• Title/Summary/Keyword: Decreasing function

Search Result 865, Processing Time 0.029 seconds

Thermal-hydraulic behaviors of a wet scrubber filtered containment venting system in 1000 MWe PWR with two venting strategies for long-term operation

  • Dong, Shichang;Zhou, Xiafeng;Yang, Jun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1396-1408
    • /
    • 2020
  • Filtered containment venting system (FCVS) is one of the severe accident mitigation systems designed to release containment pressurization to maintain its integrity. The thermal-hydraulic behaviors in FCVSs are important since they affect the operation characteristics of the FCVS. In this study, a representative FCVS was modeled by RELAP5/Mod3.3 code, and the Station BlackOut (SBO) was chosen as an accident scenario. The thermal-hydraulic behaviors of an FCVS during long-term operation with two venting strategies (open-and-close strategy, open-and-non-close strategy) and the sensitivity analysis of important parameters were investigated. The results show that the FCVS can operate up to 250 h with a periodic open-and-close strategy during an SBO. Under the combined effects of steam condensation and water evaporation, the solution inventory in the FCVS increases during the venting phase and decreases during the intermission phase, showing a periodic pattern. Under this condition, the appropriate initial water level is 3-4 m; however, it should be adjusted according to the environment temperature. The FCVS can accommodate a decay heat power of 150-260 kW and may need to feed water for a higher decay heat power or drain water for a lower decay heat power during the late phase. The FCVS can function within an opening pressure range from 450 kPa to 500 kPa and a closing pressure range between 250 kPa and 350 kPa. When the open-and-non-close strategy is adopted, the solution inventory increases quickly in the early venting phase due to steam condensation and then decreases gradually due to the evaporation of water; drying-up may occur in the late venting phase. Decreasing the venting pipe diameter and increasing the initial water level can mitigate the evaporation of the scrubbing solution. These results are expected to provide useful references for the design and engineering application of FCVSs.

A Case Analysis of Home Health Care for Cesarean Postpartum Women and Their Newborns (제왕절개분만 산욕부와 신생아의 가정간호 사례분석)

  • 김혜숙;최연순;전은미
    • Journal of Korean Academy of Nursing
    • /
    • v.24 no.4
    • /
    • pp.696-705
    • /
    • 1994
  • This study was done to provide a basis for home health care management for women following Cesarean delivery. Furthermore it was initiated as an possible application of home health care in the future. In this study, client selection criteria was developed by the researcher and assessment tools for home health care, recording system and problem oriented recording system were revised from Jun's(1993) methods. The selection criteria tool for home health care for women who had a Cesarean delivery was structured and consisted of five areas : physical status, functional status, psychological-emetional status, educational needs status and environmental status. The structured assessment tool consisted of general items, obstetric history, past medical history, methods of feeding, medications taken before ad-mission, laboratory results, discharge instructions, discharge medications, family tree, economic status, environmental status, a map, health assessment of women and their newborns. The visit note consisted of the date : nursing problems : nursing process including initial assessment : nursing goals : visit plan : health status of the postpartum women and their newborn : nursing diagnoses : nursing implementation evaluation : summary : next visit plan and revision. The problem oriented recording system consisted of the date, problem numbers, nursing diagnoses, problem appearance date, problem resolution date. The results of the research are as follows : The seven cases having had a Cesarean delivery were discharged on an average on the 5th day after the Cesarean birth. The total number of home visits was 13. According to Cordon's functional health patterns the total possible nursing diagnoses was 34 diagnoses for the methers and their newborns. Among the 34 diagnoses, there were 13 diagnoses in the health perception /management pattern, 7 in the psychosocial health perception / management pattern, 8 in the psychosocial self-perception, 2 in the nutrition / metabolism pattern of physical function, 2 in the knowledge deficit of newborn management, anxiety related to newborn management, knowledge deficit related to disease process of new-born, anxiety related to disease process of newborn anxiety related to prognosis of baby's condition, knowledge deficit related to newborn jaundice each appeared once. The changes in the number of nursing diagnoses was related to not the number of visits but to the number of nursing diagnoses decreasing. The con-tent of the home health care was categorized ac-cording to assessment, direct care, counseling, education, family care. The recommendation based on the results of this research are Home health care nurses for Cesarean postpartum women and their neonates requires comprehensive knowledge of pregnancy, delivery, and the postpartum period and of the neonate so that they can provide appropriate care and holistic views. Most of cases terminated after the second visit, this outcome may be related to the subjects being discharged on the 5th day after delivery. Therefore, study done with earlier discharge after delivery may have different outcome. It is very hard to assess psychological aspects that need follow-up and to develop communication channels.

  • PDF

A DCF Throughput Analysis of the Ideal and Fading Channel in the Wireless LAN (무선 LAN에서 이상 및 페이딩 채널 환경의 DCF 처리율 비교 분석)

  • Lee, Yong-Sik;Lee, Ha-Cheol;Lee, Byung-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.7
    • /
    • pp.741-753
    • /
    • 2008
  • This paper explores the throughput performance of CSMA/CA-based DCF protocol over both ideal channels and fading channels with payload size at the MAC layer in the 802.11a wireless LAN. In the ideal channel, there are no errors and at the transmission cycle there is one and only one active station which always has a packet to send and other stations can only accept packets and provide acknowledgements. In the fading channel, bit errors appear in the channel randomly and the number of stations is assumed to be fixed. And each station always has packets for transmission. In other words, we operate in saturation conditions. Up to now conventional research work about DCF throughput analysis of IEEE 802.11 a wireless LAN has been done over the ideal channel, but this paper is done over the Rayleigh/Ricean fading channel. So, the ratio of received average energy per bit-to-noise power spectral density $E_b/N_o$ is set to 25 dB and the ratio of direct-to-diffuse signal power in each sub-channel $\xi$ is set to 6 for combined Rayleigh/Ricean fading channel. In conclusion, it is shown that the saturation throughput is always less than the maximum throughput at all the payload size and the higher the transmission rate be, the higher the decreasing rate of saturation throughput compared to the maximum throughput be.

Outcome of Inhaler Withdrawal in Patients Receiving Triple Therapy for COPD

  • Kim, Sae Ahm;Lee, Ji-Hyun;Kim, Eun-Kyung;Kim, Tae-Hyung;Kim, Woo Jin;Lee, Jin Hwa;Yoon, Ho Il;Baek, Seunghee;Lee, Jae Seung;Oh, Yeon-Mok;Lee, Sang-Do
    • Tuberculosis and Respiratory Diseases
    • /
    • v.79 no.1
    • /
    • pp.22-30
    • /
    • 2016
  • Background: The purpose of this study was to document outcomes following withdrawal of a single inhaler (step-down) in chronic obstructive pulmonary disease (COPD) patients on triple therapy (long-acting muscarinic antagonist and a combination of long-acting ${\beta}2$-agonists and inhaled corticosteroid), which a common treatment strategy in clinical practice. Methods: Through a retrospective observational study, COPD patients receiving triple therapy over 2 years (triple group; n=109) were compared with those who had undergone triple therapy for at least 1 year and subsequently, over 9 months, initiated inhaler withdrawal (step-down group, n=39). The index time was defined as the time of withdrawal in the step-down group and as 1 year after the start of triple therapy in the triple group. Results: Lung function at the index time was superior and the previous exacerbation frequency was lower in the step-down group than in the triple group. Step-down resulted in aggravating disease symptoms, a reduced overall quality of life, decreasing exercise performance, and accelerated forced expiratory volume in 1 second ($FEV_1$) decline ($54.7{\pm}15.7mL/yr$ vs. $10.7{\pm}7.1mL/yr$, p=0.007), but there was no observed increase in the frequency of exacerbations. Conclusion: Withdrawal of a single inhaler during triple therapy in COPD patients should be conducted with caution as it may impair the exercise capacity and quality of life while accelerating $FEV_1$ decline.

Environment-Friendly Optimum Route Selecting With Geo-spatial Information Analysis (지형공간정보분석에 따른 환경친화적 최적 도로노선 선정)

  • Kim, Sang-Seok;Jang, Yong-Gu;Choi, Su-Geun;Kang, In-Joon
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.13 no.3 s.33
    • /
    • pp.69-77
    • /
    • 2005
  • Most of the evaluations of environmental effect of construction of road do not run parallel with the evaluation of the propriety of the business, but it just reviews how to reduce contamination before the beginning of the construction work. This reveals the limitation of the induction of environment friendly development from the fundamental. In this study, a function of GIS spatial analysis for 9 elements of pre-evaluation of environmental effect has been introduced, and a GIS decision making system for environmental effect of a road has been established for an integrated evaluation by using individual evaluation result. By using GIS decision making system for pre-evaluation of environmental effect that has been developed in this study and the GIS data that has been collected, it would be possible to decrease time and money for evaluation as well as fulfill the requirement of objectivity. Therefore, it would be possible to apply for pre-evaluation of environmental effect when deciding on the route of the road at the beginning stage of the construction work. Also, through the system developed in this study, the construction body could easily induce a mutual agreement with the residents by the visual evaluation material, which might result in an evaluation of environmental effect while decreasing time and money at the beginning stage of the construction.

  • PDF

Real-time Implementation of Variable Transmission Bit Rate Vocoder Integrating G.729A Vocoder and Reduction of the Computational Amount SOLA-B Algorithm Using the TMS320C5416 (TMS320C5416을 이용한 G.729A 보코더와 계산량 감소된 SOLA-B 알고리즘을 통합한 가변 전송율 보코더의 실시간 구현)

  • 함명규;배명진
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.40 no.6
    • /
    • pp.84-89
    • /
    • 2003
  • In this paper, we real-time implemented to the TMS320C5416 the vocoder of variable bit rate applied the SOLA-B algorithm by Henja to the ITU-T G.729A vocoder of 8kbps transmission rate. This proposed method using the SOLA-B algorithm is that it is reduced the duration of the speech in encoding and is played at the speed of normal by extending the duration of the speech in decoding. At this time, we bandied that the interval of cross correlation function if skipped every 3 sample for decreasing the computational amount of SOLA-B algorithm. The real-time implemented vocoder of C.729A and SOLA-B algorithm is represented the complexity of maximum that is 10.2MIPS in encoder and 2.8MIPS in decoder of 8kbps transmission rate. Also, it is represented the complexity of maximum that is 18.5MIPS in encoder and 13.1MIPS in decoder of 6kbps, it is 18.5MIPS in encoder and 13.1MIPS in decoder of 4kbps. The used memory is about program ROM 9.7kwords, table ROM 4.5kwords, RAM 5.1 kwords. The waveform of output is showed by the result of C simulator and Bit Exact. Also, for evaluation of speech quality of the vocoder of real-time implemented variable bit rate, it is estimated the MOS score of 3.69 in 4kbps.

The Relationship Between Smoke-Yields and Tipping Materials of the Cigarette (담배 연기발생과 Tipping 재료와의 상관성 연구)

  • Kim, Young-Hoh;Lee, Young-Taek;Kim, Sung-Han;Kim, Chung-Ryul;Kim, Jong-Yeol;Shin, Chang-Ho;Lee, Keun-Hoi
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.20 no.1
    • /
    • pp.131-138
    • /
    • 1998
  • In order to minimize the trial frequency in the new filter cigarette design, we studied the relationship between smoke yield and tipping materials of cigarette. A three levels full factorial design involving filament denier (X1,2.5-3.3d), Porosity of the acetate filter plug wrap (X2, 3,500-16,000CU) and porosity of the tip paper (X3, 400-1,200CU) was used. Three independent factors (Xl, X2, X3) were chosen for their effects on the various responses and the function was expressed in terms of a quadratic polynomial equation, Y : $\beta$o + $\beta$1Xl + $\beta$2X2 + $\beta$3X3 + $\beta$11Xl2 + $\beta$22X22+ $\beta$33X32 + $\beta$12X1X2 + $\beta$13XIX3 $\beta$23X2X3 which measures the linear, quadratic, and interaction effects. Twenty-nine trial numbers were obtained as a results of using a three levels full factorial design and it was analyzed by the multiple regression analysis with backward stepwise in STATISTICA/pc under restricted conditions. Tar yields of the cigarette was affected by porosity of tip paper (0.66), filament denier (0.47) and porosity of plug wrap (0.28) in the decreasing order, and linear effect of tip paper porosity (B3) and filament denier (91) were significant at a level of 0.01($\alpha$). The filament denier and tipping paper porosity interaction F ratio among three factors had a P-value of 0,000041, indicating higher interaction between these factors. Based on the analysis of variance, the model fitted for Tar (Y1) was significant at 5% confidence level and the coefficient of determination (0.96) was the proportion of variability in the data fitted for by the model.

  • PDF

Seasonal Changes of Water Relations Parameters of the Korean Mistletoe (Viscum album var. coloratum) Leaves (겨우살이 엽의 계절별 수분특성)

  • Lee, Kyeong-Cheol;Kim, Cheol-Woo;Yi, Jae-Seon;Han, Sang-Sup
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.3
    • /
    • pp.461-468
    • /
    • 2012
  • This study was conducted to study the seasonal changes of relative water relations parameters by pressure-volume curves of Korean mistletoe (Viscum album var. coloratum) leaves for understanding ecological characteristics. In growing season, the osmotic potentials at full turgor (${\Psi}_o^{sat}$) and at incipient plasmolysis (${\Psi}_o^{tlp}$) decreased, while increased the maximum bulk elastic modulus of the cell wall ($E_{max}$) and relavive water content ($RWC^{tlp}$). Korean mistletoe in Quercus variabilis and Korean mistletoe in Quercus mongolica in November showed best maximum perssure potential (${\Psi}_{P,\;max}$). Pressure potential (${\Psi}_P$) and water potential (${\Psi}_L$) in Korean mistletoe in Quercus variabilis were rapidly decreased with decreasing of relative water content. The values of $RWC^{tlp}$ in November were all above 84% showing that the function of osmoregulation is somewhat better, and symplastic water content (Vo/DW) and maximum water content (Vt/DW) were variable seasonally. Thus, responses to water relations of Korean mistletoe in Quercus variabilis and Korean mistletoe in Quercus mongolica such as ${\Psi}_o^{sat},\;{\Psi}_o^{tlp},\;E_{max},\;{\Psi}_{P,\;max},\;RWC^{tlp}$ showed increaing drought tolerance with increasing of leaf aging.

Seminal Plasma Heparin Binding Proteins Improve Semen Quality by Reducing Oxidative Stress during Cryopreservation of Cattle Bull Semen

  • Patel, Maulikkumar;Gandotra, Vinod K.;Cheema, Ranjna S.;Bansal, Amrit K.;Kumar, Ajeet
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.9
    • /
    • pp.1247-1255
    • /
    • 2016
  • Heparin binding proteins (HBPs) are produced by accessory glands. These are secreted into the seminal fluid, bind to the spermatozoa at the time of ejaculation, favour capacitation, acrosome reaction, and alter the immune system response toward the sperm. The present study was conducted with an objective to assess the effect of purified seminal plasma-HBPs (SP-HBPs) on cross bred cattle bull sperm attributes during two phases of cryopreservation: Pre freezing and freezing-thawing. SP-HBPs were purified from pooled seminal plasma by heparin affinity chromatography. Three doses of SP-HBPs i.e. 10, 20, $40{\mu}g/mLs$ semen were standardized to find out the optimum dose and $20{\mu}g/mLs$ was found to be an optimum dose. Semen as such and treated with SP-HBPs was diluted with sodium citrate-egg yolk diluter and cryopreserved as per the standard protocol. Sperm parameters i.e. motility, viability, Hypo-osmotic swelling test (HOST), acrosome damage, in vitro capacitation and lipid peroxidation were evaluated in SP-HBP treated and untreated (control) semen at both phases of cryopreservation. A considerable variation in percent sperm motility, viability, membrane integrity (HOST), acrosome damage, acrosome reaction and lipid peroxidation was observed at both phases among the bulls irrespective of the treatment. Incubation of neat semen with $20{\mu}g/mL$ SP-HBP before processing for cryopreservation enhanced the average motility, viability, membrane integrity by 7.2%, 1.5%, 7.9%, and 5.6%, 6.6%, 7.4% in pre-frozen and frozen-thawed semen in comparison to control. There was also an average increase of 4.1%/3.9% in in vitro capacitation and acrosome reaction in SP-HBPs-treated frozen-thawed semen as compared to control. However, binding of SP-HBPs to the sperm declined acrosome damage and lipid peroxidation by 1.3%/4.1% and 22.1/$32.7{\mu}M$/$10^9$ spermatozoa in SP-HBP treated pre-frozen/frozen-thawed semen as compared to control, respectively. Significant (p<0.05) effects were observed only in motility, HOST and in vitro acrosome reaction. It can be concluded that treatment of neat semen with SP-HBPs before cryopreservation minimized the cryoinjury by decreasing the generation of reactive oxygen species.

Non-stationary Rainfall Frequency Analysis Based on Residual Analysis (잔차시계열 분석을 통한 비정상성 강우빈도해석)

  • Jang, Sun-Woo;Seo, Lynn;Kim, Tae-Woong;Ahn, Jae-Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.5B
    • /
    • pp.449-457
    • /
    • 2011
  • Recently, increasing heavy rainfalls due to climate change and/or variability result in hydro-climatic disasters being accelerated. To cope with the extreme rainfall events in the future, hydrologic frequency analysis is usually used to estimate design rainfalls in a design target year. The rainfall data series applied to the hydrologic frequency analysis is assumed to be stationary. However, recent observations indicate that the data series might not preserve the statistical properties of rainfall in the future. This study incorporated the residual analysis and the hydrologic frequency analysis to estimate design rainfalls in a design target year considering the non-stationarity of rainfall. The residual time series were generated using a linear regression line constructed from the observations. After finding the proper probability density function for the residuals, considering the increasing or decreasing trend, rainfalls quantiles were estimated corresponding to specific design return periods in a design target year. The results from applying the method to 14 gauging stations indicate that the proposed method provides appropriate design rainfalls and reduces the prediction errors compared with the conventional rainfall frequency analysis which assumes that the rainfall data are stationary.