• Title/Summary/Keyword: Dead volume

Search Result 134, Processing Time 0.025 seconds

Analysis of the Wet-end Dynamics in Paper Mills

  • 류재용;여영구;서동준;강홍
    • 한국펄프종이공학회:학술대회논문집
    • /
    • 한국펄프종이공학회 2003년도 추계학술발표논문집
    • /
    • pp.306-330
    • /
    • 2003
  • The wet-end dynamics of a paper mill was analyzed to characterize its dynamic behavior during the grade change. The model representing the wet-end section is developed based on the mass balance relationships written for the simplified wet-end white water network. From the linearization of the dynamic model, higher-order Laplace transfer functions were obtained followed by the reduction procedure to give simple lower-order models in the form of $1^{st}$-order or $2^{nd}$-order plus dead times. The dynamic response of the wet-end is influenced both by the white water volume and by the level of wire retention. Effects of key manipulated variables such as the thick stock flow rate, the ash flow rate and the retention aid flow rate on the major controlled variables were analyzed by numerical simulations. The simple dynamic model developed in the present study can be effectively used in the operation and control.

  • PDF

Analysis of the Wet-end Dynamics in Paper Mills

  • Ryu, Jae-Yong;Yeo, Yeong-Koo;Yi, Sung-Chul;Seo, Dong-Jun;Hong Kang
    • 펄프종이기술
    • /
    • 제35권5호
    • /
    • pp.26-36
    • /
    • 2003
  • The wet-end dynamics of a paper mill was analyzed to characterize its dynamic behavior during the grade change of paper. The model representing the wet-end section is developed based on the mass balance relationships written for the simplified wet-end white water network. From the linearization of dynamic model, higher-order Laplace transfer functions were obtained followed by the reduction procedure to give simple lower-order models in the form of 1$^{st}$-order or 2$^{nd}$ -order plus dead times. The dynamic response of the wet-end is influenced both by the white water volume and by the level of wire retention. Effects of key manipulated variables such as the thick stock flow rate, the ash flow rate and the retention aid flow rate on the major controlled variables were analyzed by numerical simulations. The simple dynamic model developed in the present study can be effectively used in the operation and control of paper mills.s.

상악골 전절제술 및 안와내용물 적출술 후 횡복직근 유리피판을 이용한 3차원적 재건에 대한 치험례 (Clinical Experience of Three-dimensional Reconstruction Using Free TRAM Flap after Total Maxillectomy with Orbital Exenteration)

  • 이승렬;우종설
    • 대한두개안면성형외과학회지
    • /
    • 제10권1호
    • /
    • pp.40-43
    • /
    • 2009
  • Purpose: Extensive midface defect following total maxillectomy with orbital exenteration and cheek skin resection should be three dimensionally reconstructed with a large flap that have a sufficient volume of tissue and multiple skin islands. We describe our transverse rectus abdominis myocutaneous(TRAM) free flap with three skin islands which was successfully used in this situation. Methods: A 58-year-old man was performed enbloc total maxillectomy including orbital contents and wide cheek skin because of invasive maxillary squamous cell carcinoma. He was immediately reconstructed with TRAM flap that was designed not vertical but transverse fashion for providing sufficient skin area. Also, deepithelialization procedure making for multiple skin islands was done in flap insetting period when appropriate modification according to the intraoperative situation was possible. Dead space was completely obliterated by bulky muscular tissue, and three skin islands were used for lining of lateral nasal wall, palatal surface, and cheek skin restoration. Results: Postoperative course was satisfying. Maintaining of proper ipsilateral nasal airway, loss of rhinolalia and oronasal regurgitation of food particles, and restoration of cheek contour were successfully obtained. Conclusion: We report clinical experience of threedimensional reconstruction using free TRAM flap after total maxillectomy with orbital exenteration.

Performance of non-prismatic simply supported prestressed concrete beams

  • Raju, P. Markandeya;Rajsekhar, K.;Sandeep, T. Raghuram
    • Structural Engineering and Mechanics
    • /
    • 제52권4호
    • /
    • pp.723-738
    • /
    • 2014
  • Prestressing is the most commonly employed technique in bridges and long span beams in commercial buildings as prestressing results in slender section with higher load carrying capacities. This work is an attempt to study the performance of a minimum weight prestressed concrete beam adopting a non-prismatic section so that there will be a reduction in the volume of concrete which in turn reduces the self-weight of the structure. The effect of adopting a non-prismatic section on parameters like prestressing force, area of prestressing steel, bending stresses, shear stresses and percentage loss of prestress are established theoretically. The analysis of non-prismatic prestressed beams is based on the assumption of pure bending theory. Equations are derived for dead load bending moment, eccentricity, and depth at any required section. Based on these equations an algorithm is developed which does the stress checks for the given section for every 500 mm interval of the span. Limit state method is used for the design of beam and finite difference method is used for finding out the deflection of a non-prismatic beam. All the parameters of nonprismatic prestressed concrete beams are compared with that of the rectangular prestressed concrete members and observed that minimum weight design and economical design are not same. Minimum weight design results in the increase in required area of prestressing steel.

Effect of Caffeine, cAMP and Cattle Seminal Plasma on Freezability of Buffalo Bull Semen

  • Singh, P.;Raina, V.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제13권7호
    • /
    • pp.901-905
    • /
    • 2000
  • An experiment was conducted to investigate the effect of caffeine, cAMP and cattle seminal plasma on preservation of semen at ultra low temperature ($-196{^{\circ}C}$). Each semen sample was divided into four parts equal in volume and sperm concentration; three were treated with caffeine, or cAMP, or cattle seminal plasma (CSP) and the fourth was kept as control. Sperm motility, abnormal spermatozoa, live-dead count and acrosomal damage were studied at different stages of freeze preservation viz.; just after dilution, at $5{^{\circ}C}$, at glycerolisation, before freezing, just after freezing, 24 hours of storage, and one week of storage. Sperm motility (58.39, 61.33, 52.00 and 50.39 per cent), non-eosinophilic spermatozoa (72.55, 69.98, 63.31 and 67.64 per cent), abnormal spermatozoa (5.71, 4.98, 8.04 and 5.66 per cent) and acrosomal damage (13.28, 13.33, 14.80 and 14.65 per cent) were observed in cAMP, caffeine, cattle seminal plasma and control, respectively, at every stage of freeze preservation. From this study it could be concluded that freezability of buffalo semen can be improved through the addition of caffeine followed by cAMP and cattle seminal plasma.

상온 능동형 자기 재생 냉동기의 개발 (Development of the active magnetic regenerative refrigerator for room temperature application)

  • 박인명;김영권;정상권
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권3호
    • /
    • pp.60-64
    • /
    • 2012
  • In this paper, an investigation of a room temperature active magnetic regenerative refrigerator is carried out. Experimental apparatus includes two active magnetic regenerators containing 186 g of Gd spheres. Four E-type thermocouples are installed inside the Active magnetic regenerator(AMR) to observe the instantaneous temperature variation of AMR. Both warm and cold heat exchangers are designed for large temperature span. The cold heat exchanger, which separates the two AMRs, employs a copper tube with length of 80 mm and diameter of 6.35 mm. In order to minimize dead volume between the warm heat exchanger and AMRs, the warm heat exchangers are located close to the AMRs. The deionized water is used as a heat transfer fluid, and maximum 1.4 T magnetic field is supplied by Halbach array of permanent magnets. The AMR plate, which contains the warm and the cold heat exchangers and the AMRs, has reciprocating motion using a linear actuator and each AMR is alternatively magnetized and demagnetized by a Halbach array of permanent magnet. Since the gap of the Halbach array of permanent magnets is 25 mm and two warm heat exchangers have the motion through it, a compact printed circuit heat exchanger (PCHE) is used as a warm heat exchanger. A maximum no-load temperature span of 26.8 K and a maximum cooling power of 33 W are obtained from the fabricated Active Magnetic Regenerative Refrigerator (AMRR).

고효율 및 고역률 LED 구동회로 위한 Balanced Forward-Flyback 컨버터 (Balanced Forward-Flyback Converter for High Efficiency and High Power Factor LED Driver)

  • 황민하;강정일;한상규
    • 전력전자학회논문지
    • /
    • 제18권5호
    • /
    • pp.492-500
    • /
    • 2013
  • A balanced forward-flyback converter for high efficiency and high power factor using a foward and flyback converter topologies is proposed in this paper. The conventional AC/DC flyback converter can achieve a good power factor but it has the high offset current through the transformer magnetizing inductor, which results in a large core loss and low power conversion efficiency. And, the conventional forward converter can achieve the good power conversion efficiency with the aid of the low core loss but the input current dead zone near zero cross AC input voltage deteriorates the power factor. On the other hand, since the proposed converter can operate as the forward and flyback converters during switch turn-on and turn-off periods, respectively, it cannot only perform the power transfer during an entire switching period but also achieve the high power factor due to the flyback operation. Moreover, since the current balanced capacitor can minimize the offset current through the transformer magnetizing inductor regardless of the AC input voltage, the core loss and volume of the transformer can be minimized. Therefore, the proposed converter features a high efficiency and high power factor. To confirm the validity of the proposed converter, theoretical analysis and experimental results from a prototype of 24W LED driver are presented.

A Flow Analysis of a Refrigeration Warehouse where an Unusual Death of an Operator Occurred by Deficiency of Oxygen

  • Park, Chan-Seong;Moon, Jung-Eun;Kim, Yoon-Ho;Kim, Jin-Pyo
    • International Journal of Safety
    • /
    • 제5권2호
    • /
    • pp.29-33
    • /
    • 2006
  • A numerical flow analysis of the case of a refrigeration warehouse where an unusual death of an operator occurred by deficiency of oxygen is performed by using STAR-CD program of the computational fluid dynamics (CFD) code. The refrigeration room of the warehouse for storing the fruits maintains an atmosphere of 95% nitrogen and 5% oxygen by volume. When the operator was found dead in the refrigeration room, the room was in normal operating conditions except for the fact that the auxiliary door had been left open. For the flow analysis, unsteady 3-dimensional natural convection with mass transfer is considered. The flow analysis result is compared with the oxygen concentration level measured against time during on-site investigation. The change in oxygen concentration level in the warehouse due to the opening of the auxiliary door is found to be negligible.

가변 사판식 압축기의 탑 클리어런스 측정 방법 및 신뢰성 확보에 관한 연구 (Study on the Measuring Method and Reliability of Top Clearance of Variable Swashplate Type Compressor)

  • 김영신;나승규
    • 설비공학논문집
    • /
    • 제28권3호
    • /
    • pp.89-94
    • /
    • 2016
  • In this experimental study, the effects of top clearance on the performance of automotive a/c compressor were studied. Top clearance measuring device was also developed to ensure the reliability using vacuum conditions to secure constant control of top clearance without external environmental influence. Our results revealed that the improvements in compressor performance according to different top clearance values using the same compressor and same operator were about 4.12% at 800 rpm and about 7.8% at 2,000 rpm in 0.243~0.252 mm of top clearance compared to 0.431~0.456 mm of top clearance. To confirm the consistency in measuring top clearance affecting compressor performance, the top clearance measuring device was developed in this study using a vacuum pump. After performing reliable tests repeatedly, the distribution of measuring values under this device was within 0.99~1.83%, indicating that the constant test data in compressor performance was not affected by any other external environment.

Prediction of total sediment load: A case study of Wadi Arbaat in eastern Sudan

  • Aldrees, Ali;Bakheit, Abubakr Taha;Assilzadeh, Hamid
    • Smart Structures and Systems
    • /
    • 제26권6호
    • /
    • pp.781-796
    • /
    • 2020
  • Prediction of total sediment load is essential in an extensive range of problems such as the design of the dead volume of dams, design of stable channels, sediment transport in the rivers, calculation of bridge piers degradation, prediction of sand and gravel mining effects on river-bed equilibrium, determination of the environmental impacts and dredging necessities. This paper is aimed to investigate and predict the total sediment load of the Wadi Arbaat in Eastern Sudan. The study was estimated the sediment load by separate total sediment load into bedload and Suspended Load (SL), independently. Although the sediment records are not sufficient to construct the discharge-sediment yield relationship and Sediment Rating Curve (SRC), the total sediment loads were predicted based on the discharge and Suspended Sediment Concentration (SSC). The turbidity data NTU in water quality has been used for prediction of the SSC in the estimation of suspended Sediment Yield (SY) transport of Wadi Arbaat. The sediment curves can be used for the estimation of the suspended SYs from the watershed area. The amount of information available for Khor Arbaat case study on sediment is poor data. However, the total sediment load is essential for the optimal control of the sediment transport on Khor Arbaat sediment and the protection of the dams on the upper gate area. The results show that the proposed model is found to be considered adequate to predict the total sediment load.