHT was carried out under the stress of 0, 98, 196 and 294 MPa (0, 10, 20 and 30kgf/mm$^{2}$ each) to simulate residual stress in HAZ of Cr-Mo steel. The effect of applied stress during PWHT on fracture toughness was evaluated by COD fracture toughness test, micro-hardnes test and observation of SEM. The experimental results are as follows; (1) Fracture toughness of weld HAZ was improved by PWHT, but it decreased as heat treated under the stress. (2)Hardness ratio under the stress of 294MPa (30kg/mm$^{2}$) was lower and fracture toughness was decreased than that of the no stress. (3) Applied stress in weld HAZ during PWHT assisted precipitation of over saturated alloying elements in the structure, so fracture surface at the stress of 294MPa (30kg/mm$_{2}$) appeared the grain boundary failure possibly one of the reasons for PWHT embrittlenment.

The numerical analysis of performance of OTEC system with vapor-vapor ejector (증기-증기 이젝터를 적용한 OTEC 시스템 성능의 수치적 분석)

  • Yoon, Jung-In;Son, Chang-Hyo;Ye, Byung-Hyo;Ha, Soo Jeong;Choi, In-Soo;Lee, Ho-Saeng;Kim, Hyeon-Ju
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.45-50
    • /
    • 2014
  • In this paper, the Ocean Thermal Energy Conversion(OTEC) with vapor-vapor ejector is proposed newly. At this OTEC system, a vapor-vapor ejector is installed at inlet of condenser. The vapor-vapor ejector plays a very important role in increasing of the production work of low-stage turbine throughout the decrement of outlet pressure of ejector. The performance analysis is conducted for optimizing the system with HYSYS program. The procedure of performance analysis consists of outlet pressure of high turbine, the mass ratio of working fluid at separator, total working fluid rate, and nozzle diameters of vapor-vapor ejector. The main results is summarized as follows. The nozzle diameter is most important thing in this study. When each nozzle diameter of vapor-vapor ejector is 10 mm, the efficiency of OTEC system with vapor-vapor ejector shows the highest value. So it is necessary to set the optimized nozzle diameters of vapor-vapor ejector for achieving the high efficiency OTEC power system.

The Effect of Electrical Stimulation of Body Composition in Obese Person (전기자극이 체성분에 미치는 효과)

  • Kim, Yong-Seong;Bang, Sang-Bun
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.2 no.3
    • /
    • pp.13-24
    • /
    • 2004
  • The purpose of this study is to reveal the effect of electrical stimulation of body composition in obese person. Subjects were 30s to 40s aged healthy workers(2004. 3. 8~4. 17) in the S general Hospital in Suwon and they were brought to manage obesity. Subjects were divided into control group(Female<0.85, Male<0.90) and study group(Female>0.85, Male>0.90) by WHR(waist-hip ratio) that is measured by Automatic body composition analyzer(InBody 3.0). And we divided the study group with randomized methods into group A(n=8) and group B(n=8). Then we compared and analyzed the change of muscle mass, body fat, abdominal girth, WHR, BMI(body mass index) after application of electrical stimulation, three times a week, for 30 minutes in each session with 50 Hz of pulse frequency, $20\;{\mu}s$ or $250\;{\mu}s$ of pulse duration. There was statistically meaningful decrement of body fat(p<0.05) and abdominal girth(p<0.05) but not of body weight, muscle mass, WHR and BMI in the control group after application of electrical stimulation with 50 Hz, $20\;{\mu}s$. There were meaningful change of abdominal girth(p<0.05), WHR(p<0.05) and BMI(p<0.05), but not of body weight, muscle mass and body fat after application of electrical stimulation with 50 Hz, $20\;{\mu}s$ in group A. We applied electrical stimulation with 50 Hz, $250\;{\mu}s$ in group B, then there were meaningful change of body weight(p<0.05), body fat(p<0.01), abdominal girth(p<0.01), WHR(p<0.05) and BMI(p<0.01) but not of muscle mass only. Consequently, the pulse duration is the main parameter of electrical stimulation that affect the body composition of obese person in this study and if we combined the diet control to reduce blood components we could have better result. So it would be more effective to manage localized obesity(in abdomen, thigh, upper arm, etc.) if you apply electrical stimulation considering the pulse duration.

  • PDF

Rotordynamic Performance Analysis and Operation Test of a Power Turbine for the Super critical CO2 Cycle Application (초임계 CO2 발전용 파워 터빈의 회전체 동역학 해석 및 구동 시험)

  • Lee, Donghyun;Kim, Byungok;Sun, Kyungho;Lim, Hyungsoo
    • Tribology and Lubricants
    • /
    • v.33 no.1
    • /
    • pp.9-14
    • /
    • 2017
  • This paper presents a rotordynamic analysis and the operation of a power turbine applied to a 250 kW super-critical $CO_2$ cycle. The power turbine consists of a turbine wheel and a shaft supported by two fluid film bearings. We use a tilting pad bearing for the power turbine owing to the high speed operation, and employ copper backing pads to improve the thermal management of the bearing. We conduct a rotordynamic analysis based on the design parameters of the power turbine. The dynamic coefficients of the tilting pad bearings were calculated based on the iso-thermal lubrication theory and turbine wheel was modeled as equivalent inertia. The predicted Cambell diagram showed that there are two critical speeds, namely the conical and bending critical speeds under the rated speed. However, the unbalance response prediction showed that vibration levels are controlled within 10 mm for all speed ranges owing to the high damping ratio of the modes. Additionally, the predicted logarithmic decrement indicates that there is no unstable mode. The power turbine uses compressed air at a temperature of $250^{\circ}C$ in its operation, and we monitor the shaft vibration and temperature of the lubricant during the test. In the steady state, we record a temperature rise of $40^{\circ}C$ between the inlet and outlet lubricant and the measured shaft vibration shows good agreement with the prediction.