• 제목/요약/키워드: Decrease rate

검색결과 6,181건 처리시간 0.036초

Subcooling Bypass Technology를 적용한 압축기 토출 냉매 온도 감소에 관한 연구 (A Study on the Decrease of Compressor Discharge Temperature Using Subcooling Bypass Technology)

  • 곽경민;배철호
    • 설비공학논문집
    • /
    • 제21권6호
    • /
    • pp.326-332
    • /
    • 2009
  • The purpose of the study is to decrease the refrigerant temperature at the outlet of the compressor under high thermal load conditions for air cooled vapor compression refrigeration system. The subcooling bypass line called subcooling bypass technology(SBT) is installed to the window type A/C system to investigate the performance test. The standard air calorimeter test method is applied to measure the refrigerant temperature at the outlet of the compressor, cooling capacity, power consumption, and system EER. The refrigerant temperature at the outlet of the compressor decreases as the bypass rate increases. When the bypass rate is 8.2%, the refrigerant temperature at the outlet of the compressor decreases $2.8^{\circ}C$ while the cooling capacity and EER are the same as the conventional A/C unit.

분무냉각에 의한 강판 열처리과정에 있어서 열전달분포의 측정 (Measurements of Heat Transfer Distribution in Spray Cooling of Hot Steel Plate .)

  • 김영찬;유갑종;서태원
    • 설비공학논문집
    • /
    • 제12권10호
    • /
    • pp.886-893
    • /
    • 2000
  • A good understanding of the heat transfer distribution is very important to suppress the deformation of steel products. In this study, the local heat transfer coefficients are experimentally investigated to understand the heat transfer distribution of thick steel plates with even flat spray nozzle. The steel slabs are cooled down from the initial temperature of about $1000^{\circ}C$ , and the local heat transfer coefficients and surface temperatures are calculated from the measured temperature-time history. The results show that the local heat transfer coefficients of spray cooling are dominated by the local droplet flow rate, and in proportion to becoming more distant from the center of heat transfer surface, the local heat transfer coefficients decrease with the decrease of the local droplet flow rate.

  • PDF

공기 양정(air lift) 펌프를 응용한 슬러지 배출장치에 대한 연구 (Application of Air Lift Pump for Sludge Discharger)

  • 안갑환;박영식
    • 한국환경과학회지
    • /
    • 제13권10호
    • /
    • pp.929-938
    • /
    • 2004
  • Sludge discharger applied the principle of the air lift pump was investigated experimentally for the different design( diameter of discharge pipe, diameter and height of the inside and outside wall) and operating parameters(air flow rate, water level). And it was conducted that performance comparison about sludge discharger and conventional air lift pump. The result indicated that discharged liquid were increased with the increase of air flow rate and water level and decrease distance between inside and outside wall. The discharge pressure was increased with an increase of air flow rate and a decrease of the diameter of the discharge pipe, for both the sludge discharger and the airlift pump. The discharge pressures of the sludge discharger were 3-6 times higher than those of the air lift pump.

Corrosion Fatigue Cracking of Low Alloy Steel in High Temperature Water

  • Lee, S.G.;Kim, I.S.;Jang, C.H.;Jeong, I.S.
    • Corrosion Science and Technology
    • /
    • 제2권2호
    • /
    • pp.93-97
    • /
    • 2003
  • Fatigue crack growth test or low alloy steel was performed in high temperature water. Test parameters were dissolved oxygen content. loading frequency and R-ratio ($P_{min}/P_{max}$). Since the sulfur content or the steel was low, there were no environmentally assisted cracks (EAC) in low dissolved oxygen(DO) water. At high DO, the crack growth rate at R = 0.5 tests was much increased due to environmental effects and the crack growth rate depended on loading frequency and maximized at a critical frequency. On the other hand, R = 0.7 test results showed an anomalous decrease of the crack growth rate as much different behavior from the R = 0.5. The main reason of the decrease may be related to the crack tip closure effect. All the data could be qualitatively understood by effects of oxide rupture and anion activity at crack tip.

The Effect of Solution Pressure to the Release in a Supercooled Aqueous Solution

  • Kang, Chae-Dong;Kim, Byung-Seon;Hong, Hi-Ki
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제17권1호
    • /
    • pp.25-31
    • /
    • 2009
  • Supercooled type ice storage system with aqueous solution (or water) may have trouble with non-uniform release of supercooling even though it contributes to the simplicity of system and ecological improvement. The non-uniform release increases the instability of the system because it may cause an ice blockage in pipe or cooling part. In order to suppress the release of the supercooling, a cooling experiment was tried to an ethylene glycol(EG) 3 mass% solution corresponding with pressurization. Also, the frequency ratio of the release of the supercooling was measured to the pressurization from 101 to 505 kPa. At results, the frequency ratio of supercooling release tends to decrease as the pressure of the aqueous solution increased in each cooling rate. Moreover, it tends to decrease as the cooling rate of the solution decreased in each pressure.

경량기포혼합 준설토의 강도특성 (Strength Characteristics of Light-Weight Cement mind Marine Clay with Foam)

  • 박건태;김주철;윤길림;이종규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.483-490
    • /
    • 2002
  • A massive amount of marine clay produced as dredging of coast and sea bed is often dumped in open sea and filled in pond. The treatment of marine clay demand a large area and make fatal environmental problems for echo system. This research work intend to manufacture a light-weight landfill materials which are produced by mixing the dredged marine clay with various amount cement and foam. An extensive Uniaxial and Triaxial compression test are carried out to investigate the strength characteristics of the light-weight cement mixed marine clay with foam under various test conditions. The results indicated that the required unit weight has been achieved with negligible change after 28days curing time in water. It is also recognized that the compressive strength of light-weight landfill materials linearly decrease with increasing initial water content, and the rate of strength decrease with increasing initial water content in water curing was smaller than that of air curing Futhermore, the rate of strength decreased with increasing initial water content, however, the rate become smaller as cement content increased.

  • PDF

기관 배기계 모의실험장치를 이용한 밸브를 통과하는 유동특성에 관한 연구 (A Study on the Characteristics of Flow through a Valve using Exhaust System Engine Simulator)

  • 차경옥
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권2호
    • /
    • pp.124-130
    • /
    • 1999
  • Flow characteristics of a compressible gas flow through a rotating disc-type rotary valve are investigated experimentally under various conditions. It is known that the mass flow rate through poppet valves of 4-stroke cycle engines and through piston valves of 2-stoke cycle engines decrease with increase in engine speed. Rotary valve is one means by which air may be made to flow inter-mittently through a pipe. In this paper an exhaust system simulator of engine was used to experi-mentally analyze the decrease in flow rate at high rotation speeds and to determine what variables other than rotational speed give rise to the observed behaviour. These variables have been included in an empirical equation which is representative of the measured flow characteristics.

  • PDF

감압 하에서 마그네슘 합금(AM50) 스크랩 용탕의 증발 거동에 관한 연구 (A Study on the Evaporation Behavior of Magnesium Alloy (AM50) Scrap Melt under Reduced Pressure)

  • 위창현;홍성훈;유병돈
    • 대한금속재료학회지
    • /
    • 제48권3호
    • /
    • pp.241-247
    • /
    • 2010
  • In order to develop the vacuum distillation process of magnesium alloy scrap, a fundamental study on the evaporation behavior of magnesium alloy (AM50) scrap melt was carried out. Melt temperature, pressure, reaction time, and initial specific surface area of melt were considered as experimental variables. The evaporation rate of magnesium increased with the increase of melt temperature and initial specific surface area of melt, and with the decrease of the pressure. The activation energy of magnesium evaporation reaction calculated by an Arrhenius plot decreased with the decrease of the pressure and with the increase of the initial specific surface area of melt. An empirical equation was derived for the evaporation rate of magnesium from AM50 alloy melt.

Standardization of Sample Handling Methods to Reduce the Rate of Inadequate Sampling

  • Yo-Han Seo
    • 한국의료질향상학회지
    • /
    • 제29권2호
    • /
    • pp.85-93
    • /
    • 2023
  • Purpose: The predominant approach for mitigating inadequate sampling rates has primarily involved bolstering the volume of education. This study aimed to curtail inadequate sampling rates through the implementation of continuous quality improvement (CQI) activities, tailoring effective methods to the unique needs of each institution. Methods: We developed a sample handling guidebook and implemented QI activities to address this issue. Results: These measures resulted in a 4.7% decrease in inadequate sampling rates, concurrently improving knowledge of sample handling and overall nurse satisfaction. We addressed the root causes of inadequate sampling before laboratory pre-processing by: 1) focusing on systematic rather than erratic errors through CQI activities, 2) revising the sample handling guide, and 3) delivering face-to-face education based on the specific needs of the nursing department. These changes resulted in an additional 0.6% decrease in the inadequate sampling rate. Conclusion: This study demonstrates that the implementation of CQI activities based on evidence derived from a multifaceted causal analysis significantly reduced the inadequate sampling rate compared to previous studies.

COVID-19 전후 단일 한방병원 및 한방 안이비인후피부과 외래 환자들에 대한 비교 분석 (Comparative Analysis of Outpatients Visiting Korean Medicine Hospital and Department of Ophthalmology, Otolaryngology & Dermatology of Korean Medicine Pre- versus Post- COVID-19)

  • 김병현;김준동;서광일;김규석;남혜정;김윤범
    • 한방안이비인후피부과학회지
    • /
    • 제36권1호
    • /
    • pp.96-109
    • /
    • 2023
  • Objectives : The objective of this study is to predict how future infectious diseases will affect healthcare utilization patterns within korean medicine hospitals and, specifically, departments of ophthalmology, otolaryngology and dermatology of Korean medicine. Methods : We retrospectively analyzed medical records of patients who visited Kyung Hee University Korean Medicine Hospital during Pre COVID-19(from March 1st, 2018 to Feb 29th, 2019) and Post COVID-19(from March 1st, 2019 to Feb 28th, 2022). The data was analyzed by visit type and diagnosed disease code. Results : 1. After the COVID-19 break-out, the number of first visit patients increased but those of revisit patients, total patients, and revisit/first visit ratio decreased in all departments. 2. In Kyung Hee University Korean Medicine Hospital, the decrease rate of the number of total patients diagnosed with diseases of respiratory system(J00-J99) was the highest, while that for diseases of circulatory system(I00-I99) was the lowest. 3. In the department of Ophthalmology and Otolaryngology of Korean Medicine, the decrease rate of the number of total patients with nose disease was the highest, followed by eye disease and ear disease. 4. In the department of Dermatology of Korean Medicine, the number of total patients with dermatitis remained consistent, while the number of total patients with skin appendage disease showed relatively high decrease rate. Conclusions : Severe or chronic diseases showed relatively low decrease rate of the number of total patients. While mild diseases or diseases with high probability of exposure to COVID-19 infection during treatment showed high decrease rate of the number of total patients.