• Title/Summary/Keyword: Decoupling power control

Search Result 99, Processing Time 0.026 seconds

A Study on the Parameter Estimation of an Induction Motor using Neural Networks (신경회로망을 이용한 유도전동기의 피라미터 추정)

  • 류한민;김성환;박태식;유지윤
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.225-229
    • /
    • 1998
  • If there is a mismatch between the controller programmed rotor time constant and the actual time constant of motor, the decoupling between the flux and torque is lost in an indirect rotor field oriented control. This paper presents a new estimation scheme for rotor time constant using artificial neural networks. The parameters of induction motor model organize 2 layer neural to be weight between neuron, which is proposed new in this paper. This method makes networks simple, so its brings not only the improvement in speed but simplification in calculation. Furthermore, it is possible to estimated rotor time constant real time through on-line learning without using off-line learning. The digital simulation and the experimental results to verify the effectiveness of the new method are described in this paper.

  • PDF

Overview of the development of smart base isolation system featuring magnetorheological elastomer

  • Li, Yancheng;Li, Jianchun
    • Smart Structures and Systems
    • /
    • v.24 no.1
    • /
    • pp.37-52
    • /
    • 2019
  • Despite its success and wide application, base isolation system has been challenged for its passive nature, i.e., incapable of working with versatile external loadings. This is particularly exaggerated during near-source earthquakes and earthquakes with dominate low-frequency components. To address this issue, many efforts have been explored, including active base isolation system and hybrid base isolation system (with added controllable damping). Active base isolation system requires extra energy input which is not economical and the power supply may not be available during earthquakes. Although with tunable energy dissipation ability, hybrid base isolation systems are not able to alter its fundamental natural frequency to cope with varying external loadings. This paper reports an overview of new adventure with aim to develop adaptive base isolation system with controllable stiffness (thus adaptive natural frequency). With assistance of the feedback control system and the use of smart material technology, the proposed smart base isolation system is able to realize real-time decoupling of external loading and hence provides effective seismic protection against different types of earthquakes.

Decoupling of Thrust Force and Levitation Force of Transverse Flux Linear Induction Motor by the Active Compensation of Magnetic force across the Air-Gap (공극력의 능동적 보상을 통한 횡자속 선형 유도 구동기의 추력과 부상력의 비연성화)

  • 정광석;백윤수
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.11
    • /
    • pp.91-98
    • /
    • 2004
  • TFLIM(Transverse Flux Linear Induction Motor), making its closed magnetic path with the direction of the traveling field orthogonal, had been developed to decrease an edge effect of the general induction motor. To control the levitation force and the thrust force on the secondary part of TFLIM independently, the various methodologies have been presented. When we try to achieve the independent control using only the multi-phase inputs assigned in the stator coils as an approach, in which condition we can minimize the coupling effect between two forces\ulcorner In this paper, we show the qualitative influence of a slip frequency, an ac magnitude, a dc offset superposed in the ac power, and a major parameter of TFLIM on the couple through the computer simulation. And to realize the independent motions between levitation and thrust motion without any auxiliary means fur isolation of the secondary part of TFLIM, the decouple compensator is suggested, including the experimental results.

An Inductance Voltage Vector Control Strategy and Stability Study Based on Proportional Resonant Regulators under the Stationary αβ Frame for PWM Converters

  • Sun, Qiang;Wei, Kexin;Gao, Chenghai;Wang, Shasha;Liang, Bin
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1110-1121
    • /
    • 2016
  • The mathematical model of a three phase PWM converter under the stationary αβ reference frame is deduced and constructed based on a Proportional-Resonant (PR) regulator, which can replace trigonometric function calculation, Park transformation, real-time detection of a Phase Locked Loop and feed-forward decoupling with the proposed accurate calculation of the inductance voltage vector. To avoid the parallel resonance of the LCL topology, the active damping method of the proportional capacitor-current feedback is employed. As to current vector error elimination, an optimized PR controller of the inner current loop is proposed with the zero-pole matching (ZPM) and cancellation method to configure the regulator. The impacts on system's characteristics and stability margin caused by the PR controller and control parameter variations in the inner-current loop are analyzed, and the correlations among active damping feedback coefficient, sampling and transport delay, and system robustness have been established. An equivalent model of the inner current loop is studied via the pole-zero locus along with the pole placement method and frequency response characteristics. Then, the parameter values of the control system are chosen according to their decisive roles and performance indicators. Finally, simulation and experimental results obtained while adopting the proposed method illustrated its feasibility and effectiveness, and the inner current loop achieved zero static error tracking with a good dynamic response and steady-state performance.

Modified Modular Multilevel Converter with Submodule Voltage Fluctuation Suppression

  • Huang, Xin;Zhang, Kai;Kan, Jingbo;Xiong, Jian
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.942-952
    • /
    • 2017
  • Modular multilevel converters (MMCs) have been receiving extensive research interest in high/medium-voltage applications due to its modularity, scalability, reliability, high-voltage capability, and excellent harmonic performance. Submodule capacitors are usually rather bulky because they have to withstand fundamental frequency voltage fluctuations. To reduce the capacitance of these capacitors, this study proposes a modified MMC with an active power decoupling circuit within each submodule. The modified submodule contains an auxiliary half bridge, with its capacitor split in two. Also, the midpoints of the half bridge and the split capacitors are connected by an inductor. With this modified submodule, the fundamental frequency voltage fluctuation can be suppressed to a great extent. The second-order voltage fluctuation, which is the second most significant component in submodule voltage fluctuations, is removed by the proper control of the second-order circulating current. Consequently, the submodule capacitance is significantly reduced. The viability and effectiveness of the proposed new MMC are confirmed by the simulation and experimental results. The proposed MMC is best suited for medium-voltage applications where power density is given a high priority.

Operational Principles and Decoupled Power Control of Three-Ports Half Bridge Converter for DC Microgrid System (DC 마이크로 그리드를 위한 Three-Ports Half Bridge 컨버터의 동작원리 및 독립 전력 제어에 관한 연구)

  • Sim, Ju-Young;Choi, Hyun-Jun;Lee, Jun-Young;Jung, Jee-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.228-230
    • /
    • 2018
  • DC 마이크로 그리드를 위한 Three-Ports Half Bridge (THB) 제안하고 THB 컨버터의 효과적인 제어를 위한 동작 원리 및 수학적 모델링 그리고 각 포트 간의 전력을 독립적으로 제어하는 디커플링(Decoupling) 방법을 제안하고자 한다. DC 마이크로 그리드에서는 수용자의 부하 상황에 따라 계통뿐만 아니라 분산 전원 및 에너지 저장장치(ESS) 등에서도 전력을 공급받을 수 있다. 이로 인해 기존 전력제어 시스템의 경우 2-포트 컨버터 2개가 필요하고, 이는 부피뿐만 아니라 소자의 개수도 증가시키기 때문에 제작 및 설치 단가가 상승한다는 단점이 있다. 3-포트 컨버터의 경우, 하나의 변압기를 이용하고 전력스위치와 수동소자의 개수를 줄일 수 있으므로 기존의 전력변환장치 대비 전력 밀도를 높일 수 있다. 하지만 하나의 변압기를 이용하여 3개의 포트가 연결되어 있어 서로 간의 전력간섭이 일어나고. 과도기 때 의도 하지 않은 전력의 흐름이 발생할 수 있게 된다. 본 논문에서는 수학적 모델링과 분석을 통해 3-포트 컨버터의 동작원리를 알아보고, 각 포트 간 전력 제어의 상호 간섭을 제거할 수 있는 디커플링 방법을 제안하고자 한다. 또한, 모의시험과 1 kW급 시작품을 이용하여 제안한 디커플링 전력제어 방법의 타당성을 검증하였다.

  • PDF

Optimal Design Method of 1-Port Surge Protective Device Based on Zinc Oxide Varistor (선화아연바리스터 기반의 1-포트 서지보호장치의 최적 설계 기법)

  • Jeong, Tae-Hoon;Kim, Young-Sung;Park, Geun-Bo;Lee, Seung-IL
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.93-102
    • /
    • 2018
  • This paper reports a Surge Protective Device (SPD) that is used to protect an automatic metering interface (AMI) power supplies of communication equipment on a low-voltage distribution system from a lightning current. The surge protective device (SPD) can be classified as one-port SPDs and two-port SPDs with decoupling elements depending on the connection type. The protection of internal systems against the lightning current may require a systematic approach consisting of coordinated SPDs. To deal with this, the definition of a lightning protection zone (LPZ) was studied and interpreted through a theoretical review. Because the lightning current resulting from a lightning surge is considerably high, there is limited protection from one SPD; therefore, coordinated cascaded MOV-based SPDs are installed to solve this problem. Regarding the power grid mentioned in this paper, a class II SPD for the low-voltage distribution system installed on the border of LPZ1 and LPZ2, which establish a protection coordination with the Arrester (LA, SA) that corresponds to the LPZO installed on the MOF stage connected to one system were designed to protect various communication (control) equipment, including the automatic meter reading system inside the branch-type electric supply panel of a building, not the incoming side of one system. In addition, performance-related tests were done by a comparison with the existing method through testing, and the optimal design was achieved for the 1-port SPD that uses a series connection and can bleed load current without any decoupling element.

Design and Implementation of SDN-based 6LBR with QoS Mechanism over Heterogeneous WSN and Internet

  • Lee, Tsung-Han;Chang, Lin-Huang;Cheng, Wei-Chung
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.2
    • /
    • pp.1070-1088
    • /
    • 2017
  • Recently, the applications of Internet of Things (IoTs) are growing rapidly. Wireless Sensor Network (WSN) becomes an emerging technology to provide the low power wireless connectivity for IoTs. The IPv6 over low-power wireless personal area networks (6LoWPAN) has been proposed by IETF, which gives each WSN device an IPv6 address to connect with the Internet. The transmission congestion in IoTs could be a problem when a large numbers of sensors are deployed in the field. Therefore, it is important to consider whether the WSN devices have be completely integrated into the Internet with proper quality of service (QoS) requirements. The Software Defined Network (SDN) is a new architecture of network decoupling the data and control planes, and using the logical centralized control to manage the forwarding issues in large-scale networks. In this research, the SDN-based 6LoWPAN Border Router (6LBR) is proposed to integrate the transmission from WSNs to Internet. The proposed SDN-based 6LBR communicating between WSNs and the Internet will bring forward the requirements of end-to-end QoS with bandwidth guarantee. Based on our experimental results, we have observed that the selected 6LoWPAN traffic flows achieve lower packet loss rate in the Internet. Therefore, the 6LoWPAN traffic flows classified by SDN-based 6LBR can be reserved for the required bandwidth in the Internet to meet the QoS requirements.

A Robust PLL of PCS for Fuel Cell System under Unbalanced Grid Voltages (불평형 계통전압에 강인한 연료전지용 전력변환시스템의 PLL 방법)

  • Kim, Yun-Hyun;Kim, Wang-Rae;Lim, Chang-Jin;Kim, Kwang-Seob;Kwon, Byung-Ki;Choi, Chang-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.103-105
    • /
    • 2008
  • In grid-interconnection system, a fast, robust and precise phase angle detector is most important to grid synchronization and the active power control. The phase angle can be easily estimated by synchronous dq PLL system. On the other hand under unbalanced voltage condition, synchronous dq PLL system has problem that harmonics occur to phase angle or magnitude of grid voltage because of the effect of the negative sequence components. So, To eliminate the negative sequence components, the PLL method using APF (All Pass Filter) in a stationery reference frame to extract positive sequence components under unbalanced voltage condition is researched. In this paper, we propose a new PLL method with decoupling network using APF in a synchronous reference frame to extract the positive sequence components of the grid voltage under unbalanced grid. The cut-off frequency of APF in a synchronous reference frame can be set to twice of the fundamental frequency comparing with that of APF in a stationery reference frame which is the fundamental frequency. The proposed PLL strategy can detect the phase angle quickly and accurately under unbalanced gird voltages. Simulation and experimental results are presented to verify the proposed strategy under different kind of voltage dips.

  • PDF