• 제목/요약/키워드: Decrease rate

검색결과 6,181건 처리시간 0.034초

Compressive behavior of circular hollow and concrete-filled steel tubular stub columns under atmospheric corrosion

  • Gao, Shan;Peng, Zhen;Wang, Xuanding;Liu, Jiepeng
    • Steel and Composite Structures
    • /
    • 제33권4호
    • /
    • pp.615-627
    • /
    • 2019
  • This paper aims to study the compressive behavior of circular hollow and concrete-filled steel tubular stub columns under simulated marine atmospheric corrosion. The specimens after salt spray corrosion were tested under axial compressive load. Steel grade and corrosion level were mainly considered in the study. The mechanical behavior of circular CFST specimens is compared with that of the corresponding hollow ones. Design methods for circular hollow and concrete-filled steel tubular stub columns are modified to consider the effect of marine atmospheric corrosion. The results show that linear fitting curves could be used to present the relationship between corrosion rate and the mechanical properties of steel after simulated marine atmospheric corrosion. The ultimate strength of hollow steel tubular and CFST columns decrease with the increase of corrosion rate while the ultimate displacement of those are hardly affected by corrosion rate. Increasing corrosion rate would change the failure of CFST stub column from ductile failure to brittle failure. Corrosion rate would decrease the ductility indexes of CFST columns, rather than those of hollow steel tubular columns. The confinement factor ${\xi}$ of CFST columns decreases with the increase of corrosion rate while the ratio between test value and nominal value shows an opposite trend. With considering marine atmospheric corrosion, the predicted axial strength of hollow steel tubular and CFST columns by Chinese standard agree well with the tested values while the predictions by Japanese standard seem conservative.

Blending Effect on the Mechanical and Hand Properties of Wool/Acrylic Blend Knits

  • Park Myung-Ja
    • The International Journal of Costume Culture
    • /
    • 제8권1호
    • /
    • pp.23-31
    • /
    • 2005
  • Mechanical properties and hand evaluation of wool/acrylic(W/A) blend knits were conducted before and after repeated washing to get the optimum W/A blending ratio, which could help achieve the optimum mechanical and hand properties of the knits. The five test fabrics using the yarns with different W/A blending ratios($\%$), 100/0, 70/30, 50/50, 30/70, 0/100, were knitted. The fabrics were washed by a rotating drum type washing machine. Then, objective mechanical and hand properties were evaluated by KES-FB, Kawabata evalution system for fabric. The results are as follows: there was no change in the hand value of the knitted fabric with the W/A-blended yarn caused by the change in the blending ratio before washing. After washing, however, the increase of acrylic's blending rate caused the bending property to decrease proportionally, while the friction coefficient of the surface property increased. Furthermore, the study showed that W/A 50/50 possesses the most superior tensile property and shearing property, which could attain the optimum blending ratio. Similar results in hand value were derived in all the samples. After washing, however, the increase in acrylic's blending rate caused a proportional decrease in KOSHI and an increase in FUKURAMI. In addition, W/A 50/50 gained the biggest NUMERI value, again corresponding to the optimum blending ratio. Similar results in total hand value were derived in all the samples before washing. After washing, though, all the total hand values decreased, and, as the wool fabric's blending rate increased, the total hand values proportionally decreased further.

  • PDF

메탄-공기 대향류확산화염에서 $CO_2$$H_2O$의 첨가가 화염구조와 NOx배출특성에 미치는 화학적 영향 (Chemical effects of added $CO_{2}$ and $H_{2}O$ to major flame structures and NOx emission characteristics in $CH_4$/Air Counterflow Diffusion Flames)

  • 황동진;박정;이경환;길상인
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 제26회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.129-136
    • /
    • 2003
  • Numerical study with momentum-balanced boundary conditions has been conducted to grasp chemical effects of added $CO_{2}$ and $H_{2}O$ to fuel- and oxidizer-sides on flame structure and NO emission behavior in $CH_{4}$/Air counterflow diffusion flames. The dilution with $H_{2}O$ results in significantly higher flame temperatures and NO emission, but dilution with $CO_{2}$ has much more chemical effects than that with $H_{2}O$. Maximum reaction rate of principal chain branching reaction due to chemical effects decreases with added $CO_{2}$. but increases with added $H_{2}O$. The NO emission behavior is closely related to the production rate of OH, CH and N. The OH radical production rate increases with added $H_{2}O$ but those of CH, N decrease. On the other hand the production rates of OR CH and N decrease with added $CO_{2}$. It is found that NO emission behavior is considerably affected by chemical effects of added $CO_{2}$ and $H_{2}O$.

  • PDF

EGR 장착 스파크 점화 LPG 엔진의 성능 및 배기특성 (Performance and Emission Characteristics in a Spark-Ignition LPG Engine with Exhaust Gas Recirculation)

  • 조윤호;구준모;장진영;배충식
    • 한국자동차공학회논문집
    • /
    • 제10권1호
    • /
    • pp.24-31
    • /
    • 2002
  • An experimental study was conducted to investigate the effects of EGR (Exhaust Gas Recirculation) variables on performance and emission characteristics in a 2-liter 4-cylinder spark-ignition LPG fuelled engine. The effects of EGR on the reduction of thermal loading at exhaust manifold were also investigated because the reduced gas temperature is desirable for the reliability of an engine in light of both thermal efficiency and material issue of exhaust manifold. The steady-state tests show that the brake thermal efficiency increased and the brake specific fuel consumption decreased with the increase of EGR rate in hot EGR and with the decrease of EGR temperature in case of cooled EGR, while the stable combustion was maintained. The increase of EGR rate or the decrease of EGR temperature results in the reduction of NOx emission even in the increase of HC emission. Furthermore, decreasing EGR temperature by $180^{\circ}C$ enabled the reduction of exhaust gas temperature by $15^{\circ}C$ in cooled EGR test at 1600rpm/370kPa BMEP operation, and consequently the reduction of thermal load at exhaust. The optimization strategy of EGR application is to be discussed by the investigation on the effect of geometrical characteristics of EGR-supplying pipe line.

가토(家兎) 신장기능(腎臟機能)에 미치는 측뇌실내(側腦室內) Ouabain의 영향(影響) (Influence of Intraventricular Ouabain on the Renal Function of the Rabbit)

  • 이신웅
    • 대한약리학회지
    • /
    • 제12권1호
    • /
    • pp.31-44
    • /
    • 1976
  • It has been reported that many of the effects of digitalis glycosides could be mediated partly through the central nervous system. In this study the effects of ouabain given directly into the lateral ventricle of the brain on the renal function of the rabbit were investigated. Intraventricular ouabain elicited antidiuresis in doses ranging from 0.1 to $3\;{\mu}g$, exhibiting a rough dose-response relationship, and decreased the renal plasma flow, glomerular filtration rate and urinary excretion of sodium and potassium, concomitant with the decrease of urine flow. These decreases in urine flow, excretory rate of electrolytes significantly correlated with the decrease in renal plasma flow or glomerular filtration rate, suggesting that the antidiuresis might have been induced by the hemodynamic changes. Intravenous ouabain in a dose of $1\;{\mu}g$ did not affect the renal function. Systemic blood pressure as well as cardiac activity was not affected by the intraventricular ouabain. Effects of the intraventricular ouabain on renal function were abolished by the intravenous phentolamine-pretreatment but not affected by intraventricular phentolamine-pretreatment. Neither vasopressin infusion nor hydration did affect the renal effects of intraventricular ouabain. From these observations, it is suggested that the antidiuresis of intraventricular ouabain is induced by the increased sympathetic influence to the kidney.

  • PDF

치은 섬유아세포(纖維芽細胞)에 대(對)한 은(銀)-파라디움합금(合金)의 세포독성(細胞毒性)에 관(關)한 연구(硏究) (AN EXPERIMENTAL STUDY OF THE CYTOTOXICITY OF SILVERPALLADIUM ALLOYS UPON GINGIVAL FIBROBLAST BY MEANS OF TISSUE CULTURE)

  • 유인탁;최부병;김인철
    • 대한치과보철학회지
    • /
    • 제21권1호
    • /
    • pp.9-26
    • /
    • 1983
  • In order to investigate the biocompatibility of silver-palladium alloys, gingival fibroblast was obtained from a healthy human gingival and cultured in MEM medium with the addition of silverpalladium alloys. Four different mixture of silver-palladium alloys comprising of Ag-Pd-Au, Ag-Pd-In and Ag-Sn were tested. Results were assessed by calculating the cell multiplication rate per millimeter of medium and morphological changes in cells were also observed and noted.The obtained results were as follows; 1. Ag-Pd-Au alloy was indicated to be most biocompatible with gingival fibroblast. Also there was a decrease in cytotoxicity of the alloy as the concentration of gold increased. 2. Ag-Pd alloy showed a decrease in cell multiplication rate as compared to Ag-Pd~Au alloy. 3. Silver-palladium alloy supplemented with Indium increased the cell multiplication rate. 4. Among the alloys tested, Ag-Sn alloy was indicated to be the most cytotoxic and the least biocompatible with human gingival fibroblast.

  • PDF

An Experimental Study on the Performance of Air/Water Direct Contact Air Conditioning System

  • Yoo, Seong-Yeon;Kwon, Hwa-Kil
    • Journal of Mechanical Science and Technology
    • /
    • 제18권6호
    • /
    • pp.1002-1009
    • /
    • 2004
  • Direct contact air conditioning systems, in which heat and mass are transferred directly between air and water droplets, have many advantages over conventional indirect contact systems. The purpose of this research is to investigate the cooling and heating performances of direct contact air conditioning system for various inlet parameters such as air velocity, air temperature, water flow rate and water temperature. The experimental apparatus comprises a wind tunnel, water spray system, scrubber, demister, heater, refrigerator, flow and temperature controller, and data acquisition system. The inlet and outlet conditions of air and water are measured when the air contacts directly with water droplets as a counter flow in the spray section of the wind tunnel, and the heat and mass transfer rates between air and water are calculated. The droplet size of the water sprays is also measured using a Malvern Particle Analyzer. In the cooling conditions, the outlet air temperature and humidity ratio decrease as the water flow rate increases and as the water temperature, air velocity and temperature decrease. On the contrary, the outlet air temperature and humidity ratio increase in the heating conditions as the water flow rate and temperature increase and as the air velocity decreases.

단일 휴가형 Geo/Geo/1/K 대기행렬의 바쁜 기간 분석 (Busy Period Analysis of the Geo/Geo/1/K Queue with a Single Vacation)

  • 김길환
    • 산업경영시스템학회지
    • /
    • 제42권4호
    • /
    • pp.91-105
    • /
    • 2019
  • Discrete-time Queueing models are frequently utilized to analyze the performance of computing and communication systems. The length of busy period is one of important performance measures for such systems. In this paper, we consider the busy period of the Geo/Geo/1/K queue with a single vacation. We derive the moments of the length of the busy (idle) period, the number of customers who arrive and enter the system during the busy (idle) period and the number of customers who arrive but are lost due to no vacancies in the system for both early arrival system (EAS) and late arrival system (LAS). In order to do this, recursive equations for the joint probability generating function of the busy period of the Geo/Geo/1/K queue starting with n, 1 ≤ n ≤ K, customers, the number of customers who arrive and enter the system, and arrive but are lost during that busy period are constructed. Using the result of the busy period analysis, we also numerically study differences of various performance measures between EAS and LAS. This numerical study shows that the performance gap between EAS and LAS increases as the system capacity K decrease, and the arrival rate (probability) approaches the service rate (probability). This performance gap also decreases as the vacation rate (probability) decrease, but it does not shrink to zero.

막오염에 의한 압축기 성능 저하가 발전용 가스터빈 설계점 성능에 미치는 영향에 관한 연구 (Performance degradation due to compressor fouling of an industrial gas turbine operating at design point condition)

  • 서진식;손정락;김재환;김동섭;노승탁
    • 한국유체기계학회 논문집
    • /
    • 제6권3호
    • /
    • pp.36-43
    • /
    • 2003
  • Operating performance of industrial gas turbines in combined cycle power plants depends upon atmospheric conditions. Compressor fouling caused by airborne particles in the atmosphere and their adhesions on compressor blades is one of critical phenomena related to the performance degradation of industrial gas turbines. Compressor fouling provokes increase of pressure loss in inlet duct, decrease of mass flow rate of intake air and decrease of compressor stage efficiency. In this study, impacts of compressor fouling on the performance of an industrial gas turbine operating at design point condition are investigated analytically. As results, it is found that the reduction of produced power with decreased mass flow rate of intake air caused by narrowed flow area by the adhesion of airborne particles on compressor blades is the most dominant impact on the gas turbine performance by the compressor fouling phenomena.

Solar Flare Occurrence Rate and Probability Depending on Sunspot Classification with Active Region Area and Its Change

  • 이강진;문용재
    • 천문학회보
    • /
    • 제37권1호
    • /
    • pp.88.2-88.2
    • /
    • 2012
  • We investigate solar flare occurrence rate and daily flare probability depending on McIntosh sunspot classification, its area, and its area change. For this we use the NOAA active region and GOES solar flare data for 15 years (from January 1996 to December 2010). We consider the most flare-productive 10 sunspot classification: 'Dko', 'Dai', 'Eai', 'Fai', 'Dki', 'Dkc', 'Eki', 'Ekc', 'Fki', and 'Fkc'. Sunspot area and its change can be a proxy of magnetic flux and its emergence/cancellation, respectively. we classify each sunspot group into two sub-groups: 'Large' and 'Small'. In addition, for each group, we classify it into three sub-groups according to sunspot group area change: 'Decrease', 'Steady', and 'Increase'. As a result, in the case of compact groups, their flare occurrence rates and daily flare probabilities noticeably increase with sunspot group area. We also find that the flare occurrence rates and daily flare probabilities for the 'Increase' sub-groups are noticeably higher than those for the other sub-groups. In case of the (M+X)-class flares of 'Dkc' group, the flare occurrence rate of the 'Increase' sub-group is three times higher than that of the 'Steady' sub-group. Mean flare occurrence rates and flare probabilities for all sunspot regions increase with the following order: 'Steady', 'Decrease', and 'Increase'. Our results statistically demonstrate that magnetic flux and its emergence enhance major solar flare occurrence. We are going to forecast solar flares based on these results and NOAA scale.

  • PDF